| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹73.4 L+₹2.3 L (3.20%)Rejected-Finance HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹73.8 L+₹2.7 L (3.81%)Rejected-Finance OLD MISSAMARI PO GARUBANDHA PS MISSAMARI DISTT SONITPUR ASSAM 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹82.4 L+₹11.3 L (15.9%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
6 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL SUNIL PILLAI
HQ CWE TENGA PIN-900194 C/o 99 APO
REPAIRS TO CERTAIN BUILDINGS AT MISSAMARI MILITARY STATION UNDER GE MISSAMARI
2023_MES_616488_1
8385/E8
Open Tender
Civil Works
Item Rate
180 days
GE MISSAMARI
C (a) (i)
8 documents required · 8 mandatory
₹1,000
GE MISSAMARI
₹1.5 L
Yes
25 Nov 2023
31 Aug 2023
13 Oct 2023
31 Aug 2023
6 Oct 2023
21 Sept 2023
Amount
M & L for Preparation of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement and removal of debris to a designated location (upto full height) block to support the structure provisionally during repair work and maintaining them in position till required, complete all specified and directed by the Engineer-in-charge. (Note:- Scaffolding, debris disposal and enabling items will be paid separately).
M & L for Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving, applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent with a coverage of 350gm/sqm on the existing rebar and allowing it to react with rust for 6 hrs and forma corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats.
M&L for Providing and application of zinc rich epoxy anticorrosive protective coating for rebar corrosion protection system Sika Friazinc R® or equivalent in 2 coats of 0.4 kg/m2. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78.
M &L for Making V groove of 10mm wide and 30mm deep or upto the extend of crack present at site over crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engineer-In-Charge. The groove shall be cut on the concrete surface along the crack over beam or column to be repaired Note: Work to be executed by the authorised applicator of manufacturer only.
M &L Sealing of exposed 'V' groove of 10mm wide and 30mm deep with Sikagard 694 F(I) or equivalent solvent-free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface levelling mortar. Note: Work to be executed by the authorised applicator of manufacturers only.
M&L for Drilling & fixing 12mm dia up to 50-75 mm long injection packer in structural members at the interval of 300 mm in staggered manner in reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive SikaDur 31 or equivalent to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
M&L for Grouting injecting two part, low viscosity, moisture insensitive injection-liquid at damp substrate location, based on high strength epoxy resin Sikadur®-53 UF or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 500 mPas at +30°C and should comply according to ASTM C 882 and should have below properties. Compressive strength >= 50 N/mm2 (7 days) according to ASTM C 579; Tensile Strength ~ 30 N/mm2 (after 14 days at +30°C cure) (According to ISO 527); Tensile Adhesion Strength >8 N/mm2 (failure in concrete) after 14 days at +30°C cure. Seal the nozzle with Sikagard 694 F (I) or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost.
M&L for Drilling & Rebaring of 16mm/12mm dia x 160mm deep additional corrosion resistant hot dip galvanised steel rebar Fe415 or height grade as per required diameter in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical or equivalent complete.
M&L for TMT reinforcement bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for Columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and as directed.
M &L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacture specification including preparation of surface by chipping and thoroughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge with Sikadur®-32 LP in consumption of 0.4 kg/m2. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa.
M&L for Rebuilding the section of damaged RCC elements to its original size in thickness of 40mm by hand or spray application by Providing and applying Sika MonoTop®-122F single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar.
M & L for water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete all as specified and directed by the Engineer-in-charge.
M &L for Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendation in thickness of 40-100mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete SikaRep Microcrete-4 or equivalent having compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and supporting formwork, all lead lift, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any to satisfaction of Engineer-in-charge and curing.
Supply and apply a stitched, one directional, high strength CFRP fabric SikaWrap® 230C in single layer over girders as per specification after surface preparation by rounding off sharp edges to 25 mm radius and cleaning it properly including thixotropic epoxy based impregnating resin / adhesive Sikadur®-330 (IN) for low density fabric for base and top coat. Wrapping the CFRP fabric to girders at desired orientation using tamping rollers to avoid any air voids etc. and sprinkling sand over it as per direction and satisfaction of Engineer-in-charge. CFRP product used shall have minimum requirements: tensile strength (nominal) = 3800N/mm2; tensile E – modulus = 2.3x105 N/mm2; elongation at break (nominal): 1.7%; fabric design thickness = 0.131 mm.
Demolition of cement concrete in roofs, floors(other than ground floors), staircase, landing and similar suspended work.
M&L for brushing neat cement slurry with 03 Kg of cement per Sqm complete all as specified and directed.
M&L 25 mm thick cement concrete PCC Type B0 1:2:4 using 12.5 mm graded aggregate complete all as specified and directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top including taking down existing treatment complete all as specified and directed. (i) Screed bed or bedding layer 10 mm thick in CM 1:4 as in roof Slab including preparation of surface to receive screed bed. (ii) Applying one coat of cold bituminous primer 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces. (iii) APP based polymeric membrane 3mm thick, minimum weighing 3.5 Kg/sqm, reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction and sealing the joints with application of cold bitumen. (iv) Applying two coats of aluminum paint over the APP membrance .
Disconnecting exc 250 & n exc 500 ltr existing tanks, setting aside (or lowering ) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position.
Dismantling water tanks and removing to store exc 250 & not exc 500 ltrs
S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed.
Taking down cement plaster including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site.
M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth.
M&L for rendering 20mm thick plaster in CM 1:4 mixed with water proofing compound on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only for water proofing compound, complete all as specified and directed.
M&L for preparation of new plastered/putty surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered surface to prepara-tory to distempering complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint over a coat of Priming plastered and other surfaces with alkali resistant priming paint.
Form work for side of pillars, posts, columns & similar works vertical or batter.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for PCC 1:2:4 Type B0(12.50 mm using) cement concrete in roof kerbs or mud stops, rounded or chamfered on edges On horizontal surface: all as specified and as directed incl demolition of old PCC.
On vertical wall/surface : Supply and apply a protection plaster 15 mm thick 1 : 4 admixed with Sika® Plastocrete Plus @100ml per 50kg bag cement Product requirements admixture: conforms to IS 2645.
Supply only Sika® Plastocrete Plus
M&L for repair to pot holes, bug holes, surface irregularities, damaged concrete slab, if any, with a latex polymer modified repair mortar including a coat of bonding agent of the same by providing and applying a bond coat of Sika Latex : Water : cement - 1:4:6 with sika Latex consumption @100gm/sqm on the floor & wall surface followed by hand mix of cementitious mortar 1:3 to be mixed with adding permeability reducing polymer Sika Latex @ 400gm/sqm (6%) by weight of cementitious content at time of mixing with water including all material, labour, tools and tackles complete Maximum avg upto 12mm. Treating the existing cracks if any by opening them into V grooves by fast curing single component Polyurethane joint sealant Sika Hyflex including the following complete all as specified and directed.
Markson
DHEERAJ CONSTRUCTION
M/s Harjas Construction & Waterproofing Co
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .