Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.3 L+₹1.7 L (18.3%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹12.7 L+₹3.1 L (32.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹14.0 L+₹4.4 L (46.3%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
19 Oct 2020, 6:00 pmClosed
Lt Col Sidhartha Singhal
GE (P) DAPPAR
Repair / Overhauling/periodical services to DG sets capacity 31.50 KVA to 250 KVA at Mil Stn Dappar under GE(P) Dappar
2020_MES_379525_1
GE (P) DPR-20/2020-21
Open Tender
Miscellaneous Services
Supply
270 days
GE (P) DAPPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) DAPPAR
₹33,000
Yes
21 Dec 2020
21 Sept 2020
21 Oct 2020
21 Sept 2020
19 Oct 2020
3 Oct 2020
21 Sept 2020 - 3 Oct 2020
Amount
M&L for repair of DG Set 200 KVA, Make : Kirloskar, Ser No 070031, F33M107CI4071 by replacement of following spares :-
Supply & Fix rubber Hoses (tgl 13880 4) of 200 KVA DG Set all as specified and directed. Make: Cat No F6.013.13.0.00Kiloskar or equivalent in Elofic/Bosch
Supply & Fix rubber Hoses FOR MAIN AIR of 200 KVA DG Set all as specified and directed. Make: Cat No F6. 680.06.0.00 , Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostat of WA of 200 KVA DG Set all as specified and directed. Make: Cat No F6.255.06.0.00, Kiloskar or equivalent in Elofic/Bosch
S&F Hose (for 200 KVA young RA) of 200 KVA DG Set all as specified and directed Cat No F6.150.03.0.000
M&L for control panel repair of 200 KVA DG Set all as specified and directed. Make Ser .020
M&L for engine control unit (EMS9) of 200 KVA DG set all as specified and directed, Cat No _ 2H.865.51.0.00
M&L for repair of relay board UL Make 4 CHA. Cat No F6.865.05.0.00 of 200 KVA DG Set all as specified and directed.
Repair/Replacement of SS Right hand Hinge for Cannopy. Cat No 3H.408.91.0.00 Make Kirloskar
M&L for repair of engine wiring assembly SU all as specified and directed. Cat No F6.959.10.0.00
Replacement of LFL Sensor (Low Fuel Lever) Cat No 6H.192.14.0.00
Replacement of KG 934 Controller with 4-2 for kirloskar 200 KVA DG all as specified and directed. Cat No 02.026.04.0.00
Material and labour repair to self starter 24Volt of 200 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original stae after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge. Complete all as specified and as directed by Engineer-in-Charge.
Supply only lubricant oil filter NO- F6.436.01.0.00. with its gasket. Make: Kiloskar or equivalent in Elofic/Bosch
Supply only fuel oil filter NO48.999.20.0.00Wih its gasket. Make: Kiloskar or equivalent in Elofic/Bosch.
Supply only Air filter inner & outer NO-F6729.03.00,F6729.05.0.00. with its gasket Kirloskar or equivalent in Elofic/Bosch.
Supply and fix joint for exhaust manifold Cat No. F6.026.03.0.00 all as specified and directed.
Repair/replacement of AVR model TAVR-3A-S/F KG Cat No. F6.0814.11.0.00 ll as specified and directed.
Material and labour for anti vibration mounts Cat No. F6.126.02.0.00 ll as specified and directed.
Repair to 24 volts charging alternator from engine of DG set capacity 200 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
M&L for repair of DG Set 82.5 KVA, Make : Kirloskar, Model No 4H-3555.1320.814 by replacement of following spares :-
Supply & Fix rubber Hoses compressor OU of 82.5 KVA DG Set all as specified and directed. Make: Cat No 4H.168..03.0.00 Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostat BYPASS HOSE OF 82.5 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00 , Kiloskar or equivalent in Elofic/Bosch
Supply and fix hose for air cleaner Cat No. 4H.227.12.0.00 all as specified and directed
M&L for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Repair/Replacement of kirloskar green AVR Cat No. 2H.811.32.0.00 all as specified and directed.
Supply and fix SS joint for exhaust MA Cat No. P2.106.01.0.00 all as specified and directed.
M&L for control panel repair Cat No Ser.020 all as specified and directed
Material and labour repair to self starter 12Volt of 82.5 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original stae after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge. Cat No SLF.001.00 Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix S Left Hand Hinge for CA Cat No- 3H.408.90.0.00. Make Kirloskar
M&L for KG934 controller with 4-2 Cat No 02.026.04.0.00 all as specified and directed.
Repair to 12 volts charging alternator from engine of DG set capacity 82.5 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
M&L for repair of DG Set 75 KVA, Make : Kirloskar, Model No 4R1040TA, by replacement of following spares :-
Replacement burnt out of stop solenoid with ISSC, Cat No 4H.150.01.0.00 all as specified and directed.
Supply & Fix rubber Hoses compressor OU of 75 KVA DG Set all as specified and directed. Make: Cat No 4H.168..03.0.00 Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostate BYPASS HOSE OF 75 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00 , Kiloskar or equivalent in Elofic/Bosch
Supply and fix hose air cleaner Cat No. 4H.227.12.0.00 all as specified and directed
M&L for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Repair/Replacement of kirloskar green AVR Cat No. 2H.811.32.0.00 all as specified and directed.
Material and labour repair to self starter 12Volt of 75 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original stae after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge. Cat No SLF.001.00 Complete all as specified and as directed by Engineer-in-Charge.
M&L for KG934 controller with 4-2 Cat No 02.026.04.0.00 all as specified and directed.
M&L for control panel repair of 75 KVA DG Set all as specified and directed. CAT No Ser.020
Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Repair to 12 volts charging alternator from engine of DG set capacity 75 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
Replacement of LFL Sensor (Low Fuel Lever) Cat No 6H.192.14.0.00 all as specified and directed
M&L for repair of DG Set 50 KVA, Make : Kirloskar, Model No 5H-3845/1420122 & 4H-3555.1320814 by replacement of following spares :-
Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostate BYPASS HOSE OF 50 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00 , Kiloskar or equivalent in Elofic/Bosch
Supply and fix L.O Supply hose (FIP) M10 Cat No. 4H.006.01.0.00 all as specified and directed
Supply and fix hose (pipe to water pump) Cat No. 4H.073.02.0.00 all as specified and directed.
M&L for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Repair/Replacement of kirloskar green AVR Cat No. 2H.811.32.0.00 all as specified and directed.
Replacement of KG 934 Controller with 4-2 for kirloskar 200 KVA DG all as specified and directed. Cat No 02.026.04.0.00
Supply and fix SS joint for exhaust MA Cat No. P2.106.01.0.00 all as specified and directed.
Repair of control panel repair Cat No Ser.020 all as specified and directed
Replacement of LFL Sensor (Low Fuel Lever) Cat No 6H.192.14.0.00
Repair to 12 volts charging alternator from engine of DG set capacity 75 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
M&L for repair of DG Set 50 KVA, Make : Ashok Leyland Ser No WFHM 395874, WFHM 395873 & WFHM 396079 by replacement of following spares :-
Supply & Fix lubricant oil filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix fuel filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter safety HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter primary HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply and fix hose HSN Code 40091100 all as specified and directed.
Supply and fix Diesel Pipe HSN Code 40091100 all as specified and directed.
Replacement of stopper HSN Code 40091100 all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 50 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN COde 998729 to the entire satisfaction of Engr-in-charge
M&L for repair of DG Set 31.25 KVA, Make : Ashok Leyland Ser No WFHM 393453 & WFHM 393452 by replacement of following spares :-
Supply & Fix lubricant oil filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix fuel filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter safety HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter primary HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply and fix hose HSN Code 40091100 all as specified and directed.
Supply and fix Diesel Pipe HSN Code 40091100 all as specified and directed.
Replacement of stopper HSN Code 40091100 all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 31.25 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge
M&L for repair of DG Set (1010KVA silent (radiator type) Cummins KTA38G5 & Alternator - 1010KVA Stamford, DG 1 Engine No 25418954, Alternator No N16J403681, DG 2 Engine No 25421283, Alternator No N16I362553, DG 3 Engine No 2518952, Alternator No N16I362628 by replacement of following spares -
M&L for 'B' Check Kit KV HE, KIT3238516, Cat No 84212300 all as specified and directed by Enge-in-Charge
M&L Kit Air Cleaner Elements, KIT3238665 (K, QSK,V Series) all as specified and directed by Enge-in-Charge
M&L for Inhibitor Corrosion 205 Ltrs, Cat NO 3816981, HSN Code - 38200000 all as specified and directed by Enge-in-Charge
M&L for Inhibitor Corrosion 10 Ltrs, Cat NO 4926654, HSN Code - 38119000 all as specified and directed by Enge-in-Charge
M&L for Radiwash 5 Liters Cat No AX1013508, all as specified and directed by Enge-in-Charge
M&L for Valvorine Premium Blue 7800 Plus 1/55 Ltrs Cat No 506655 HAN No 27101980 all as specified and directed by Enge-in-Charge
M&L for Oil Extract BAG Cat No JKM OEM all as specified and directed by Enge-in-Charge
Repair to digital panel of DG set Panel all as specified and directed by Engr-in-charge
M&L for repair of DG Set 30 KVA, Mahindra, DG 1 Engine No N3A17AT24038, DG 2 Engine No N3F173A17AT24030, 8 by replacement of following spares
Supply and fix service kit element of fuel filter, HSN Code - 84212900 all as specified and directed
Supply & fix only engine oil filter HSN Code all as specified and directed
Supply and fix safety Air element4575GM, HSN Code 84219900 wih its gasket. Make : Mahindra or equivalent in Elofic/Bosch
Supply and fix primary element 75 HP, HSN Code 84219900 wih its gasket. Make Mahindra or equivalent in Elofic/Bosch
Supply and fix belt fan HSN Code 40101110 all as specified and directed
Supply and fix belt Gen/Alt Cogged (Hilton) HSN Code 40101110 all as specified and directed
Supply and fix fuel supply pipe, HSN Code 40091100 all as specified and directed.
Supply and fix fuel return Pipe HSN Code 40091100 all as specified and directed.
Supply and fix radiator hose inlet HSN Code 87089900 all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 30 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge
Supply and fix 4DI engine electrical HSN Code 85365090 all as specified and directed
Supply, Installation and testing in replacement Backlit LCD display type LT CT Operated Trivector Meter including Meter box/cover of make as that of meter's OEM with following specifications : Meter Type - 3 Phase, 4-Wire LTCT Operated Trivector Meter, Applicable Standard: Latest IS-14697, IS-15959, Accuracy Class: 0.5, Voltage and Current Rating: (i) Rated Voltage 415 ± 20% (Phase-Phase), (ii) Rated Current, Ibasic : 5A, Imax : 10A, Overload Capacity: 200% of Ibasic, Frequency : 50Hz ± 5%, Power factor Range: 0Lag-Unity-0Lead, Display: 7 Digit 7 Segment LCD Display, Min Power Consumption (i) Potential Circuit :1.5 Watts/Phase and 8VA/Phase, Current Circuit: 1VA/Phase, Type of Energy Registration: Electronic, Modes of Operation: Auto Mode, Battery Mode : Inbuilt Primary Battery activated by push Button. Communcation Port: (i) Galvanicaly Isolated Optical Communication port for Data Transfer, (ii) RS232 Port for Remote Communication, Load Survey: As per IS 15959 i.e. 45 days with integration period configuration - 15 Minutes - 30 Minutes, EMI/EMC Compliance as per IS: 14697, Self Diagnostic Feature: CT Ratio Non Programmable. The Meter shall have indication for followings:- 1. Time and date on meter display, 2. All Display segment as per the requirement under IS14697, 3. Non Volaltile Memory status in Meter Reading all as per HPL Make Part No: TLPB2921131000OC00 or equivalent in L&T/Schenider. NOTE - The quoted rate is deemed to be inclusive of suitable size FRP Meter enclosure all as per Meter's OEM.
Supply, Installation and testing in replacement Backlit LCD display type ABT based HT CT Operated Trivector Meter including Meter box/cover of make as that of meter's OEM with following specifications : Meter Type - 3 Phase, IP 51 class, 4-Wire HTCT Operated Trivector Meter, Applicable Standard: Latest IS-14697, IS-15959, Accuracy Class: 0.2, Voltage and Current Rating: (i) Rated Voltage 3x(11kV/√ 3/110V/√ 3) Ph-N (3P, 4W), (ii) Rated Current, Ibasic : 5A, Imax : 200% of Ibasic, Frequency : 50Hz ± 5%, Power factor Range: 0Lag-Unity-0Lead, Display: 7 Digit 7 Segment LCD Display, Min Power Consumption (i) Potential Circuit :1.5 Watts/Phase and 8VA/Phase, Current Circuit: 1VA/Phase, Type of Energy Registration: Electronic, Modes of Operation: Auto Mode, Battery Mode : Inbuilt Primary Battery activated by push Button. Communcation Port: (i) Galvanicaly Isolated Optical Communication port for Data Transfer, (ii) RS232 Port for Remote Communication, Load Survey: As per IS 15959 i.e. 45 days with integration period configuration - 15 Minutes - 30 Minutes, EMI/EMC Compliance as per IS: 14697, Self Diagnostic Feature: CT Ratio Non Programmable. The Meter shall have indication for followings:- (a). AUTO MODE: i) LCD Test, ii) Rising Apparent Demand with elapsed time, iii) Real Time & Date (DD/MM/YYYY), iv) Cumulative Power off Hours, v) Cumulative Total Active Energy (with high resolution), vi) Cumulative Total Reactive Energy Lag (with high resolution), vii) Cumulative Total Reactive Energy Lead (with high resolution), viii) Cumulative Apparent Energy (with high resolution) – Lag Only, viii) Apparent Max. Demand (with high resolution) – Lag Only, ix) TOD Wise Total Active Energies, x) TOD Wise Apparent Energies, xi) TOD Wise Apparent Max. Demand (MD), xii) Cumulative Apparent Maximum Demand, xiii) Cumulative Billing Count, xiv) Cumulative Tamper Count, xv) Phase Sequence, xvi) Connection Check, xvii) Self Diagnosis L&T/Schenider. (b) PUSH BUTTON MODE: i) LCD Test ii) Rising Apparent Demand with elapsed time, iii) Real Time & Date (DD/MM/YYYY), iv) Cumulative Power off Hours, v) Cumulative Total Active Energy (with high resolution), vi) Cumulative Total Reactive Energy Lag (with high resolution), vii) Cumulative Total Reactive Energy Lead (with high resolution), viii) Cumulative Apparent Energy (with high resolution) – Lag Only, ix) Apparent Max. Demand (with high resolution) – Lag Only, x) TOD Wise Total Active Energies, xi) TOD Wise Apparent Energies, xii) TOD Wise Apparent Max. Demand (MD), xiii) Cumulative Apparent Maximum Demand, xiv) Cumulative Billing Count, xv) Cumulative Tamper Count, xvi) Cumulative Programming Count, xvii) Last Billing Date & Time, xviii) Inst. Secondary Voltages – Phase Wise (Ph-N for 3-Ph, 4-Wire), xix) Inst. Secondary Currents – Phase Wise & Neutral, xx) Signed Inst. Power Factor – Phase Wise, xxi) Three Phase Power Factor, xxii) Signed Inst. Active Power, xxiii) Inst. Apparent Power, xxiv) Inst. Frequency, xxv) Present Tamper Status (PT/CT/Other), xxvi) First Occurrence with Date & Time, xxvii) Last Occurrence with Date & Time, xxviii) Last Restoration with Date & Time, xxix) Phase Sequence, xxx) Connection Check, xxxi) Self Diagnosis. The meter should be capable of recording the Apparent/Active MD with integration period of 15 minutes. MAKE - HPL/L&T, Schenider
S&F LTCT’S with Accuracy Class 0.5, Tape Wound , Each set of Three all as specified and directed.
Taking down radiator complete from engine of DG setcapacity 30/31.75/50/75/82.5/200 /250KVA/1010KVA at site and carrying out repairs/ cleaning and re fixing in original state after dully repaired in a perfect working condition to the entire satisfaction of Engineer-in-Charge and repair shall be comprissing of the following:- (a) Removing dust from fins interior& exterior portion clean to parts by air cleaner and wash out by using maic solution-01 job. (b) Carrying out soldering as required to make leake proof-01 job. (c) Replacement of upper & lower gasket by new one-01 job replacement of nuts,bolts clamps,hoses etc as required -01 job (d) Replacement of rusted nuts, bolts,clamps,hoses etc all as required.
Replacement of defective/detoriated lead Acid batteries withnew 12 volts,32Ah maintenance free batteries complete with SMPS Charger Make:Cummins Cat No AX1013233 or equivalent in EXIDE/ SF
Replacement of defective/detoriated lead Acid batteries withnew 24V, 32 Ah maintenance free batteries complete with SMPS Charger Make:Cummins Cat No AX1013235 or equivalent in EXIDE/ SF
Supply and Topping up of coolant in radiator of DG set after draining out old water and cleaning of radiator of any capacity/type complete all as specified and directed by Engr-in-charge. Make: Servo
Supply and topping up of Distilled water in lead acid battery of DG set at GE(P) Dappar station. Complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of detoriated/damaged Battery lead with new cable assembly battery lead Cat part no:0416-0639 Make cummins or equivalent Finolex/Havells
Material & Labour for painting to DG Set of 30 KVA to 250 KVA all as specified and directed
Material and labour in replacement for rubber insulation matting 1 mtr wide class A upto 3.3 KV, chequered having thinkness 20mm. Make : Electromat or equivalent Electromat/Joyti/National
Material and labour in replacement for rope asbestos of size 10-12mm dia thermal with standing capacity complete all as directed by Engr-in-Charge
Material and labour in replacement for unsv battery charger auto type of capcity 2x12V, 6Amps for charging lead acid batteris all as specified and directed. Make : Bosch, Elak
Material and labour in replacement for unsv battery charger auto type of capcity 4x12V, 12Amps for charging lead acid batteris all as specified and directed. Make : Bosch, Elak
M&L for repairing of fuel tank including, soldering, cleaning, all as specified and directed
HARISH SALES CORPORATION
SANJEEV ENTERPRISES
TARA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .