Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.4 L+₹41,894.05 (3.00%)Rejected-AOC | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
26 Nov 2020, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2020_MES_394424_1
8563
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹29,000
Yes
19 Jan 2021
11 Nov 2020
28 Nov 2020
11 Nov 2020
26 Nov 2020
14 Nov 2020
11 Nov 2020 - 13 Nov 2020
Amount
Dismantling single layer manglore pattern or similar tiles in roofing complete.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated or tile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ150 as in roof covering/ cladding to wall, fixed with self tapping screws complete.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ150 as in roof covering/cladding ridge or hips, valley gutter to wall, fixed with self tapping screws complete.
Dismantling wooden boarding any description, fixed in any position with nails complete.
Dismantling ceiling and wall boards or insulation board any thickness including cover fillets complete.
M&L for 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh to hanging of size of grid 605x605 mm, Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete
Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc. Complete
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, complete
M&L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete
M&L for Brickwork with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement)
M&L Rendering in two layer on other than fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately) complete.
Supply only Internal water proofing compound
M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distamper over and including a coat of 3mm average thick birla/ equivalent wall care putty and one coat of chalk whitening primer complete
M&L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distamper over a coat of chalk whitening primer complete.
M&L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of primer on external wall complete.
M&L for preparing old decorated surfaces of wall and applying two coat of cement base paint on external wall complete
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sqm but n.exc 4.00 Sqm each complete
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm complete
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete.
S&F anodised aluminium window shutters, side hung/sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips, rubber neoprene packing, handles 01 No in each shutter, 02 Nos hinges per shutter, anodised aluminium snap beading, screws etc. as per manufacturers instruction & trade practee complete.
M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved complete.
S&F for pressed steel doors frame with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, stainless steel hinges, lock strike plate, etc., complete.
M&L for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in filling hollow portion of pressed steel door frame complete
M&L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete.
S&F 4.00mm thick figured glass, pin head type and glazing with rubber beading or with glazing clips complete.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work con- forming to Fe.290.Gde-E-165 complete.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete.
M&L for 100 mm butt hinges stainless steel grade 202, 14 gauge thickness medium weight fixed with pressed steel door frame / pvc door frame with screws complete
S&F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete
S&F 150 mm size extruded aluminium alloy handles, febricated type anodised complete
S&F 300 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters complete
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete.
S&F 500 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position including dismantling of old and removing complete
S&F Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut, screwed for iron pipe or brass ferrule and fixed complete
Repairs by brushing of treatment to reinforcement by application of corrrosion resisting coat in two coats, suitable time to be provided between coats according to manufacturers instructions to resist further deteroriation of reinforcement etc. complete.
Repairs by application of approved epoxy based bond coat on concrete surfaces or sound bonding of cold and new concrete surfaces complete.
M&L for Making of profile of structral memebers with polymer modified mortar in damaged areas in CM 1:3 with 5 -10 percentage addition of latex polymer, w/c ratio of 0.35 in 20 mm thk layers / including leveling etc complete.
M&L for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with PCC (1:1.5:3) type A0 using 12.5 mm graded aggregate) in any slab and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and weldign/binding of reinforcement ( including reinforcement) if required complete and applying 3 coats of white wash / 2 coats of cement base paint to match with existing surfaxes complete. ( Note reinforcement will be measured and pai seperately under respective items)
M&L for Reinforced cement concrete (nominal mix) type B1 (using 20mm graded crushed stone agg) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete
M&L MS TMT bars 8-10 mm dia, cut to length bent to shape required including cranking/ Binding/ hooping of coloumns/hooking ends and binding with and including MS wire ( annealed) not less then 0.9 m dia or securing with clips complete
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete
S&F in 25mm dia stainless steel 202 grade tubular curtain rod complete
S&F in stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be as approved) complete
Complete removal of existing unservicable roof treatmen incl taking down plaster, padding of any description and any position, cleaning, flushing out junctions of parapet wall washing down with water etc to prepare surface for new WPT including removing off rubbish at out side MD land complete.
M&L for 50mm average thick PCC padding in Cement concrete (1:2:4) type B0 (Using 12.5mm graded stone agg) mixed with liquid water proofing admixture as per manufacturer's instructions finished even and smooth without using extra cement for laying of WPT WPC measured seperately) complete.
M&L for rendering 10 mm thick on roof surface or concrete surfaces in CM 1:4 for finished even and smooth without using extra cement complete
M&L cleaning of concrete surfaces and applying priming coat using with bituminous primer @ 0.30Ltr per Sqm followed by evenly a tack coat @ 1.20 kg per Sqm using with 85/25 grade industrial bitumen , over it laid with APP modified polymeric water proofing membrane with non-woven polyester reinforced of weight not less than 3.0 kg per Sqm 3mm thick of unrolled & bonded to substrate with side and end laps 75mm & 100mm as per manufacturer’s instruction and applying over it a tack coat using with 85/25 grade industrial bitumen @ 1.20 kg per Sqm and finally finished the top of polymeric water proofing membrane with a coat of bituminous aluminum paint @ 0.200 kg per Sqm as per manufacturer’s instructions complete
Dismantling ballies, hard or soft wood, type 2, any position, except in posts and struts; including taking out iron straps, bolts and nuts, etc., if any complete
Dismantling timber scantling under 40 Sqcm in section as in fillet, rails, posts, rafters, purlins etc complete
S&F in Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 incl painted one shop coat of zinc chromate primer paint after preparation of surfaces at workshop before fabrication complete
Roughning of old unservicable PCC floor surface by picking, chipping and wire brush sweeping clean and washing down with water to remove dust outside to make it suitable for laying floor tile complete
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick, area of each tiles exceeding 0.18sqm and n. exc 0.38 sqm in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15mm thick in cement mortor (1:6) complete.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick, area of each tiles exceeding 0.18sqm and n. exc 0.38 sqm as in skirting/dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 10mm thick in cement mortor (1:4) complete.
Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete.
Dismantling and taking out submain wiring 2/3/4/6 wire of any size, segregating for material for reuse, making good disturbed surface of walls/floors to match with existing surface and taking out from site complete.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade, conforming IS 694 & color code in conduit system of wiring, drawn in including medium grade PVC conduit not less than 20 mm dia concealed, including cutting chases, finising of slote by means of cement mortar making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.6mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet6 fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit for One light point controlled by one switch 6 Amp one way complete.
All as described as per item No 60 above but for One fan point controlled by one switch 6 Amp one way
All as described as per item No 60 above but for One bell point controlled by one switch 6 Amp one way
All as described as per item No 60 above but for One 3 pin switch socket combination 6 amp on the independent board.
All as described as per item No60 above but for One 3 pin switch socket combination on same board with other switches.
All as described as per item No 60 above but for point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
All as described as per item No 60 above but for point wiring with 4.0 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 4.0 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point or sheet metal enclosures with socket plug top with MCB on independent board.
S&F in repairs MCB DB SPN 08 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs / Isolators / RCCBs etc complete.
S&F in repairs MCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete.
S&F for in repairs MCB SPN 5 to 40 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete. (DB will be measured and paid separately under respective items of sch A):-
All as described as per item No 63 above but for MCB SP 5 to 40 Amps
S&F in repairs DX3 RCBOs double pole 240Volt, AC type 30mA ISI marked as per IS-12640-2 integrated label holder, ergonomic design with colour cooled ON/OFF indicatio o dolly with front face indication for earth leakage fault having IP020 protected terminals of size 35 sqmm of 25 Amps capacity complete.
S&F in repairs MCB TPN 4pole 63 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete. (DB will be measured and paid separately under respective items of sch A)
M&L switch piano flush type single pole, one way 6amp, 240V complete.
M&L switch socket combination 2 in 1, 5 pin 6 amp, 240 V complete.
M&L switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type 240 V complete.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. Complete
S&F ceiling rose 65x17mm three terminals 230/250V, ISI marked complete.
S&F lamp holder, PVC/Polycarbonate type and back plate suitable for batten fitting alongwith 9watt LED lamp complete.
M&L flush type bell push 6 amp, 240V duly marked for bell complete.
M&L Electronic ding dong bell AC 230V single pole complete. make Anchor/ Bajaj
Refixing sub main wiring as retrived from ( item No 59.00 ) here in before,and including rerouting if required of any size complete.
S&F in repairs sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion including taking out old complete.
M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 6.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Supply, Fixing, Testing and commissioning in repairs of 4' LED not less than 1X18W LED Batten with LED tube not less than 18 watt complete.
S&F in repairs ceiling fan 1200 mm sweep including fixing of down rod and connection complete with & including provision of flexible three core PVC insulated multi-stranded copper conductor cable of size 0.50 Sqmm from ceiling rose/connector to fan complete all as specified and directed. Make : Usha/Bajaj/Havells. Note : Old unserviceable fan shall be deposited to AGE E/M store yard through RV.
Supply, testing and commissioning in repairs a low glare, high effeciency recessed mounted LED downlighter luminaire, Type : LED down light, systen Power consumption not more than 15W, Operating Voltage 170V-270V AC complete.
Supply, fixing, testing and commissioning in repairs Light source LED, Power consumption not more than 36W, Voltage 220-240V AC 50 Hz, complete.
Supply, Fixing, Testing & Commisioning in repairs of 2' 10W Mirror LED Batten with LED tube complete including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete.
S&F in repairs wall security light 25 Watt LED type complete with GI bend 1.2 mtr and fixing on wall/pole with clamp, nut & bolt complete.
M&L for making hole in existing wall of 230mm thickness, suitable for housing of 380 mm sweep Exhaust fan including grouting of 04 Nos bolt fasteners, PCC work etc including making good disturbed surfaces complete.
Supply, fixing, testing & commissioning of Exhaust fan 225 mm sweep, aluminum rust proof body & blades, with louvers for protection from birds, 230 Volt AC supply, rated power input not more that 45watt, with louvers fixed outside bldg for auto opening and closing connecting up including provison of cable from ceiling rose to fan complete.
S&F PVC rigid conduit medium grade suitable for telephone wiring concealed on wall floor ceiling etc of size not less than 20 mm including all fitting like bend elbow socket reducers etc complete
S&F PVC Junction boxes 1-4 way with cover suitable for PVC rigid conduit of size 20 mm dia complete.
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan and getting out in soft/loose soil complete
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil complete
M&L for sand cushoning, to cable with river sand and punning to provide required cover for UG cables complete.
M&L brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm complete.
Supply and laying or fixing or passing through pipe, XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 25 sq. mm 3.5 Core complete .
M&L for galvanized steel tubing Medium grade Grade of 40 mm dia protection of cable fixed to pole/walls with clamps made from FI 25x6mm, bolts, nuts and washers etc complete.
M&L for galvanized steel tubing light Grade of 40 mm dia protection of cable laid in floors, road crossing ducts with all necessary fittings and fittings etc complete.
PATELS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .