Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.4 CrAccepted-AOC | ₹2.4 Cr Quoted ₹3.1 Cr | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹3.1 Cr+₹3.0 L (1.00%)Rejected-AOC | ₹3.1 Cr+₹3.0 L (1.00%) | L-2 | Rejected-AOC Rejected |
| 3 | L-2₹3.3 Cr+₹29.0 L (9.52%)Rejected-AOC | ₹3.3 Cr+₹29.0 L (9.52%) | L-2 | Rejected-AOC Rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
8 Jul 2022, 4:00 pmClosed
Executive Engineer
JSD Rampur
Prov. LWSS to Bhadawali villages in gp Bhadawali Tehsil Rampur
2022_HPIPH_62383_1
EE-JSD-RMP-E-TEN/22-3929-79 DT. 01.7.22
Open Tender
Civil Works
Item Rate
365 days
Rampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
EE Rampur
₹2.7 L
Yes
18 Jan 2023
2 Jul 2022
8 Jul 2022
2 Jul 2022
8 Jul 2022
2 Jul 2022
Amount
Cutting in earth work in all classification of earth work such as pick work, jumper work, saturated soil, blasting soft/ hard rock or chiselling soft/ hard rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering where ever required, stacking the serviceable/ unserviceable materials/soil separately complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 mts.stacking the excavated soil not more than 3 metres clear from the edge of excavation & returning the stacked soil in 15 cm.layers,when required into plinths sides of foundations etc.conslidating each depositrd layer by ramming & watering & then disposing of all surplus excavated earth as directed within a lead of 20 metres complete in all respect as per entire satisfaction of Engineer in Charge.
Excavation in drains and channels .(for pipes & pits upto all depth) in earth work in all classification of earth work such as pick work, jumper work, saturated soil , blasting soft/hard rock or chiselling soft/ hard rock including wedging out of a rock where blasting is prohibited in all lifts including trimming and dressing of sides levelling of beds to correct grades including shoring, strutting, planking, timbering and dewatering where ever required, stacking the serviceable/unserviceable materials/soil separately and after laying and jointing of pipes, returning the usable soil in trenches in 15 CM layers including consolidation of each deposited layers by ramming and watering and then dispositng of all surplus excavated soil, useable materials as directed within all leads/lifts including restoration of metalled surfaces to its original condition and including cost of diversion for traffic night signals, fixing caution boards, crossing over trenches for access to houses fencing etc. complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 ( 1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect with in all leads & lifts and as per the direction & to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:3:6 (1Cement: 3Sand: 6Graded stone agg.40mm nominal size)& curing complete excluding cost of form work in foundation and plinth as per direction & to the entire satisfaction of the Engineer-in-Charge with in all leads and lifts .
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Foundation,footing,bases of columns and the like & mass concrete.
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Providing and laying cement concrete 1 : 1.5 :3(1 cement :1.5 sand :3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcemnt for reinforced concrete work complete in all respect with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge .
Foundation,footing,bases of columns and the like & mass concrete.
Walls (any thickness but not less than 0.10m thickness) attached pillaster, buttresses, plinth & string courses etc from top of foundaation level upto floor two level as per the direction & to the entire satisfaction of the Engineer-in-Charge.
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Providing and laying cement concrete 1 : 1 :2(1 cement :1 sand :2 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcemnt for reinforced concrete work complete in all respect with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge .
In suspended floor roofs ,landing and shelves and their support.balconies , beams,girders, bressumers and contilever up to floor two level with in all leads and lifts.
Arches upto 6.00 mts. Span
Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforced concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Foundation,footing,bases of columns and the like & mass concrete.
Flat surfaces such as soffits & suspended floors, roofs, landing and the like. Floor etc. upto 200mm in thickness.
Vertical surfaces such as walls ( any thickness ) partition and the like including attached pillasters buttresses, plinth and string courses and the like.
Side and Sofit of beams
Prov.form work of ordinary timber plankings so as to give a rough finish i/c centring, shuttering,strutting & propping etc. ht.of propping & centring below supporting floor to ceiling not exceeding 4 mts. & removal of the same for insitu-reinforced concrete & plain concrete work in :-
Arches beyond 6.00 mts.span
Providing in RCC work smooth finishing of the exposed surface with Cement mortar 1:3 (1 Cement : 3 Sand) & as per direction & to the entire satisfaction of the Engineer-in-Charge.
Providing mild steel / tor steel reinforcement for reinforced cement concrete work including bending, binding and placing in position complete upto floor two level complete in all leads and lifts and as per the direction and to the entire satisfaction of the Engineer-in-Charge. Tor Steel.
Providing & Placing in horozontal layers of filtering media duly graded, screened, washed & cleaned as specified by engineer-In-charge
Top Layer:- Fine sand (eff. Size 0.20 mm to 0.40 mm & uniformity coefficient 2.00 to 3.00
2nd layer:- Coarse sand 3 mm to 6 mm
Third layer:- Bazri 20 mm to 25 mm
Fourth Layer:- Bazri 6 mm to 20 mm
Bottom Layer:- Broken stone 50 mm
Providing & placing Ist class Bricks in two layers 20mm over X Drain complete in all respect with in all leads and lifts.
Square rubble masonary coursed with hard stone of approved quality in foundation and plinth including rackingout joints in: Cement Mortar 1:4(1cement : 4 sand) complete in all respect with in all leads and lifts.
Random rubble masonary /Polygonal rubble masonary (un-coursed /brought to courses) with hard stone of approved quality I/c levelling up at P.L. with cement conc. 1:6:12 in cement mortar 1:6 (1cement,6 sand) in foundation and plinth.) with in all leads and lifts complete in all respect.
Brick work using common burnt clay building bricks in superstructure above G.L. to 1st floor level in cement mortar 1:6 ( 1Cement, 6 Sand ) of 2nd class bricks complete in all respect with in all leads and lifts.
Half brick work using common burnt clay building bricks in superstructure above 1st floor level in cement mortar 1:4( 1Cement, 4 Sand ) of 2nd class bricks complete in all respect with in all leads and lifts.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 2nd. Class deodar wood.
Providing and /Fixing Pannelled & glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hings necessary screw 40 mm thick 2nd class deodar wood.
P/F wire gauge shutters using MS wire gause of IS gause designation 85 G for doors windows clerestory windows I/c bright finished black enameled iron hings with necessary screws 30 mm thick 2nd class deodar wood.
Pointing on brick work with cement mortar 1:3 ( 1 cement, 3 sand ) with in all leads and lifts complete in all respect.
Priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other forgien matter
Priming coat on steel work with ready mixed paint brushing to give even shade including cleaning all dirt dust and other foreign matters white paint.
6 mm thick cement plaster to ceiling in C.M.1:3 (1Cement,3 sand) with in all leads and lifts complete in all respect.
15 mm thick cement plaster on fair side of brick,stone masonary convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80 mm girth in cm 1:6 (1 cement:6 sand) complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
20 mm thick cement plaster in single coat on ceiling of RCC slab upto floor two level i/c arrises,internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth & finished even & smooth in C.M 1:3 complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Steel work welded in built up section , trusses and framed work including cutting,hoisting,fixing in postion and applying a priming coat of red lead paint.
In gratings framed guard bars,ladders, railling,brackets and similar work. & as per direction & to the entire satisfaction of the Engineer-in-Charge
Providing and fixing M.S. grills of required patterns in wooden frames of windows etc. with M.S. Flats, square or round bars with round headed bolts and nuts complete including carriage of material within all leads and lifts and as per direction of Engineer-in-charge. (Oranamental Grill)
Distempering (two coats) with dry distemper of approved brand and manufacture and of required shade on undecorated surface to given an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Painting two coats excluding priming coat on wood and wood based surfaces with ready mixed paint and brushing to give an even shade including cleaning of all dirt, dust and other foreign mattercomplete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
White washing with lime on un-decorated wall surfaces ( two coats ) to give an even shade including throughly brooming the surface to remove all,dirt,dust,mortar and other foreign matter scomplete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Finishing wall with oil bound washable distemper paint of approved brand and manufacture (Two coats ) brushing to give an even shade I/c cleaning of oil,dirt,dust and other foreign matters,sand papering and knotting etc.complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing white viterous china pedstal type water closet (europen type ) awith seat and lid 10 ltr low level white vitreous china flush cistern and CP flush bend with fittings & CI breaks 40 mm flush band including cutting & makig good in wall & floor wherever required complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing PVC water storage tank of ISI 12701 marked GI inlet and outlet conection 15 mm nominal bore ball valve and mosquito proof PVC covered with locking arrangements including holding height upto ground level & 1000 ltr net capacity complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing CP brass pillar taps with capson head 15 mm dia complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing viterous china wash basin with single hole for pillar tap with CI or MS brackkets painted with incuding cutting holes and making good the same but excluding fittinngs flat back 550x450 mm complete in all respect within all leads and lifts as per the direction of Engineer-in-Charge.
Providing 40X3 mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embedding in cement concrete block 30X10X15 cm. 1:3:6 ( 1 cement ,3 sand,6 graded stone aggregate 20 mm nominal size complete in all respect with all leads and lifts.
Providing /Fixing anodised aluminium sliding door bolts with nuts and screw complete
(300 mm x 16 mm)
Providing /Fixing anidised aluminium towers bolts barrel type with screw etc. complete
200mmx10mm
Providing /Fixing oxidised aluminium MS handle with screw complete
125 mm dia
Manufacturing , Supplying & fixing of SFRC Man hole cover of size 560 mm ( M.d) with Frame fixed in partion complete in all respect as per direction of Engineer-in-Charge.
Boulder filling behind retaining wall as per direction and to the entire satisfaction of Engineer -In-Charge.
Laying, jointing and testing in trenches to be levelled to grade galvanised mild steel pipe light grade of following nominal diameter including fittings complete in all respect to the entire satisfaction of the Engineer-in-Charge. ( Earth work in trenches to be measured and paid for separately).
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
50 mm nominal diameter.
65 mm nominal diameter.
80 mm nominal diameter.
100 mm nominal diameter.
Prov. laying, Jointing and testing & commissioning at site in trenches galvanised API Pipe bevelled ended IS / ISO : 3183-2007 grade 320x46confirming to IS / ISO : 3183-2007 with latest upto dates amedments having wall thicjness as metioned below and capable of withstanding required test pressures as prrescribed in BIS could , in random lengths of 5.5 to 6.5 mtr . The pipe ends shall be bevelled suitable for butt welding. I/C the cost of jointing the butt welding confirming to IS 816-1969 or latest as applicable and upto date amendments(leak proof) in three layers at site of work with welding rods of advani/ oerliken make / ISI marked ( welding rods 3 mm to 4mm )and all allied accessories whatever required for welding at site i/c special short pieces reducers , tale pieces , teas, bends and other special manufactured from parent pipes as applicable to the particulars reach and of approved specification as per site conditions and cutting of pipe wherever required as per site requirement i/c carraige in all leads and lifts and as directed by the Enginner in Charge . The laying of pipe shalll include all operation such as cutting , welding , jointing , providing and fixing of MS flanges , fabrication og bends , tease, velves etc. i/c lowering and laying in excavated to ensure required level i/c flushing , cleanng and hydraulic testing complete in all respect to the satisfaction of Engineer-In -Charge. The favricated bends shall have 3 or 4 cuts having its radious not less than 5 times of dia of pipes. The pipe shall have zinc coting inside and outside confirming to IS 4736-1986 or latest with upto date amendments and shall be engraved with API L 320 or X 46 . The laying shall confirming to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engeer -In-Charge( Earth work and cost of MS flanges after 100 mtr length shall be measurered and paid for saperately) i/c all leads and lifts and carriage of material at site and as per direction and to the entire satisfaction of the Engineer-In-Charge.
100 mm dia wall thickness 4.80 API X-46 or L-320
RD 00 to 1200 T-34 (4.80)= 1200 Rmt
Prov. laying, Jointing and testing in trenches having random lengths of 5-7 mtrs including cost of fabriccation of minimum 3 cut bends of required degree galvanised mild steel tubes ( Medium grade of approved make by JSV ( list attached) bevelled edge of following ) mentioned grade , diameter and wall thickness confirming ti IS 1239:2004 as specified below joined with circumferential butt welded joints by electric arc welding according to relevant BIS code 816-1969 with minium three layers of welds sa as to achieve the the minium effective throat thickness and strength of welds confirming to BIS 6392-1971 specification by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon ( Ador) -CITOJET/ Esab make confirming to BIS 6392-1970 at site of work complete in all respect including manual / mechanical handling of pipe in all lead and lifts including all short pieces bends , tees and other special etc made from parent tubes as applicable for the particular reach and approved specificatios as per site condition including flushing clearing and hydraulic testing complete to the best satisfaction of Engineer-In-Chief . The laying of pipes should confirm to BIS 5822 - 1970 with in all leads and lifts complete in all respect.
100 mm dia
Providing & fixing full way valve with wheel of following diameter complete within all leads and lifts.
15 mm nominal diameter.
20 mm nominal diameter.
25 mm nominal diameter.
32 mm nominal diameter.
40 mm nominal diameter.
65 mm nominal diameter.
Providing & welding of MS flange 100 mm dia (IS: 6392-1971) of various table . The welding of flanges with pipe should confirm to IS: 816-1965 with electerode as per IS : 814-1967 i/c required nos of bolts & nuts as per IS: 1369-1967 & 3 mm thick asbestos fibre jointing gasket confirming to IS 2712-1965 , the welding of flange should be done in two layers on both faces to make the joints air tight complete and to the entire satisfaction of the Engineer-in-Charge)
RD 00 to 600 T-34 (4.80)= 600 Rmt
RD 600 to 900 T-28 (4.80)= 300 Rmt
RD 900 to 1500 T-17 (4.80)= 600 Rmt
Providing & fixing CI Sluice valve of following diameter for Rising Main complete within all leads and lifts.
80 mm dia ASA-300
Supply errection, testing and commisioning of horizontal spindle,horizontal split, redial split Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring performing funnel & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ mild steel to BHEL /Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c all leads an lifts and lifts as per entire satifaction of Engineer- in- charge.
2 Nos. Pump set ( i.e 1 No. working simultaneously & 1 No. Pump stand by 2x100 HP Each = 200 HP
A) SITE CONDITIONS i) Location of site= Bhadawali ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 1205 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 8 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by the tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 30 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read woth 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = Sufficient to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps One will act as working & 1 No. stand by b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 7.81 LPS for each pump. ii). Total head in Mtrs. If total head is not known then following details be provided:- 531.60 mtr i)Static head /Discharde Head = 501 Mtr ii)Minimum depth of water= Positive suction iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 5100 Mtr iv). Dia of R/Main= 125mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)15% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tendered (manufacturers certificate to be appended.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection, overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/ make of cast steel double flanged sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS 1414 ( MSEW -80 mm dia).
Providing and fixing of Kirloskar/Leader/KSB/ make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 112 Kg/cm^2) as per BS-1414 ( MSERW pipe-125mm dia) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from Tranformer of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 2 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Non Returning Valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
100 mm dia
OJSVI VIJAY BHANDARI
KAILASH THAKUR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .