Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.3 L+₹62,941 (1.35%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹47.9 L+₹1.2 L (2.57%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹51.0 L+₹4.3 L (9.27%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹49.5 L
EMD Value
₹98,980
Closing Date
10 Nov 2023, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINTENANCE OF EXTERNAL FIRE FIGHTING PIPE LINE, SWT PIPE LINE AND CONNECTED ITEMS IN AA BANAR
2023_MES_623053_1
8823/61/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Banar
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Garrison Engineer, Banar
₹98,980
Yes
16 Dec 2023
13 Oct 2023
13 Nov 2023
13 Oct 2023
10 Nov 2023
27 Oct 2023
Amount
Supplying, laying, jointing, testing and commmisioning of DI Pipe of size 100 mm bore as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket end with fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps, tyton joint and plugs laid in trenches including taking down old unsv CI/DI pipe complete all as specified. Note : - (i) The charges for tyton joint is deemed to be included in above quoted rates. (ii) All fitting/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and excavation, earth work shall be measured and paid separately under respective items of schedule.
All as per Item Ser No 1.00 above but of size 150 mm bore
Material and labour for GI tubing 'medium grade' of size 20 mm bore with all fittings such as sockets, bends, unions, tee, short pieces, flange and nipples, (specials) complete all as per IS 1239 (part-I) laid in trenches/floors/fixed to walls and ceilings including taking down old unsv GI pipe complete all as specified. Note : - (i) The charges for all fitting, joint, flange hook/clamp and welding work is deemed to be included in above quoted rates. (ii) Excavation, earth work shall be measured and paid separately under respective items of schedule.
All as per Item Ser No 3.00 above but of size 25 mm bore
All as per Item Ser No 3.00 above but of size 50 mm bore
All as per Item Ser No 3.00 above but of size 80 mm bore
All as per Item Ser No 3.00 above but of size 100 mm bore
All as per Item Ser No 3.00 above but of size 150 mm bore
Material and Labour for GI tubing Heavy grade 25 mm bore flanged type for submersible pump/monoblock pump/centrifugal pump set suction/delievery including required rubber gaskets, nuts, bolts and connection items complete all as per IS 1239 (part-I) laid in trenches/floors/fixed to walls and ceilings including taking down old unsv GI pipe complete all as specified.
All as per Item Ser No 9.00 above but of size 50 mm bore
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') size of 80 mm bore with flange end laid in trenches with wrapping the anticorrosive material with 4 mm thick polymer corrosion resistant tape as per IS with 15 mm over lap and on ground/ vertically for connections to fire hydrants with welded joints/Flange joint including removing the rusted, broken old MS pipe in trenches all directed at site Note:- (i) The charges for all fitting, joint, flange hook/clamp, welding work and polymer corrosion resistant tape is deemed to be included in above quoted rates
All as per Item Ser No 11.00 above but of size 100 mm bore
All as per Item Ser No 11.00 above but of size 150 mm bore
All as per Item Ser No 11.00 above but of size 200 mm bore
Supply, fixing, jointing & testing Cast Iron Sluice Valve size of 80 mm bore ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body, confirming to IS 14846 -2000, having gun metal (brass) spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
All as per Item Ser No 15.00 above but of size 100 mm bore
All as per Item Ser No 15.00 above but of size 150 mm bore
Supply, fixing, jointing & testing butterfly valve (wafer type) of size 50 mm bore, ISI Marked, gun metal (brass) rust and corrosion free,flanged ends drilled pressure rating PN-1.0, including taking out unsv butterfly valve complete all as specified.
All as per Item Ser No 18.00 above but of size 80 mm bore
All as per Item Ser No 18.00 above but of size 100 mm bore
All as per Item Ser No 18.00 above but of size 150 mm bore
Supply & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 of size 25 mm bore including taking out unsv gate valves complete all as specified.
All as per Item Ser No 22.00 above but of size 50 mm bore
Supplying & fixing PTMT float valves high pressure with polythene float and fly nut, screwed for iron pipe, GI pipe tank connection fitting complete,of size 25 mm including taking out unsv float valve complete all as specified. Note: GI pipe tank connection fitting is deemed to be included in above quoted rates
Supply and fix in replacement of long collar Dett Joint suitable for 80 mm bore CI/DI pipe incl rubber rings and nut bolts and washers all as directed at site.
All as per Item Ser No 25.00 above but suitable for 100 mm bore
All as per Item Ser No 25.00 above but suitable for 150 mm bore
M&L for run lead joint suitable for CI pipe 80 mm dia complete all as specified.
All as per Item Ser No 28.00 above but suitable for CI pipe 100 mm dia.
All as per Item Ser No 28.00 above but suitable for CI pipe150 mm dia.
M&L DI fitting any type like bend, tapper, tail piece, collars and reducers etc up to 150 mm bore for spigot socket pipesall complete all as directed at site.
M&L for cutting and screwing existing GI tubing for addition / alteration (Each cut measured) of size 25 mm bore in existing position without taking up or down complete all as directed at site.
M&L for cutting and screwing existing GI tubing for addition / alteration (Each cut measured) of size 40/50 mm bore in existing position without taking up or down complete all as directed at site.
Supply & fixing in replacement of Clamp connector of size 150mm dia / 50 mm dia, made out of MS sheet, duly welded with suitable size socket and accessories including two coat of synthetic enamel painting, gasket, nuts, bolts, washers complete all as directed.
All as per Item Ser No 34.00 above but of size 100mm/ 25mm
All as per Item Ser No 34.00 above but of size 80mm/ 25mm
Supply and fixing in replacement of Air release valve,20 mm size complete all as directed
Supply and fixing in replacement of Air release valve,80 mm size complete all as directed
Supplying & fixing heavy duty foot valve S shaped consisting of synthetic rubber coated reinforced ball type CI body flanged and drilled of size 50 mm bore with nuts, bolts including taking out unsv foot valves complete all as specified.
All as per Item Ser No 39.00 above but of size 80 mm bore
All as per Item Ser No 39.00 above but of size 150 mm bore
Supplying & fixing heavy duty NRV consisting of synthetic rubber coated reinforced ball type CI body flanged and drilled of size 50 mm bore with nuts, bolts including taking out unsv NRV complete all as specified.
All as per Item Ser No 42.00 above but of size 80 mm bore
All as per Item Ser No 42.00 above but of size 100 mm bore
M&L for preparation of old painted steel surfaces of any descreption/size and applying two coats of synthetic enamel paint grey/sky blue/existing colour over a coat of red oxide primer on GI/MS/DI pipe complete all as directed.
M&L for attending to break down of fire fighting pipe line size of up to 150 mm CI/DI/MS bursting/cracks including removal of broken pipe pieces of various lengths through gas cutting/manual cutting as per site requirement including burning the defective lead joints and removing out the damaged CI/DI/MS/GI pipe and inserting necessary specials such as CI collar etc. as required at site and providing of new lead joints as required at site, including testing for the leakages of lead joints complete all as specified. NOTE: (i) The earth work involved for excavation, returning filling & removal of soil is deemed to be included inquoted rates. (ii) Welding / plumbing works involved for repairing of pipe lines and necessary T&P like welding machine, threeding dise etc including man power is deemed to be included in quoted rates. (iii) Transportation charges for shifting of T&P etc is deemed to be included in above quoted rates.
M & L for servicing of Sluice valve of 80/100/150 mm by removing gland and packing, valve set cover, metal filling and grinding valve set, inspecting, oiling, greasing spindle, check nut assembly, removing gate from valve seat and applying grease on the seat, reassembling the valve, appling grease on spindle trust plate easy operation and fixing new gland packing and applying one coat of black colour paint over one coat of primer complete all as directed
Dismantling the existing broken valve pit cover and re-construct of brick masonry wall pit size 105cm x 105cm x 105cm internal dimension suitable for 80/100/150 mm dia pipe including excavation and earth work and disposal of soil, plastering internally and flush pointing to brick surface externally as the work proceeds complete with 3.15mm thick MS sheet cover angle iron frame 40x40x6mm and locking arrangement and painting with two coats of black bitumenous paint over a coat of red oxide primer all as specified.
Supply & fixing Nuts ,Bolts and washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified.
Disconnecting of electrical connection from panel board and taking out electic motor capacity 15-25 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalling after repair and testing complete all as specified.
All as per Item Ser No 50.00 above but of motor capacity 40-60 HP
All as per Item Ser No 50.00 above but of motor capacity 75-100 HP
Opening the electric induction motor of cap 15-25 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge including all other insulating material complete all as specified. Note : "Copper winding wire of appropriate gauge will be measured under item No. 65 as supply only"
All as per Item Ser No 53.00 above but of motor capacity 40-60 HP
All as per Item Ser No 53.00 above but of motor capacity 75-100 HP
Supply and fixing in replacement of terminal box and terminal connection plate for 15-25 HP Motor. incl copper terminals nuts, washers, cable copper lugs and screws all as directed. terminal box for 15-25 HP Motor.
All as per Item Ser No 56.00 above but of motor capacity 40-60 HP
All as per Item Ser No 56.00 above but of motor capacity 70-100 HP
supply and Fixing in replacement of ball bearing for electric motor 15-25 HP complete all as specified.
Supply and Fixing in replacement of ball bearing for electric motor 40-60 HP complete all as specified.
Supply and Fixing in replacement of ball bearing for electric motor 75-100 HP complete all as specified.
Supply and Fixing in replacement of fan blade with casing for electric motor 15-25 HP complete all as specified.
Supply and Fixing in replacement of fan blade with casing for electric motor 40-60 HP complete all as specified.
Supply and Fixing in replacement of fan blade with casing for electric motor 75-100 HP complete all as specified.
Supply only super enamelled copper winding wire of existing gauge suitable for electric motors as mentioned in item No. 53.00, 54.00, 55.00 & 80.00
Disconnecting and De-coupling the centrifugal pump of cap 15-25 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as directed.
All as per Item Ser No 66.00 above but of Pump capacity 40-60 HP
All as per Item Ser No 66.00 above but of Pump capacity 75-100 HP
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts like CI Impeller, CI Casing wear ring DE/NDE, CI Gland plate, Key for impeller, Impeller nut, CI Stuffing box bush, Pump shaft SS (AISI-410), Gland packing champion, CI Bearing cartiage DE/NDE, CI star coupling, SS Eye bolt with nut, CI Shaft sleeve, Set Gasket packing,remetalling of pump shaft turning and balancing, including machining work and re-assembling the same in original position of 15 to 25 HP Note:- (i) The charges for spare part is deemed to be included in above quoted rates.
All as per Item Ser No 66.00 above but of Pump capacity 40-60 HP
All as per Item Ser No 66.00 above but of Pump capacity 75-100 HP
M&L for painting (two coat of synthetic Enamel paint) on centrifugal pump & motor and submersible pump set of any capacity rating 5-100 HP and suction/delivery pipe line including NRV and sluice valve, MS Base chanel including preparation of surfaces by scratching and removing the rust complete all as specified.
Supply and fixing in replacement of complete CI star coupling set for for electric motor 15-25 HP complete all as specified.
Supply and fixing in replacement of complete CI star coupling set for for electric motor 40 to 60 HP complete all as specified.
Supply and fixing in replacement of complete CI star coupling set for for electric motor 75-100 HP complete all as specified.
S & F in replacement of MS base channel of existing size including cutting welding making holes and painting (two coat of synthetic enamel paint over a coat of red oxide primer) complete all as specified
S & F in replacement of MS foundation bolts with nuts and washers size 20 mm dia and 450 mm long complete all as specified.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coppings, benching, kerbs, edges, foundation of pump sets of different sizes Complete all as specified. Note : Rates are deemed to include earth work for demolition of concrete and removal of bolts.
Disconneting of electrical connection from the panel board, and starter of submersible pumping set of any model / make size 5 HP to 15 HP capacity and removing the pipe line connection from discharge side and taking out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to Workshop and back after repair and lowering of same pumping bore well including replacement of rusted nuts bolts rubber gasket complete all as specified.
Opening the submersible pump set of capacity 5 HP to 15 HP including taking down/out the burnt winding wire cleaning the slots. rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts like bearing bush, rotar sleeve, water seal and cable seal, sand guard, Sealing ring, Flange upper/lower with stud and nut, Seal bush, Thrust plate, Stainless Steel coupling,remetling of rotar end turning and making key way, balancing of rotar, Rotar sleeve turning and grinding,T-Bolt with nut, LNK Bolt Stainless Steel, Submersible cable jointing, G.M Impeller, CI NRV Body, Impeller Key, Stainless Steel Pump shaft single stage, Remetling of G.M Impeller and turning including machine work and re assembling the pump set in original position with required insulating material to make it functional complete all as specified. Note :- (i) The charges for spare part is deemed to be included in above quoted rates. (ii) Copper winding wire of appropriate gauge will be measured under item No. 65 as supply only"
M&L for replacement of existing u/s coupling guard of Pump motor 15 to 100 HP made out of MS iron fabricating structure, nut, bolts, washers etc. complete all as directed at site.
Supply and fixing water proof submersible cable 25 Sqmm 3 core copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified. Note: (i) Necessary T&P for taking out submersible pump set from bore well will be provoded by conractor.
All as per Item Ser No 82.00 above but of size 16 Sqmm 3 core
Transportation of air compressor with tools and accessories at different location in Army area Banar for devlopment of borewell as specified and as directed by the Engr -in charge.
Devlopment of bore well, if any capacity size, not more tha 100 mtrs deep, at the prssure not less than 6 Kg/Sqcm by disel engine driven air compressor of capacity 450 cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well as specified and as directed
M & L for lowering up and down of submersible pumpset upto 15 HP capacity for a depth of 50 metre approx. including opening of coloumn pipes and replacement of old rubber gasket, nut bolts and refixing the same at same location Note :- GI tubing Heavy grade 50 mm bore flanged type will be measured and paid seperately under relevant item of schedule
Comprehensive maintenance of Diesel engine driven split case multistage pump set of 105/100/92/85 BHP for routine/preventive maintenance, checking up of Engine and pump for smooth functioning. The type of work/maintenance services to be carried out during comprehensive maintenance are as under:- (a) Cleaning of air filter (b) Checking and adjusting of valve tappet clearance. (c) Checking of Engine lubrication system, fuel system, air system, cooling system, mechanical adjustments/rectification and electrical system. (d) Changing of lube oil filter if necessary, (e) Changing/cleaning of fuel pre & fine filter. (f) Checking and tightening of bolts and nuts. (g) Checking of star CI coupling. (h) Checking of charging system of the battery. (i) Checking of ‘V’ belt and adjusting the tension. (j) Checking of exhaust turbo charger. (k) Checking of fuel injector. (l) Checking and cleaning of breather pipe. (m) Checking of siphon pipe including pressure guage (n) Checking of speed governors and engine shut down for proper functioning. (o) Checking of proper functioning of self starter and provision and battery charging. Note: (i) Carrying out preventive maintenance, checking as per manufacturer’s recommendations and to make proper functioning/serviceability of u/s RPM meter and hour meter and all engine parameters, gauges through out the CA period. (ii) spare parts will be measured and paid separartely under supply only items
Supply only in replacement of Oil filter element
Supply only in replacement of fuel filter element
Supply only in replacement of Air filter element
Supply only in replacement of V-belt as per sample
Supply only in replacement of rubber hose connectors of Turbo charger Line
Supply only in replacement of fuel/Oil pipe of existing pump
Supply only in replacement of Engine Oil (15W40)
Supply only in replacement of coolant
Supply only in replacement of siphon pipe including pressure guage
M&L for servicing of self starter assembly of Diesel engine driven 12/24 volts by dis connecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, penion of existing teeth, bendex bushes, Armature,solenoid Assy 12 volt contact plates, jumping levels etc and rewinding the u/s field coil etc and varnishing. complete all as specified.
Material and labour for replacement of lead acid maintenance free battery , 12 volt, 180 AH suitable for Diesel engine driven split case multistage pump set of 105/100/92/85 BHP complete all as specified.
Taking down carefully single fire hydrant gun metal 63 mm bore control valves and cap, cleaning, greasing, replacement of spindle,rubber valve gasket, gland packing ,grainding valve seating, essential nuts,bolts,washer,gaskets etc and re-fixing and testing on completion complete all as directed by Engineer - in -charge
All as per Item Ser No 99.00 above but double hydrant
All as per Item Ser No 99.00 above but four way hydrant
Supply and fixing in replacement of defective /unserviceable single hydrant valve of 63 mm dia, made out of gun metal As per IS:5290 Type-B complete all as specified and directed
All as per Item Ser No 102.00 above but of double hydrant
All as per Item Ser No 102.00 above but of 4 way hydrant
Material & labour in replacement of old unserviceable Single door hose box for keeping 01 Nos of CP hose pipe of length 30 M and dia 63 mm made up of 18 gauge MS sheet of suitable size with 3 mm thick glass and door frame made of 16 gauge MS sheet painted fire red with two coats of synthetic enamel paint over a coat of red oxide primer and brilliant white inside box mounted on angle iron stand fixed at 150 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, complete all as specified and directed at site.
All as per Item Ser No 105.00 above but double door hose box
Material & labour in replacement of old unserviceable CP hose cotton breaded of size 30 M long of dia 63 mm complete all as specified and directed at site.
Material & labour in replacement of old unserviceable Hose reel drum incl rubber hose 30m length and of size 20 mm complete all as specified and directed at site.
Material & labour in replacement of old unserviceable rubber hose 30m length and of size 20 mm complete all as specified.
Supply & fixing in replacement of damaged / defective / unserviceable male coupling with spring loaded NRV for four way fire brigade inlets, instantaneous type,SS coupling 63 mm dia complete all as specified.
Supply & fixing in replacement of single phase preventer 230 V,50 HZ of L&T make or equivlant, complete all as directed by the Engineer-in-Charge
supply and fixing in replacement of fully automatic star delta starter with sheet metal enclousure made out of 3.15 mm CRC sheet , panel mounting type with timer, relay and contactor incl push button 2 nos, volt meter and amp meter, MCB TPN-63 Amp-01 Nos suitable rating for use at 25 HP Pump set connecting, testing complete all as directed at site.
All as per Item Ser No 112.00 above but of suitable for 20 HP Pump Set
All as per Item Ser No 112.00 above but of suitable for 15 HP Pump Set
All as per Item Ser No 112.00 above but of suitable for 12.5 HP Pump Set
All as per Item Ser No 112.00 above but of suitable for 10 HP Pump Set
All as per Item Ser No 112.00 above but of suitable for 7.5 HP Pump Set
All as per Item Ser No 112.00 above but of suitable for 5 HP Pump Set
supply and fixing in replacement of burnt power contactor, 3/4 pole, 50 Hz suitable for the existing motor of cap 100 HP at site complete all as directed
All as per Item Ser No 119.00 above but of capacity 75 HP
All as per Item Ser No 119.00 above but of capacity 60 HP
All as per Item Ser No 119.00 above but of capacity 25 HP
All as per Item Ser No 119.00 above but of capacity 20 HP
All as per Item Ser No 119.00 above but of capacity 15 HP
All as per Item Ser No 119.00 above but of capacity 5 HP to 12.5 HP
supply and fixing in replacement of burnt bimetal over load relay for the 100 HP of motor (relay range 78-130 Amps) starters as existing at site complete all as directed
All as per Item Ser No 126.00 above but of suitable for 75 HP Motor (relay range 70-100 Amps)
All as per Item Ser No 126.00 above but of suitable for 60 HP Motor (relay range 59-85 Amps)
All as per Item Ser No 126.00 above but of suitable for 25 HP (relay range 22-32 Amps)
All as per Item Ser No 126.00 above but of suitable for 20 HP Motor (relay range 17-25 Amps)
All as per Item Ser No 126.00 above but of suitable for 15 HP Motor (relay range 15-22 Amps)
All as per Item Ser No 126.00 above but of suitable for 5 to 12.5 HP (relay range 12-18 Amps)
Supply and replace Electronic Timer, type ET-100 of L&T make, 50 HZ complete all as directed by the Engineer-in-Charge
Cleaning of RCC Semi under ground fire fighting Sump of capacity 100000 gallon by pumping out the accumulated water at the bottom using submersible pump,removing the complete slit by suction process using either suction pump or vacuum process, cleaning the walls, ceilling & floor using high pressure water jet with pressure up to 2300 PSI to dislodge all the mud,dirt,algea,fungus and layers of calcinations,vacuum cleaning to remove the dislodged waste using industrial vacuum cleaner, spraying anti- bacterial agent/ food contact sanitizers to walls,celling & floor of tank to make it sterile to take care of any futher suspend bacteria,viruses which might have remained in the tank complete with out disturbing the water supply to area applying one coat of white wash to entire tank as taking out after cleaning and deposting to a distance upto 50 Mtr from the starting point all as directed by the Engr-in-Charge including writing the date of cleaning of tank on external wall of semi under ground tank at appropriate location with 4 inch (100mm) sizes in capital letter by using synthetic enameled paint of white colour on black painted surface of suitable size all as directed by Engr in Charge
All as per Item Ser No 134.00 above but of capacity 50000 gallon
Supply and Fixing in replacement of Digital Volt Meter 0-500 Volt fitted on existing any type of LT Panel including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified and directed.
Supply and Fixing in replacement of Digital Amp Meter 0-400 Amp with CT of same rating fitted on existing any type of LT Panel including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified and directed.
M&L for servicing of motor pump set up to 60 HP after opening of non driving end motor fan cover, cleaning of outer body of motor/pump set, NDE fan and greasing of bearing at both side of motor & pump set incl spray painting (colour as per existing) of motor pumpset & foundation channel, gland packing of suitable size and tightening of foundation nut/bolt, power cable terminations complete all as specified. Note : - (i) The charge for grease and painting work is deemed to be included in above quoted rates. (ii) Gland packing and copper lugs shall be measured and paid separately under respective items of schedule.
M&L for Gland packing soft type with lead wool metallic lined superior quality as per sample of size 10/12mm Complete all as specified.
supply and fixing copper lugs suitable for copper cable size up to 25 sqmm
Excavation in trenches not exceding 1.5M vide and n. exe 1.5 M in depth for laying of pipes etc. and getting out in any type of soil complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type soil complete all as specified.
Removing excavated material n. exc 50M and deposting where directed at a level n. exc 1.5M above the starting point in any type of soil all as specified.
Cutting of bituminous road for laying of pipe line not exceeding 1.5 M depth/width including making to disturbed portion good as per existing complete all as specified.
M&L in replacement of PVC conduit 32 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified.
All as per Item Ser No 145.00 above but of Size 25 mm
M&L for in replacement of twisted Nylon Rope size of 8 mm suitable for hanging of submersible pump in shallow well complete all as specified and as directed.
Supply and Fixing in replacement of Ball bearing for 15 to 25 HP Motor complete all as specified.
Supply and Fixing in replacement of Ball bearing for 40 to 60 HP Motor complete all as specified.
Supply and fixing in replacement of Rubber coupling of size 016 suitable for non clog Pumpset of capacity 100 HP, including alignment of pump with motor complete all as specified
Supply and fixing in replacement of Rubber coupling of size 015 suitable for non clog Pumpset of capacity 60 HP, including alignment of pump with motor complete all as specified
Supply and fixing in replacement of Rubber coupling of size 013 suitable for non clog Pumpset of capacity 25 to 30 HP, including alignment of pump with motor complete all as specified
Supply and fixing in replacement of Rubber coupling of size 012 suitable for non clog Pumpset of capacity 15 HP, including alignment of pump with motor complete all as specified.
S&F Rolled Section of Fe 410-W (Gde E-250)-A as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for framed structure, fixed with angle cleats or other connecting plates all as specified.
S&F Expanded metal mesh, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to steel members, mesh not less than 4 kg per sqm complete all as specified.
Demolation of reainforced cement Concrete of any description and in any position not otherwise specifically provided complete all as specified.
M&L in replacement of earthing with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note (i)The earth pit shall be refilled by boulders free from vegetable soil. (ii) Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after satisfactory test result.
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified.
Supply and installation, testing and commissioning in replacement of pump set control panel board suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 200A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 75 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1000x1000x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by manufacturer will be approved by Accepting Officer before placing order. INCOMING:- (a) MCCB 4P, 25KA, 100 Amps, 415 Volts - 1 No (b) Digital volt meter 0-500 V -01 Nos (c) Digital Amp Meter - 0-200 Amp - 01 Nos (d) Indicator lamps LED type set of three -01 Nos OUTGOING:- (a) MCB TPN 415 Volt 10 KA 'B' 63 Amp - 2 Nos (b) Star Delta Starter with Auto Unit 13 -21A relay having Phase failure, Phase inbalance, Phase reversal ,Short Circuit Protection Through MCB- 2 Nos (c) Digital Amp Meter - 02 Nos (d) Indicator lamps LED type set of three -02 Nos
M&L for providing SWT identification board made out of MS sheet of size 600x300x6mm and fixed with angle iron 40x40x5mm. 150 cm long duly painted with black paint and marking the SWT number and arrow sign of both side with white paint including grouting the angle iron in PCC 1:3:6 compelet all as specified as directed.
Supply, installation and testing in replacement flanged ended analog type water meter (ISI Marked) Class 'B' of size 250 mm dia bore (10") making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/vertical position, compelet all as specified as directed. Note :- The cost of blank flange is deemed to be included in quoted rates.
All as per Item Ser No 161.00 above but meter of size 200 mm dia bore (8")
All as per Item Ser No 161.00 above but meter of size 150 mm dia bore (6")
Shri Electrical Enterprises
Anil Builders
naveen enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .