Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹25.1 L+₹3.8 L (17.7%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹25.1 L+₹3.8 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
17 Sept 2020, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR/REPLACEMENT OF LT ELECTRIC SYSTEM AND EARTHING INFRASTRUCTURE IN TECH AREA AT AF STATION HALWARA
2020_MES_370320_1
GE/HAL-29/2020-21
Open Tender
Civil Works
Item Rate
365 days
GE (AF) Halwara
MES ENLIESTD CONTRACTORS CLASS D CAT b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹60,000
Yes
22 Sept 2020
19 Aug 2020
19 Sept 2020
19 Aug 2020
17 Sept 2020
3 Sept 2020
Amount
Taking up/down worn out/damaged/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/duct/pole/wall/pipes/roof tops etc. complete including taking out sand cushioning and brick protection etc all as specified and directed. Note:- Excavation and earth work shall be measured and paid separetely.
Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 300Sqmm 3.5 core complete all as specified and directed. Note : Epoxy cable Joints shall be measured and paid separately
All as per Srl item No 2.00 above but of 240 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 185 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 150 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 120 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 95 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 70 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 50 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 35 sqmm 3.5 core.
All as per Srl item No 2.00 above but of 25 sqmm 4 core.
All as per Srl item No 2.00 above but of 10 sqmm 2 core.
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out complete all as specified and directed. Notes : (i) Payment for excavation shall be made for one time in case the new cable is laid in the same trenches .
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
M&L Brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
Sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specified and directed. Note: 18 cm punned thickness shall be measured for payment purpose.
40mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
50mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
80mm bore GI tubing light grade as in cable protection pipe including all fittings as in replacement complete all as directed.
M&L boring under road/path/hard standing to pass the HT / LT UG cables upto 80mm dia pipe using mechanical arrangements complete all as specified and directed.
M&L heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 300 Sqmm 3.5 core aluminium complete all as specified and directed.
M&L heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 185 to 240 Sqmm 3.5 core aluminium complete all as specified and directed.
M&L heat shrinkable straight through joint for LT XLPE UG cables suitable for cable of size 70 to 150 Sqmm 3.5 core aluminium complete all as specified and directed.
M&L in replacement for feeder pillars box factory made-out door type made out of MS sheet (CRCA) of thickness not less than 3mm of size 75x75x45cm with aluminium bus bar strip 4 Nos of 600 Amps rated suitable for 1100 volt (LT) mounted on LT porcelain insulator front opening door two leaf braced with hinged,mounted on 4 Nos of angle iron 50x50x6mm duly welded with box and grouted in PCC block of size 30cmx30cmx30cm in concrete 1:2:4 type B-1 in foundation support, well finishing with cement mortar and comprising of the switchgear and accessories and Top of box MS sheet duly bent in/slope,tapper with projection of 30mm on all side,weather/vermin proof with high quality of rubber beeding on panel door,cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with two coats of smoke grey stove enameled paint over a primer coat including providing MCCB, 4 pole,fixed type 320Amps, 36 KA rating-01 No complete all as directed by Engr-In-Charge.
M&L in replacement for feeder pillars box factory made-out door type made out of MS sheet (CRCA) of thickness not less than 3mm of size 75x75x45cm with aluminium bus bar strip 4 Nos of 400 Amps rated suitable for 1100 volt (LT) mounted on LT porcelain insulator front opening door two leaf braced with hinged,mounted on 4 Nos of angle iron 50x50x6mm duly welded with box and grouted in PCC block of size 30cmx30cmx30cm in concrete 1:2:4 type B-1 in foundation support, well finishing with cement mortar and comprising of the switchgear and accessories and Top of box MS sheet duly bent in/slope,tapper with projection of 30mm on all side,weather/vermin proof with high quality of rubber beeding on panel door,cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with two coats of smoke grey stove enameled paint over a primer coat including providing MCCB, 4 pole,fixed type 250Amps, 36 KA rating-01 No complete all as directed by Engr-In-Charge.
M&L in replacement for feeder pillers box factory made-out door type made out of MS sheet (CRCA) of thickness not less than 3mm of size 75x75x45cm with aluminium bus bar strip 4 Nos of 320Amps rated suitable for 1100 vlt (LT) mounted on LT porcelain insulator front opening door two leaf braced with hinged, mounted on 4 Nos of angle iron 50x50x6mm duly welded with box and grouted in PCC block of size 30cmx30cmx30cm with PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate foundation support, well finishing with cement mortar and comprising of the following switch gear and accessories and Top of box MS sheet duly bent in/slope, tapper with projection of 30mm on all side, weather/vermin proof with high quality of rubber beeding on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side and painted with two coats of smoke grey stove enameled paint over a coat primer including providing MCCB, 4 pole, fixed type 200Amps, 25KA rating-01 No, including taking down existing feeder pillars any type complete all as directed by Engr-In-Charge.
Cleaning,scrapping,preparing the old painted steel surface of any description and applying two coats of synthetic enamel paint over one coat of red oxide primer to LT panel complete all as specified.
S&F in replacement MCB 63A TPN complete all as specified and directed.
S&F in replacement MCCB 63 A 4 pole 25KA with adjustable thermal & fixed magnetic setting lcs=100% of icu complete all as specified and directed.
S&F in replacement MCCB 100 A 4 pole 25KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 160 A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 200A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 250-A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 315A/320A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 400-A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
S&F in replacement MCCB 630-A 4 pole 36KA with adjustable Thermal & fixed magnetic setting lcs =100% of icu complete all as specified and directed.
M&L for checking of earth values of each earth pit on monthly basis/on periodcity/on demand/on any anomaly observed of any type of earth pit by deploying skilled and trained personnel with calibrated testing equipments and T&P required for the same and recording the actual earthing test results achieved at site, watering with adequate quantity of water to earth pits from nearest available water point to achieve better results complete all as specified and directed Note : Quartely/half yearly/yearly calibration report of the testing equipment shall be submitted by the contractor. Adequate teams shold be provided by contractor to carryout the jobs to complete with in desired perdicity.
Taking down serviceable GI earth strip of any size for replacement of wornout/unserviceable stud insulators and refixing including providing new porcealian/plastic insulators of suitable size with screws/nuts, bolts and washers and welding/brazing of joints/broken points etc complete all as specified.
Taking down serviceable aluminium earth strip of any size for replacement of wornout/unserviceable stud insulators and refixing including providing new porcealian/plastic insulators of suitable size with screws/nuts, bolts and washers and welding/brazing of joints/broken points etc complete all as specified.
Taking down serviceable copper earth strip of any size for replacement of wornout/unserviceable stud insulators and refixing including providing new porcealian/plastic insulators of suitable size with screws/nuts, bolts and washers and welding/brazing of joints/broken points etc complete all as specified
S&F in repair air termination, single pointed copper rod 12mm dia and 300mm long for lighting conductor complete all as directed.
S&F in repair aluminium strip 25x3.15mm with porcealian shaddles and fixing screws for roof conductors and down conductors and welding/brazing of joints above ground complete all as directed.
S&F in repair copper strip 20x3.15mm with porcealian shaddles and fixing screws for roof conductors and down conductors and welding/brazing of joints above ground complete all as directed.
S&F in repair copper strip 32x6mm with porcealian shaddles and fixing screws for roof conductors and down conductors and welding/brazing of joints above ground complete all as directed.
S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screws for lighting conductor complete all as specified.
S&F in repair galvanised iron strip 32x6mm with porcealian shaddles and fixing screws for roof conductors and screwed including 3 Nos, 8mm dia 25mm long hex head scews for lighting conductor complete all as specified.
M&L in repair earthing complete with galavanised steel plate electrode 600x600x6.3mm thick burried directly in ground vertically (earth plate to a depth of not less than2.25 meter deep below ground level) with the top edge of earth plate at a depth of not less than 1.5 meter below normal ground level connected to GI strip 32x6mm by means of bolts, nuts, washers of galvanised iron and provision of earth wire, galvanised iron protection pipe 40mm bore, light grade up to and including test point including necessary earth work in any type of soild and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, watering pipe 20mm dia galvanised iron light grade with funnel, RCC (1:2:4) type B1 precast cover 40mm thick with 6mm dia mild steel bars complete all as shown in electrical plate N.5 of SSR part-I connected to earthing test point all as specified or indicated,including taking down and testing on completion Note:- Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc,
M&L in repair earthing complete with copper plate electrode 600x600x3.15mm thick burried directly in ground vertically (earth plate to a depth of not less than2.25 meter deep below ground level) with the top edge of earth plate at a depth of not less than 1.5 meter below normal ground level connected to copper strip 20x3mm by means of bolts, nuts, washers of galvanised iron and provision of earth wire, galvanised iron protection pipe 40mm bore, light grade up to and including test point including necessary earth work in any type of soild and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, watering pipe 20mm dia galvanised iron light grade with funnel, RCC (1:2:4) type B1 precast cover 40mm thick with 6mm dia mild steel bars complete all as shown in electrical plate N.5 of SSR part-I connected to earthing test point all as specified or indicated,including taking down and testing on completion Note:- Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc,
Supply and installation, commissioning and testing in repair of tripode (set of three) copper bonded rod earthing 17mm dia and 3 metre length with copper strip of 20x3mm for interconnection to earth electrodes including brazing and for upto test point. the electrode should be copper coated with 250 micron. the copper bonded rod shall be surrounded with 50 Kg (25 Kgx2 bags) back fill compound to provide maximum contact between the electrode and backfill compound. Backfill compound should be eco freindly and having RDSO certification. Copper bonded rod earthing should be maintenance free.the earthing pit should be covered with FRP pit cover etc complete including taking down and testing on completion all as specified directed Make: JMV/ENNOV infra solution/power trac.
Supply and installation, commissioning and testing in repair of each set of four copper bonded rod earthing 17mm dia three metre length with copper strip of 20x3mm for interconnection to earth electrodes, including brazing etc and for upto test point .The electrode should be copper coated with 250 micron, the copper bonded rod shall be surrounded with 75Kg (25Kgx3 bags) back fill compound to provide maximum contact between the electrode & back fill compound. Back fill compound should be eco freindly and having RDSO certification. copper bonded earthing should be mainteance free. the earthing pit should be covered with FRP pit cover etc complete including taking down and testing on completion all as specified and directed Make : JMV/ENNOV infra solution/power trac.
Supply and installation, commissioning and testing in repair of each set of five copper bonded rod earthing 17mm dia three metre length with copper strip of 20x3mm for interconnection to earth electrodes, including brazing etc and for upto test point .The electrode should be copper coated with 250 micron, the copper bonded rod shall be surrounded with 100Kg (25Kgx4bags) back fill compound to provide maximum contact between the electrode. Back fill compound fill should be be eco freindly and having RDSO certification. copper bonded rod earthing should be mainteance free. the earthing pit should be covered with FRP pit cover etc complete including taking down and testing on completion all as specified and directed Make : JMV/ENNOV infra solution/power trac.
M& for surface dressing not exc 15cm deep of earth pit surrounding area upto 1.5 Mtr away on all sides and complete earth pit, funnel etc of earth pit chamber including by cutting and cleaning away grass, bushes, small plant, vegetable shrubs, bushes of under roots etc and depositing waste to nearby garbage bin complete all as specified and directed.
Dismantling the existing unserviceable earth pit and M&L for constructing earth pit chamber with 120mm thick walls in PCC 1:3:6 type C1 of size 300x300mm (internal size)x250mm deep with 150mm thick foundation of size 690x690mm using PCC 1:4:8 type D2, 15mm thick internal plaster, RCC (1:2:4) type B1 precast cover of size 540x540x40mm thick with 6mm dia 150mm C/C mild steel bars with lifting handles 02 Nos with 8mm dia MS bar complete including marking of earth pit details all as specified and directed.
M/S SANGA SINGH AND CO
CHOUDHARY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .