Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹3.2 L+₹12,191.04 (3.93%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | L3₹3.3 L+₹16,268.31 (5.25%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | ||
| 4 | L4₹3.4 L+₹33,841.34 (10.9%)Admitted-Fee/PreQual/Technical/Finance | L4 | Admitted-Fee/PreQual/Technical/Finance | ||
| 5 | L5₹3.6 L+₹52,515.24 (16.9%)Admitted-Fee/PreQual/Technical/Finance | L5 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.1 L
EMD Value
₹4,100
Closing Date
22 Sept 2026, 5:00 pmClosed
Divisional Officer
O/o The Superintending Engineer, Phulbani (R and B) Division, Phulbani, Kandhamal, 762001
S/R to E.I of Flood Lights at Outdoor Stadium, Kandhamal Buildings.
2026_EICCL_140187_1
SERBPLB3-08-2026-2027
Open Tender
Electrical Works
Percentage
30 days
Kandhamala, Phulbani
2 documents required · 2 mandatory
₹2,000
₹4,100
23 Sept 2026
10 Sept 2026
23 Sept 2026
10 Sept 2026
22 Sept 2026
10 Sept 2026
10 Sept 2026 - 19 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of single die-cast housing (modular type is not allowed) LED Flood Light with a minimum system lumen output of 60K lm or higher and nominal efficacy of 120 lumen/watt or higher(500 Watt). CCT of 5700K with SDCM of Less than 5 and CRI greater than equal to 80. The housing should be of non-corrosive high-pressure die-cast aluminum (ADC12) to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF greater than 0.95, THD less than10%. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have n internal surge protection of 4kv and 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. .The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature.. The driver control panel box should be outdoor type and shall be forced ventilated with industrial grade outdoor fans with working and standby. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, Make-Panasonic/Philips/Bajaj/LT/Wipro/ Crompton/Havells | 3 | set | 42,670 | ₹1,28,010 |
| 2 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. | 5 | nos | 3,681 | ₹18,405 |
| 3 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) | 2 | set | 8,156 | ₹16,312 |
| 4 | SITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of less than 5 and CRI greater than equal to 80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF greater than 0.95, THD less than 10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be greater than equal to 500 LUX ,min to average shall be greater than equal to 0.7, min to max shall be greater than equal to 0.5 Only sport series flood light will be accepted.
Make- Philips/ Lighting Technologies/ Schréder | 14 | nos | 17,500 | ₹2,45,000 |
stage.html
html • 0.02 MB
finance_608154.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 0.70 MB
Tendernotice_1.pdf
PDF • 1.73 MB
BOQ_608154.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .