Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹12.0 L
Closing Date
8 Sept 2021, 3:00 pmClosed
Executive Engineer (Ele)
Electrical Division, Admin Building panambur, Mangaluru
Providing Electrification to the renovated Transit Shed No.1 at Berth No.2
2021_NMPT_644375_1
5/TrShed/EE(E)II/2021
Open Tender
Electrical Works
Works
90 days
New Mangalore Port Trust
Please refer Tender documents.
2 documents required · 2 mandatory
₹560
Yes
FA and CAO NMPT
Exempted
28 Oct 2021
19 Aug 2021
9 Sept 2021
19 Aug 2021
8 Sept 2021
26 Aug 2021
20 Aug 2021 - 23 Aug 2021
Supplying of 4Core x 4 sq.mm LT, UG cable having copper conductor PVC insulated sheathed, Galvanized, steel wire armored cable with PVC outer sheathing 1.1KV class
Supplying and drawing of 3C x 2.5sq.mm Flexible multi core cable manufactured flexible copper flexible PVC and insulated and sheathed 1100V grade cable from Marshaling box to lighting fixture
Supplying of PVC flexible conduit pipe 20mm dia for covering flexible cables fixing on wall by using heavy gauge saddles using NF screws etc complete
Labour charges for laying of 4core x 4 sq.mm armoured UG cable /on wall/structure as required with necessary saddles/clamps etc completed
Supplying and installation/fixing provision of box for MCB and CBT connectors for 3ph/1ph connections with loop-in and loop-out for terminating 4C x 4sq.mm branch out 3C x 2.5sq.mm copper cable enclosed in a 260x210x116mm thermo plastic polystyrene enclose it should be shock proof safe rust proof IP65 rust proof, dust proof, water proof having internally embedded Gasket with provision for cable entry through IP65 thermoplastic polyamide glands. Work including supply & fixing of 10 a DB MCB and 5Nos. M6 CBT connector and terminating the incoming and outgoing cables by using suitable lugs
Supplying and fixing angle iron frame work fabricated out of Ms angle iron of size 40x40x6mm and MS flat of 40x6mm with SS bolt, nuts washer etc. (or fixing as required at site), complete and painted with 2 coats of red oxide and then 2 coats of approved paint suitable for mounting light fitting
Supplying of 150W LED flood light fitting as per Technical Specification
Fixing of 150W LED flood light fitting over existing angle iron frame using SS bolts, nuts focusing to the working area wiring complete
Supplying of 4pole, 100A, 25KA, MCCB
Supplying of 16A, DP MCB’s
Supplying of 16A single pole MCB’s
Supplying of M6 CBT connectors LMR
Supplying of 3pole 60A contactors
Supplying of Electromechanical Time switch 24Hour programmer
Supply, Installation and fixing of Thermoplastic Modular Panel enclosure of size 600 x 600 x 170mm with transparent polycarbonate lid, shock proof, IP65 weather proof, rust proof, dust proof, water proof, corrosion proof having internally embedded, gasket on both lid and flap with Hylum sheet (for fixing the component inside the box) suitable to fix 125A, 25A, MCCB, MCBs and CBT connectors work including fixing the enclosure in the existing wall and fixing of CBT connectors. Work including supply of suitable rails (for fixing MCBs timer and CBT connectors) glands, fork busbar for MCBs neutral link (Bolt and nut type) and all wire and internal wiring in the enclosure by using suitable materials (such as wire and lugs) and provision for 3.5Cx95sq.mm cable gland for incomer and glands for 4Rx4Cx4sq.mm outgoing cable. The connection between MCCB to contactor and contactor to MCBs should be through 16sq.mm flexible copper wire and other wiring (from MCB to connector) through 6sq.mm copper wire with required lugs from MCB to connector, complete
Supplying and fixing earth electrode for grounding of light circuits, using 40mm dia., 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh and suitable –SBC reducer fixed on top of earth electrode. The funnel should be enclosed in CC chamber of 400x400x100mm with cast iron cover. The earth electrode shall have staggered holes of 12mm dia. And the electrode should be coved 150mm around pipe complete depth with alternate layers of salt and charcoal. The connection from the electrode is to be established through 25x3 copper flat using GI bolts and nuts
Supplying and running 25x3mm copper strip for grounding connection using fixing materials as required
Supplying and running 4sq.mm PVC insulated multi strand single core copper wire in open system for grounding connection using fixing materials as required
Supplying of LT UG cable of size 3.5Cx95 sq. mm having Aluminium conductor XLPE insulated, sheathed, galvanized, steel wire/steel tape armoured cable 1.1KV class
Labour charges for laying of 3.5Cx95 Sq.mm UG cable in existing trench
Digging of trench of Size 0.6mtr x 0.5mtr, laying of LT cable and refill the trench. In some places paver blocks, concrete & asphalt in cable route, whenever removed, re-fixed the paver blocks, re-concrete/ asphalt the road, Hard soil
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm around the cable
Supplying & laying of RCC semi cut pipe (C-CUT) in existing trench over the cable Size:150mm dia, 25 mm thick Supplying & laying of RCC semi cut pipe (C-CUT) in existing trench over the cable Size:150mm dia, 25 mm thick
M/s. Precision Electrical Works
J C Electricals
AJ ELECTRICALS
SRS ELECTRICALS
Shantha Electricals and Engineers Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .