Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹14.8 L
EMD Value
₹29,602
Closing Date
26 Nov 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Constr of appurtenants works allied works at Fatehpora Phase 1st Baramulla B.W.O SITC of Internal Electrification, with protective and Controlling devices, main control panel, cabling, wiring with fire extinguishers, earthing, lighting fixtur
2025_PWDJK_295074_1
NIT No.190/2025-26 Dt/13/11/2025
Open Tender
Electrical Works
Percentage
Fathepora Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹29,602
26 Nov 2025
13 Nov 2025
27 Nov 2025
13 Nov 2025
26 Nov 2025
13 Nov 2025
Wiring for Light point/Exhaust fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits.The job including cost of Circuit Wire (6/8 points per circuit) in 2.5 sq.mm (with 1x2.5 sq.mm) for earth Multi strand Copper wire from Switch board to D.B complete (Havells/Polycab/Anchor / eq. make to be approved by EIC),including cost of Conduits with other accessories like bends,Deep Junction Boxes,Surface Junctions etc to be laid in wall/ceiling(Slab) complete, with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front,Modular blanking plate where required & suitable GI box etc ISO/IEC Certified Havells/ Legrand/ Panasonic/ Anchor Rooma Plus/ Schneider/ABB/ eq. Make & shall be approved before execution of work.
Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits (Havells/Polycab/Anchor / eq. make to be approved by EIC) including cost of Conduits with other accessories like bends,Fan Junction Boxes to be laid in ceiling etc complete with 01 No. of 6 Amp Modular Switch,Two Module Stepped Type Electronic Fan Regulator, Modular Plate,Cover in front and suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/ Schneider/ ABB/ eq. Make & shall be approved before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/Finolex / eq. make to be approved by EIC) including cost of Conduits with other accessories like bends,etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering, with 01 No. of 16Amp,Modular switch, Modular 01 No. of 3-PIN 16Amp Socket, Modular plate, cover in front,Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/ Legrand/ Panasonic/ Anchor Rooma Plus/ Schneider/ ABB/eq. Make & shall be approved before execution of work.
Wiring for 6Amp Plug (Computer) with (P+N+E) 3 x 2.5 sq.mm FRLS PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab /Anchor/Finolex / eq. make to be approved by EIC),including cost of Conduits other accessories like bends etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering,with 02 No. of 6 Amp Modular Switch, 02 No.of Modular 6 Amp.of 5-PIN Socket,Modular Plate,Cover, Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider /ABB/eq. Make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor/Finolex / eq. make to be approved by EIC) including cost of Conduits with other accessories like bends etc complete to be laid in wall/ceiling(Slab) & shall be approved before execution of work.
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter Sub main From Main Panel to Distribution Boards.
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) forInverter Circuits.
Supply/Fixing/Testing and Commissioning of SP 6Amp to 32Amp Rating ,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load in existing MCB . DB Complete with connections.(Havells/L&T/Siemens/Legrand/ABB /Schneider / eq. make to be approved by EIC)
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (Havells/L&T/Siemens/Legrand/ABB/Schneider / eq. make to be approved by EIC)
Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (Havells/L&T/Siemens/Legrand/ABB /Schneider / eq. make to be approved by EIC)
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
Supply/Installation/Testing and Commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/LUKER USA /Anchor / eq. make to be approved by EIC.(3-Star)
Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Polycab/LUKER USA/Anchor / eq. make to be approved by EIC.(3-Star)
Supply/Installation/Testing and Commissioning of 10 Watt. LED Mirror Light fitting with Aluminium Body of Philips/Havells/Bajaj/Ledvance / eq. make to be approved by EIC including making of necessary connections Ceiling Rose,Silken wire also with round plates Etc complete.
Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
Supply/Laying/Connecting and Commissioning of 70 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/RR / eq. make to be approved by EIC with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories forProtection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench.
Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make.
Providing & Fixing of IK08 IP-66 protected high power 50 Watt LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. ( Phillips/Wipro/Havells/Jaquar/ eq. make to be approved by EIC)
Supply/Installation/Testing/Commissioning of NXG 1150/12V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing(with 2-Year Warranty), 01 No. of 200Ah,12V Tubular battery (with 05 Years Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Havells/Luminious/EXIDE/AMRON / eq. make to be approved by EIC
Supply/Installation/Testing & Commissioning of 20 KVA Single -Phase SERVO control VOLTAGE Stabilizer of Approved brand COPPER wound of Alba/AE/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications : Input voltage 90-260 volts(P-N) & output voltage 220 volts ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Control and Spike Protection complete job & having protection of 63Amp DP from output side Complete job.The Job Includes Supply, Installation, Testing & Commissioning of 63 AMP Single Phase change over switch as bypassing Switch of Havells/L&T/ABB/Siemens / eq. make to be approved by EIC ISI marked , incl making of necessary connections.
Supply/Laying/Testing/Commissioning of UTP4 pair CAT-6 LAN cable including the cost of PVC Conduit as required.
Supply & Installation of IP-20 & IK-08, UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, Vertical Mounting Rail 1.6 MM with 'U'Marking, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware, 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge For additional technical parameters of products/ work, refer Annexure "A" attached with this BSRof D-Link or Equivalent Make Including Supply of power extension cord etc:- 6 U Rack with Width 600 mm & Depth 400 mm + 100 mm
Supply/Installation/Testing/Commissioning of 32 Inches 4K LED Display Monitor as per the Specifications attached LG/SONY/Samsung / eq. make to be approved by EIC.
Supply/Laying/Testing/Commissioning of 2x1.5 sq mm PVC insulted multi strand copper wire of FRL make including the cost of PVC Conduit as required.
Supply/Installation/Testing/Commissioning of 08 Channel Network Video Recorder (NVR) as per the Specifications Enclosed with a Hard Disk Memory of 8 TB Capacity with HDMI cable patch cards.SONY/HONEYWELL/BOSCH/PELCO / eq. make to be approved by EIC.
Supply/Installation/Testing/Commissioning of Bullet Camera IP CCTV Monitoring, Recording & Streaming System per the Following Specifications:- Minimum 4-5 mega pixel progressive scan HD CMOS Lens :- 3-6 mm or Better , DC‐Iris/Auto Iris Field of view:-100˚to 45˚ (horizontal) 72-34 ° (vertical) Day/night operation:-The camera should provide day/night functionality automatically switches to night mode in low‐light scenes Wide dynamic range:- True WDR 100dB or equivalent or better Minimum illumination /light sensitivity Honey Well/BOSCH/PELCO / eq. make to be approved by EIC.
Supply/Fixing of water Dispenser with refrigerator Hot and Cold Taps of capacity 10 litres Acrylonitrile Butadiene styrene (ABS) of Blue/Voltas/Honeywell / eq. make to be approved by EIC and shall be approved bbefore supplying ( 3star)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
BOQ_954826.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .