Secretary Kannur Jilla Panchayat
District Panchayath Office,Kannur
GENERAL-Abhu Chathukutty Stadium under Dharmadam legislative -Providing Generator Set-General Electrical Work
2023_SKDP_605483_1
B6/3292/23
Open Tender
Electrical Works
Item Rate
120 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,535
Yes
₹17,405
Yes
9 Nov 2023
21 Sept 2023
2 Oct 2023
21 Sept 2023
30 Sept 2023
21 Sept 2023
Amount
Providing Generator Set
OD165538/2023-2024:Supply, Loading, Conveyance, unloading, and erection of 40 KVA DG Set with Acoustic enclosure as per CPCB norms and as detailed below. 1. Engine a. Make of engine - Kirloskar, Mahindra, Ashok lyleand, Cumins or equivalent make b. Type of Engine - Diesel Engine. c. No of Cylinders - As per manufactures standards. d. Method of cooling - Water cooled with radiator. e. Aspiration - Naturally Aspirated. f. Design - Suitable for generating set operation. g. Output - Suitable for generating set operation. 2. Standard accessories with Diesel Engine a. Fly wheel. b. Close Coupled. c. Air cleaner. d. Radiator with fan provided with fan guard. e. Fuel Pump. f. Mechanical /Electronic governor. g. Fuel filter. h. Lubricating oil filter. i. Residential type exhaust silencer. j. Battery Charger / Generator. 3. Engine Instrument Panel with the following items. a. Starting switch with key or button and Remote control b. Lubricating oil pressure gauge. c. Water temperature gauge. d. RPM Indicator with hour meter. e. Battery charging ammeter. 4. Safety Controls for Engine a. Battery control (trip) for low lubricating oil pressure. a. Battery control (trip) for high water temperature. 5. Brush less alternator a. Make - Kirloskar/ KEL/Stamford/Crompton/Integrated electric Ltd or equivalent make b. Type - Self exited and self regulated c. Capacity - 40 KVA / 32 KW @ 0.8PF d. System of Voltage - 3Phase, 415V, 4 Wire system. f. Speed - 1500 rpm. g. Frequency - 50Hz. h. Insulation - Class F/H The alternator should confirm to IS 4722/IS13365. Operation and service manual shall be provided 6. Fuel Tank Suitable size fitted (built in type) inside the acoustic enclosure 7. Battery Suitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required including battery charger. 8. Standard control panel a.125 A 4 Pole MCCB Set at 100 A b. 1No multi function meter suitable for display of current in 3 Phases, voltage in 3 Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh, KW etc. c. 1 No separate KWH meter d. Necessary measuring CTs of appropriate ratio and burden for the required meter. d. Instrument fuse/MCB - 2set f. Metallic DNB - 1No g. Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection
OD165544/2023-2024:AMF Panel-Totally enclosed sheet metal control panel suitable for the 40 KVA Diesel Generator with suitable related connection
OD165547/2023-2024:Charges for conducting load test
OD163641/2023-2024:Supply of High speed Speed Diesel for test run
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.5.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
90.12.7.27:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
OD165724/2023-2024:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required-2.50 cm, 4 cm or 5 cm height
OD165725/2023-2024:Supply and installation of ABC type fire extinguisher of 6 kg. Capacity complete with initial charges and installation brackets, with ISI mark IS:15222.
OD165726/2023-2024:Supply, Providing and fixing following capacity TP&N disconnector fuse switch unit with ISI marked HRC fuses in sheet steel enclosure making connections, etc. as required.63 Amp TP & N
OD165727/2023-2024:Supply and providing 2 mm thick & 1 m wide electrical grade chequered type insulation mat to withstand 3.3 KV dielectric strength conforming to IS 15652/06
OD165728/2023-2024:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD165730/2023-2024:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
OD165731/2023-2024:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required
90.6.4.10:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 10 Run
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.17.7.4:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia
Vinod Kumar M
Bidder Name
Sajju T
Vinod Kumar M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_902467.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .