Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹21.0 L
Closing Date
19 Aug 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Srinagar
Barbarshah Maisuma Srinagar
Internal Electrification with controlling and protection switch gear devices with fixtures etc. for Admission Block at Govt. Degree College Baramulla
2021_PWDJK_133735_1
E/NIT/73/2021/22dtd09/08/2021
Open Tender
Electrical Works
Item Rate
30 days
Internal Electrification with controlling and prot
as per BOQ
7 documents required · 7 mandatory
₹800
Executive Engineer RNB Electric Division Srinagar
Exempted
19 Aug 2021
9 Aug 2021
19 Aug 2021
9 Aug 2021
19 Aug 2021
9 Aug 2021
120 days
Amount
Point wiring for switch controlled primary light points with 3x1.5 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Finolex /Anchor /Havell’s /Polycab make in recessed or surface Conduit and incl. the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Legrand / / Havell’s / Honeywell make and colour housed in zinc chromate passivity GI boxes with modular cover plate complete as per specification and as required of reputed make ( Excl. cost Of Conduit)
Point wiring for 6 Amp Socket out lets with 3x2.5 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduct incl. the cost of supplying and fixing modular grid plate mounted flush mounted 3 no 240 volts 6 amp 3 pin socket out let along with 2 no. 6 Amp control Switch of Legrand / Havell’s / Honeywellmake and colour housed in zinc chromate passivity GI boxes with modular cover plate and inter connections and including cost of loop Earthing with 2.5 sq. mm FRLS PVC Insulated 660/1100 circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required volt grade flexible stranded copper conductor wires complete as per specifications and as required ( Excl. cost of Conduit)
Point wiring for 16 Amp Socket out lets with 3x4 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduit and incl. the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of Legrand / Havell’s / Honeywell make housed in zinc chromate passivity GI boxes with inter connection complete as per specifications and as required. ( Excl. cost of Conduit)
Supply and Fixing of Fan dimmer Modular grid plate flush mounted 240V 5 Step Electronic Speed Regulator of Legrand / Havell’s / Honeywell Make to be housed in zinc Chromate passivity G I Boxes with moulded Cover Plate of same make With Necessary Connections Complete Job.
Supply of Integral LED 4 ft luminaire with extruded housing and Opal diffuser. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. Luminaire shall be designed to emit at least 4400 nominal lumens at a system efficacy of at least 110 lumen/watt with a maximum system wattage of 40 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply of LED indoor surface downlighter suitable for general lighting with AlmuniumDiecast housing with polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1200 lumens and maximum system wattage of 12 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 , THD <10% with inbuilt surge protection of 2.5Kv. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply, Installation testing and commissioning of 1400 mm sweep Ceiling Fans of Crompton Greaves / Havel's / Usha / Bajaj make ( Sample to be got approved ) with ceiling rose of SSK make Complete incl making of necessary connections.
Supply, Installation testing and commissioning of 250 mm sweep Shutter type Exhaust Fans of Usha / Crompton Greaves / Havel's / Bajajwith way ceiling rose of SSK make incl making of necessary connections and making of necessary space in walls / Windows as per site
Supply, Installation, Testing and Commissioning of AC/DC Bells of standard make with its batteries.
Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.
wiring for Circuit/sub-main wiring along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of standard make (to be got approved before installation) in recessed or surface conducting system excluding cost of conduit of following sizes
2 x 4 SQ. mm + 1 x 4 SQ. MM Earth Wire
2 x 6SQ. mm + 1 x 6 SQ. MM Earth Wire
2 x 10 SQ. mm + 1 x 10 SQ. MM Earth Wire
2 x 16 SQ. mm + 1 x 16 SQ. MM Earth Wire
Supplying and fixing of following way prewired TP&N MCB distribution Boards of sheet steel of Legrand / Hager / Siemens / L&T/ SSK make for 415 volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, dully wired with suitable size, FRLS PVC Insulated copper conductor up to terminal block, tinned copper Bus bar, neutral link, earth bar , din bar, detachable=cable gland plate, interconnections, powder coated painted including Earthing etc. as required, ( but without MCB/RCCB/Isolator) 12 Way (12+36) Ip43 with metal door.
Supplying and fixing of 32 Amp rating DP 240/415 volts "C" curve MCB of Legrand / Hager / Siemens / L&T / Honeywell make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.
Supplying and fixing of 40 - 63 Amp rating DP 240/415 volts "C" curve MCB of Legrand / Hager / Siemens / L&T / Honeywell make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.
Supplying and fixing of 5 Amps to 32 Amp S Pole rating 240/415 volts "C" curve MCB of Legrand / Hager / Siemens / L&T / Honeywell make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.
Supply & fixing of 32 Amps Industrial type metal clad socket outlet with inter connections in heavy gauge powder coated G.I box with inter connections and proved and fitted with 32 Amps S P MCB and 220 Volt, 20 Amp 3 plug top complete job of Anchor /SSK/Legrand/Havell’s/ SSK make for A.C points.
Supply/ installation/testing and commissioning of floor mounted compartmentalized , 415 volts TPN MCCB Floor distribution panels of sheet steel of 16 gauge dust protected, painted incl. earth terminal with all necessary accessories as required for panel and of adequate size to accommodate all following accessories complete Incoming (1) 200 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T /ABB make with breaking capacity of 35 KA = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set Outgoing 100 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T make = 3 no for Output 32 amp DP MCB = 2 40 – 63 amp DP MCB = 4 Volt meter = 1 no Ammeter = 1 no CT coils for Am meter 300 /5A = 1 set Indicators = 1 sets (3 No's)
Providing of Maintenance Free Earthing System using copper bounded earthing rods 25mm in dia and 2 Mts long placed vertically in a bore well of 4 Inch in dia dully bored manually with 250 micron copper molecular bonding along with 2 bags ( 11.5 Kg each) of Ground Enhancement Material (GEM) or Equivalent with each rod to reduce the soil resistivity to a considerable value.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long, G.I. tube, having single prong at top, with 85 mm dia. 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and laying of 25x3 mm size Copper Strip in one run for extension of earthing to equipment/controlling./Lighting conductor.
Supply, laying, Connecting and Commissioning of 95 sq mm 3.5 core XLPE/PVC insulated and steel armored 1.1 KV grade Al Cable of Hovels / KEI / Paragon make laid as per site condition for three phase point
Supply, laying, Connecting and Commissioning of 50 sq mm 3.5 core XLPE/PVC insulated and steel armored 1.1 KV grade Al Cable of Hovels / KEI / Paragon make laid as per site condition for Generator supply.
Supply and Fixing of 25 mm dia medium grade PVC conduit incl. its allied accessories like bends, j boxes etc. for laying of wires recessed in walls incl. refacing of walls or fitted with necessary cliffs and rowel plugs complete.
Providing of ISI marked Dry type Co2 Type fire Extinguisher of 4.5 kg capacity fitted with High Pressure Hose, Squeeze Grip type Control Valve with self-indicating Pressure Gauge .
Supply and Drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed PVC conduit as required.
Supply and Fixing of DATA Socket out let of Legrand Make.
Supply, Installation, Testing and Commissioning of all in one integrated LED solar street lighting luminaire with housing of Die-cast aluminium, UV stabilized polycarbonate cover, having minimum system lumen output of 3000 & system wattage not exceeding 18W, 12V DC with system lumen efficacy not less than 175lm/W. Luminaire has Integrated MPPT charger with Driver with charger efficiency >90% and should be available in CCT of 5700K. Luminaire should have highly safe & Advanced long life maintenance free Lithium Iron Phosphate (LiFePO4) battery used for hassle free operations along with inbuilt PIR sensor with dimming profile. Luminaire should be capable of operating at line voltage without any separate power supply from 100-240 V AC. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade.Luminaire should be IEC60598-2-3, IEC 62109-1, EN 50530, IEC 61547, CISPR 15, IEC 62133, IEC 61960, UL1642, IEC 61730-1-2, IEC 61215 certified.
Supply, Installation and Commissioning of 15 KVA, 3Phase, 415V LT unbalanced AVR of ALBA/A E /Electric Field/ Chinar make. The servo voltage stabilizer shall operate from input voltage (L-N) =90-270V (L-L 155- 470V) thereby producing the corresponding output voltage of 415V ±5% (Phase to Phase) the servo stabilizer should further have inbuilt protections of over voltage, under voltage and overloading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di electric strength, the stabilizer shall further be capable of smooth operation upto 10% unbalanced in the load currents. The supplier has to give guarantee for any manufacturing defect with three servicing of equipment for 1 year reckoned after commissioning. ( Approved before installation )
Supplying and fixing of 200 Amp 4 Pole Changeover Switch in sheet enclosure 415 V A C ,50 Hz ( Side Handle ) Havells / Legrand Make complete with connections testing and commissioning etc Complete Job .
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches’ for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Cooper/Morley/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type High Sensitivity Laser Based Smoke detector having 9 sensitivity levels (from 0.07- 6.56%/m) Complete with Dual LED, Hard Addressable Having rotary decade Address switches from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly approved by EN54/LPCB/VDS/UL/BSA including of mounting Base as required. (System Sensor/Safeway/Cooper/Morley/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Strobe type electronic hooters conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/ with mounting base, housed in sheet steel / Polymer housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 dully approved to GEA GE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, installation, testing and commissioning of Intelligent Analog Addressable Type Control/Output Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99, for initiating Hooter/Sounder/Strobes etc. dully approved to GEA GE1-082conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Addressable type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/ASES) ( Approved before installation )
Supply, installation, testing & commissioning of 4 Loop Microprocessor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, sealed to IP30. The Panel Shall have 20 Zones with Individual LED Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation, Testing and Commissioning of 200 Amps By Pass Four Pole switch of Havell’s/Legrand/HPL Make, Incl. its sheet steel enclosure with angle iron stand and handle with making of necessary connections complete job. ( Approved before installation )
M/S MOHD ASHRAF MIR
MIR ELECTRONICS
M/s JK SECURITY SOLUTIONS
JUNAID ELECTRICAL AND ELECTRONICS
M/S MIR ENGINEERS
M/s AHMADULLA AND SONS
M/s NEW LIGHT ENTERPRISES
Pir Panchal and Co
M/S ZARGAR ENGINEERING WORKS
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .