Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.0 LAdmitted-Finance | -9.96% | ₹8.0 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | - | Rejected-Technical not qaulified as short fall not submitted |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical not qaulified as short fall not submitted |
Tender Value
₹8.9 L
EMD Value
₹17,780
Closing Date
17 Aug 2026, 5:00 pmClosed
SE (TNC), RVPN, SAKATPURA, KOTA
SE (TNC), RVPN, SAKATPURA, KOTA
Augmentation Work of 132/33 kV, 20/25 MVA) Power transformer and P and F of yard light at 132KV GSS Mandana
2026_RRVPN_579636_1
RVPN/SE/TNC/KOTA/2026/NIT-21
Open Tender
Electrical Works
Percentage
90 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
1180 AO TNC RVPN KOTA
₹17,780
Yes
SE (TNC), RVPN, SAKATPURA, KOTA
4 Sept 2026
31 Jul 2026
18 Aug 2026
31 Jul 2026
17 Aug 2026
31 Jul 2026
4 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1EARTH MESH WORK Laying of earth mesh with 25mm / 28mm dia. M.S. Rod at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M. S. Rods from site store to locations, welding of M. S. Rod to M. S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil revalent at 0.80 metre below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN). (a) In case electricity is made available by RVPN without Charges (i) Any soil,soft rock other than hard rock | |||||
| 2Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S Flat at a depth of 0.80 meters from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S Flat from site store to locations, preparation of risers bending as per requirement ( after heating if necessary), fixing on and welding / bolting to equipment/ structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S Rods as per drawing, including welding of extra length of M.S Flat of required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations ( M.S Rod of above sizes & M.S Flat as required shall be made available by RVPN) (a) In case electricity is made available by RVPN without charges (i) Any Soil, Soft Rock other then Hard Rock | |||||
| 3Placing of earth electrode of 25 / 28mm dia. M. S. Rod of length 7.50 meters (approx.) to a depth of 8.00 meters from the top level of foundations, including drilling of 200 mm dia. earth pit having a throughout bore of 200 mm dia to a depth of 8.00 metres from the top level of the foundations, in all types of rocks by DTH system and overburden, including back filling of pit with Bentonite slurry (with cost of Bentonite slurry), including its preparation, transportation of M. S. Rod and Bentonite from site store to location, cutting of M. S. Rod to desired length, welding of earth electrode to earth mesh of M. S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints ( (M.S Rod of above size & M.s Flat as required shall be made available by RVPN ) (i) In case electricity is made available by RVPN without charges. | |||||
| 4ERECTION OF SUB STATION STEEL STRUCTURES columns, beams lighting mast and equipment structures ( excluding Circuit Breakers and Capacitors Banks ) of all types including transportation of structure members nuts & bolts, washers etc from site store to location | |||||
| 5BUS - BAR WORK STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basis). ii) any conductor | |||||
| 6JUMPERS OF ACSR conductor (3 nos Y type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulatros and hardware from site stiores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections,fixing of spacers & spacer T clamps as required tightening of clamps / connectors, dressing etc for three phases per jumper basis i) Any Conductor | |||||
| 7STRINGING OF Earth wire ( suze 7/3.15mm or 7/4.00mm ), including transportation of eathwire, tension hardwares, etc from site store to locations lasying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available ( comppression machine shall be provided by RVPN on rent free basis), making up at one end stringing of earthware between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire. | |||||
| 8ERECTION OF SUB-STATION EQUIPMENTS Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer 1 Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc., complete in all respects. | |||||
| 8.01 | (ii) 132KV CT | - | Nos | - | - |
| 8.02 | iii) 33 KV CT | - | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_1030045.xls
BOQ • 0.29 MB
TECHNICAL-DOCUMENT-01_compressed.pdf
Tender Documents • 18.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .