Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45.6 L
EMD Value
₹91,220
Closing Date
4 Apr 2025, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
REPAIR MAINTENANCE OF HT LT XLPE CABLE, CABLE JOINT AND OTHER ALLIED WORKS IN JETTY AREA AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2025_MES_700488_1
8265/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
7 documents required · 7 mandatory
₹500
GE (I) DM, Visakhapatnam
₹91,220
Yes
21 Apr 2025
7 Mar 2025
7 Apr 2025
7 Mar 2025
4 Apr 2025
21 Mar 2025
Amount
Excavation in trenches not exc 1.5M wide and not exc 1.5M in depth and getting out in soft loose soil for cable work or from above cable duct all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed.
Removing of excavated material not exc 50M and depositing where directed at a level not exc 1.5M above the starting point all as specified and directed.
M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and directed.
Supply and laying well burnt bricks sub class 'B' laid breath wise along the length of cable in trench for underground cable protection complete all as specified and directed.
Supply and fix plates Fe-290(Gde E?165) (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
Taking out old unserviceable LT/HT UG cable of any size and any description including GI pipe of any dia and bricks for cable protection where ever appeared and all as directed. Note:-(i) Excavation and earth work shall bemeasured and paid separately. (ii) Serviceable cable obtained shall be stacked properly for re use.
M & L for XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed,grade cross sectional area 240 sqmm 3.5 core complete all as specified and directed.
All as per item No. 8.00 above, but for cable sizes 300 Sqmm 3.5 core
All as per item No. 8.00 above, but for cable sizes 400sqmm, 3.5 core.
All as per item No. 8.00 above, but for cable sizes 500sqmm, 3.5 core
Supply only cable joining kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm including dismantling / taking down unserviceable one all as specified and directed.
All as per item No. 12.00 above, but for cable of size 240sqmm .
All as per item No. 12.00 above, but for cable of size 300 sqmm .
All as per item No. 12.00 above, but for cable of size 400 sqmm to 500 sqmm.
M & L for boring/drilling by machines/manual horizontally under the road in any type of soil without cutting/disturbing the existing road and inserting GI pipe of any size for drawing the cable complete all as specified and as directed . Note :- GI pipe shall be measured and paid seperatally.
M & L for 100 mm bore GI pipe tubes light grade for cable protection supporting with all fixing accessories (clamp, nuts, bolt and washer etc ) complete all as specified and as directed
Dismantling taking out LT Cable from cable rack/floor at gallery of marine jetty for repair/replacement of wornout steel cable rack or for realingnment of cable and refixing the cables with proper staking with proper alignment of cable on repaired/existing rack and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3 core, 185 to 240 sqmm, 11000 volts grade all as specified and directed. Note :- (i) Each cable shall be measured separately. (ii) Steel cable rack shall be measured separately as supply and fix
All as per item No. 18.00 above, but for cable sizes 300 to 400 sqmm, 3 core.
M&L for finding of cable fault in LT UG cable 1100 volts grade cable inside trench (under soil / drain/PCC/road/trench ) by disconnecting both cable ends, using insulation tester, cable path/fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 185 sqmm to 500 sqmm, 3.5 core, 1100 volts grade or replacement of heat shrink indoor cable joint kit of size 185 sqmm to 500 sqmm, 3.5 core and reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts-bolts-washers complete with testing all as specified and directed . Note :- (a) Items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints / heat shrink sleeves and earth work shall be measured separately . (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate. (c) Contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate.
M & L for Earth continuity conductor GI strip of size 32 X 6 mm all as specified and directed.
M&L for painting to chequrered plates as per existing sizes and thickness of one coat red oxide primer and two coat of black bituminius paint complete all as specified and directed.
M&L for finding of cable fault in HT UG cable 11000 volts grade cable inside trench (under soil / drain/PCC/road/trench ) by disconnecting both cable ends, using insulation tester, cable path/fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 185 sqmm to 400 sqmm, 3 core, 11000 volts grade or replacement of heat shrink indoor cable joint kit of size 185 sqmm to 400 sqmm, 3 core and reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts-bolts-washers complete with testing all as specified and directed . Note :- (a) Items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints / heat shrink sleeves and earth work shall be measured separately . (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate. (c) Contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate.
M & L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 240 sqmm 3 core all as specified and directed.
All as per item No. 24.00 above, but for cable sizes 300sqmm 3 core
All as per item No. 24.00 above, but for cable sizes 400sqmm, 3 core
Supply only Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm incl dismantling / taking down unserviceable one all as specified and directed.
All as per item No. 27.00 above, (indoor termination) but for cable of size 240sqmm to 300 sqmm.
All as per item No. 27.00 above, (indoor termination) but for cable of size 400 sqmm .
Supply only Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm incl dismantling / taking down unserviceable one all as specified and directed.
All as per item No. 30.00 above, (straight through heat shrink type joint) but for cable of size 240sqmm to 400 sqmm.
SUPREET CONSTRUCTIONS (BID ID -3271397)
DHEERU BUILDERS (BID ID -3272648)
SAI SREENIVASA ENGINEERING (BID ID -3272435)
KIRON ENGINEERING CORPORATION (BID ID -3272180)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .