Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.2 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 Being lowest | |
| 2 | L2₹63.2 L+₹2.0 L (3.26%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹63.9 L+₹2.6 L (4.30%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹64.8 L+₹3.5 L (5.78%)Rejected-Finance NEAR NATRAJ MANDIR NEW INDIA COLONY PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹67.4 L+₹6.2 L (10.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹74.4 L
EMD Value
₹1.4 L
Closing Date
9 Dec 2023, 6:00 pmClosed
Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone
COMPLETION OF LEFT OVER WORK FOR PROVN OF RAPID SAND FILTRATION PLANT OF CAPACITY 5 LPGD ALONGWITH CONNECTED ITEMS AT PALAMPUR
2023_MES_608511_2
CA NO. CEPZ-12/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE PALAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
Yes
GE PALAMPUR
₹1.4 L
Yes
18 Jan 2024
30 Oct 2023
16 Dec 2023
30 Oct 2023
9 Dec 2023
25 Nov 2023
Amount
Excavation over areas in any type of soil not exceeding 1.5m deep and getting out complete all as specified and as directed.
Excavation over areas in any type of soil exceeding 1.5m but not exceeding 3.0m deep and getting out complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil for laying of cable, pole foundation, stay, laying of pipe etc. complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed.
Reinforced cement concrete M-25, design mix (using 20 mm graded aggregate) as in foundations, including rafts footings, foundation beams, plinth beam, bases for columns etc, complete all as specified and as directed.
Reinforced cement concrete M-25, design mix (using 20 mm graded aggregates) as in columns, pillars complete all as specified and as directed.
Reinforced cement concrete M-25, design mix (using 20 mm graded aggregate) as in beams, cantilivers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
Reinforced cement concrete M-25, design mix (using 20 mm graded aggregate) as in spiral staircases (including landings) complete all as specified and as directed.
Reinforced cement concrete M-25 (Design mix), (using 20 mm graded aggregate) as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves etc complete all as specified and as directed.
Reinforced cement concrete M-30, design mix (using 20 mm graded aggregates) as in walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttresses complete all as specified and as directed.
Reinforced cement concrete M-30, design mix (using 20 mm graded aggregates) as in columns, pillars, piers, posts and struts etc complete all as specified and as directed.
Reinforced cement concrete M-30, design mix (using 20 mm graded aggregate) as in beams, cantilivers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
Reinforced cement concrete M-30, design mix (using 20 mm graded aggregate) as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves etc complete all as specified and as directed.
Supply for liquid water proofing compound complete all as specified and as directed.
Formwork to sides of concrete foundation, footings bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical to rough finished surface of concrete complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular or polygonal shape etc, rough finished surface of concrete complete all as specified and as directed.
Formwork to RCC Wall face flat rough finished surface of concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc, also splays between floors and beam, etc, to rough finished surface of concrete complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping) complete all as specified and as directed.
Formwork to spiral staircase with sloping or stepped soffits including risers and stringers (excluding landing) square, rectangular rough finished surface of concrete complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide to rough finished surfaces of concrete complete all as specified and as directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
All as per item No. 22 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and as directed.
Brick work with fly ash brick having crushing strength not less than 75Kg/sqcm, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
Rendering15mm thick in cement mortar 1:3 on fair faces on fair faces of concrete surfaces finished the surface even and smooth without using extra cement on internal wall surface complete all as specified and as directed.
Rendering 10mm thick in cement mortar 1:3 on fair faces on fair faces of concrete surfaces finished the surface even and smooth without using extra cement on ceiling surface complete all as specified and as directed.
Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread levelled and rammed including watering complete all as specified and as directed.
Broken stone hardcore of gauge not exceedding 63mm, deposited spread and levellied in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified.
75 mm thick Plain cement concrete 1:4:8 type D-2 (40 mm graded aggregate) as in sub-base complete all as specified and as directed.
75 mm thick PCC 1:3:6, type C-2 (using 20mm graded crushed stone aggregate) as in plinth protection etc and finished fair and even surfaces without using extra cement complete all as specified and as directed.
40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as flooring, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
Supply only glass dividing strips 38 mm width and 3 mm thick complete all as specified and as directed.
25 mm thick Plain cement concrete 1:2:4, type B-O (using 12.5 mm graded crused stone aggregate) as in floors finished rough to receive floor finishes complete all as specified and as directed.
Non- skid ceremic coloured tiles 7 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles 300 mm x 200 mm and 5 to 6 mm thick as in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 to receive tiles complete all as specified and as directed.
Second class, hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joint complete all as specified and as directed.
35 mm thick second class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
35 mm thick second class hardwood glazed and skeleton shutters , open rebated and prepared to receive glass, guaze, etc.(without sash bars), edges of framing plain chamfered or rounded fitted with cut and metered beads for securing glass etc. sizes of members of shutters as specified in SSR-I , section-8, clause-8.24(a); supplied and fitted to chowkats complete all as specified and as directed.
30 mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, guaze, etc.(with sash bars), edges of framing plain chamfered or rounded fitted with cut and metered beads for securing glass etc. size of members of shutters for windows, ventilators, etc are provided with stiles and rails as specified in SSR-I , section-8, clause-8.24(b) complete all as specified and as directed.
100 mm size butt hinges medium weught , cold rolled mild steel complete all as specified and as directed.
75 mm size butt hinges medium weught, cold rolled mild steel complete all as specified.
150 mm size aluminium anodised, barrel tower bolts, of extruded section complete all as specified and as directed.
200 mm size aluminium anodised, barrel tower bolts, of extruded section complete all as specified and as directed.
150 mm size Handles extruded aluminium alloy handles,fabricated type anodised complete all as specified and as directed.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast-aluminium alloy complete all as specified and as directed.
Second class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door/windows stops and the like, including all necessary' labours; articles not exceeding 200 Cu. cm each including butt hinges, size 50 mm, medium weight, cold rolled mild steel complete all as specified and as directed.
4 mm thick sheet glass, ordinary quality and glazing with oil putty/ beading in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Steel work such as in hold fasts conforming to similar articals Fe-290 Gde E-165 complete all as specified and as directed.
Plain cement concrete type B1, 1:2:4 (using 20mm graded stone gregate) as in hold fasts/ bed blocks/ coping etc. complete all as specified and as directed.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and as directed.
Applying two coats of synthetic enamal paint over a coat of pink primer on wood/wood based surfaces over 10cm width or girth including preparation of new wooden surface complete all as specified and as directed.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes,framed guard bars; barred iron doors,ladders, framed balusters, walk ways,railings, framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed.
Preparation of new steel surface of any description over 10 cm in width or girth, not otherwise description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparing of new plastered wall surface and applying three coat white wash on newly plastered surfaces complete all as specified and as directed.
Preparing of new plastered ceiling surface and applying three coat white wash on newly plastered surfaces complete all as specified and as directed.
Preparing of new plastered surface and applying three coat cement base paint on newly plastered surfaces complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and wall ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated material exceeding 250mm but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point concrete complete all as specified and as directed.
RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttress complete all as specified and as directed.
80mm bore PVC (SWR) pipes as in weep holes in RCC retaining wall etc complete all as specified and as directed.
Broken stone or boulder filling hand packing (any thickness at the back of walls) etc. and raising to the required level complete all as specified and as directed.
Point wiring with 1.5 sqmm copper conductor cables (multistanded), PVC insulated (FRLS), unsheathed in and including concealed PVC conduit not less than 1.8mm thick (ISI marked) heavy duty of adequate size with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated steel top cover for one light/fan/bell point controlled by one, one way switch including continous 1.5 sqmm copper conductor (multistranded) PVC FRLS insulated and unsheathed cable as earth wire and connected to earth dolly complete all as specified and as directed.
All as per item No 64 here-in-before but for one 3 pin socket outlet 5 Amps independent complete all as specified.
Switch piano flush button, 5 Amps, 240 Volts complete single pole one way complete all as specified and as directed.
Socket out let 2 in 1, 3 Pin 5 Amps flush type complete all as specified and as directed.
Ceiling rose surface type bakelite 50mm x 65mm, two to three terminals complete all as specified and as directed.
Lamp holder, insulated body, with back plate for batten fitting with LED Lamp 10 Watt, complete all as specified and as directed.
LED channel with powder coated CRCA sheet housing for suitable for 1x18 Watt LED T8 lamp with LED tube light 18 Watt in PC housing with high efficient LEDs including provn of flexible cable 3 core, 23/.0076 from ceiling rose to fitting complete all as specified and as directed. Makes for LED channel : Halonix, Cat Part No HILB04-118 LED or equivalent in Bajaj/CG/Havells/Wipro/Polycab Makes for LED tube light : Halonix, Cat Part No HLTLD-NI03-18-CW-PC or equivalent in Bajaj/CG/Havells/Wipro/Polycab
LED Bulk Head 10W with pressure die cast aluminium housing, high efficient LEDs and enclosed with milky diffuser IP66 complete all as specified and as directed. Makes:- Halonix, Cat Part No HLBH-02-10-CW or equivalent in Bajaj/CG/Havells/Wipro/Polycab
Ceiling fan 1200 mm sweep, 240 Volt, 50 Hz complete all as specified and as directed. Makes:- Havells, Model - ES 5* rating or equivalent in Bajaj/Usha/Khaitan
Stepped type electronic fan regulator flush type suitable for 240 Volts AC, 100 Watt complete all as specified and as directed.
Exhaust fan 450mm sweep, single phase,50 Hz ,1400 RPM heavy duty with louver shutter and connecting with electrical system incl provn of cable copper flexible, PVC three core 23/0.0076 from ceiling rose to fan complete all as specified and as directed. Makes:- Havells/Bajaj/CG
Sheet metal enclosure powder coated DB for fixing of MCBs, SPN 4 ways double door, IP-42 protection with 200 Amp rated bus bar, 240 Volts complete all as specified and as directed. Make:- Havells/Indo Asian/ L&T
Miniature circuit breaker (MCBs) single pole and neutral, 240 Volts 'B' series, 10 KA, 16 Amps complete all as per specified and directed. Make-: Havells/L&T/Indo Asian
Miniature circuit breaker (MCBs) single pole , 240 Volts 'B' curve type 10 KA, 6 to 32 Amps complete all as per specified and directed. Make:- Havells/L&T/Indo Asian
Submain wiring with two runs of FRLS PVC insulated of 2.5 Sqmm multistranded copper conductor unsheathed cables, in and including concealed PVC conduit of not less than 1.8mm thick (ISI marked) of adequate size including FRLS PVC insulated multistranded copper conductor unsheathed cable of size 2.5Sqmm as earth wire 1100 Volts Grade from main panel to DB complete all as specified and as directed. Note:- One run of three wires (Phase, neutral & earth ) including PVC coduit will be measured as one metre.
Removal of excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Ductile iron pipe (Conforming to IS- 8329 :2000) with spigot and socket ends of bore 200mm special class K-9 suitable for tyton joint including tyton joints & jointing material laid in trenches complete all as specified and directed.
Fixing only ductile iron fittings for ‘DI’ pipe (conforming to IS-9523:2000) Such as Bends, collars, Tapers, Tee pieces (Single & double Branch) any and angle/radius and straight connecting pieces upto 200mm dia including jointing material complete all as specified and directed.
Fixing only MS lateral 20 Nos (Heavy grade) in filter bed made out of 80mm dia of length 1.3 Mtr each, one end threaded and other end closed including 500 mm dia MS manifold and making 12mm dia holes 20 nos in each lateral pipe and fixing with manifold MS pipe 01 No of size 500mm dia of length 3.7 Mtr duly welded MS socket 20 Nos of 80mm dia suitable for fixing lateral pipe 80mm dia complete all as specified and as directed.
Fixing only Galvanised iron water tubing 80mm bore, heavy grade (ISI marked) with all fittings such as bends, elbows, tees, short pieces etc and laying in trenches/floor suitable for Air blower for back wash, complete all as specified and directed.
Fixing only MS pipe of size 200mm dia, not less than 4.80mm thick suitable for wash out line of filter plant complete all as specified and directed.
Fixing only cast iron sluice valve long body type, both ends flanged and drilled, of size 80mm bore, (ISI marked) conforming to IS-14846 -2000 with pressure rating of PN-1.0 with brass spindle and iron wheel head complete all as specified and directed.
Fixing only cast iron sluice valve long body type, both ends flanged and drilled, of size 150mm bore, (ISI marked) conforming to IS-14846 -2000 with pressure rating of PN-1.0 with brass spindle and iron wheel head complete all as specified and directed.
Fixing only cast iron sluice valve long body type, both ends flanged and drilled, of size 200mm bore, (ISI marked) conforming to IS-14846 -2000 with pressure rating of PN-1.0 with brass spindle and iron wheel head complete all as specified and directed.
Installation and testing of Air Blower of capacity 480 cum/hr, 1845 RPM complete suitable for 15 HP motor includung motor 15 HP, 3 phase, 415 volts, 1845 RPM of Model of Blower-S2H52 of Make-Ingersoll Rand complete all as specified and directed. Makes of Motor:- CG or equaivalent in Kirloskar /Crompton (Note For item No.81 to 88 . The material / fittings for these items shall be issued under Sch 'B' FREE FOR FIXING).
Supply and laying in layers gravels duly cleaned and washed of size 25mm in layer of thickness 250mm (Bottom layer).
Supply and laying in layers gravels duly cleaned and washed of size 20mm in layer of thickness 150mm (Intermediate layer).
Supply and laying in layers pea gravels duly cleaned and washed of size 2mm to 5mm in layer of thickness 200mm (Top layer).
Supply and filling in layers coarse sand (Barakar River Sand) grains of size 1.5mm to 5mm suitable for filter plants of depth 600mm (sand shall be HCL free and HCL acid test carried out from Govt approved lab), complete all as specified and directed.
Supply and fix Galvanised iron water tubing 150mm bore (medium grade) suitable for water inlet into filter plant with all fittings such as bends, elbows, tees, etc and laying in trenches/floor complete all as specified and directed. Notes : - (a) Earth work shall be measured & paid under relevant item. (b) The cost of new fitting alongwith cutting, threading as required shall be deemed to be included in the rate quote.
Supply, fix & welding MS flange having thickness not less than 10mm for 200mm dia MS pipe duly holes drilled matching with the holes of flanges of sluice valve complete all as specified and directed.
Supply, fix & welding MS flange having thickness not less than 10mm for 150mm dia MS/GI pipe duly holes drilled matching with the holes of flanges of sluice valve complete all as specified and directed.
Supply, fix & welding MS flange having thickness not less than 10mm for 80mm dia MS/GI pipe duly holes drilled matching with the holes of flanges of sluice valve complete all as specified and directed.
Flange joint with rubber gasket not less than 3mm thick including suitable size of MS nuts, bolts & washers suitable for size 200mm dia bore complete all as specified and directed.
Flange joint with Rubber gasket not less than 3mm thick including suitable size of MS nuts, bolts & washers suitable for size 150mm dia bore complete all as specified and directed.
Flange joint with Rubber gasket not less than 3mm thick including suitable size of MS nuts, bolts & washers suitable for size 80mm dia bore complete all as specified and directed.
Self priming monoblock pump 1.0 HP , single ph suitable to take out leakage water from filter plant complete all as specified and directed. Makes:- Kirloskar/ CG
Supply and fix wafer type Swing check valve of size 100mm dia in air blower line complete all as specified and as directed.
Supply, installation, connecting and testing of Chemical Dosing System alongwith injector pressure 5.5 Kg / sqcm and max output (flow rate ) 5 ltr/hrs with the following specification:- (a) Preparation Tank (Model No-VST 1005) : Tank of capacity 170 ltrs of FRP dosing tank 650mm x net height 375mm + conical 300mm gross height with stand 100mm consisting of :- (i) Water Inlet line, (ii) Outlet with `Y' strainer, (iii) Drain, (iv) Over flow, (v) Conical bottom for sludge deposition (vi) Pot hole with cover, (vii) Level gauge, (viii) Agitator 120W, 900 RPM, 1 phase flange mounted motor with plastic shaft and Impeller. (b) Service Tank (Model No-VST 1006) :Tank of capacity 100 ltrs of FRP dosing tank of top dia 540mm x bottom dia 480mm x height 575mm consisting of :- (i) Water Inlet line, (ii) Outlet with `Y' strainer, (iii) Drain, (iv) Over flow, (v) Level gauge, (vi) Agitator 120W, 900 RPM, 1 phase flange mounted motor with plastic shaft and Impeller (vii) Provision of mounting pump on lid/wall Makes:- VARIMA or equaivalent in other make.
Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles or passing through pipes 1100 volts grade XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) with stranded aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and directed. Note:- Excavation, earthwork, sand cushion and cable protection items shall be measured and paid under relevant items
Supply, laying, jointing and testing FRLS PVC insulated single core multistranded copper conductor cable of size 2.5 sqmm , 1100 volts grade with electric motor by using suitable lugs complete all as specified and directed.
Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable and punning down complete all as specified and as directed. Note:- Punned thickness 18cm shall be considered for measurement purpose.
Un-reinforced precast concrete cable cover, factory made, Class LV, Type 2 as per IS 5820-1970, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Fabrication of MS gate of size 600mm x 450mm with thickness of gate not less than 10mm thick complete with fabrication work for holding of gate & grouting 04 Nos angle iron pieces of 50mmx50x6mm in such a way to enable 10mm thick MS plate shutter can slide freely to be fixed in water channel of existing sedimentation tank complete all as specified and directed.
Supply, installing, testing and commissioning of cubical indoor type, floor mounted, factory fabricated LT panel board suitable for 3 phase, 4 wire, 415V, 50 Hz with 2mm thick CRCA sheet steel,totally enclosed dust & vermin proof, IP-55, capable to accomodate incomer/outgoing MCCB's/ MCB, TPN/TP & starters , aluminium bus bar of rating 1.5 times the rated capacity of incomer, insulated with heat shrinkable sleeves with 1 No. voltmeter and amp meter with one set of RYB indicating LED type lamps, FM, all protection ie single phase protection, high voltage, low voltage etc complete all as specified & directed, comprising of following:- (i) Bus bar TPN 100Amps - 1 set (ii) Incoming MCCB 63 Amp, 4 Pole- 01 No (iii) MCB 16Amp SPN -01 No ( For bldg light) (iv) Soft starter 15 HP, 3ph for pumping set - 02 Nos (v) DOL starter 1 HP, single ph for pumping set -01 No
Galvanised wate tubing 80 mm bore, medium grade (ISI marked) with all fittings such as bends, elbows, tees, short pieces, caps plugs and unions etc and laying in trenches/floor suitable for connecting existing OHT to back wash system complete all as specified and directed.
Cutting existing GI pipe line of size 150 mm in position (two cuts) by any means for insertion of new tee of size 150mm x 150mm x 80mm for branch connection including necessery fittings and making joints with jointing material as per site requirement etc. complete all as specified and directed. Note:- Excavation, returning filling in and removing shall be measeured and paid for separatly under respective items.
Earthing complete with galvanized steel earth plate electrode 60cmx60cm and 6mm thick buried directly in ground (Earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to including galvanised iron or steel earth strip 32mmx6mm by means of nut bolts, check nuts and washers incl GI pipe 20mm dia light grade as water pipe and connected to equipment/ panel including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 30cm x 30cm x 40mm with reinforcement by XPM having 4 kg/sqm, angle size 40mm x 40mm with 6 mm dia MS bar handle, provision of funnel, wire mesh, 40mm bore galvanised steel tubing (Medium grade) for protection of earth strip, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete all as directed.
Excavating over areas in any type of soil exceeding 3.0m but not exceeding 4.50m deep and getting out complete all as specified and as directed.
Demolition of RCC of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for making joints etc, portions ordered to be dismantled complete all as specified and directed by Engineer-in-Charge.
Separating, scraping and cleaning of reinforcement from existing framed structure of reinforced concrete (Demolition of concrete measured separately under respective item) complete all as specified and as directed by Engineer in Charge.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
All as per item No 115 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Cutting upto a depth of 10 cm into concrete walls and trimming surfaces as required, girth exc. 30cm complete all as specified and directed by Engineer-in-Charge.
Removal of rubbish and debris from premisies and cleaning of any dirt which may result from previous executed work to a distance n exc 50m complete all as specified and as directed by Engineer-in-Charge.
Cutting upto a depth of 2.5 cm into concrete walls and trimming surfaces as required, girth exc. 30cm complete all as specified and directed.
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 45,365/- shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SINGH AND ASSOCIATES
RSP Contractors India Private Limited
D R CONTRACTORS
JYOTI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .