| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.7 L+₹2.9 L (26.6%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹14.6 L+₹3.7 L (34.5%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
23 Nov 2022, 6:00 pmClosed
Nitesh Kumar Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8420 OUTSOURCING OF SERVICES FOR MAINTENANCE / REPAIRS TO COOLING APPLIANCES SPLIT AND WINDOW TYPE AIR CONDITIONERS, WATER COOLERS, REFRIGERATORS AND DEEP FREEZERS IN NSTL AREA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM.
2022_MES_561051_1
AGE I R AND D NSTL VIZAG 8420
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Visakhapatnam
Class E, Category c(i) and d(v)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹28,000
Yes
1 Feb 2023
2 Nov 2022
25 Nov 2022
2 Nov 2022
23 Nov 2022
9 Nov 2022
Amount
Outsourcing of services for general maintenance of cooling appliances like window/ split type ACs, water coolers, refrigerators, deep freezers installed in various buildings of NSTL including attending to repairs & carrying out periodical servicing, leak testing etc. by replacing worn-out spares, charging of refrigerant gas etc. including necessary T&P and consumables required for welding/ brazing works etc. complete by engaging requisite manpower in General shift of 08 hours/ day on all days excluding Sundays & Public holidays complete all as specified and as directed. Minimum manpower to be engaged: One Skilled Refrigeration Mechanic in General shift of 08 hours per day on all days excluding Sundays & Public Holidays. [Notes: Spares require replacement, refrigerant gas & Nitrogen gas required for leak testing shall be measured and paid separately as 'Supply only' and the fixing / charging element deemed to be included in the quoted rate]
Supply only sealed compressor unit working on 230 Volts AC supply suitable for 2 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star]
Supply only sealed compressor unit working on 230 Volts AC supply suitable for 1.5 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star]
Supply only cooling coil unit suitable for 1.5/ 2 TR split type AC of any make/ model. [Make: As per OEM]
Supply only Copper condenser unit suitable for 1.5/ 2 TR split type AC of any make/ model. [Make: As per OEM]
Supply only starting capacitor of 60 mfd capacity for water cooler. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only starting capacitor of 80 mfd capacity for water cooler. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only starting capacitor of 45 mfd capacity for 1.5 TR capacity window/ split type AC. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only starting capacitor of 50 mfd capacity for 2 TR capacity window/ split type AC. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only suction valve of size 5/8" as required
Supply only discharge valve of size 1/4" as required
Supply only blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suit the existing window type AC all as directed. [Make: As per OEM]
Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V of 1/8 to 1/5 HP capacity to suit the out door unit of split type AC all as directed. [Make: As per OEM]
Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity all as directed. [Make: As per OEM]
Supply only fan blade set suitable for window/ split type AC of any capacity.
Supply only remote control with PC board complete suitable for existing model of split type AC of any capacity. [Make: As per OEM]
Supply only fan motor capacitor of 2 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 4 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 6 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 10 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 15 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only condenser fan motor, single shaft 1/35 HP capacity, working on single phase, 230V AC for water cooler. [Make: As per OEM]
Supply only condenser fan motor, single shaft 1/83 HP capacity, working on single phase, 230V AC for water cooler. [Make: As per OEM]
Supply only fan blade set suitable for water cooler of any capacity.
Supply only PVC insulated flexible cable 3 core 4sq.mm size copper conductor. [Make: Finolex/ L&T/ Polycab]
Supply only 15mm dia PVC flexible pipe 600mm long complete for water cooler of any capacity. [Make: Prayag/ Water Tec]
Supply only Refrigerant gas 'R- 22' in manufacturer's sealed cylinder. [Make: Floron/ Mafron/ Retron] [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.]
Supply only Refrigerant gas 'R- 32' in manufacturer's sealed cylinder. [Make: Floron/ Mafron/ Retron] [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.]
Supply only Nitrogen gas in manufacturer's sealed cylinder for leak testing. [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.]
Supply only set of MS Powder coated mounting brackets for 1.5/ 2.0 TR AC Outdoor unit, heavy duty including necessary expansion fasteners.
Supply in repairs indoor and Out door for PCBs of indoor/ outdoor unit of split type AC of any make/ capacity complete all as directed.
Disconnecting and Taking down outdoor unit of split Acs of 1.5/2.0TR capacity, dismantling the shell, scrapping old painted steel surfaces to remove rust and painting the surfaces with two coats of synthetic enamel paint and assembling, refixing the unit and connecting up complete all as specified and directed.
Supply only PVC flexible pipe for condensed water drain fitted with clamps/concealed suitable for window/Split type Acs in wall/roof complete all as specified and directed.
Supply only power transformer suitable for split/window Acs coplete all as specified and directed.
Supply and fixing single pole MCB 20-32 Amps complete all as specified and directed.
Supply and fixing Copper pipe suitable for suction line AC Indoor/ Outdoor including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe,Clamps fixing for copper coil 01 Meter PVC corrugated pipe shall be measured as one unit length.
Supply and fixing Copper pipe suitable for discharge line AC Indoor/ Outdoor including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe,Clamps fixing for copper coil 01 Meter PVC corrugated pipe shall be measured as one unit length.
Supply only fare nuts of size 5/8'' made out of brass complete all as specified and directed.
All as above item No. 38.00 here-in-above but 1/2'' complete all as specified and directed.
All as above item No. 38.00 here-in-above but 1/4'' complete all as specified and directed.
Supply only 5/8''X1/4'' dia tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC all as specified and directed. Note:- 01 Meter of 5/8''internal dia ,01 Meter of 1/4'' internal dia shall be measured as one unit length.
Supply and Valve dummy caps made up of Brass of size 5/8"
Supply and Valve dummy caps made up of Brass of size 1/2"
Supply only aganist repairs indoor unit of split type AC of capacity 1.5 TR ,coil made up of copper with display for temperature indication and all connected accessories like blower motor,blower / blade, PCB, etc., complete all as specified and as directed. Make:- Bluestar/Carrier/voltas or equivalent.
Supply only aganist repairs indoor unit of split type AC of capacity 2 TR ,coil made up of copper with display for temperature indication and all connected accessories like blower motor,blower / blade, PCB, etc., complete all as specified and as directed. make:- Bluestar/Carrier/voltas or equivalent.
Supply only PVC Pipe of 65 mm dia of density 6kg/mtr for fixing between indoor and out door units inside the walls of appropriate lengths and closing the balance holes with PCC/Birla white/Glass putty and making the surface finishes even as directed by Engineer in charge
Supply only sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts all as specified. [Make: Legrand/ Standard/ L&T]
Supply only metal plug top 15 Amps. [Make: Anchor/ Cona/ GM]
Supply and fix in replacemnt of Outdoor unit body cover suitable for existing model of Split AC of capacity 1.5/ 2.0 TR including removing of old rusted/ unserviceable body cover and taken as credit complete with all necessary requisite spares as required all as specified and as directed.
M & L for Detecting the gas leakage, rectifying the defects by vaccumising and charging fresh mafron gas (r-32) and commissioning and testing the split/ window type air conditioner unit1.5/ 2.0 Ton capacity complete all as specified and as directed.
M & L for taking out Split/ window type air conditioner 1.0/1.5/2.0 Ton capacity of any make from its original position and shifting of AC from existing location to new location complete installation and testing including making good of old location complete all as specified and as directed by Engr-in-charge.
ANAND ENTERPRISES AND ENGINEERS
Sigma6
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .