Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2ND FLOOR 4 329A OLD MAHABALIPURAM ROAD CHENNAI TAMIL NADU CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | Admitted-Finance |
| 2 | Admitted-Finance B 161 GIDC ELECTRONIC ZONE SECTOR 25 GANDHINAGAR 382044 GUJARAT | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382044 | Admitted-Finance |
| 3 | Admitted-Finance 17TH FLOOR UNIT NO 1 TOWER 1 PS SRIJAN CORPORATE TECH PARK PLOT NO 2 BLOCK EP GP SECTOR V SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
18 Dec 2023, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LS Nagi
Technip Energies India Limited, Technip Tower, A-4, Sector-1 Noida-201301, India
Design, Engineering,manufacturing, procurement of materials and bought out components, assembly at shop, Inspection including inspection by TPIA, Testing at manufacturers works, packing, supply of AC UPS
2023_REFHQ_171644_1
TP/81757C001/RFCC/1671-01/1120
Limited
Electrical - All
Supply
180 days
Refer tender details
Not Applicable
5 documents required · 5 mandatory
Exempted
15 Apr 2024
6 Oct 2023
20 Dec 2023
6 Oct 2023
18 Dec 2023
18 Oct 2023
6 Oct 2023 - 25 Oct 2023
2 X 100% Redundant (Non Parallel) UPS (2 X 40 KVA rating), 110 V AC, 50 Hz, Single phase) system shall consist of - - AC UPS Panel -Fault diagnostic unit (FDU) -Nickel Cadmium (Ni-Cd) Battery (60 Min Back up) – 1 x 100% (with each UPS) -Battery rack / stand -Double pole battery isolator switch / breaker -AC distribution board (ACDB) with two incomer and bus coupler scheme as per SLD and UPS ACDB schedule -UPS-PDB with two incomers and static switch as per UPS ACDB schedule. -Cell booster of adequate rating -All associated power (copper) / communication cables -Static & Maintenance switches -Bypass transformer (Refer figure-4 of Job specification for supply of AC UPS & other details as per the material requisition.)
Mandatory Spares for item no-1.00, details as per material requisition.
Site work (Testing, Pre-commissioning and commissioning,details as per the material requisition)
Unit rate for Supervision of erection/ installation for item no.-1.00 as per enclosed instructions to vendor Per Diem charges upto 8 hrs on normal working days. (BIDDERS TO QUOTE UNIT RATE FOR DIEM CHARGES )
Unit rate for Supervision of erection/ installation for item no.-1.00 as per enclosed instructions to vendor Overtime rate per hour (beyond normal 8 hours on normal working days). (BIDDERS TO QUOTE OVER TIME RATE PER HOUR )
Unit rate for Supervision of erection/ installation for item no.-1.00 as per enclosed instructions to vendor Overtime rate per hour for work on weekly off days / holidays (as applicable to Refinery Site). (BIDDERS TO QUOTE OVER TIME RATE PER HOUR )
Description of Work / Item(s)
2 years Normal operational & maintenance spares (as per vendor recommendation) (Spare no. - 5.01 (as mentioned in the unprice schedule)
Spare no. - 5.02 (as mentioned in unprice schedule)
Spare no. - 5.03 (as mentioned in unprice schedule)
Spare no. - 5.04 (as mentioned in unprice schedule)
Spare no. - 5.05
Spare no. - 5.06
Spare no. - 5.07
Spare no. - 5.08
Spare no. - 5.09
Spare no. - 5.10
Spare no. - 5.11
Spare no. - 5.12
Spare no. - 5.13
Spare no. - 5.14
Spare no. - 5.15
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 16 A fully equipped FSU outgoing feeder with isolation transformer
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 63 A fully equipped FSU outgoing feeder with isolation transformer
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 160 A fully equipped FSU outgoing feeder without isolation transformer
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 16 A fully equipped FSU outgoing feeder
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 63 A fully equipped FSU outgoing feeder
Unit Rate for Addition / Deletion for Outgoing feeder from ACDB, as per requirement of doc. 081757C001-701-DW-1654-003-0 - 100 A fully equipped FSU outgoing feeder
VERTIV ENERGY PRIVATE LIMITED
Hitachi Hirel Power Electronics Pvt Ltd
VERTIV ENERGY PRIVATE LIMITED
Hitachi Hirel Power Electronics Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .