KEL Kochi
SETTING UP OF MODERN RICE MILL PROJECT AT KALLEPULLY, PALAKKAD DISTRICT - HT AND LT ELECTRIFICATION WORK.
2021_KEL_420938_1
KRO/ BDC/879/2020
Open Tender
Electrical Works
Item Rate
210 days
KEL Kochi
As per NIT
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
9 Apr 2021
30 Mar 2021
9 Apr 2021
30 Mar 2021
7 Apr 2021
30 Mar 2021
30 Mar 2021 - 7 Apr 2021
Amount
PARTICULARS
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium class PVC conduit , with modular switch, modular plate, suitable GI box /Plastic surface box and earthing the point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Group : C Light point
Group : C Fan point.
Group : C Exhaust Fan point.
Wiring Batten Light Point OR PENDENT Type in the above system.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
3 x 1.5 Sq.mm
3x 2.5 Sq.mm
3 x 4 sq. mm
5 x 6 sq. mm
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box /PVC surface box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 5/6 & 15/16 amps modular socket outlet and 15/16amps modular switch connection etc as required..
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.3 8 way (4 + 24), Double door.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 63 A, 415 V “C” curve TP isolater complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc.as required.
Supplying and fixing 5 amps to 32 amps rating, 240 /415 volts, `C' Curve , miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required .
Single pole
Double pole
Triple pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. 2.2.1 100 A, 16 kA,TPMCCB
Supply installation testing & commissioning of 8 Ways Vertical DBs- Provision for TP MCCB (V-TEC) N2 Frame up to 125A in 16kA, 25kA as Incomer. IP : 43 Protection, Shrouded Neutral Bus Bar & Pan assembly with flexible connected link, Cement Spill Protector, Door Earthing. INDOASIAN or same spec havells ,legrand, abb, l&t..
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 63 A, 415 V “C” curve TP isolater complete with connections, testing and commissioning etc. as required.
LIGHT FITTING AND FANS. Supply, Installation, Testing & Commissioning of deco batten type1x20W LED Type Tube Light design channel light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc.(including lamp) as required (Make Philips,Crompton Greeves.)
Supply, installation, testing and commisioning of following sweep ceiling fan, including wiring the down rods of standard length (upto 30 cm t0 100cm) with 1.5 sq. mm FR PVC insulated, copper condutor, single core cable etc. as required. (a) 1200 mm sweep ceiling fan white shade with stepped type electronic fan regulator OR 400mm 3 Blade Wall fan(Usha (Striker)/,Crompton(High breeze)/ Havells (Velocity))
Supply, installation, testing and commissioning of following exhaust fan in the exisitng opening, including making the hole to suit the size of the above fan, making good damage, connection, testing, commisioning etc. as required. (a) 230 mm (Make:- Almonard - light duty)
HT Meter- Supply, Installation, Testing & Commissioning of 11kV HT Outdoor Metering Panel of following specification with all accessories and relevant approvals, test ceritificates etc as required from Electrical Inspectorate/State electricity board. 11 kV HT Outdoor Metering Panel of follwoing specifications , CT Ratio 10/5A, 15VA,CI:0.5 , Fixed Type PT of ratio : 11KV/110V, 100VA, CI:0.5 ,HT HRC Fuses ** Amps ,Seal Off Bushings, Shunt Trip Coil - 230 V AC, Space Heater with thermostat , 400 A Aluminium busbars and support insulators, TOD Energy meter ( L&T Make)
Fabrication of fully partitioned, floor or wall mounting, dust and vermin proof enclosure for Motor control panel (1) assembly as per form 4 of IS 8623 (with latest amendments) using 1.60/2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4.00 sq mm braided copper conductor, providing necessary cut-outs for mounting and providing suitable CTs, meters, relays, contactors,Isolator, Timer, indication lamps, multifunction meters, bus bar interconnection, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly. Supply and fixing the A' section neoprene beeding suitable for 1.60/2.00 mm sheet along the periphery of doors/other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue. Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc as required. Fabrication, supply & fixing main bus bar system and interconnections with suitable sizes of Aluminium strips/rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, aluminium sockets for round conductors etc as required. (Total outgoings-9 nos of Star delta motor sarter,and 365 A Isolator incomer).
Fabrication of fully partitioned, floor or wall mounting, dust and vermin proof enclosure for Motor control panel(2) assembly as per form 4 of IS 8623 (with latest amendments) using 1.60/2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4.00 sq mm braided copper conductor, providing necessary cut-outs for mounting and providing suitable CTs, meters, relays, contactors,Isolator, Timer, indication lamps, multifunction meters, bus bar interconnection, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly. Supply and fixing the A' section neoprene beeding suitable for 1.60/2.00 mm sheet along the periphery of doors/other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue. Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc as required. Fabrication, supply & fixing main bus bar system and interconnections with suitable sizes of Aluminium strips/rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, aluminium sockets for round conductors etc as required. (Total outgoings-10 nos D/O/L motor sarter and 125 A Isolator incomer)
Fabrication of fully partitioned, floor or wall mounting, dust and vermin proof enclosure for Motor control panel (3) assembly as per form 4 of IS 8623 (with latest amendments) using 1.60/2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4.00 sq mm braided copper conductor, providing necessary cut-outs for mounting and providing suitable CTs, meters, relays, contactors,Isolator, Timer, indication lamps, multifunction meters, bus bar interconnection, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly. Supply and fixing the A' section neoprene beeding suitable for 1.60/2.00 mm sheet along the periphery of doors/other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue. Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc as required. Fabrication, supply & fixing main bus bar system and interconnections with suitable sizes of Aluminium strips/rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, aluminium sockets for round conductors etc as required. (Total outgoings-7nos of D/O/L motor sarter, Srardelta starter 2nos of and 125 A Isolator incomer)
(1.17.13) Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.5 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
supply and installation of suitable Type extended &Directed rom( Mccb rotary handles)
(LMR) Suitable for 400 Amp
(LMR) Suitable for 200 Amp
(LMR) Suitable for 125 Amp
(LMR) Suitable for 100 Amp
( 1421)160A, TPN Switch Disconnector Fuse Unit
( LMR)63A, TPN Switch Disconnector Fuse Unit
( LMR) Supply and installation of 3pole power contractors (Mo40)type MO features common coil for 50&60Hz application ,Lo pik up va consumption standardized accessories for 9A-110A and 140A- 300A range suitablefor Lug as well as termination (L&T make)for20Hp,25Hp,30Hp motor confomto Is/Iec60947-4-1&Iec6047-4-1
(LMR) Supply and installation of Relays for 20 Hp,25 Hp, 30 Hp motor starts features Ambient temperatures compensatedup to 55 degrees Celsius, built in singele phaseing protection, manual and auto reset, mode ,Sealable in off condition (L&T make 17-25.5 RTO 1)
( LMR) Supply and installation of 3 pole power contractors (Mo25)type MO features common coil for 50&60Hz application ,Lo pik up va consumption standardized accessories for 9A-110A and 140A- 300A range suitablefor Lug as well as termination (L&T make)for15Hp,13Hp,10Hp motor confomto Is/Iec60947-4-1&Iec6047-4-1
( LMR) Supply and installation of 3 pole power contractors (Mo18)type MO features common coil for 50&60Hz application ,Lo pik up va consumption standardized accessories for 9A-110A and 140A- 300A range suitablefor Lug as well as termination (L&T make)for15Hp,13Hp,10Hp motor confomto Is/Iec60947-4-1&Iec6047-4-1
(LMR) Supply and installation of Relays for 10Hp, 13Hp motor starts features Ambient temperatures compensatedup to 55 degrees Celsius, built in singele phaseing protection, manual and auto reset, mode ,Sealable in off condition (L&T Make 12.5-+8.5RTO -1)
(LMR) Supply and installation of Relays for 15 Hp, motor starts features Ambient temperatures compensatedup to 55 degrees Celsius, built in singele phaseing protection, manual and auto reset, mode ,Sealable in off condition (L&T Make 17-25.5 RTO -1)
(LMR) Supply and installation of Timer for star delta motor starter (electronic type timer ST 100 make L&T)
(L.M.R) supply and installation On,off push switch with indicator and enclosures in all motor starter
(LMR)63A, TPN Switch Disconnector Fuse Unit (FN type suitable for BS fuse link, L&T make
(LMR)63A, TPN Switch Disconnector Fuse Unit (FN type suitable for BS fuse link, L&T make
(LMR)HRC fuse links bolted type 125A
(LMR)HRC fuse links bolted type 50A
(LMR)HRC fuse links bolted type 32A
(LMR)HRC fuse links bolted type 16A
(LMR)HRC fuse links bolted type 10 A
(LMR)HRC fuse links bolted type 250 A
(2.10.3)supply and installation following TP MCB 32A
Installation, Testing & Commissioning of 320 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms
Installation & Commissining of 500, 600 kva indoor type USS, 11KV
I. HT CABLE- Supply of 11kV, 3C 300sqmm (E) grade XLPE insulated, PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard.
D. LT CABLE- Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date.-
3.5 C x 400 sqmm
3.5 C x 300 sqmm
3.5 C x 185 sqmm
3.5 C x120 sqmm
3.5 C x 95 sqmm
3.5 C x 35sqmm
3.5 C x 25sqmm
3.5 C x 16sqmm
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor power cable conforming to IS amended upto date.-
3 x 2.5 sqmm
8 x 2.5 sqmm
A. H.T CABLE LAYING- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.-
Upto 120Sqmm
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.-
Upto 120Sqmm
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.-
Upto 120Sqmm
Above 120 sq. mm and upto 400 sq. mm
B. HV CABLE END TERMINATION- Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : - 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :- 300 sq. mm
C. LT CABLE LAYING & END TERMINATION. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.-
Up to 35 Sq.mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Up to 35 Sq.mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 C x 400 sqmm
3.5 C x 300sqmm
3.5 C x 185qmm
3.5 C x150 sqmm
3.5 C x120 sqmm
3.5 C x 95 sqmm
3.5 C x 70sqmm
3.5 C x 35sqmm
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3 x 2.5 sqmm
F. CABLE TRAYS & M.S./ G.I. ITEMS.- Cable Trays and cable supports fabricated out ofM.S.Angles (ISA) and M.S. flats with sufficient widthand Spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with 2coats of Zinc chromate primer and 2coats of enamel paint. Thedesign of the cable trays and details shall be got approved by the Electrical Consultant/ client.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.- 100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.-
100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required- 100 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.- 150 mm dia
300 mm dia
D. EARTHING- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with Copper earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
E. LIGHTNING PROTECTION- Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
F. SAFETY EQUIPMENTS - Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/ 1969.
Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429/ 1969.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Supply of 15" long rubber Hand gloves 15KV grade of approved make
Supply and fixing single line schematic diagrams of A1 size on suitable aluminium sheet including lamination etc as required complete on wall.
Fabrication,supply and installation of 6mm thick MS checkered plate with suitable size angle frame work, fixing, painting with 2 coat of primer & 2 coat of enamel paint for fire proof partition between floors in the electrical ducts and covering cable trench etc as required
Supply and installation of metal H.T. danger Cable route marker.
Supply and installation of L.T. Cable route marker.
Supply, Installation & wiring of emergency trip push button station
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Electrical Inspectorate approval. Preparation of drawings showing site plans, physical layouts line diagram of the equipment, switch boards, earthing arrangement etc, along with proposals, design details and calculations as required by the Kerala State Electrical Inspectorate for the technical approval of the installaton, arranging inspection,getting sanction for energisation etc complete.
Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
CUBIX INFRASTRUCTURES
K D George
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .