Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹28.2 L+₹3.4 L (13.7%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹28.8 L+₹4.0 L (16.3%)Rejected-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹30.3 L+₹5.6 L (22.5%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹32.7 L+₹7.9 L (32.1%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
13 Jul 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_452374_1
GE MAINT EZHIMALA 8386
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
3 Aug 2021
17 Jun 2021
15 Jul 2021
17 Jun 2021
13 Jul 2021
1 Jul 2021
18 Jun 2021 - 25 Jun 2021
Amount
M&L for taking down the unserviceable LT UG cable of size upto 300 sqmm 3.5 core/04 core including removing electrical connection and keeping side serviceable cable including removing cable protection cover etc complete all as specified and directed by Engineer-in-Charge.
M&L for relaying of existing useable cable retrieved from item No. 01 above in the existing trench complete all as specfied and directed by Engineer-in-Charge. Note for Item No. 1 & 2 :- Necessary earth work shall be paid under relavant items under below.
M&L for excavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge. Note:- The excavation has to be done manually only.
M&L for returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed by Engineer-in-Charge.
Supply and spreading river sand or riddled earth for cushioning of the UG cable in trenches complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC unreinforced cable cover of size 250 mm x 150mmx40mm, class LV type I flat for cable protection complete all as specified and directed by Engineer-in-Charge.
Relaying of PCC unreinforced LT cable cover of size 250 mmx150mmx40mm obtained from item no 1 complete all as specified and directed by Engr in charge.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT 1100 volt grade with aluminium conductors of size 150 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per item no. 9 above but size of 120 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 95 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 70 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 50 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 35 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 25 sqmm 3.5 core complete all as specified and directed.
All as per item no. 9 above but size of 16 sqmm 4.0 core complete all as specified and directed.
All as per item no. 9 above but size of 10 sqmm 4.0 core complete all as specified and directed.
Supply and fix in replacement of cable route indicator for marking of UG cable cable of any size with cast iron round plate not less than 100 mm dia suitably fitted on iron and embedded with PCC block of size 30 cm x 30 cm x 45 cm complete all as specified and as directed.
M&L for bus bar chamber outdoor type of size 60cmx 60cmx45cm, made out of 3mm thick MS sheet with 630 Amp rated copper busbar with necessary insulators mounted on 25x25x 6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed.
M&L for bus bar chamber outdoor type of size 45cmx45cmx30cm , made out of 3mm thick MS sheet with 400 Amp rated copper busbar with necessary insulators mounted on 25x25x6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed.
M&L for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 Mtr and depth 0.7 Mtr all as directed and making good the road/hard using premix bituminous as required at site to match with the existing surface complete all as specified and as directed. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete all as specified and directed.
All as per item no. 22 above but size of 80 mm nominal dia complete all as specified and as directed.
M&L for jointing LT straight through joint kit 1100 volt , size 25-50 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge.
M&L for jointing LT straight through joint kit 1100 volt , size 70-120 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge.
M&L for jointing LT straight through joint kit 1100 volt ,size 150-185 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge.
M&L for jointing LT straight through joint kit 1100 volt , size 240-300 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, 'C' curve complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCB 32 Amp TPN 240/415 Volts, 'C' curve complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 125-160 Amp 25 KA / 415 volt rating four pole fixed thermal rating and adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 200-250 Amp 25 KA / 415 volt rating four pole fixed thermal rating cand adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 320-400 Amp 36 KA / 415 volt rating four pole fixed thermal rating and adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB upto 100 Amp 16/18 KA / 415 volt rating TP fixed thermal rating and adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 125-160 Amp 25 KA / 415 volt rating TP fixed thermal ratingand adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MCCB 200-250 Amp 25 KA / 415 volt rating TP fixed thermal rating and adjustable over load setting type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of ACB 4 Pole, 415 V, with thermal magnetic release (Manual Fixed type) of capacity 800 Amps as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of existing ACB 4 Pole, 415 V, with thermal magnetic release (Manual Fixed type) of capacity 630-1200Amps as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of change over switch disconnector 250Amps, four pole, 415Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of change over switch disconnector 400Amps, four pole, 415Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of change over switch disconnector 250Amps, four pole, 415Volts within sheet steel enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of change over switch disconnector 400Amps, four pole, 415Volts within sheet steel enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of sheet steel enclosure outdoor type for fixing suitable MCCB up to 400Amps complete all as specified and directed by Engineer-in-Charge.
Material and labour for welding and fabrication works of out/indoor panel board of any size as per site requirement complete all as specified by Engr in charge.
Material and labour for greasing in hinges, cleaning and removing grass not exc 1 mtr around of out/indoor panel of any size as site requirement complete all as specified by Engr in charge.
Supply and fix in replacement of hinges, sliding door bolt of outdoor/indoor panel of any size as site requirement complete all as specified by Engr in charge.
M&L for cleaning, scrapping out the faded/rusted old paint from the LT panel using wire brush, emery paper, and prepare the surface for painting, applying one coat of aluminium paint over the surfaces including bolts and nuts etc complete all as specified and directed by Engr in Charge.
Repair/Replacement, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type out door LT panel with canopy, fabricated with 3.15mm thick CRCA sheet steel with necessary angle iron frame work 50x50x5mm, weather proof vermin proof and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply system complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling, cable alley suitable for termination of cable including supply and fixing of following switchgear and accessories in the panel complete as required conforming to relevant IS specification. The panel should be CPRI approved and having IP 65 protection including necessary PCC foundation 1:4:8 type D2 coping with PCC 1:3:6 type C1 for mounting and panel should be powder coated painting with synthetic enamel paint all as specified and directed. (i) Aluminium bus bar suitable for 1000 Amps TPN mounted on suitable SMC based insulators. (ii) MCCB 4 pole 630Amps, 50KA - 01 No ( incoming) fixed thermal magnetic release and adjustable over load setting. (iii) MCCB 4 pole 400Amps, 36KA - 02 No ( outgoing) fixed thermal magnetic release and adjustable over load setting. (iv) MCCB 4 pole 250Amps, 25KA - 02 No ( outgoing) fixed thermal magnetic release and adjustable over load setting. (v) Multi Function Meter(VAF) - 01 No (vi) Phase indicating lamp with suitable MCB alongwith control wiring - 1 Set NOTE:- Panel layout shall be approved by the Engineer-in-Charge before commencement of fabrication.
ANAND REFRIGERATION
OM Enterprises
Sreekrupa Enterprises
KDR CONSTRUCTION
AR Traders
devan enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .