Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.5 L+₹1.3 L (5.42%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-Finance Not L1 | |
| 3 | L2₹25.9 L+₹2.7 L (11.6%)Rejected-Finance 2 SHANTI NAGAR SECTOR 3 HIRAN MARGI UDAIPUR 313002 | UDAIPUR | UDAIPUR | RAJASTHAN | 313002 | L2 | Rejected-Finance Not L1 |
Tender Value
₹23.8 L
EMD Value
₹47,565
Closing Date
18 Jun 2018, 4:00 pmClosed
AGM (E-E), AAI, Calicut International Airport
AGM (E-E), AAI, Calicut International Airport, Kondotty - 673647
Construction of New DVOR at Calicut International Airport _ Electrical Works
2018_AAI_11137_1
AAI/CL/ENGG(E)/10/NIT-02
Open Tender
Electrical Works
Works
60 days
AAI, Calicut International Airport
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,120
Yes
AAI, Calicut International Airport
₹47,565
Yes
2 Jul 2021
25 May 2018
22 Jun 2018
26 May 2018
18 Jun 2018
26 May 2018
26 May 2018 - 18 Jun 2018
Amount
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. 8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 2 + 4 way, Double door
Supplying and fixing 5 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole 63 A
Supplying and fixing four pole to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 20 Amps
Supplying and fixing Double pole 20 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole 6A - 5 Nos b) Single pole 10A - 5 Nos c) Single pole 32A - 5 Nos
Supplying and fixing 3 pole 20A amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a)Triple pole 20 A
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16 amps 415 volts "C" curve FP MCB complete with connections, testing and commissioning etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. a) Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supply and Installation of PVC Trunking of size 100mmx50mm including all accessoires like jointing sleeve, junction box, end cover,external/internal corner, coupler etc required for the complete installation on wall as required. (make :MK NCT1050 or equivalent).
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/Trunking as required. 3 x 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply and fixing of module mounting box suitable for fixing in cable trunking (Make: MK, model NSB/1T3I or equivalent) with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. all accessories for fixing the same complete as required as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply of 18W LED, 6000-6500K, (4 ft.) with LED lamp & batten for LED tube (single) made of extruded aluminium with heat sink provided for efficient heat dissipation & integrated electronic driver suitable for operation on 220V, 50 Hz AC supply or equivalent in AAI approved make complete as required.
Supply of Energy saving new generation 10W LED bulkhead luminaire with opal diffuser for operation on 220V, 50 Hz AC supply or equivalent in AAI approved make complete as required.
Supply of 250mm sweep high quality plastic Exhaust fan which is resistant to colour change having anti-static properties, with minimum speed of 1200 rpm, air delivery of minimum 850CMM, suitable for mounting on wall for operation on 220V, 50 Hz AC supply or equivalent in AAI approved make complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent / LED fitting of all types, complete with all accessories and tube/driver etc. directly on ceiling / wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of 1200mm sweep high quality Ceiling fan of 5 star rated, which is resistant to colour change having anti-static properties for operation on 220V, 50 Hz AC supply or equivalent in AAI approved make complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated , copper conductor, single core cable etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switchbox including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supply of surface mounting analouge time switches of 24 hrs. programmable with 4 terminals with IP 53 box and mounting accessories of make:- Legrand, Cat No:- 6499 14A or equivalent in approved makes of AAI, suitable for operation on 220V, 50 Hz AC supply and installation of the same on wall including connections etc complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of XLPE insulated PVC inner sheathed, armoured aluminium conductor underground power cable of 1.1 KV grade of following size conforming to IS:7098(Part-I) 1988, with upto date amendments etc., complete as required. a) 3.5 x 185 Sq.mm
Supply of XLPE insulated PVC inner sheathed, armoured aluminium conductor underground power cable of 1.1 KV grade of following size conforming to IS:7098(Part-I) 1988, with upto date amendments etc., complete as required. a) 3.5 x 120 Sq.mm
Supplying and laying of following size HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Retrieving of LT power cables/pipes not exceeding 80 mm dia to a depth of 1.2 m meter by manual excavation without any damages to cables/pipes in all kinds of soils, refilling the trench with excavated soil etc complete as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 x 185 Sq.mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 x 120 Sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 X 25 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5X 240 sq. mm (62mm)
Excavation of trenches by mechanical means in all kinds of soil for cables/ pipes, width not exceeding 300 mm upto a depth of 0.8m including refilling the trench and disposal of surplus soil etc as required.
Excavation of trenches in hard rock for cables/ pipes upto 80mm dia up to a depth of 0.8 meter including refilling the trench and disposal of surplus soil etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. a) Above 95 sq. mm and upto 185 sq. mm
Supply and laying 80mm 'B' class G.I. pipe in soil including cutting of bituminous road/shoulder up to an average depth of 150mm and required width, excavation of soil up to 750mm (approx.) from pavement level, refilling the trench with excavated soil in bottom and filling pavement cutting with cement concrete of 1:2:4 (1cement:2sand: 4graded stone 20mm aggregate), finishing the surface etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supply, Installation, Testing and Commissioning of Block MOV based Surge Divertor (BMOVSD)100 KA, 3 Phase, 4 wire with neutral protection in pre-wired IP55 grade powder coated metal enclosure complete with sensing circuit, potential free contacts, necessary indications and alarm for Essential Panel connect in parallel.(Make: Tercel, Model: ISOSURGE or equivalent in approved makes of AAI.)
Fire Alarm System : Supply, Installation, Testing and Commissioning of Conventional type 2 wire photoelectric smoke detector alongwith plug in type detector base having class change capability and other accessories complete as required. (system sensor Model No.SSF2351E/System sensor model No.SSFB401 or similar)
Supply, Installation, Testing and Commissioning of conventional type 2 zone fire alarm panel suitable for operation on 230V, +/- 5%, 1Phase Ac supply with dust and vermin proof enclosure made of sheets steel cubicle , wall mounting type complete having battery back up with suitable sealed maintenance free Lead Acid type battery providing back up power of at least 20 Minutes including battery charger circuits etc as per specification. The panel shall have LCD /LED indicators, control switches, provision to integrate with Auto dialing facility ( Morley Model No. M0F002492222 HRZ-2e or similar as per list of approved make).
Supply, Installation, Testing and Commissioning of Auto Dialer with LCD display, single/Dual message stage, in built key pad for storing telephone number, Automatic mode change over from programming mode to execution mode, false dialing prevention etc as per specification attached (SECURICO Model No. SE1SECSD 2 or similar as per list of approved Makes.
Supplying and drawing of 2 core 1.5Sq mm FRLS cable in fire retardant PVC pipes fixed to surface of wall/ceiling/false ceiling using clamps of suitable size including supply & fixing of PVC pipes etc complete as required.
Airconditioning System : SITC of 3 Ton Split type ductable Airconditioner of with consisting of single type room unit (evaporator unit) with wired/cordless remote control and one number outdoor condensing unit comprising of energy efficient including upto date ammendments, suitable for operation on 415V, 50Hz. AC supply with non CFC refrigerant/ R-410/R 407C and capable of performing (a) cooling (b) moisture removal (c) air -Circulating (d) filtering including fixing the outdoor condenser unit on a raised with suitable pedestals duly painted/Metal Stand as per site requirement (Pedestals/Metal Stand to be provided by you) and fixing of Evaporator unit including providing and making inter connections between evaporator unit and condensing unit up to a length of 5 mtrs. comprising of the following including first charge of refrigerant etc., compleate as required (COPPER). The quote shall include cost of refrigerant piping, insulation, drain piping etc.
Supply and fixing of the following complete as required and as per special conditions of the contract a) 1" Drain pipe for heavy duty PVC pipe or as per OEM specification for the above item.
b) 1/4" dia Insulated copper pipe for liquid line or as per OEM specification for the above item.
c) 5/8" Insulated copper pipe for suction or as per OEM specification for the above item.
d) (2+1E) Core x 4 sq.mm FR insulated, PVC sheathed unarmored multi strand copper cable or as per OEM specification for the above item.
Supply and fixing of extruded aluminium grilles for return and supply air as required including making, finishing and making good any wall opening as required.
Supply and fixing of fusible link fire dampers made of GI 16G as per list approved makes complete as required.
Supply and installation including connections of Twin AC Controller (Make:- Miniliec, Cat No:- Protocom 4) for to control two AC installations upto 1.5 Ton, having built in over voltage and under Voltage protections suitable for operation on 220V, 50 Hz AC supply or equivalent in AAI approved make as per instruction of engineer in charge complete as required.
Supply, installation testing and commissioning of Isowall boxing for existing indoor unit suitable for 3 TR ductable split unit as required.
Manish Electricals
MPC ELECTRICALS AND ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .