Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | ₹10.3 L Quoted ₹12.2 L | L1 | Accepted-AOC lowest |
| 2 | L2₹12.8 L+₹58,045.46 (4.76%)Rejected-AOC | ₹12.8 L+₹58,045.46 (4.76%) | L2 | Rejected-AOC second lowest |
| 3 | L3₹12.9 L+₹70,945.79 (5.82%)Rejected-AOC | ₹12.9 L+₹70,945.79 (5.82%) | L3 | Rejected-AOC highest |
Tender Value
₹10.9 L
EMD Value
₹27,500
Closing Date
8 May 2026, 3:00 pmClosed
Assistant Engineer
110kV Substation, Valapad P O Valapad,680567
Installation of additional 5 MVA Transformer at 33 kV Substation Anthikad
2026_KSEB_848948_1
02/2026-27dated28.04.2026
Open Tender
Electrical Works
Percentage
180 days
33kV Substation Anthikad
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,900
₹27,500
6 Jun 2026
28 Apr 2026
11 May 2026
28 Apr 2026
8 May 2026
30 Apr 2026
28 Apr 2026 - 8 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Loading one 33kV CT / PT / 110kV NCT from the place of its storage to department lorry using required lifting device without causing any damage to equipment and its parts. | 4 | E | 949.38 | ₹3,797.51 |
| 2 | Unloading one 33KV CT/PT/110kV NCT from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers. | 4 | E | 712.03 | ₹2,848.12 |
| 3 | Conveying to the erection site and erecting carefully 1 No. 33KVCT/PT/110KV NCT &RVT/NCT(52/36kV) on the already erected structure after opening of crates erected structure after opening of crates at the place of storage leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools & tackles etc. | 4 | E | 1,865.54 | ₹7,462.16 |
| 4 | Loading one set 11kV Bus Isolator with its insulator stacks, supportingchannels,connecting pipes, isolating rods,mechanism box, structures and all itsaccessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation. | 1 | E | 210.98 | ₹210.98 |
| 5 | Unloading one set 11kV Bus Isolator with its insulator stacks, supporting channels, connecting pipes, isolatingrods, mechanism box, structures and all accessories safely without causing any damage using necessary lifting | 1 | E | 158.23 | ₹158.23 |
| 6 | Erection of one set 11KV Isolator / AB switch (station class) on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental
officers. | 1 | Set | 6,097.43 | ₹6,097.43 |
| 7 | Uncoiling, paving out, stringing and fixing of bus bar using ACSR Kundah / Wolf single conductor for one phase of 11/33KV bus of span up to 30M by cutting the conductor to sufficient length, crimping using compressor / bolting the two ends, washing, cleaning and drying the insulator discs, fixing the conductors to the yard structure with sufficient tension using string of insulators and hardware complete. at both ends, fixing of arcing horns including transportation of materials from the stockyard to the site under the supervision and direction of department staff at site. (All materials will be supplied departmentally at free of
cost). (cost index(e) : 1.3132 included in Rate) | 2 | E | 4,338.6 | ₹8,677.2 |
| 8 | Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point. | 18 | No | 158.91 | ₹2,860.38 |
| 9 | Providing droppers and connecting to lines / equipments or jumper between two buses with necessary suspension insulators for 33kV/66kV/110kV/220kV using ACSR Moose/ Kundah/ wolf Single conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. (For one phase) | 40 | E | 2,166.08 | ₹86,643.36 |
| 10 | Loading one 11kV LA from the place of its storage to department lorry, if required, after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers. | 3 | E | 56.99 | ₹170.98 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.04 MB
Tendernotice_2.pdf
PDF • 0.31 MB
BOQ_1434607.xls
BOQ • 0.33 MB
corrigendum.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .