| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being Lowest. | |
| 2 | L2₹32.9 L+₹2.0 L (6.39%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Rejected being not lowest. | |
| 3 | L3₹34.0 L+₹3.0 L (9.68%)Rejected-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L3 | Rejected-AOC Rejected being not lowest. | |
| 4 | L4₹34.8 L+₹3.8 L (12.4%)Rejected-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L4 | Rejected-AOC Rejected being not lowest. |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
20 Apr 2021, 5:00 pmClosed
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
REPAIR/MAINT AND DEHYDERATION OF TRANSFORMER AND ALLIED HT WORKS INCLUDING REPAIR/MAINT/REPLACEMENT OF HT RMU PANEL, OVB, VCB AND CAPACITOR BANK AND OTHER CONNECTED ITEM IN ROORKEE AND PURKAZI UNDER GE ROORKEE
2021_MES_418492_2
95109/RKE/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Roorkee
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Roorkee
₹70,000
12 Jun 2021
16 Mar 2021
22 Apr 2021
16 Mar 2021
20 Apr 2021
30 Mar 2021
Amount
Disconnecting defective transformer indoor/outdoor of capacity 750KVA both from HT/LT sides, and then drainage of complete transformer oil, opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs. Note :- (i) The cost of transportation shall be deemed to be included in the quoted rate by the conractor. (ii) The cost of rewinding shall be paid separately. (iii) The cost of dehydration/filtration & other necessary repair as directed shall be measured & paid separately under relevant items of this schedule. (iv) Additional transformer oil for top-up, if required will be filled by contractor and shall be paid under respective item of this schedule.
Disconnecting defective transformer indoor/outdoor of any capacity up to 315KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed by Engr-in-Charge.
Disconnecting defective transformer indoor/outdoor of any capacity up to 315-500 KVA both from HT/LT sides, and then drainage of required transformer oil. Opening of top cover LT and HT side bushings with due care and removal of all HT/LT winding connections from bushing and then replacement of head gasket, LT and HT bushing packings complete and ensured that no leakage in transformer from LT/HT bushing and top cover gasket as directed by Engr-in-Charge.
Taking down of power transformers any capactiy from PCC plateform with due care after disconnecting all HT/LT connections, Transportation of transformer to workshop from site of installation to workshop for repairs including loading and unloading of transformer, and replacing it to site from where it was taken for repairs/(as required by Engr incharge) complete .and then lowering it by means of crane and remounting on platform after repairs including testing with connected all type connection all as directed and specified by engineer in charge.
Taking down of transformers of capacity 50/100/250/300/400/500/750KVA from 2/4pole structure or from PCC plateform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to workshop from site of installation to workshop for repairs including loading and unloading of transformer (with the help of Hydra), and replacing it to site from where it was taken for repairs (as directed by Engr incharge) complete .and then lowering it by means of crane and remounting on 2/4pole structure after repairs all as directed and specified by engineer in charge.
Taking down of transformers of capacity 50/100/250/300/400/500/750KVA from 2/4pole structure or from PCC plateform with due care after disconnecting all HT/LT connections on pole mounted structures, Transportation of transformer to PCC/ 2 or 4 pole structure to any other required location in Roorkee cantt lowering and remounting it on 2/4pole structure by means of crane after disconnecting all connection and reconnection in new location including earthing connection and as directed and specified by engineer in charge.
Material and labour for replacement of worn out HT side copper coils for Transformer rating 50-315 KVA made out of super enameled insulated copper wire all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed by engineer in charge
All as per Item No. 7 above but of Transformer rating 315-500 KVA.
All as per Item No. 7 above but of Transformer rating 750 KVA.
Material and labour for replacement of worn out LT side copper coils for Transformer rating 50-300 KVA made out of super enameled insulated copper strip all as per existing size and shape including all insulating, binding, material and then varnishing complete all as specified and directed by engineer in charge
All as per Item No. 10 above but of Transformer rating 315-500 KVA.
All as per Item No. 10 above but of Transformer rating 750 KVA.
Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 2.4 mm gap the BDV should be 40KV complete all as specified and directed by engineer in charge.
Supplying,filling dehydration and filtration of new transformer oil for toping up/replacement of transformer oil having dielectric strength not less than 40 KV(rms) with gap of 2.5 mm all as conforming to IS 335 of 1993 complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of worn out bushing rod made out of brass with heavy duty three nuts and three washer of brass at both ends suitable for HT side all as per existing size, shape, dia and length suitable for following capacity transformers :- (a) 50 - 100 KVA
(b) 160 – 200 KVA Transformers.
(c) 315 – 400 KVA Transformers.
(d) 500 -- 750 KVA Transformers
Material and labour for replacement of worn out bushing rod made out of made out brass with heavy duty three nuts and three washer at both ends suitable for LV side all as exiting size, shape and length suitable for following capacity transformers :- (a) 50 - 100 KVA Transformers
(b) 160 – 200 KVA Transformers.
(c) 315 – 400 KVA Transformers.
(d) 500 -- 750 KVA Transformers
Material and labour for replacement of worn out porcelain bushing for 11KV HT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:- (a) 50 – 100 KVA Transformers
(b) 160 – 200 KVA Transformers.
(c) 315 – 400 KVA Transformers.
(d) 500 -- 750 KVA Transformers
Material and labour for replacement of worn out porcelain bushing for .433 KV LT side indoor /outdoor transformers with rubberised cork sheet washers 4mm thick all as required at site and as directed by engineer in charge suitable for following capacity transformers:- (a) 50 – 100 KVA Transformers
(b) 160 – 200 KVA Transformers.
(c) 315 – 400 KVA Transformers.
(d) 500 -- 750 KVA Transformers
Material and labour for replacement of worn out rubberised cork sheet 4mm thick for transformer top cover all as required at site and as directed by engineer in charge suitable for following capacity transformers:- (a) 50 – 100 KVA Transformers
(b) 160 – 200 KVA Transformers.
(c) 315 – 400 KVA Transformers.
(d) 500 -- 750 KVA Transformers
Material and labour for replacement of worn out rubberised cork sheet 4mm thick suitable for HT/LT side bushing of off sizes all as required at site and directed by engineer in charge.
M & L for Preparation of old surface of power transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun and writing SM No on transformer in capital letter at site of installation of transformer complete all as specified and directed by engineer in charge suitable for following capacity of transformer:- (a) 2 MVA
M & L for Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun and writing SM No on transformer in capital letter at site of installation of transformer complete all as specified and directed by engineer in charge suitable for following capacity of transformer:- (a) Upto 160 KVA.
Material and labour for replacement of worn out silica gel breather assembly including silica gel all as per existing sample suitable for following capacity of transformers of any make.:- (a) 2 MVA.
Material and labour for replacement of worn out off load tap changer, with matallic tap changing machanizm, 7 positions and making all electrical connection including removing existing one complete all as per existing sample suitable for following capacity of transformers of any make.:- (a) 50 -100 KVA
Material and labour for special earthing to substation equipment with GI earth plate 600X600X6mm buried directly in ground vertically to a depth not less then 4.5Mtr depth below ground level. Earth plate shall be surrounded with adequate quantity of charcoal dust with common salt packed 250mm on all sides of earth plate including excavation , earth work in any soil, returning filling in removal of surplus soil to a distance up to 50Mtrs, concrete pit and RCC cover with suitable handle for lifting and GI strip 32X6 mm soldered and riveted to earth plate at one end and brought up to test point including 50mm bore GI protaction pipe and 20mm dia light grade pipe for watering all as specified and shown in drawing, complete all as specified and directed by Engineer in charge.
Material and labour for oil temperature guage / thermometer (0 degree to 120 degree C) suitable for transformers all as per existing shape and size for any make and model of transformers all as specified and directed by engineer in charge.
M&L for XLPE insulated screened PVC bedded galvanised steel strip or armoured eletric power cable ( heavy duty) with aluminium conductor 11000 V grade cross sectional area 185 sq mm 3 core. Make :- Havells, Polycab, Finolex
M&L for XLPE insulated screened PVC bedded galvanised steel strip or armoured eletric power cable ( heavy duty) with aluminium conductor 11000 V grade cross sectional area 120 sq mm 3 core . Make :- Havells, Polycab, Finolex
Exacation in trenches n exc 1.5 Mtr and n exc 1.5 Mtr wide in soft/loose soil complete all as specified and directed..
M&L for sand cushioning for cable protection complete all as specified and directed.. .
Returning filling spreading levelliong and well ramming watering in layer n exc 1.5 Mtr complete all as specified and directed..
Removing of excaveted material n exc 50 Mtr and depositing where directed at a level complete all as specified and directed..
Supply and laying in replacement of reinforced precast concrete cable cover class HV, type-1, flat size 300x180x40mm for protection of UG cable complete all as specified and directed.
Supply testing jointing and commissioning of Cold shrinkable type straight through joint kit and incl jointing materials suitable for cable size 120- 185 sq mm 3 Core X LPE 11 KV cable complete all as specified and directed . Make- Raychem/ Dension/ Mseal
All as per item above but suitable for cable size 70-95 sq mm 3 core XLPE 11 KV cable
Supply testing jointing and commissioning of indoor Cold shrinkable end tremination joint kit and incl jointing materials suitable for cable size 120-185 sq mm 3 Core X LPE 11 KV cable complete all as specified and directed . Make- Raychem/ Dension/ Mseal
Supply testing jointing and commissioning of outdoor Cold shrinkable end tremination joint kit and incl jointing materials suitable for cable size 120 to 185sq mm 3 Core X LPE 11 KV cable complete all as specified and directed . Make- Raychem/ Dension/ Mseal
Supply testing jointing and commissioning of outdoor Cold shrinkable end tremination joint kit and incl jointing materials suitable for cable size 70-95 sq mm 3 Core X LPE 11 KV cable complete all as specified and directed . Make- Raychem/ Dension/ Mseal
Supply testing jointing and commissioning of outdoor Heat shrinkable end tremination joint kit and incl jointing materials suitable for cable size 50 sq mm 3 Core X LPE 33 KV cable complete all as specified and directed . Make- Raychem/ Dension/ Mseal
M&L for lightning arrestor expulsion type complete with all fittings transmission c lass discharge capacity 65 Kiloampere suitable for 11000 V grade .
Supply, installation, testing and calibration of Digital protective relays comprising of 3 Phase, over current plus earth fault relay with high and low set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model MC 61A as per Cat Part no-MC 61 Anx of L&T including complete wiring with suitable size wire as per existing and fixing arrangement complete as specified and directed. Make :- CG, Jyoti, AE, Ashida
S&F as in replacement Digital protective relays comprising of over current plus earth fault relay with high set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model ADR 131A of Ashida make including complete wiring with suitable size wire as per existing and fixing arrangement complete as specified and directed. Make :- CG, Jyoti, AE, L&T
S&F as in replacement Digital protective relays comprising of under / high voltage relay with with high set operational with 24 volt to 110 volts AC / DC, Dc dual rated CT model ADR 132B of Ashida make including complete wiring with suitable size wire as per existing and fixing arrangement complete as specified and directed. Make :- CG, Jyoti, AE, L&T
Supply and fix vertical type air break gang operated tripple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators 09 Nos and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete.(set of three)
Supply and fix drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including insulators 12 Nos for 11 kv working pressure fixed to and including MS channel with nuts, bolts, and washer etc. Synthetic bounded fuse camng tube complete with line fap suitable for current carry capcity upto 100Amps all as directed. ( set of three)
Preventive maintenace/ servicing of HT RMU of make ABB by dismantling of breaker mechanism checking the various critical setting in mechanism, busbar chember,Electric short circuit indicator, current and earthfult relay, gas pressure/ densicty, manually operated mechanisms, fuses , fuse conister, feeder busbar intenal/external busbar, SF6 tank, LV copartment, auxiliary switch, interlocking lever, current transformer relay etc. checking of spring charging mechanism, checking of pole contact , greasing/ lubricating of mechanism moving parts, checking of contact pressure, alignment and adjusting the same, triping coil test trial & teting of RMU for smooth and correct fuctioning by ABB Engr or authorized coy complete all as specified and directed by Engr-in-Charge.
M&L in replacement of triping/ closing coils suitalbe for 33KV VCB Make : ABB
M&L in replacement of triping/ closing coils suitalbe for 11KV VCB Make : CG
Supply only anti rusting spray suitable for mechanical moving parts of 33/11 KV VCB & OCB.
M&L in replacement of oil tank gasket for 11KV OCB of make CG
M&L inreplacement of vent tank gasket for 11KV OCB of make CG
M&L inreplacement of hold on catch assembly for 11KV OCB of make CG
M&L inreplacement of Rectifier for motor circuit of 11KV VCB of make CG.
M & L inreplacement of U/S Trip coil RMU Make : Ashida Realy
M&L inreplacement of tripping shaft with spring and trip strip for 11KV VCB of make CG.
S&F HT bushing of RMU Make: ABB
Repair to mechanism switch system of 11 KV RMU as per diagram for earthing ,interlocking ,spring charging as directed by Engr in Charge.
S & Fill SF6 gas to be filled in HT RMU's 11000 volt grade complete all as specified and directed
S&F as in replacement of HV backup fuse link, CEF cap iN 16Amp i3 55 A, UN 12Kv i163 A, Striker 60N in SF6 RMU Make ABB cat part No IYMB631036M0003, complete all as spd and as directed. (set of Three)
S&F as in replacement of HV backup fuse link, CEF cap iN 25Amp i3 55 A, UN 12Kv i163 A, Striker 60N in SF6 RMU Make ABB cat part No IYMB5301035M0004, complete all as spd and as directed. (set of Three)
S&F as in replacement of HV backup fuse link, CEF cap iN 40Amp i3 55 A, UN 12Kv i163 A, Striker 60N in SF6 RMU Make ABB cat part No IYMB5301035M0004, complete all as spd and as directed. (set of Three)
Supply and fix horizontal Rotating type air break gang operated 400/600 Amp tripple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 33 KV porcelain insulators and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete.
Supply and fix drop out fuse unit explusion type for out door double stack chanal air break gang oprated switch single pole mounted on and including insulators for 33 kv working pressure fixed to and including MS channel with nuts, bolts, and washer etc. Synthetic bounded fuse camng tube complete with line fap suitable for current carry capcity upto 100Amps all as directed.
Supply and fix HT 33 KV outdoor non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure/GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth stripwith nut, bolt, washer transmission class having discharge capacity of 10 kilo Amps and suitable for working pressure complete all asspecified and directed complete.
M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing HT/LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed by Engr-in-charge.
M&L in repalcement of aluminium conductor, steel reinforced off sizes including binding wire and jumper connect with PG clamp (shape as per site requirement) made out of aluminium alloy accodring to IS-617 complete including nut, bolts and washers all as specified and directed by Engr-in-charge.
M & L for Caliberation of exisisting 4 pole Micro processor based digital programmer Protection relay unit of amy make and model having over current handling capacity up to 10 Amps for 10 milli sec and Earth fault arrest less then 04 mili sec to arrest the fault of individual VCB at site complete all as specified and directed by Engr-in-Charge.
S&F CT 11 KV VCB of Ratio 100-50/5+5, Class 1.0, VA 15 core 1 & core 2 , IL 12/28/75 KVP STC 18.4 KA for 1.0 Sec. complete all as specified and directed by Engr-in-Charge Make : Crompton Greaves.
Supply and Fixing inreplacement of unserviceble PT with new PT 11 KV oil/dry type as per existing make and type complete all as specified and directed by Engr-in-Charge Make : Crompton Greaves/ABB
M&L for High Tension cable fault checking by high tension cable fault testing machine by disconnecting the HT cable end termination including insulation testing complete of faulty cable.complete all as specified and directed by Engr-in-Charge.
Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular sweged poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-55(11.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed by Engr-in-charge. Note :- Excavation, MS work and PCC work will be measured and paid separately.
M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed.
M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate incl necessary form work all as specified.
M & L for cement concrete 1 :2 :4 type B-1 using 20 mm graded aggregate as in coping incl necessary form work all as specified.
Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and directeded.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in HT/LT underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed.
S & F in replacement pin type, porcelain, vitreous, white, brown or green insulator, including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150 mm height, 150 mm dia for 11000 Volt grade, complete all as specified.
S & F in replacement disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, with tension clamps for conductor, working pressure 11000 volts, complete all as specified.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of UG cable and repairing the road to match with the original finish by PCC 1:3:6 type C-2 using 40mm graded aggrigate complete all as specified.
Taking down old rusted galvanized iron pipe and providing galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. Make: Jindal/ Tata steel / Prakash Surya.
Materials and labour for 100mm thick plain cement concrete (1:3:6) type C2 using 40mm graded aggregate as in paving and spike rolling to surfaces or making impressions of expanded metal, complete all as specified and directed. (For MRS Yard maintenance)
Ansh Enterprises
u and v engineers and consultants
R N Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .