| Sl No | Description | Qty | Unit | LOKNATH ENGINEERING L1 | BISWAJIT PAUL L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of 5 TR(Min) capacity concealed type Split Air Conditioner of rated Cooling capacity of 90000 BUT/hr. With. Twin rotary compressor, 2 Nos. IDU of rated power supply-230V-1 ph-50Hz., 1 No. ODU of rated power supply-400V-3ph-50Hz. Air flow/per IDU:-1000CFM with R410A ( Make – HITACHI/Mitsubishi/ogeneral ) | 4 | Nos | 2,12,000 ₹8,48,000 Lowest | 2,30,000 ₹9,20,000 |
| 2.00 | SITC of 2 TR Split type AC machine with R410A/R32 and 3star rating (ISEER 2018) complete with installation kit, indoor base, plug top, input power cable and outer wall base for installation of ODU as per direction of EIC. Make- OGeneral/Mitsubishi Electric | 1 | No | 62,000 ₹62,000 Lowest | 70,000 ₹70,000 |
| 3.00 | Thorough purging of Refrigeration Unit by Nitrogen gas pressure for removal of moisture, slag & dust for proper cooling performance including supply of N2 gas. | 4 | Nos | 1,000 ₹4,000 Lowest | 3,000 ₹12,000 |
| 4.00 | Supply and fitting of 5/8” and 3/8” Copper pipe line including insulation pipe and cable 4 core 2.5 Sq.mm for concelaed split AC machines incl Supply & fitting of insulated Wrapping tape twice to avoid pricking of crow & rat. | 40 | Mtr | 1,900 ₹76,000 | 800 ₹32,000 Lowest |
| 5.00 | Supply and fitting of 5/8” and 1/4” Copper pipe line including insulation pipe and cable 3core 2.5 Sq.mm for concelaed split AC machines incl Supply & fitting of insulated Wrapping tape twice to avoid pricking of crow & rat. | 4 | Mtr | 1,000 ₹4,000 | 300 ₹1,200 Lowest |
| 6.00 | SITC of concealed split AC incl. ,fabrication & fixing of 2 nos M.S. Angle/M.S.U. Channel of size(75mm x75mm x6mm) for placing the outdoor unit of HAT & Concealed type Air Conditioning Machines incl. drilling 05 nos holes in each angle including cutting holes into the wall & grouting the (1:1 1/2 :3) etc. for Air Conditioning Units.Supplying,fabrication & fixing 4 Nos. M.S. u-channel of 6mm thick of size(75mm x 40mm x40mm)& ISA 50 x50x6 mm for making Base frame table type for installation of incl. drilling 2 nos. holes in each channel. ( For Out Door Unit) & 2 Nos IDU fixing by the rod & necy angle bullet | 4 | Nos | 5,500 ₹22,000 | 2,000 ₹8,000 Lowest |
| 7.00 | Supply & filling of Compressor mounting rubber to resist shock of the compressor during running ( 3 Nos. = 1 Set) | 4 | Sets | 200 ₹800 Lowest | 1,000 ₹4,000 |
| 8.00 | SITC of Discrite Powder Coaed Al. Grill without VCD (Make:Primier/AFl/Air Primier) | 0.6 | Sq.Mtr | 4,000 ₹2,400 | 2,000 ₹1,200 Lowest |
| 9.00 | Fabrication, supply, installation, testing & commissioning of ducting collar following gauge connecting the air flow from IDU to drop ceiling grill by G.I. Sheet (20 SQG) | 6 | Nos | 1,500 ₹9,000 | 300 ₹1,800 Lowest |
| 10.00 | Supply & errection of aluminium composite panels ( ACP ) interior grade of thickness 3.00 mm comprising of protective flim, polyester coating. Finnaly service as per manufacture specification finished with aluminium screw and silicon sealent complete in all respect incluiding all cuuting charges etc as per direction of EIC . The colour is off white colour ACP Combination as per direction of EIC. ( Make - Aludecor / Pratap or as per direction of EIC ) | 20 | Sq.Mtr | 1,000 ₹20,000 Lowest | 1,500 ₹30,000 |
Tender Value
Refer Docs
EMD Value
₹22,015
Closing Date
29 May 2026, 1:00 pmClosed
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Electrical Works at Proposed blood composition seperation unit at the existing Peadiatric Ward Adjacent to the existing blood centre at Ranaghat SDH Nadia--SITC of AC Machine
2026_WBPWD_5014051_1
WBPWD/EE/NED/NIQ/e-T/63/ (3rd Call)26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
35 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
6 documents required · 6 mandatory
₹22,015
7 Oct 2026
14 May 2026
1 Jun 2026
14 May 2026
29 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of 5 TR(Min) capacity concealed type Split Air Conditioner of rated Cooling capacity of 90000 BUT/hr. With. Twin rotary compressor, 2 Nos. IDU of rated power supply-230V-1 ph-50Hz., 1 No. ODU of rated power supply-400V-3ph-50Hz. Air flow/per IDU:-1000CFM with R410A ( Make – HITACHI/Mitsubishi/ogeneral ) | 4 | Nos | - | - |
| 2 | SITC of 2 TR Split type AC machine with R410A/R32 and 3star rating (ISEER 2018) complete with installation kit, indoor base, plug top, input power cable and outer wall base for installation of ODU as per direction of EIC. Make- OGeneral/Mitsubishi Electric | 1 | No | - | - |
| 3 | Thorough purging of Refrigeration Unit by Nitrogen gas pressure for removal of moisture, slag & dust for proper cooling performance including supply of N2 gas. | 4 | Nos | - | - |
| 4 | Supply and fitting of 5/8” and 3/8” Copper pipe line including insulation pipe and cable 4 core 2.5 Sq.mm for concelaed split AC machines incl Supply & fitting of insulated Wrapping tape twice to avoid pricking of crow & rat. | 40 | Mtr | - | - |
| 5 | Supply and fitting of 5/8” and 1/4” Copper pipe line including insulation pipe and cable 3core 2.5 Sq.mm for concelaed split AC machines incl Supply & fitting of insulated Wrapping tape twice to avoid pricking of crow & rat. | 4 | Mtr | - | - |
| 6 | SITC of concealed split AC incl. ,fabrication & fixing of 2 nos M.S. Angle/M.S.U. Channel of size(75mm x75mm x6mm) for placing the outdoor unit of HAT & Concealed type Air Conditioning Machines incl. drilling 05 nos holes in each angle including cutting holes into the wall & grouting the (1:1 1/2 :3) etc. for Air Conditioning Units.Supplying,fabrication & fixing 4 Nos. M.S. u-channel of 6mm thick of size(75mm x 40mm x40mm)& ISA 50 x50x6 mm for making Base frame table type for installation of incl. drilling 2 nos. holes in each channel. ( For Out Door Unit) & 2 Nos IDU fixing by the rod & necy angle bullet | 4 | Nos | - | - |
| 7 | Supply & filling of Compressor mounting rubber to resist shock of the compressor during running ( 3 Nos. = 1 Set) | 4 | Sets | - | - |
| 8 | SITC of Discrite Powder Coaed Al. Grill without VCD (Make:Primier/AFl/Air Primier) | 0.6 | Sq.Mtr | - | - |
| 9 | Fabrication, supply, installation, testing & commissioning of ducting collar following gauge connecting the air flow from IDU to drop ceiling grill by G.I. Sheet (20 SQG) | 6 | Nos | - | - |
| 10 | Supply & errection of aluminium composite panels ( ACP ) interior grade of thickness 3.00 mm comprising of protective flim, polyester coating. Finnaly service as per manufacture specification finished with aluminium screw and silicon sealent complete in all respect incluiding all cuuting charges etc as per direction of EIC . The colour is off white colour ACP Combination as per direction of EIC. ( Make - Aludecor / Pratap or as per direction of EIC ) | 20 | Sq.Mtr | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
BOQ_5081978.xls
BOQ • 0.28 MB
form2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .