Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.5 LAccepted-AOC B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹17 L+₹9.4 L (125.2%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical K701 MARVEL ZEPHYR KHARADI PUNE MAHARASHTRA 411014 UDYAM MH 26 0652381 27AADCE9912F1ZM B R | PUNE | MAHARASHTRA | 411014 | - | Rejected-Technical Not approved due to not enlisted in requisite category | |
| 4 | Rejected-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | - | Rejected-Technical Not approved due to not enlisted in requisite category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not approved due to not enlisted in requisite category |
Tender Value
₹7.6 L
Closing Date
29 Apr 2025, 6:00 pmClosed
SHRI AK MISHRA, IDSE, CWE
HQ CWE MAMUN PIN 145001
JOB ORDER FOR CONSULTANCY SERVICES FOR PROVN OF ROOF TOP SOLAR PLANT OF 500 KW CAPACITY AT MAMUN MIL STATION UNDER GE NORTH MAMUN AND 350 KW CAPACITY AT SAMBA MIL STATION UNDER GE SAMBA J and K
2025_MES_702581_2
3016/JO/2025-26/01/E3
Open Tender
Miscellaneous Works
Item Rate
60 days
mamun and samba
as per tender documents
6 documents required · 6 mandatory
₹0
Exempted
14 May 2025
16 Apr 2025
1 May 2025
16 Apr 2025
29 Apr 2025
17 Apr 2025
Amount
(a) Detailed shadow analysis and technical feasibility report for layout of PV modules on roof top as per longitude/latitude in r/o both Mil stations separately (b) SPV module must have by pass diode. Indian origin and preferably with efficiency more than 20.90% under STC (Standard Test Conditions) and confirming to latest IEC for construction, testing and safety qualifications. (c) SPV grid inverter consist of MPPT suitable for low tension. Invertor conversion AC/DC efficiency must be more than 90%. It must have internal protection against any sustainable fault in feeder and against the lightning on feeder and shall have inbuilt isolating transformer. (d) The MS hot dipped galvanized (microns) mounting steel structure shall be withstand wind load at Mamun Mil Stn. The fasteners shall be stainless steel and fixed duly protected any leakage from roof and shall allow easy replacement of any module. (e) The bi-directional meter and check meters for net metering is to be installed as per guidelines of PSPCL in r/o Mamun Mil stn. (f) Any equipment of SPV which is not specifically mentioned above but required technically for smooth functional requirement of plant is deemed to be included in quoted rates. (g) Lauout/drawings for PV Modules and connected items to be submitted. (h) Design of SPV plant to be vetted by the agency approved by MNRE.
(a) Detailed shadow analysis and technical feasibility report for layout of PV modules on roof top as per longitude/latitude in r/o both Mil stations separately (b) SPV module must have by pass diode. Indian origin and preferably with efficiency more than 20.90% under STC (Standard Test Conditions) and confirming to latest IEC for construction, testing and safety qualifications. (c) SPV grid inverter consist of MPPT suitable for low tension. Invertor conversion AC/DC efficiency must be more than 90%. It must have internal protection against any sustainable fault in feeder and against the lightning on feeder and shall have inbuilt isolating transformer. (d) The MS hot dipped galvanized (microns) mounting steel structure shall be withstand wind load at Mamun Mil Stn. The fasteners shall be stainless steel and fixed duly protected any leakage from roof and shall allow easy replacement of any module. (e) The bi-directional meter and check meters for net metering is to be installed as per guidelines of JPDCL in r/o Samba Mil stn. (f) Any equipment of SPV which is not specifically mentioned above but required technically for smooth functional requirement of plant is deemed to be included in quoted rates. (g) Lauout/drawings for PV Modules and connected items to be submitted. (h) Design of SPV plant to be vetted by the agency approved by MNRE.
ELECTRICITYNOPROBLEM (BID ID -3286385)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .