Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹38.7 L+₹3.8 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹40.2 L+₹5.3 L (15.2%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹41.3 L+₹6.4 L (18.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender |
Tender Value
₹45.8 L
EMD Value
₹91,600
Closing Date
14 Jan 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi, 682 004
PROVIDING OUTSOURCING SERVICES FOR OPERATION OF AC PLANTS AT INS VENDURUTHY AREA,INHS SANJIVANI AREA INCLUDING PREVENTIVE MAINTENANCE OF AIR COMPRESSORS, ROUTINE MAINTENANCE/FUNCTIONING OF CERTAIN PACKAGE AC PLANTS AND DUCTABLE AC PLANTS NAVAL BASE
2020_MES_406799_1
8756/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹91,600
Yes
18 Jun 2021
24 Dec 2020
16 Jan 2021
24 Dec 2020
14 Jan 2021
31 Dec 2020
24 Dec 2020 - 30 Dec 2020
Amount
Providing services of One AC mechanic per shift for central/package type AC Plants from 0600 hours to next day 0600 hours in three shifts per day and night (i.e 8 hours per shift) including Sundays and holidays as per users requirement during summer/monsoon/winter and maintain the inside temperature and RH as per design and/or the requirement of users (where air conditioning have been provided) including carrying out of daily check up and cleaning complete all as specified and as directed by the EIC for the following plants installed at locations shown:- At New AC plant Sanjivani (Screw Chiller ) (i) 285x 2 = 570 TR capacity (In operation) (ii) 285x 1 = 285 TR capacity (As Stand by)
Ditto All as per Serial Item No 1 but location At ICU Sanjivani (Package Type): (i) 5.5X2 =11 TR capacity (In operation) (ii) 5.5X1=5.5 TR capacity (As Stand by)
All as per item No 1.00 here in above but operation in two shifts per day and night (i.e 8 hours per shift) as per user's requirement for the plant installed At Sagarika (including Sundays and Holidays) (i) 40X2 =80 TR capacity (In operation)
All as per item No 1.00 here in above but operation in two shifts per day and night (i.e 8 hours per shift) as per user's requirement for the plant installed At MWC & Kalam Auditorium (excluding Sundays and Holidays) (i) 10 X2 =20 TR capacity (In operation at Kalam Auditorium) (ii) 26X2=52TR capacity (In Operation at MWC) (iii) 26X1=26 TR capacity (As stand by at MWC)
All as per item No 1.00 here in above but operation in one shift per day (i.e 8 hours per shift) as per user's requirement for the plant installed locations shown:- (a) At SH 12 & DPC MO(K)(3 Plants) (excluding Sundays and Holidays) (i) 30X2 =60 TR capacity (In operation at SH 12 MO(K) (ii) 30X1=30 TR capacity (As Stand by at SH 12 MO(K) (iii) 8.75X2=17.5 TR capacity (In operation at DPC MO(K) (iv) 8.75X1=8.75 TR capacity (As stand by at DPC MO(K) (v) 8.75X2 =17.5 TR capacity (In operation ) SH 37 MO(K) (vi) 8.75X1=8.75 TR capacity (As standby) SH 37 MO(K)
All as per item No 1.00 here in above but operation in one shift per day (i.e 8 hours per shift) as per user's requirement for the plant installed locations shown At SH 14 & SH 28 MO(K)(2 Plants) (excluding Sundays and Holidays) (i) 40X2 =80 TR capacity (In operation at SH 14 MO(K) (ii) 8.75X2=17.5 TR capacity (In operation at SH 28 MO(K) (iii) 8.75X1=8.75 TR capacity (As stand by at SH 28 MO(K)
All as per item No 1.00 here in above but operation in one shift per day (i.e 8 hours per shift) as per user's requirement for the plant installed locations shown At ECHS Polyclinic (excluding Sundays and Holidays) (i) 26 X 2 =52 TR capacity (In operation )
Preventive Bi-Monthly maintenance of screw air compressor 600 CFM capacity ELGI 50 single stage Model EL06150 FAB No : 202432 with 110 HP motor, air and oil separator, cooling tower and connected items installed at PEGASUS NAY including the following all as directed and specified by Engineer in Charge for once in every 2 months( 60 days interval):- (a) Oil change (once in year) (b) Pressure switch setting, Tips condition checking (c) Blow down valve functioning and repair (d) Setting and checking of safety valves (e) Electrical current measurement in full & no load (f) Leakage test in joints (g) Oil leak checking (h) Oil filters check (j) Functioning and repair of control systems (k) Testing of condition of coupling element (l) Functioning and repair of mechanical valves (m) Checking and repair PLC/Gauges (n) Checking of separator or pre separator and repair (o) servicing of LT electric panel board of compressor. Note:- Major spares for replacement will be measured and paid separately under relevant items here in after but cost of labour for replacement shall be deemed included in quoted rate.
Supply only Tank gasket ST 1
Supply only Tank gasket ST 2
Supply only Bearing oil filter
Supply only Main oil filter element
Supply only Air filter element
Supply only Air Lube oil 20 L
Supply only Separator primary element and secondary
Supply and replacement of capacitor for package type of capacity 5.5 to 17.5TR as suitable for existing plant complete all as specified.
Supply and fixing in replacement of microprocessor control panels for AC plant as suitable and fitting for existing model of VLRP type range 6/5/4 Make: Soft hard or equivalent
Supply and fixing in replacement of microprocessor control panels for Package AC plant as suitable and fitting for existing model of VLRP type range Make: Voltas
M&L for Bi -Monthly servicing the ODU + IDU of Package type /Ductable AC of capacity up to 5.5 TR for AC condenser including cleaning of filter cleaning ,air blower cleaning ,condenser coil and fins clean with solvent material by using pressure water pump, servicing fan motor etc complete and all as specified and directed.
All as per Item No 19,But capacity of Package type /Ductable AC 7.5 TR to 8.75 TR, complete all as specified and directed by Engr-In-Charge.
All as per Item No 19, But capacity of Package type /Ductable AC 10.00 TR and Above capacity ,complete all as specified and directed by Engr-In-Charge.
Daily maintenance of cold storage freezer room (veg room)/medical store room of following capacities by maintaining 24 hours basis smooth functioning of the machine and upkeeping the plant datas in specified parameters by Engr-In-Charge as specified and directed. (i) 10000 BTUx 2 = 20000 BTU capacity (Freezer Room) (In operation) (ii) 10000 BTUx 1 = 10000 BTU capacity (Freezer Room) (As Stand by (iii) 10000 BTUx 1= 10000 BTU capacity (Veg Room) (In operation) (iv) 10000 BTUx 1 = 10000 BTU capacity (Veg Room) (As Stand by) (v) 24000 BTU x1 =24000 BTU Capacity (medical store)
Supply and replacing of liquid line dryer of capacity 5.5 TR-17.5 TR Make : CatchAll/Indfoss/Danfoss
M&L for replacement of motor bearing, pillow block bearing, blower shaft re-metalling, polishing and reassembling upto capacity of Air blower 6600 CFM
Supply and replacement scroll type sealed compressor of capacity upto 5.5 TR 3 phase 415V including removing the existing unserviceable compressor with alteration to existing connections including refrigerant charging of suitable refrigerant up to working pressure as required complete all as directed.
Supply and replacement of V belt A series suitable for existing Package AC plants/Central AC plants. Make: Fenner
Supply and replacement of V belt B series suitable for existing Package AC plants/Central AC plants. Make: Fenner
Supply and charging Refrigerant Gas R 22 in sealed cylinder including leak testing by using nitrogen gas all as specified and directed by Engineer in Charge. Note :- 1.Nitrogen will be measured and paid separately 2.Empty cylinder will returned to contractor after usage
Supply and replace fan blade for condenser motor suitable upto 1 HP 3 phase 415V motor all as specified and directed by Engineer in Charge.
M&L for dismantling of Package AC condenser motor three phase 415 V up to 1 HP taking out of bearing re-metaling the bearing housing, grinding, turning to the required size, cleaning of stator, including rewinding with same gauge copper insulated wire, varnishing, drying, re-assembling the motor to bring in original state including fixing on the foundation all as directed by Engr-in charge.
M&L for attending day to day complaints pertains to various package AC plant of any capacity up to 8.75 TR as and when required by Ref-Mech/Electrician and helper , with necessary T&P for checking the equipment at existing location, find out the faults to the equipments (including replacement of minor parts such as lugs,fuses,wires,nuts,bolts,washers,etc) complete and rectification of minor problems to make the plant functional in all respect all as directed by the Engr- in-Charge.
M&L for attending day to day complaints pertains to various package AC plant of any capacity 10.0 TR to 17.5 TR as and when required by Ref-Mech/Electrician and helper , with necessary T&P for checking the equipment at existing location, find out the faults to the equipments (including replacement of minor parts such as lugs,fuses,wires,nuts,bolts,washers,etc) complete and rectification of minor problems to make the plant functional in all respect all as directed by the Engr- in-Charge.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
N.O. Antony Contractors
AR Traders
AISWARYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .