Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹10.6 L
EMD Value
₹21,200
Closing Date
30 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RnB Div Sgr Core
Office of the Executive Engineer RnB Div Sgr Core
Construction of ACR at Girls Middle School Zakura
2025_PWDJK_298954_1
57 of RNB//Sgr-Core/2025-26
Open Tender
Civil Works
Percentage
95 days
Srinagar
please refer tender docs
2 documents required · 2 mandatory
₹600
Executive Engineer RnB Div Sgr Core
₹21,200
23 Dec 2025
23 Dec 2025
31 Dec 2025
23 Dec 2025
30 Dec 2025
23 Dec 2025
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Supplying and laying of Nallah Dry Stone Soling hand packed tightly including rammming, watering and filling of interstices including all carriages complete.
Providing and laying in position cement concrete of specified grade including curing but exculding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement:4 coarse sand:8 graded stone Aggregrate 40mm nominal size.)
Providing and laying in position of cement concrete Of specifed grade including curing but excluding the cost of centering shuttering, all works up to plinth level with 1:1:5:3 including cost of carraige of material lead upto 12km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.All works upto plinth level in M-10 (1:3:6) grade, with 20mm nominal size of crushed stone aggregates, Including carraige of material involved lead upto 12 km
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°raft, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 graded crshd stne agg. 20mm nominal size all carriages of material lead upto 12km involved & head load.
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc.
Centering and shuttering including strutting, propping etc. and removal of form for Lintel,beams,plinth beams girders,bressumers and cantilevers
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1Thermo-Mechanically Treated bars of grade Fe-415 or Fe-500D or more as per requirement of structural Design Including carraige of material involved
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) Second class kail wood
Providing fixing 25 mm PVC Conduits I/c junction boxes fan boxes etc focomplete as desire at site of work.
Cement plaster in 1:6 (1 cement:6 fine sand ),12 mm thick.
Providing and laying of 2mm wall putty of approved brand and manfacture of two or more coats including cost of scaffolding & material for complete job
Providing and fixing glazed shutters for Dors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class Kail wood
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge 35mm thick Second class Kail wood
Providing & fixing Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters (Area of opening for glass panes excluding portion inside rebate shall be measured)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/liter
Finishing walls with exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats)
Painting with Ready mixed synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work
Cement concrete flooring 1:2:4 (1Cement:2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the east of nosing of steps etc complete 50mm thick with 20mm nominal size stone aggregate crushed
Providing and fixing of the following hardware fittings.Tower Bolts 100mm
Tower Bolts 150 mm for door
Handle 125 mm
Aldrop 250 MM
Structural Steel work welded in built up sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete. welded.Including carraige of material involved
Providing and fixing precoated (HI-RIB) galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts, leads and carriages including ridges, hips and valley etc
Providing and fixing 12 mm thick Brown or pre-laminated wood base particle board or graded particle board , in ceiling with necessary nails etc. complete as directed by EIC (frame work to be paid separately):
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo Wood /Firewood
Providing and fixing of 50 mm thick wooden cornice of budloo wood make including cost of nails scaffolding
Lighting point (one lighting pointincludes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement. One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work
Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire, 16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work.
Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi-strant copper wire 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
BOQ_969584.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .