| 1 | L1₹14.4 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.4 L+₹90,253 (6.25%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.5 L+₹1.0 L (7.12%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹15.7 L+₹1.2 L (8.36%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹16.0 L+₹1.5 L (10.6%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance L5 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
3 Aug 2020, 6:00 pmClosed
Lt Col Amit Bhat
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
PROVISION OF CERTAIN WORK SERVICES AT EE HAIL OF 767 SU AND WATER PROOFING OF ORP 06 AND ORP 12 AT AFS JAMNAGAR
2020_MES_358558_1
8740/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹38,000
Yes
17 Sept 2020
6 Jul 2020
4 Aug 2020
6 Jul 2020
3 Aug 2020
20 Jul 2020
Amount
Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete of any description and in any position complete all as specified and directed by Engr-in-Charge.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge.
Surface excavation averaging 30 cm deep in soft/loose soil from roof of building/structure and getting out complete all as specified and directed by Engr-in-Charge.
M&L for Moorum/red bajri filling over roof of building / structure up to 12 metre height, laid in layers n exc. 15 cm thick, spread, levelled and rammed, watering including turning on top surface of moorum, complete all as specified and directed by Engr-in-Charge.
Taking down of existing roof treatment of hessien base felt/tar felt/PCC/plaster/tiles (any type) complete including disposal of debris out of defence land complete all as specified and directed by Engr-in-Charge.
Cutting chases in brick work for inserting water proofing membrane in to the parapet walls/column & making good to facing where required and pointing in CM 1:3 to the groves, cutting n exc. 10 cm girth.
Supply only Liquid water proofing compound. Make:- Pidilite / Fosroc / IWL / Cisco
M & L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed 1:4 CM base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete block masonry with solid block 1:5:8 mix ( using 20mm graded aggregate ), exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for rendering cement plaster 10mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparing new surfaces, plastered or unplastered for two coats of oil bound distempering finished with roller over a coat of chalk whiting/wall putty on newly plastered surfaces complete all as specified and directed by Engr-in-Charge.
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165
M&L for preparation of new steel surfaces over 10cm width and girth and applying two coat of synthetic enamel paint over a coat of red oxide primer.
Removing excavated material exc 500m and total distance 1500m and depositing where directed above the starting point etc complete all as specified and directed by Engr-in-Charge.
Taking down chowkat or frames with shutter (without taking of shutter from the frame) exc 1.5 sqm but n. exc. 4.0 Sqm each
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side &as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing
S&F solid PVC door frame of size 50mmx47mm made out of 5mm palin colour PVC sheet reinforced with M.S Square tube supplying & fixing in opening as per specification & drawing
M&L for stainless steel butt hinges medium grade 100mm long.
M&L for Aluminium tower bolt 150 mm long complete all as specified and directed by Engr-in-Charge.
M&L for Aluminium handle 150 mm complete all as complete all as specified and directed by Engr-in-Charge.
S&F 35 mm thick second class hardwood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass / gauge, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkhats complete all as specified and directed by Engr-in-Charge.
S&F second class hardwood plain, solid, straight chowkhats and frames, wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and directed by Engr-in-Charge.
S&F 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated surface (Plastered or unplastered) by brooming down and applying one coat of white was on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spouts and cleaning with water on wall complete all as specified and directed by Engr-in-charge.
M & L for preparation of plastered surfaces of walls including pilasters / cornices etc and applying two coats of Acrylic emulsion (exterior weather coat) plastered or unplastered paint by brooming down of any tint as approved over one coat of primer applied as per manufacturer,s instruction complete all as specified and directed by Engr-in-Charge. Make:- Asian (Apex), Nerolac (Excel), Berger (walmasta), ICI (weater Shild)
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key scrubbing down with water etc
M&L for rendering 15mm thick in CM 1:4 using water proofing compound @ 3% by wt of cement on fair faces of brick work or concrete surfaces and finish the surface even and smooth without using extra cement all as specified and as directed by Engineer-In-Charge. (WPC shall be measured and paid separately)
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed by Engr-in-Charge.
M&L for screed bed 10 mm thick on concrete surface in cement mortar (1:4) finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and directed by Engr-in-Charge. Note:- WPC will be measured & Paid separately
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and directed by Engr-in-Charge.
Excavating over areas, n. exc 1.5 m deep and getting out in soft / loose soil
Removing excavated material Exc 250m and n exc 500 m and depositing where directed at a level n exc 1.5 m above starting point in Soil.
M&L for Moorum/red bajari filling in floors or pavings, laid in layers n exc 15 CM thick, spread levelled and rammed including watering as approved by Engr in Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for 100 mm thick Cement concrete type B-2, 1:2:4 (40mm graded aggregate)as in floors/ path finished fair and even.
M&L for sand cushioning 25 mm thick , spreading including levelling complete all as specified and directed by Engr-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape confirming to IS-15658-2006 of 60mm thickness, M-35 grade complete all as specified and directed by Engr-in-Charge.
Filleting in any position and any shape in cement mortar 1:4 including all mitres, stops, etc. Exc. 25 but n.exc 50 sq.cm.
S & F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete with all fitting arrangement on porcelain insulators & screw all as specified and directed by engineer-in-Charge.
S & F Aluminium strip of size 25 x 3.15 mm fixed on wall/ roof with saddles and fixing on porcelain insulator & screw etc for earth continuity conductors as continuous earth strips from copper rod to test point terminal all as specified and directed by engineer-in-Charge.
M&L for test point terminal block made of gunmetal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw mounting on porcelain insulator housing including sintex junction box of size 150 mm x 150 mm x 100 mm all as specified and directed by engineer-in-charge.
Material and labour for renewal of earthing complete with Galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI strip 32x6mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection.....
.......including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
S & F GI strip of size 32 x 6 mm fixed on wall/ roof with saddles and fixing on porcelain insulator & screw etc for earth continuity conductors as continues earth strips from earthing to test point terminal complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC conduit of dia 20 mm dia ISI marked with complete fitting such as elbow, tee , junction box, with fixing clamps and screw complete all as specified and directed by Engr-in-Charge. Note: Rate shall be quoted for fixing of conduit in any position including inside cable duct all as per site requirement.
Supply and fix/draw weather proof PVC insulated and sheathed multistranded copper conductor cable of size 4.0 Sqmm 4 core , 1100 volt grade. complete all as specified and directed by Engr-in-Charge.
S&F bell push, flush type, 5 amp
S&F bell, AC, 230 volts, single pole
SHELANI CONSTRUCTION
Prime Decor
Magnus Enterprise
JAMNAGAR ELECTRIC AND MACHINERY CO
EVEREST BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .