Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.9 LAccepted-AOC COURT ROAD UTTARKASHI | L1 | Accepted-AOC Qualifed | |
| 2 | L2₹52.3 L+₹42,939.98 (0.83%)Rejected-Finance 2 FRIENDS ENCLAVE SHAH NAGAR DEHRADUN | L2 | Rejected-Finance not qualified | |
| 3 | L3₹53.1 L+₹1.3 L (2.45%)Rejected-Finance 518 4 SAINI COLONY ROORKEE | L3 | Rejected-Finance not qualified |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
12 Apr 2022, 5:00 pmClosed
SE
SE EDC Srinagar
CONSTRUCTION OF 16.75 KM 11 KV LINE FOR PROVISING NEW CONNECTION FOR SABDARKHAL-KADEKHAL PUMPING PAYJAL YOJNA IN PAURI GARHWAK UNDER EDSD DEVPRAYAG
2022_UPCL4_42507_1
Tender no. 37/EDC(s)/2021-22
Open Tender
Electrical Works
Piece-work
90 days
work
CONSTRUCTION OF 16.75 KM 11 KV LINE FOR PROVISING
NEW CONNECTION FOR SABDARKHAL-KADEKHAL
PUMPING PAYJAL YOJNA IN PAURI GARHWAK UNDER EDSD
DEVPRAYAG
3 documents required · 3 mandatory
₹2,360
Yes
SE EDC Srinagar Garhwal
₹89,000
Yes
21 Sept 2023
28 Mar 2022
13 Apr 2022
28 Mar 2022
12 Apr 2022
28 Mar 2022
Cartage of following Material from store center Srinagar to Road side of work by PVT vehicle distance 55 Km including Loading unloading at both ends
ST Pole SP-23
ST Pole SP-55 (Bottom Portion hot Dip Galvanized)
11 KV VCB FDR 400/200/5A 110 V AC
Small Line Material
PRMC 11 KV
Head Load cartage of following material from Road side of work to Side of work upto 2.5 Km
ST Pole SP-23
ST Pole SP-55 (Bottom Portion hot Dip Galvanized)
11 KV VCB FDR 400/200/5A 110 V AC
Small Line Material
PRMC 11 KV
Excavation of earth for pole of size 0.90x0.60x1/6 of pole length for erection of ople in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil.
Erection of following pole in proper level and alignment along with fixing of all accessories X-bracing & clamp as per Respo construction manual.
ST Pole SP-23 Single Pole
ST Pole SP-23 Double Pole
ST Pole SP-23 Triple Pole
ST Pole SP-55 Single Pole
ST Pole SP-55 Double Pole
ST Pole SP-55 Four Pole
Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 Block including cost of cement, sand and stone ballast & back filling of soil and boulders inpit and ramming and proper alignment and leveling.
Muffing of pole size 0.45x0.60cm radius with cc 1:3:6 (1 cement:3coars sand:6 graded stone 10 mm norminal size) block size 45cm height from ground level including cost of cement, stone and sand etc.
Excavation of earth for stay pit of size 0.60x0.60x1.20 mtr. In all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil.
Fixing, tightning and nuzzling of stay (11KV) with pole and stay rod on required tension.
Grouting of stay in size 0.60x0.60x0.30 mtr. In CC ratio 1:4:8 (1 cement:4 graded stone 20mm nominal size:8 coarse sand) block including cost of cementand stone ballast back filling of soil and boulders in pit and ramming and proper alignment and leveling.
Fabrication of MS channel angle iron after cutting in required size with drilling of hole upto good finish for top channel bracing and special type bracket etc as per Respo shedule and local approve drawing.
Stringing, Sagging of ACSR Rabbit & G.S. Earth wire 7/16 SWG for making 11 KV line including jumpering & binding complete.
Erection of earthing of supports
Mounting and fixing of lightning arrestor set (3 Nos.) on double pole structure including making of complete connection work by GI strip size 35x6 mm to earth pole.
Mounting and fixing of TPMO on double pole structure including making of complete connection work
Mounting and fixing of fuse set on double pole structure including making of complete connection work
Painting of poles with angle and channel and all steel part by one coat of red oxide primer and two coat of aluminium paint and two strip of fluorecent altimate red and white paint 30cm wide upto 1.5mtr from fround level
ST Pole SP-23 (Bottom Portion Hot Dip Galvanized)
ST Pole SP-55 (Bottom Portion hot Dip Galvanized)
Providing and fixing of danger board and number plate complete by providing clamp of MS Flat 50x6mm with nut & bolt danger board of MS Sheet 2mm thick 11"x7" (including cost of all material)
Lopping of tree branches & bushes along H.T./L.T Lines
Guarding of line over telephone/road/LT line crossing as per drawing with 6/8 Swg GI wire including fixing of guarding channel/angle as per Respo manual LT/11 KV/33 KV for 11 KV Line
Fixing of heat srinking of 11 KV cable jointing kit 3x70 sqmm(O/D Type)
Fixing of heat srinking of 11 KV cable jointing kit 3x70 sqmm(I/D Type)
Mounting and fixing of 11 KV VCB FDR including complete all connection to Busbar of FDR & Control wiring of AC and DC Supply.
Installation of 11 KV metering cubical in the metering room with grouting and making all connection
Chemical earthing of VCB & PRMC
Digging of trench of size 06x0.15x1.5mtr and laying of underground 11 KV XLPE cable with making of brick Housing and filling of sand including filling of earth with ramming & repairing of Road including cost of cement and stone blast
Fixing of GI Pipe
Laying of 11 KV Cable in Half circle Hume Pipe Dia 150mm including cost of Hume pipe in Depth 1.5 Mtr.
Provision for Electrical Inspection Fees
Construction of metering room (size 10x12x10 Cu.Ft.) including fitting of light & Exaust Fan.
UTTARANCHAL FORGINGS INDUSTRY
VIKAS ELECTRICALS AND CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .