| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder and quoted reasonable rate | |
| 2 | L2₹7.9 L+₹47,647.25 (6.42%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹8.0 L+₹55,014 (7.42%)Rejected-Finance BABAPORE KHREW PAMPORE PULWAMA KASHMIR | PULWAMA | JAMMU AND KASHMIR | 191102 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹8.4 L+₹93,614 (12.6%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹8.9 L+₹1.5 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹10.7 L
EMD Value
₹21,360
Closing Date
7 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Kargil
GE Kargil, PIN - 908121. C/o 56 APO
GE-K-56-2023-24 SPL REPAIR TO BLDG NO T-33 (ATT LIVING) AT 56 MTN BDE CAMP DRASS UNDER GE KARGIL
2023_MES_627417_1
GE/K-56/2023-24
Open Tender
Civil Works
Item Rate
180 days
Drass
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹21,360
20 Jan 2024
8 Nov 2023
9 Dec 2023
8 Nov 2023
7 Dec 2023
23 Nov 2023
Amount
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed
Supply & fixing pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified
Supply & fixing pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified
Supply & fixing 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or crancked hook bolts and washers as in roofs, walls etc, with grade of zinc coating 275, complete all as specified and directed
All as per Srl item No. 4.00 here-in-before but except sheet
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubish of the premises
Demolition of Cement Concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and as directed
M&L PCC 1:2:4 type B0 (12.5mm graded aggregate) 25mm thick as in floor finished surfaces fair and even to receive tile all as specified and as directed
M&L Joint free Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed
Hacking out old broken glass panes (any thickness size quality or description ) from wooden frame fixed with oil putty or beads area not exc 0.5 Sqm each all as directed
Supply & fixing 4mm thick glass pan ordinary quality and glazing with oil putty in square not exc 0.5 sqm each pane.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets all as specified and as directed by Engr-in-Charge.
Dismantling timber scantling as in fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section complete all as specified and as directed b Engr-in-Charge
M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed
M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed
Supply & fixing 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed
Supply & fixing 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work as in ceiling complete all as specified and directed
M&L preparation of new or previously untreated surfaces of steel and applying two coat of Synthetic enamel paint over a coat of red oxide primer incl preparing new zink or galvanised surface by coating mordant solution on CGI/PGI Sheets.
M&L preparation of old surfaces of steel and applying two coat of synthetic enamel paint complete all as specified and as directed.
Taking down carefully copper or aluminium point wiring (light, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box with 3mm thick pre laminated hylum sheet/PVC box flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch.
All as per Srl item No 21.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board.
All as per Srl item No 21.00 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board.
Supply & fixing switch piano flush type 5 Amps, single pole one way.
Supply & fixing switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type.
Supply & fixing switch socket combination 2 in 1, 5 and 15 Amps flush type.
Supply and fixing LED 1x18/20 Watt, 220 V, AC decorative box type fitting with driver, holder including LED tube ligh having lumen out put100lm/wattt,CCT:6500K , PF>0.9, and connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply & fixing ceiling rose on PVC squre block surface bakelite 65X50mm, two to three terminals.
Supply & fixing sheet metal enclosure for DB's double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing and commissioning.
Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable all as specified and directed and as directed.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Factory made ISI marked un-reinforced precast cement concrete cable cover of PCC 1:1.5:3 type A-1, conforming to class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified.
Supply & fixing sub main wiring with two single core 6 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and 4 Sqmm as continous earthing drawing and including PVC casing and caping of suitable size with all acessories, complete all as specified.
M & L LT UG cable 2 core x 16 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any size at site all as specified and as directed. Notes: (a) Excavation earth work and sand cushioning brick protectionand connected work etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
Supply and fixing GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed.
Supply & fixing in replacement of LED Flood light fitting 70 watt 5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed .
Dismantling and M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by means of GI bolts, nuts, check nuts and washers, protected by 15mm bore GI light grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all around bottom and top , 20cm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50M, CI pit cover duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed. Note:- (i) Protection pipe and earthing strip upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item. (ii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge.
Note : Deduction for amount of Rs 21,653.00 as listed in Schedule 'A' Part - II ( Schedule of Credit) shall be made while awarding of contract.
M/S BHAT ENGINEERS
SAMEER CONSTRUCTIONS
M/S TRADE LINK
M/S JAMSHEED ALI CONSTRUCTIONS
KASHMIR FAIR DEAL SERVICES
M/S ALI MOHD AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .