| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.9 L+₹1.4 L (7.12%)Rejected-Finance | L2 | Rejected-Finance Rejected being |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
22 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
CA NO GE(N)AMB-76/2021-22 SPL REPAIR TO MAIN DB AND CONNECTED ITEMS OF JCOS/OR BLOCK OF CW LINES/ALBERT EKKA LINES IN SECTOR B UNDER GE (N) AMBALA CANTT
2022_MES_510372_1
GE(N)Amb-76/2021-22
Open Tender
Civil Works
Item Rate
GE(NORTH) AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹66,000
Yes
28 Mar 2022
25 Feb 2022
24 Mar 2022
25 Feb 2022
22 Mar 2022
10 Mar 2022
25 Feb 2022 - 9 Mar 2022
180 days
Amount
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade as in repair complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying well burnt bricks sub class-B old size laid flat to cover the cabel width equal to the lenght of cable and abutting each other for protection of cables complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI pipe of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts as in repair complete all as specified and as directed by Engineer-in-Charge
Supply and fix MCB SP 6-32 Amps, 240 volt,10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN), 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door with and including fixed type MCCB 63 Amp, 4 pole, 415 volts, 16 KA duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA, 'C' curve including removing old unserviceable MCB complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
Material & labour as in repair for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
V K Constructive Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .