GE 871 EWS
GE 871 EWS
SPECIAL REPAIR TO BUILDING NO T- 46 OF GARHWAL SCOUTS UNDER GE 871 EWS AT JOSHIMATH
2021_MES_449814_1
8598/E8
Open Tender
Civil Works
Works
120 days
JOSHIMATH
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹26,000
Yes
5 Aug 2021
9 Jun 2021
9 Jul 2021
9 Jun 2021
7 Jul 2021
23 Jun 2021
9 Jun 2021 - 22 Jun 2021
Amount
Dismantling plain corrugated steel sheeting of any gauge/thickness including Nainital and similar pattern all as specified and directed.
Dismantling of wall and ceiling board of any thickness including cover fillets all as specified and directed.
Dismantling of frame work timber in scantling 40 sqcm and over in section in any position all as specified and directed.
Dismantling of frame work timber in fillets, rails, posts, rafters, purlins under 40 sqcm in section all as specified and directed.
Taking down chowkat with shutters (without taking off shutter from the frame) area exc. 1.5 sqm but nexc. 4 sqm each all as specified and directed.
Taking down door/window shutter/cupboard shutter with frame (without taking off shutters from the frame) area up to 1.5 sqm each all as specified and directed.
Demolition of cement concrete in ground floor and paving nexc 15 cm thick (below or above ground level) all as specifed and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for all as specified and directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete block walling all as specified and as directed.
M&L PCC 1:4:8 type D 2, (using 40mm graded stone aggregate) in foundation all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded crushed stone aggragate) as in foundation filling and mass concrete all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping including form work all as specifed and directed.
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in leveling course, finished surfaces even and rough to receive floor finish all as specifed and as directed.
S&F ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979 grade Yst 240 as in post including fabrication and erection and fixed in position all as specified and directed.
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W (Gde E-250 quality- A) all as specified and directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410-W (Gde E-250, quality- A) all as specified and directed.
S&F 16 to 20 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and nexc 30cm long all as specified and directed.
S&F 11 to 15 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and nexc 15cm long all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specifed and directed.
M&L RCC M-25 grade design mix (using 20 mm graded crushed stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete all as specified and directed.
M&L RCC M-25 grade design mix(using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L RCC M-25 grade design mix (using 20 mm graded crushed stone aggregate) as in chajjas all as specified and directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams all as specified and directed. sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter, finshed flat rough finished surfaces all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, finshed flat rough finished surfaces all as specified and directed.
Use and waste formwork to chullah hoods, chajjas, troughs and similar items including edges, finshed flat rough finished surfaces all as specified and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape, required including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
All as per Item No 27 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.
M&L precast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in solid building blocks, exc. 10 cm in width and setting in CM (1:6) all as specified and directed.
M&L walling of random rubble uncoarsed, well bonded bedded and solidly hearted built in CM 1:6 all as specifed and directed.
All as per item No 30 here in before but except stones all as specifed and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished surfaces even and smooth without using extra cement in internal surfaces of wall all as specified and directed.
M&L rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:4), finished surfaces even and smooth without using extra cement on external surfaces of wall all as specified and directed.
M&L preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty all as specified and directed.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of primer all as specified and directed.
M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 but nexc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and laid over a screed bed of 15 mm thick in CM 1:6 all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but nexc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles all as specifed and directed.
M&L prepolished chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floor with grey cement and pigment including laid over screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortor 1:6 all as specified and directed.
S&F frame work for suspended false ceiling, GI exposed ceiling suspension system of grid size 600mm x 600mm with main runner 38mmx24mm, cross tee 29mmx24mm and wall angle 24mmx24mm to form a grid of GI system duly suspended with 4mm dia GI/MS bar hanger fixing with steel dash fastner or iron purlins from the roof with adjustment clip providing in position for light fixture all as specified and directed.
S&F false ceiling of Everest designer boards of size 595 mm x 595 mm x 4 mm thick fixed on GI snap grid all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection, 75 mm thick, finished surfaces even and smooth without using extra cement all as specified and directed.
S&F pressed steel frames for doors with one or more rebates (size of frame 125x60mm) including necessary fixing lugs, hinges, lock strike plate all as specified and directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F powder coated aluminum section for making frame and shutters of doors, windows, partition wall, shutters etc including styles & rails with standard anodized aluminum section, with one or more rebates including aluminium snap beading all as specified and directed (Glazing, rubber beading, hinges etc shall be measured and paid separately)
S&F Aluminium anodised DG 102 "DECO" grill of size 100mm x 10mm x7mm thick, approved design for windows/ ventilators with and including F/U channel all as specified and directed.
M&L rubber beading for fixing glass panes in aluminium frame work all as specified and directed.
S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty and fixed to aluminium shutters in square nexc 0.5sqm in each pane all as specified and directed.
M&L for preparation of new steel surfaces of any description,over 10cm in width or girth, not otherwise describedand applying two coat of synthetic enamel paint on roof over a coat of red oxide primer complete all as per specified and directed.
M&L preparation of new wooden surface of any description over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed.
S&F butt hinges medium weight cold rolled mild steel 100mm all as specifed and directed.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
S&F 150 mm long anodised extruded aluminium alloy handles, fabricated type all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified and directed.
S&F in repair floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size) all as specified and directed.
S&F in repair 20 mm dia chromium plated pipes for curtain rods all as specified and directed.
S&F in repair chromium plated brackets and knobs for curtain rods all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, light fitting and removing materials to store for keeping in safe custody for taking credit or reuse serviceable fittings/fixtures and making good the disturbed surfaces of wall/floors all as specified and directed.
Dismantling old existing submain wire of any size all as specified and directed.
Dismantling unserviceable old existing XLPE/service cable of any size all as specified and directed.
M&L point wiring concealed type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps all as specified & directed.
One socket outlet 5/6 Amps on independent board controlled by one switch all as specified & directed.
One socket outlet 5/6 Amps controlled by one switch on same board with other switches all as specified & directed.
All as per item No 60 here in before but one socket out let 15/16 Amps controlled by one switch on independent board and wiring with 2.5sqmm cable all as specified & directed.
S&F switch piano flush type single pole, 5/6 Amps one way, 230 volts all as specified & directed.
S&F switch piano flush type single pole, 15/16 Amps one way, 230 volts all as specified & directed.
S&F socket outlet 5/6 Amps flush type piano 5 pin 230 volts all as specified & directed.
S&F socket outlet 15/16 Amps multipurpose 3 pin 230 V all as specified & directed.
S&F ceiling rose surface bakelite 62.5x25 mm size 3 terminals all as specified & directed.
S&F in replacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one No MCB, SP, 20 Amps, 230 Volts, 10KA 'C' series all as specified and directed.
Supply and fixing LED lights fitting 1x18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose all as specified & directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified & directed.
S&F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified & directed.
S&F in repairs MCB DB sheet metal enclosure single pole and neutral 230 V with 200 Amps standard bus bar of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mounting type double door factory fabricate complete without MCB and with encosure blank plates for unused way suitable for 8 way flush in wall complete all as specified & directed.
S&F MCB SPN 40 Amps 240 Volts C, series all as specified and directed
S&F MCB 6 to 40 Amps SP, 240 Volt C, series all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 metre above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm TMT bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ looose soil and deposited the surplus soil to a distance nexc 50 metre away from starting point, all as per electrical plate no 3 of SSR part-1 all as specified & directed.
M&L sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable size 4.0 sqmm drawn in and including PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing all as specified & directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid as one unit length.
Supply laying and testing in trenches, fixed to wall/pole cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core all as specified and directed.
Excavation in trenches nexc 1.5 metre wide and nexc 1.5 metre deep in depth for laying of underground cable in hard/dense soil and getting out all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers nexc 25 cm thick layers all as specified and directed.
Removal of excavated material nexc 50 metre away and depositing where directed at a level nexc 1.5 metre above from starting point all as specified and as directed.
M&L sub-class 'B' bricks, well burnt, laid breadth wise along the length for cable laid in trenches over sand cushion laid for UG Cable protection, all as specified and directed.
M&L sand cushioning dry fine for cable cushioning 8 cm below the cable and 15 cm above cable all as directed.
Material and labour 32 mm dia galvanised steel tubing light grade for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers all as specified and directed .
AJAY KUMAR CONTRACTOR
SIDHARTH CONSTRUCTION
M/S BHAWANI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .