Bill of Quantities
I. No. Qty Items Unit Rate Per Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra
Breacker including stacking of servicable
materials and disposal of unservicable
materials with all lead and lift.Removal Of
Existing Building Foundation and Super
Structure If Any.
Demolition of Brick work and stone masonry
including stacking of serviceable materials
and disposal of unserviceable materials with
all lead and lift.(ii) In Cement Mortar.Removal
Of Existing Building Foundation and Super
Structure If Any.
Dismentaling of sheet roofing including
ridges, Hips, Valleys, Gutters etc. stacking of
c serviceable materials and disposal of
unserviceable materials with all lead and lift.
i 5 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including
d 2000 distempering and stacking the materials with 3.63 Kg.
all lead and lift.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
e 2 architraves, hold fasts and other attachment 185.85 Each
etc. complete and stacking them with in all
lead and lift. (i)Notexceeding 3 Sq.M. in area.
Removing & Scrapping of Old deteriorated
Plaster of any thickness from Masonary /
R.C.C. member including stacking of
serviceable material & disposal of un
serviceable from site of work with all lead &
Dismentaling any type tiled of stone floors
laid in mortar including stacking of
g 50 serviceable materilas and disposal of 47.25 Sq.M.
unserviceable materials with all lead and lift.
Excavation for foundation including sorting
out stacking of useful material & disposing of
2 excavated stuff upto 50 mt. lead. Loose &
Soft soil.Excexuted With Mechanical Effort
a 837 up to 1.5 mt. depth 115.92 Cu.M.
b 796 1.5 to 3.0 mt. depth. 128.52 Cu.M.
c 503 3.0 to 5.0 mt. depth 141.11 Cu.M.
Add extra for Disposing off the excavated
d 1000 stuff of above items for lead of (A) 50 m to 17.28 Cu.M.
Add extra for Disposing off the excavated
e 1000 stuff of above items for lead of (B) 100 m to 34.56 Cu.M.
Providing and installing cast in situ single
under reamed piles of specified diameter and
length below pile cap, excluding the cost of
Concrete, steel reinforcement but including
f the cost of boring with bentonite solution and
the length of the pile to be embedded in pile
cap etc. all complete. (Length of pile for
payment shall be measured upto to the
bottom of pile cap) :
i 10 400 mm dia. Piles 644.63 Rmt.
ii 10 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for providing
additional bulbs in under reamed piles, under
g specified diameter excluding the cost of
Concrete, steel reinforcement (only the nos.
of extra bulbs are to be paid).
t 1 400 mm dia. Piles 813.05 Each
ii 1 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete 1:5:10 (1
cement : 5 course sand : 10 hand broken
3a 1 aggregates 40 mm nominal size) and curing 2492.51 Cu.M.
complete, excluding cost of form work in
foundation & Plinth.
Provdg. & laying cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 hand broken
3b stone aggregates 40 mm nominal size) and
curing complete excluding cost of form work
225 (A) Foundation and plinth 2976.00 Cu.M.
Supplying of graded hand brocken stone size
3c 45 of 90 mm to 127 mm at site (Rubble or 983.93 Cu.M.
Labour charges for spreading the spouls
mm to 127 mm thick layer good earth filling
in voids correcting the grade & camber
comp. with rolling, watering, incl. preparing
thesurface by brushing for removing all loose
or dirts ect.comp.
Provdg. & laying cement concrete 1:4:8 (1
cement : 4 coarse sand : 8 hand broken
4 5 stone aggregates 40 mm nominal size) and 2653.67 Cu.M.
curing complete excluding cost of form work
in foundation& plinth.
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of foundations
5 1800 etc. in layers not exceeding 20 cm. in depth 129.10 Cu.M.
consolidation each deposited layer by
ramming and watering.
Conveyance charges of earth lime, murrum,
building rubbish, manure, garbage, sludge,
6 excavated rock, fly ash, aggregate of any
kind etc. comp.
a 50 Conveyance charges upto 1 km 320.20 Cmt
b 50 Conveyance charges upto 2 km 347.73 Cmt
c 50 Conveyance charges upto 5 km 408.41 Cmt
Extra For Lead on Above Item Above 5 km &
d 750 upto 6 km 9.26 Cmt
Extra For Lead on Above Item Above 6 km
e 750 & upto 7 km 9.26 Cmt
Extra For Lead on Above Item Above 7 km &
f 750 upto 8 km 9.26 Cmt
Extra For Lead on Above Item Above 8 km &
g 750 upto 9 km 9.26 Cmt
h 750 Extra For Lead on Above Item Above 9 km 9.26 Cmt
Filling in plinth with sand under floors
7a 10 including watering, ramming, consolidating, 455.63 Cu.M.
compacting and dressing etc. completed.
Filling in foundation and plinth with murrum
or selected soil in layers of 20 cm. thickness
7b 128 including watering, ramming and 286.20 Cmt
consolidating etc. Complete.
Brick work using common burnt clay building
bricks having crushing strength not less than
8 35 kg/Sq. cm. in cement mortar 1:6 (1
cement : 6 fine sand) conventional brick
a 61 (a) in foundation & Plinth 3981.21 Cu.M.
b 196 Super structure Upto Floor Two Level 4253.46 Cu.M.
c 208 Super structure Above Floor Two Level 4293.55 Cu.M.
I.Half brick masonry in common burnt clay
building bricks having crushing strength note
less than 35 Kg/Sq. Cm. in cement mortar
1:4 (1 cement : 4 coarse sand) using
conventional brick in Super structure upto
floor Four level
a 265 All Floor Level 646.70 Sq.M.
Providing and laying controlled cement
concrete of M-25 Grade and curing
complete, Excluding the cost of form work,
Scaffolding, cost of reinforcement for
reinforced concrete work For any Height up
to any FloorLevel.
a 47 Foundations,Raft,Footings,Mass concrete 4238.04 Cu.M.
b1 35 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket, Stair Case
c1 23 & Landing, Coping ,Slab, balcony, weather 4496.07 Cu.M.
shed, loft , any cantilever etc All Floor
d1 4 Columns,Pillars, posts and struts at All Floor 4593.91 Cu.M.
Providing and laying controlled cement
concrete of M-20 Grade and curing
complete, Excluding the cost of form work,
Scaffolding, cost of reinforcement for
reinforced concrete work For any Height up
to Floor Four Level.
a 3 Foundations,Raft,Footings,Mass concrete 3977.88 Cu.M.
Tie Beam , Lintel , Beam- Bracket , Coping
b1 53 ,landing, Slab, balcony, weather shed, loft , 4460.36 Cu.M.
any cantilever etc at All Floor
c1 3 Column at All Floor 4558.20 Cu.M.
d1 1 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready Mixed
M250 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site
of laying with all lead and lift, excluding the
cost of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete,
improve workability without impairing
strength and durability as per direction of the
Engineer - in charge. Without Fly Ash (Min
cement level as per latest IS 456 shall be
maintained) (Cement level 450 kg )
Providing and laying in position Ready Mixed
M200 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site
of laying with all lead and lift, excluding the
cost of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete,
improve workability without impairing
strength and durability as per direction of the
Engineer - in charge. Without Fly Ash (Min
cement level as per latest IS 456 shall be
maintained) (Cement level 400 kg )
Drilling suitable holes in reinforced or plain
cement concrete with power driven drill
machine to a minimum depth of 80mm upto
250mm in RCC beams, lintels, columns and
slabs to introduce steel bars for
sunshades/balconies including fixing the
steel bars in position using Hilti Chemical
HY200-R but excluding the cost of
reinforcement, all complete as per direction
of Engineer-In-Charge.
8 mm Dia in 80 mm Deep & 12 mm Dia
a 50 183.52 Each
10 mm Dia in 100 mm Deep & 14 mm Dia
c 350 12 mm Dia in 120 mm Deep & 16 mm Dia 343.80 Each
16 mm Dia in 160 mm Deep & 20 mm Dia
d 50 608.63 Each
20 mm Dia in 200 mm Deep & 25 mm Dia
25 mm Dia in 250 mm Deep & 32 mm Dia
f 5 1938.54 Each
Providing and laying controlled cement
concrete 1:2:4( 1cement : 2 coarse sand :
Graded stone aggregate 20 mm nominal size
) and curing complete, Excluding the cost of
form work and reinforcement for reinforced
concrete work in:
Foundations, footings, base of
a 1 columns,grade slab and mass concrete. 3923.53 Cu.M.
slab, landing shelves, Balconies, lintels,
b 1 beams, girders, and cantilever, up to aany 4012.47 Cu.M.
P/A Trimix with dewatering machine and
floater machine on constructed R.C.C. work
incl. cost of machine and labour etc. comp.
Making 15 mm Groove in R.C.C work on
road and filling it with poly sulfied selant and
finished it good incl. all labour charges etc.
comp. as directed
Providing and laying and fixing 25 mm thick
expansion joint by hydrocell semi rigid UV
e 26 resistance with high performance laminated 738.13 Sqmt
closed cell polythene foam joint filler in sheet
foam as directed, etc. complete.
Providing form work in ordinary timber
planking so as to give a rough finish
including centering, shuttering, strutting and
12 propping etc. height of propping and
centering below supporting floor to celling not
exceeding 4 M & removal of the same for in
situ reinforced or plain concrete work in
(A) Foundation, footings, bases of columns
a 350 etc. and mass concrete. 171.68 Smt
(B) Flat surface such as soffits of slabs,
b 1082 landing and the like 252.00 Smt
(C) Vertical surfaces such as walls (any
c 703 thickness) partitions. 229.95 Smt
(D) Columns, pillars, posts & struts.
d 948 (1) Square, rectangular, polygonal in plan 297.68 Smt
e 10 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam, haunchings
f 1578 cantilevers, girders, bressumers, Coping and 192.15 Smt
lintels not exceeding 1 M in depth.
(2) Sides and soffits of beam, haunchings
g 10 cantilevers, girders, bressumers and lintels 259.88 Smt
exceeding 1 M in depth.
(L) chullah hoops, weather sheds, chhajas,
h 73 carbels etc including edges. 155.78 Smt
(M) Staircase with-sloping or stepped soffits
i 120 incl. risers & strings excluding landing. 242.55 Smt
Extra for additional height of propping and
centering where the height of propping and
centering exceeds 4 .O M between
j 50 supporting floor to ceiling including 386.48 Smt
temporary brick or stone pillars for supporting
as required. (i)Height more than 4.0 M.and
Providing T.M.T Fe 500D bar reinforcement
for R.C.C. work including bending, binding
and placing in position complete up to any
a 89430 All Floor Level 75.46 Kg.
Providing and laying polished Kota stone
slab (Polished / River Finish, Green colour )
flooring over 20 mm. (average) thick base of
14 45 cement mortar 1:6 (1 cement : 6 coarse 982.83 Sq.M.
sand) or lime mortar 1:1.5 laid over and
joined with grey cement slurry including
rubbing and polishing complete.25 mm th.
Providing and laying polished Kota stone
slab 25 mm. thick in Platform ,Riser of Stair
Skirting, Tread , dado and pillars laid on
15 65 mm. thick cement mortar 1:3 (1 cement : 3 1176.03 Sq.M.
coarse sand) jointed with grey cement slurry
including rubbing and polishing and MAking
groove where it is Required etc. compl
Providing and laying white/Colur glazed tiles
6 mm thick in flooring treads of steps and
16 5 landing laid on a bed of 12 mm thick cement 908.17 Sq. M.
mortar 1:3 (1 cement : 3 coarse sand)
finished with flush pointing in white cement.
Providing and layingWhite / Colour glazed
tiles of size 600 mmx300mm x 8 mm /
mmx 450mm x 8 mm in skirting, risers of
steps, Floor and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse
sand) and jointed with white cement slurry.
Providing and laying marble stone slab
flooring over 20 mm. (Average) base of
cement mortar 1:6 (1 cement: 6 coarse sand)
18 2 or L.M. 1:1.5 laid and jointed with grey 2194.63 Sq. M.
cement slurry including rubbing and polishing
complete: (A) Marble slab 25 mm. thick.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in flooring treads of steps
and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse
sand) finishing with flush pointing in white
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in skrting risers of steps and
19b 1662 dedo on 10mm thick cement plaster 1:3 1130.15 Sq. M.
(1cement : 3-coarse sand) and jointed with
white cement slurry
Providing and laying Ceramics tiles 6 to
mm thick in flooring, treads of steps, landing
20 78 and dedo on 12 mm. thick cement plaster 1:3 960.47 Sq. M.
(1 cement : 3 coarse sand) and jointed with
white cement slurry.
Providing & Laying 18 mm thick Mirror polish
granite For flooring , counter , stair riser
tread , skirting , dedo , Jambs , Seating etc.
machine cut or chiselled on bed of cement
mortar 1:1 pointing with neat cement slurry
incl. moulding, Making grooves where it is
required etc. comp. as per instruction of
engineer in charge.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat on fair side of brick /
22a concrete walls for interior plastering upto any
Floor level and finished even and smooth in
i 1056 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat plastering on ceilings,
b Beam side and sofits of stairs upto any Floor
level and finished even and smooth in
i 1066 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken mesh
jali with nails & then application of 15 mm
c 184 plaster on R.C.C. & masonary joints as per 315.15 Sq.mt
dir. of engg. In charge.
Providing and mixing water proofing
materials in cement mortar in proportion
d 180 recommended by the manufacturer. etc. 48.77
comp. as per instruction of engineer in
Providing 20 mm th. Double coat Sand face /
Mala Cement Plaster on Walls upto any
Height Above Ground level consisting of
23a 1190 mm th. Backing coat of C.M. 1:3 ( 1 cement : 297.68 Sq.M.
3 Ssand ) & 8 mm th. Finishing coat of C.M.
1:1 ( 1 cement : 1 sand ) ets. Complete.
White / Color washing with lime on
undecorated wall surfaces (two coats) to give
24a 50 an even shade including thoroughly 12.29 Sq.M.
brooming the surface to remove all dirt, dust
mortar drops and other foreign matter.
Providing & Applying 3 mm thick External
Wall Rustic Type Texture as per Design &
Make as Approved by Consultants /
Engineer in Charge. Work Includes All
Necessary Scaffolding Work upto Any
Finishing walls with Acrylic Smooth exterior
paint of required shade :New work (Two or
24 c 1200 more coat applied @ 1.67 ltr/10 sqm over 174.97 Sq.M.
and including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE textured
homogeneous wall finishing system from
BAKELITE HYLAM LTD or equivalent make
consisting of a two component system of (25
kgs per Pack) made of 92% silica particles
coated with fade resistant pigments, 100%
acrylic polymer bonding agent (5kgs per
pack) with the applied thickness of the
coating being between 0.8mm-1.2mm to be
applied on acured, smooth level plaster
without keying, as per the
shades/combinations approved, as per the
manufacturer directions, for usages, tobe
applied by an approved applicator of the
manufacturer, as per the directions /
supervision of the engineers in charge, all
complete. Includes All Necessary Scaffolding
Work upto Any Height.
Painting the illustration circle of Diameter
inch with weather proof exterior emulsion
acrylic based paint as per defined shade
code by experienced applicator of standard
24e 9 drawing and design according to the 1742.25 No.
reference manual of Facade Branding for
Health & Wellness Centres of Ayushman
Bharat Scheme as per the direction of the
Engineer in Charge.
Wall Painting (two coats) with plastic
emulsion / Oil paint of approved brand and
manufacture and of shade required on
undecorated wall surfaces to give an even
shade, over and including a priming coat with
25a 2150 alkali resistance primer of approved brand 78.44 Sq.M.
and manufacture after thoroughly brushing
the surface free from mortar droppings, and
other foreign matter and also including
preparing the surface even and sand -
Extra over above item for every subsequent
b 2150 coat of of wall painting with plastic emulsion / 33.39 Sq.mt.
Oil paint of approved brand.
Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of approved
brand and manufacture on new wall surface
to give an even shade including thoroughly
brushing the surface free from mortar
dropping and other foreign matter and sand
papered smooth.
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
26 materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a
head of 1.5 mt. and hydraulic test as dire
incl. watering trenches, spreading , and
carting away of surplus earth within
mt.lead as dire. etc. comp.
a 40 23 cm dia. 344.64 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a
head of 1.5 mt. and hydraulic test as dire
incl. watering trenches, spreading , and
carting away of surplus earth within
mt.lead as dire. etc. comp.
b 12 15 cm dia 288.23 Rmt
c 10 10 cm dia. 211.05 Rmt
Constructing brick masonry chamber for
under ground C.I. Inspection chamber and
bends with bricks having croshing strength
not less than 35 Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Lightduty) 455mm x
mm intenal dimensions total weight of cover
with frame to be not less than 38 Kg. (Wt. of
cover 23Kg.) and Wt. of frame 15Kg.)
(R.C.C.top slab with 1:2:4 mix (1-cement:2-
coarse sand:4-graded stone aggregate
20mm size) foundation concrete 1:5:10
inside plaster 15 mm thick with cement
mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed
concrete etc. complete.(i) Inside dimensions
455 mm x 610 mm and up to 850 mm deep
Constructing Manhole with R.C.C. top slab in
1:2:4mix (1-cement: 2-coarse sand:4-graded
stone aggregate 20 mm nominal size)
foundation concrete 1:3:6 mix (1-cement:3-
coarse sand:6-Brick bats 40+50mm size)
inside plastering 15mm thick with Cement
Mortar 1:5 (1-Cement:5-coarse sand)
finished with a floating coat of neat cement
and making channels in cement concrete
1:2:4 mix (1-Cement:2 -Coarse sand:4-stone
aggregate 20 mm nominal size) finished
28 a 3 smooth complete including curing and festing 19139.07 No.
(i) Inside size 900mm x 1200mm and up to
1.5M. deep including C.I. cover with frame
size 560 mm diameter total weight of cover
and frame to be not less than 128kgs. (Wt. of
cover 64Kg. and Wt. of frame 64Kg.) (A)
With 230 mm thick walls of brick masonry
using brick having crushing strength not less
than 35Kg./Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2)B type depth up
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 340x280x470 mm sizes
respectively with standard flush pipe, Waster
29a 6 Pipe, Waste Coupling, PVc Connection and 3344.35 No.
G.I clamps complete, including painting of
fittings and brackets, cutting and making
good the walls and floors wherever required :
Cera Model No. S4020103 or Equivalent
Providing and Fixing of C.P. Brass BIB Cock
of 15 mm Dia of Jaquar make florentine
b 24 series model no. 5047n or equivalent make 1564.17 No.
with all necessary fittings. as approved by
Engineer - in - charge.,
Providing and fixing brass screw down Angle
stop tap.(A) 15mm dia. Of Jaquar make
c 24 florentine series modelno. 5053n or 1160.57 No.
equivalent make with all necessary fittings.
as approved by Engineer - in - charge.,
Providing and fixing C.P. brass shower rose
d 2 with 15mm or 20mm inlet Shower Arm.(A) 279.37 No.
100mm dia. Each
Provding and Fixing of autoclosing
pressmatic pillar cock / bib cock with all
necessary fittings of Polished Bright Chrome
e 20 Finish of Jaquar make model no. 031L65 or 3280.52 No.
equivalent make as approved by Engineer in
Charge. Rate including of cost of labour,
material etc. in complete manner.
Providing and Fixing of C.P. Brass Two Way
Bib Cock of 15 mm Dia of Jaquar make
f 10 model no. 041kn or equivalent make 1411.58 No.
approved make with all necessary fittings. as
approved by Engineer - in - charge.,
Providing and Fixing of C.P. Brass urinal
Valve Auto Closing System With Full Built in
Control Cock & Wall Flange of 15 mm Dia of
g 6 Jaquar make model no. 077 or equivalent 2568.08 No.
make approved make with all necessary
fittings. as approved by Engineer - in -
Providing and Fixing of C.P. Brass Pillar
Cock Auto Closing System with Elbow
Operated Extended Lever of 15 mm Dia of
h 6 Jaquar Make Model No,031 MED or 3723.48 No.
Equvalent Make with all necessary fittings.
as approved by Engineer - in - charge.,
Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water tight
30 10 C.I. cover with frame of 300 mm x 300 mm 1234.57 No.
size ( inside) with standard weight. sqare
mouth trap size 150 x100 mm P trap
Providing erecting and fixing double coated
ISI water tank of required capacity each with
31 2000 all necessary fittings and connection etc. 3.91 Litre
complete on terrace
Extra rate over item of excavation of earth for
excavation of asphalt pavement/RCC of
thickness up to 0.20 meter including
32 20 demolishing the asphalt carpet, metal, soiling 71.43 Sq.M.
/ cutting Reinforcement etc.comp. with
stacking the material as directed.-up to
meter thickness
P/F PVC / C.I. (span) nahni trap and all of
the following nominal dia of self cleanising
design with C.I.Screw down or hinged
greeting inclusive cost of cutting and making
good the walls and floors for drain 75 mm
dia. etc. comp.
Provdg. And fixing to wall, ceiling & floor in
true line and level UPVC pipe Schedule-
of make as approved by engg. incharge.
pipe shall be fix on wall with the help of
clamp at every twi meter center to center of
shall be concealed as directed in cluding
neccesarry fitting etc. in cluding testing of
pipe and jointd and fixing the same with
adhesive solvent , including cost of all
materials of following nominal bore
i 80 15 mm 71.93 Rmt
ii 220 25 mm 90.93 Rmt
iii 10 32 mm 117.97 Rmt
iv 100 40 mm 146.65 Rmt
Providing and fixing concealed center point
to wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF)
34b seal for potable water of following dia.
nominal bore tube fittings and clamps
including making good the wall, ceiling and
floor etc. complete
i 5 15 mm 165.21 Rmt
ii 5 20 mm 202.97 Rmt
iii 10 25 mm 247.25 Rmt
iv 5 32 mm 330.36 Rmt
v 5 40 mm 437.66 Rmt
vi 5 50 mm 647.30 Rmt
Provdg. And fixing to wall ,ceiling and floor
10.00 kg. F/Sq.Cm2 working pressure
polythelene pipes of the following outside
35 diameter, low, density, complete with special
flange compression type fittings, wall clips
etc. making good wall ceiling and floor.
b 30 75mm dia 274.68 Rmt
c 90 110 mm dia 332.91 Rmt
Providing and fixing water closet squatting
Pan ( Indian type W.C. Pan) size 580mm
36 4 (A)VitreousChina. (I)Long pattern = White 1351.15 No.
colour with Trap and Pair of Foot Rest
Providing and fixing white vitreous china
extended wall mounting water closet of Cera
Make S1043101 Carat Model Or Equivalent
Model With EWC Soft Close Seat Cover,
Chair Bracket, nuts, bolts and gasket etc
Providing and Fixing of C.P. Brass Flush
Cock / Concealed Cock of 25 mm Dia of
Jaquar make model no. 081 or equivalent
b 14 and Outer Body of Jaquar make model no. 2732.58 No.
5083KPM or equivalent approved make with
all necessary fittings. as approved by
Engineer - in - charge.,
Providing and fixing Health Faucet of Jaquar
make model no. 573 oe equivalent make as
c 10 approved by engg. In charge with flexible 1543.36 No.
tube upto 1 metre long etc. complete.
Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single Bowl
38a 2 Sink S.S. Matt Finish With Waste Coupling, 7960.49 No.
Waste Pipe,etc. cutting and making good the
walls wherever required.
Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar tap,
32 mm C.P. Brass Waste of Standard make,
b 8 Cutting & Making good the wall / granite 6641.14 No.
Wherever Required in White Color : Model
S2030101 of Cera Clair Series or Equivalent
make Waash basine of size : 520x450 mm
Providing and fixing Wall Hung wash basin
Including 32 mm C.P. brass waste of
standard pattern, Include All Accessaries,
c 8 cutting and making good the walls / granite 3825.20 No.
wherever require:In White Color : Cera Cadal
Or Equivalent Make Wash basin of size
Providing and fixing Kitchen sink with C.I. or
M.S. brackets, painted white including cutting
d 2 holes in walls and making good the same but 2257.69 No.
excluding fittings. (C) Vitreous China Sink.(i)
600mm x 450mm x 150mm size
Providing and fixing C.P.brass waste for
e 2 wash basin or sink. (A) 32mm dia. 67.24 No.
Providing and fixing M.I. fisher union for
f 2 wash basin or sink. (A) 32mm dia. 77.97 No.
Provdg. & fixing 600mm x 450 mm Bevelled
edge mirror of superior glass mounted of .6
39a 8 mm th. A.C. sheet or plywood sheet and 825.48 No.
fixed to wooden pluge with C.P. brass
screws and washers.
Provdg. & fixing C.P..Brass towal rail
complete with C.P. brass brackets fixed to
wooden plugs with C.P. Brass screws.(600
mmx 20 mm size)
Providing and fixing ball valve (brass) of
41 approved quality, High or low pressure, with
plastic floats complete :
i 6 15 mm dia 886.22 No.
ii 1 20 mm dia 1099.94 No.
iii 10 25 mm dia 1552.93 No.
iv 1 40 mm dia 3312.60 No.
v 2 50 mm dia 4613.48 No.
Providing and fixing Full Way valve (HEX)
42a with wheel of approved quality :
i 2 15 mm Full Way valve (HEX) 1461.17 No.
ii 2 20 mm Full Way valve (HEX) 1924.61 No.
iii 10 25 mm Full Way valve (HEX) 2535.55 No.
iv 1 32 mm Full Way valve (HEX) 3377.64 No.
v 3 40 mm Full Way valve (HEX) 4661.10 No.
vi 2 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar Cock
of 15 mm Dia of Jaquar make model no.
43a 1 5011n or equivalent make with all necessary 1725.21 No.
fittings. as approved by Engineer - in -
Providing and Fixing of swan neck Sink Tap
Wall mount/Plateform Mount Jaquar make
b 3 model no. 5357n or equivalent make. Rate 2468.41 No.
shall Including of cost of labour, material,
necessary fittings etc.
Providing fixing of SS grab bar of Jaquar
make model no. 1507 or equivalent make
with all hardwares for Physically Handicap
Providing and laying integral cement based
water proofing treatment including
44a 250 preparation of surface as required for 1150.48 Sq.M.
treatment of roofs, balconies, terraces etc
consisting of following operations:
(a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with
water proofing compound conforming to IS.
2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls
upto 300 mm height including cleaning the
surface before treatment.
(b) Laying brick bats with mortar using
broken bricks/brick bats 25 mm to 115 mm
size with 50% of cement mortar 1:5 (1
cement : 5 coarse sand) admixed with water
proofing compound conforming to IS :
and approved by Engineer-in-charge over
mm thick layer of cement mortar of mix 1:5 (1
cement :5 coarse sand ) admixed with water
proofing compound conforming to IS :
and approved by Engineer-in-charge to
required slope and treating similarly the
adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a
second coat of cement slurry using 2.75 kg/
sqm of cement admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1 cement
:4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge
(e) The whole terrace so finished shall be
flooded with water for a minimum period of
two weeks for curing and for final test.“All
above operations to be done in order and as
directed and specified by the Engineer-in-
Charge :and shall be guaranteed for
minimum period of 10 years after handing
over the completed building by the main
contractor to be finished as directed. Stamp
paper guarantee 10 years to be furnished
before receiving any payment from the client.
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
b 250 tempered to bring mortar creme out upto 739.89 Sq. M.
surface using white cement including
rounding off junctions and extending them
upto 15 cm along the wall,clearing with water
and oxalic acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/
sqm. One coat of self-priming of elastomeric
waterproofing liquid (dilution with water in the
ratio of 3:1) and two coats of undiluted
elastomeric waterproofing liquid (dry film
thickness of complete application/system not
less than 500 microns). The operation shall
be carried out after scrapping and properly
cleaning the surface to remove loose
particles with wire brushes, complete in all
respect as per the direction of Engineer-in-
Filling in Sunken Portion with good Quality
Aerated light weight concrete block having
crushing strength not less than 35 kg/sqcm
and where directed by the Architect /
Engineer-in-charge, in sunk in layer.
including watering, ramming where it is
required etc. complete, as directed by the
Architect / Engineer-in-charge .
Providing and laying Cement concrete
flooring for I.P.S. 1:2:4 (for Indian Patent
Stones) (1 cement: 2 coarse sand: 4 graded
stone aggregate 20 mm. nominal size) lain in
layer finished with a floating coat of net
cement- 50 mm th etc. complete.
Providing & Fixing M.S.grill, gate,stair /
balcony railing , elevation element of
Decorative pattern with M.S. Channel ,flat
,medium grade m.s. pipe, square or round
bars with round heanded bolts, nuts, or by
screw. etc. comp.
Applying priming coat over new steel and
other metel surface after and including
preparing the surface by throughly cleaning,
b 170 oil, grease, dirt and other foreign matter and 34.34 Sqmt
scoured with brushes fine steel wood,
scrapers and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming coat)
on new steel and other metal surface with
enamel paint, brushing, interior to give an
c 170 even shade including cleaning the surface an 86.94 Sqmt
even shade including cleaning the surface of
all dirt, dust and other foreign matter.
Providing & Fixing 1.50 mm Thick S.S.-304
Grade 1150 mm High S.S. Railing having
Hand Rail Member of 50 mm Dia., 4 No. of
Horizontal Pipe of 16 mm Dia. & Baluster
Suppprt of 40 mm Dia. At Every Third Step
as per Detail Given. Rate Includes All Work
Complete as per Description & as per
Direction of Engg. in Charge.
Providing and fixing in position collapsible
steel shutters with vertical channels 20x10x2
mm braced with flat iron diagonals 20x5 mm
size with top & bottom rails of T-iron 40x40x6
mm with 38 mm dia. Steel pulleys complete
with bolts , nuts , locking arrangement
stoppers , handles including applying a
priming coat of red lead paint.
Providing corrugated 0.80 mm (22 gauge)
thick G.I. sheets roofing fixed with galvanized
iron ‘J’ or ‘L’ hook bolts, and nuts 8 mm. dia
b 5 with bitumen and G.I. limpet washers filled 719.93 Sq.M.
with white lead complete excluding the cost
of purlines, rafters and trusses.
Providing valleys 900 mm. overall in plain
mm. thick G.I. sheet Class – 3 fixed with ‘J’
c 3 or ‘L’ hook bolts and nuts galvanized from ‘J’ 1042.78 Sq.mt.
or ‘L’ hook bolts and bitumen washers
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their
entire length and jointed together at the ends
by end locks mounted on specially designed
48 9 pipe shaft with bracket plates, guide 4450.51 Sq.M.
channels and arragements for inside and
outside locking with push-pull operation
including the cost of hood cover and spring
etc. complete.(B) Shutters having width
Providing and fixing 27mm domal Series -
1.2 mm Th. Alluminium Section Two track
Sliding window With Metalic Powder Coating
49a 15 and 4 MM Clear Glaas(Non Tuffen) Include 4999.10 Sq. M.
All Accessaries and Fixture etc. complete as
per the direction of Engineer-in-charge.
Providing and fixing 27mm domal Series -
1.2 mm Th. Alluminium Section Three track
Sliding window With Metalic Powder Coating
49b 106 and 4 MM Clear Glaas(Non Tuffen) Include 6373.85 Sq. M.
All Accessaries and Fixture etc. complete as
per the direction of Engineer-in-charge.
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door work
(Single Shutter OR Double Shutter with fix
glass) made from Jindal or equivalent make
Powder Coated (50 micron pure polyester
coating ) ,aluminium section frame built up
standard tubular and other section of
approved make confirming to IS 733 and IS
1285 , member size with shutters of
horizontal member , vertical member
Confirming to IS733 and IS 1285 fixed with
rawl plug abd screws or fixing clips or with
expansion hold fasteners including
necessary filling up of gaps at junctions at
top bottom and sides with required PVC/
50 73 Neoprene felt, 8/12 mm toughened 5401.70 Sq. M.
Clear/Frosted glass of approved make etc.
Aluminum sections shall be smooth, rust
free, straight.mitred and jointed mechanically
wherever required including Door Hardware
such as cleat angles aluminum snap beading
for glazing /paneling, CP Brass/ Stainless
steel screws, Stoppers, heavy duty floor
hing, S.S. Hinges, aldrop , Locking system,
heavy duty Floor Springs, Pivot and fixtures
and transparent silicon sealant glass fixing to
frame as per details all complete as per
architectural drawings and the direction of
Engineer in Charge. rate incl. all type of
alumnium sections for doors as per the detail
Architectural dwg.
Providing and fixing standared extruded of
alluminium section of size 63 mm x
mm x 1.2mm (Section:2434, @
51a 8 Wt.0.643Kg/mt ) with colour anodized 1163.92 Sq. M.
alluminium frame for ventilation with 5 mm
thick frosted glass as details etc complete for
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
1.95 mm ( Section no: 4605, @Wt 1.094 Kg /
51b 5 Rmt with colour anodized alluminium frame 1509.90 Sq. M.
with 5 mm thick transparent bronze colour
tinted float glass as details etc complete for
Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
Having Size of Section of 2.1/2 x 1.1/2 with
4 mm Compact Sheet / 5 mm thick Glass
Fixing with 4 mm thick EPDM Rubber etc.
Complete as per Direction of Consultant /
Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
frame Having Size of Section of 2 .1/2 x
.1/2 and Door Section Having Size of Tips
Vertical 1 .3/4 x 1 .3/4, Top Rail 4 x 1 .3/4,
51d 17 Middle Rail 1 .3/4 x 1 .3/4, Bottom rail 4 x 1 4061.77 Sq.mtr.
.3/4 with 4 mm Compact Sheet / 5 mm thick
Glass Fixing with 4 mm thick EPDM Rubber
Including Lock, Handle, Door Closer, Door
Stoper, Stopper etc Complete as per
Direction of Consultant / Engg.incharge.
Providing and fixing ISI marked 32 mm thick
flush door shutters conforming to IS :
(Part I) decorative type, core of block board
construction with frame of 1st class hard
wood and well matched teak 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters with
mm thick Decorative Laminated Sheet on
both faces of shutters including ISI marked
Stainless Steel butt hinges, bright /matt
finished 125 mm Stainless Steel handles of
approved quality & make, ISI marked
oxidised M.S. door latches / Aldrop of Size
300x20x6 mm conforming to IS:5930 with
necessary screws etc. complete as per
direction of Engg. incharge.
a 27 Flush shutter with both side laminate 4332.15 Sq.M.
Providing wood work in frames of Doors,
windows cleare story windows and
b 43 othersimilar works wrought, framede and 602.04
fixed in position. (A) Indian Teak Wood
Providing and fixing 35 mm th. Shutters for
doors windows & clearstory windows incl.
wood frames as specified 12 cm. x 7cm.
53 size incl. anodised alluminium fixtures and
fastenings including primer coat of approved
quality and two coats of oil paint etc.
a 3 Fully glazed 4788.50 Sq. M.
b 3 Fully panelled 5478.89 Sq. M.
c 3 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and fixing FRP frame size 100x50
mm and 28mm thick FRP depress panel
shutter having extra reinforcement on sides
& edges in Gel coat finish. The core of the
shutter & frame is to be filed up with injected
fire retardant grade polyurethene foam done
in situ alongwith embedded wooden pieces
for stiffening & also taking hinges & fintures.
The whole FRP frame & shutter is to be
water proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be
inclusive of S.S hinges with necessary
screws & alluminium fixtures & fastenings &
fastener sleeve.
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be
well repaired as per instructions.
a 1 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild steel
distribution branch with galvanised mild steel
56 1 main pipe upto 80mm nominal bore by 600.08 No.
providing and fixing tee including cutting and
threading the pipes complete
Providing throating or plaster drip, grooves
57a 300 and moulding to Wall , R.C.C. chajja and 41.25 Rmt
Providing & Laying cement vatta 10 cm x
cm in size quarter round in c.m. 1:1 (
57b 75 cement, 1 coarse sand) laid in one layers 23.45 Rmt
finishing with a floating of neat cement
watering etc complete as dire.
Carring out plinth treat ment to post
construction/ existing structure by spraying
chemical solution for termite control
treatment including labour and material
consist ment withI.S.I specification. Using
Chlordene and Chiorpur files 20EC. As Per
58 250 6131_ paret- II Consentration Weight one 104.09 Sq.mt
percent is recommended i.e one litre 20EC
chemical emulsion with19 liter give1%
concrentration inclusive of one litre chemical
emulsion appication at the rate of 5 Litre
chemical/ Sqm of surface is recommended
Carring out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work
for termite control including labour and
material etc. complete. Using Chlordene
20EC. As Per 6113_part III Consentration
59 10 Weight 1.00 percent is recommended one 54.98 Smt
litre chemical emulsion dillute with 9 liter of
kerosene precent concentration. Total dillute
concrentration will be10litre inclusive of the
litre chemical emulsion application 0.75/Litre
chemical per one Sqmt printed two coat
Paver Block Providing and laying shot
blasted Non - interlocking, Paver blocks of
specified thickness, size, grade of concrete
and colour machine made and blasting by
automatic shot blasting machine and high
density of as per approved sample of
approved make for footpath, parking areas,
service lanes,cross over and other areas as
mentioned in the drawing. Including providing
and laying 50 mm thick averave bedding
layer of coarse sand below paver block as
per required grading and specification. Laid
paver block shall be mechanically
compacted. The work of the paving blocks
60 100 shall be executed in line and level by skilled 758.93 Sq.mt.
mason of flooring work only. Small size of
paver block with same specification shall be
used at residue or at end. It should be laid in
such a way that the no cutting of the paver
block to be necessary. If cutting of paver
block shall be required , than cut by machine
only and laying to be done by skilled flooring
mason. The finished surface of the paver
block shall have coarse sand Texture Finish.
Pave blocks shall be compacted and shall be
re-laid if necessary. Actual laid area shall be
measured and paid without any wastage. (A)
80 mm thick M-35 grade Grey Paver block of
size 200mm x 200mm. As per approved rate
SProviding and fixing pre-cast concrete kerb
stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of
61 120 M250 grade concret as per approved design 358.06 R.mt.
and including excavation for fixing in proper
line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate
with double spring mechanism and door
weight upto 125 kg, for doors, including cost
of cutting floors, embedding in floors as
required and making good the same
matching to the existing floor finishing and
cover plates with brass pivot and single piece
M.S. sheet outer box with slide plate etc.
complete as per the direction of Engineer-in-
charge. With stainless steel cover plate
minimum 1.25 mm thickness
Providing and fixing aluminium extruded
section body tubular type universal hydraulic
door closer (having brand logo with ISi, IS :
3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from
mm to 1200 mm), with double speed
adjustment with necessary accessories and
screws etc. complete.
Designing, fabricating, testing, installing and
fixing in position Curtain Wall with Aluminium
Composite Panel Cladding, with open
grooves for linear as well as curvilinear
portions of the building , for all heights and all
levels etc. including:
(a) Structural analysis & design and
preparation of shop drawings for pressure
equalisation or rain screen principle as
required, proper drainage of water to make it
watertight including checking of all the
structural and functional design.
(b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of
approved shades made out of 4mm thick
aluminium composite panel material
consisting of 3mm thick FR grade mineral
core sandwiched between two Aluminium
sheets (each 0.5mm thick). The aluminium
composite panel cladding sheet shall be coil
coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating
of approved colour andshade on face #
and polymer (Service) coating on face # 2 as
specified using stainless steel screws, nuts,
bolts, washers, cleats, weather silicone
sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy
6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the
wind load movement, fasteners, SS 316 Pins
and anchor bolts of approved make in SS
316, Nylon separators to prevent bi-metallic
contacts all complete required to perform as
per specification and drawing The item
includes cost of all material & labour
component, the cost of all mock ups at site,
cost of all samples of the individual
components for testing in an approved
laboratory, field tests on the assembled
working curtain wall with aluminium
composite panel cladding, cleaning and
protection of the curtain wall with aluminium
composite panel cladding till the handing
over of the building for occupation. Base
frame work cost for ACP cladding is included
in this item rate. The Contractor shall provide
curtain wall with aluminium composite panel
cladding, having all the performance
characteristics all complete , as per the
Architectural drawings, as per item
description, as specified, as per the
approved shop drawings and as directed by
the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on
the external face of the curtain wall with
Aluminum Composite Panel Cladding
(including width of groove) shall be
measured in sqm. up to two decimal places.
Providing and fixing Structural Glazing with
using the 17 Micron anodised of approved
colour alluminium section as transium,
mullium of size 63mm x 38mm x 2 mm with
using 6 mm thick reflective structural glass of
approved make, colour / Tinted, toughned
and shade and fixed with silicone sealant
and spacer tap and at corner sealed
neoprene foam dust and Air sealed gasket
mirred including scaffolding, cleaning of
glass etc.complete at all heights anf lifts with
all necessary fitting and fixtures, anchore
b 18 fasteners, necessary M.S. or Aluminium 3953.75 Sq.mt.
brackets, suitable design for openable or
sliding window as per Architectural drawing
and as directed by Engineer-in-charge.
Grooves between the glasses to be filled with
sealant of Dow corning - structural sealant
995, weather sealant 789. The entire facade
should be water proof. The mullions are to be
connected to bracket by SS-304 nut bolts.
Measurement shall be given as per actual
execution of the work. (Rate are included
providing & fixing of MS structure steel work
wherever Required)
Providing and Fixing Box type metal letters
forming composite box made from 1mm thick
stainless steel plate of grade 304 having
brush finish of following font size to be fixed
64 at Main Gate in english and or Gujrati and
including fixing charges. etc. complete as
per direction of Engg. incharge. for Payment
Purpose Height of Letter will be measured.
a 960 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out of
2mm thick s.s. plate grade 304, including
making necessary design as per Architect
dwg. Through laser cutting including
connection to the R.C.C./Masonary with
necessary frame,anchor fastnuts,M.S.Plate
etc. complete as per direction of Engg.
Providing and Fixing Sinage - internal and
external signage boards with Vinyle Text on
65b 3000 ACP sheet / 2 mm th. S.S. Plate etc. 9.38 Sq.Inch
complete as per direction of Engg. incharge.
Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board using
2mm Aluminum / 4mm ACP, angle iron 75 x
75 x 6mm. Descaling and degreasing the
board as per requirement using epoxy
reflactive process by screen painting as
directed etc. complete including transporting
and fixing in C.C. 1:2:4 with necessary
65c 7 excavation curing etc. complete as per I.R.C. 7535.31 Sq.mtr.
67-2012 design. A warranty for 7 years for
the Retro reflective sheeting from original
manufacturer & a certified copy of 3 year
outdoor exposure test report from third party
test lab for the product offered shall be
submitted by contractor. (B)Class B Type-
4(MDR/ODR) retro reflective sheeting
Road marking with hot applied thermoplastic
paints with reflectorising glass beads on
bitumin surface providing and laying a hot
applied thermoplastic compound 2.5 mm
thick including reflectorising glass beads @
250gms per sqm area, thickness of 2.5mm is
excluding of surface applied glass beds as
per IRC:35-2015. The finished surface to be
level, uniform and free from streaks and
holes. zebra patta /bump patta lane/center
65d 75 line/ edge line/cut patta. The white color 364.08 Sqmt
marking should provide liminance coefficinet
on cemend road shalll be min
mcd/m2/lux and Asphalt road shall be min
100 mcd/m2/lux during the service life during
the day time. The marking should meet the
performance criteria for night time reflectivity,
wet reflectivity and skid resistance as
mentioned in the section-15 of IRC
Warranty for the Retro reflectivity should be
CAT EYE/Pavement Marker(MNC two nail)
made out of acrylic StreneAcrylonitrile or hi-
impact poly Steren fitted with moulded of
metheacrylate(MNC)reflector cube corner
reflector design,filled with tightly adhering
pooting compound as per ASTMD-788 size
65e 5 11.5x7x1.60 cms or 10x10x1.75 cms 160.71 Nos.
provided with bituminous adhesive in
sufficient quantity with each unit fixing with
two shrank .Reflector on both side.Co
efficient of lumination as per specification
and compressive strenth 13 tones at
degree centigrade etc.B) Double side lenses.
Providing and fixing eco-friendly light weight
calcium silicate false ceiling tiles having T
egular edge & 15mm Thick Densified edges
on the Tile Periphery for Extra Strength The
Light weight calcium silicate ceiling tiles shall
have, light reflection 85% non-combustible
as per B.S.476 part IV, 100% humidity
resistance and also having thermal
conductivity 0.043° w/m KC. for the best
thermal Insulation.
The Light weight calcium Silicate tile shall be
of approved texture Fine fissured/ Spintone/
Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent
of size 595X595 mm to be laid on true
horizontal level suspended inter locking
metal grid of hot dipped galvanized steel
sections (galvanizing @ 120 grams per sqm
including bothside) consisting of main ‘T’
runner suitably spaced at joints to get
required length and size of 24X38 mm made
from 0.30 mm thick (minimum) sheet,
mm centre to centre, and cross ‘T’ of size
24X28 mm made out of 0.33 mm (Minimum)
sheet spaced 1200 mm along spaced
between main ‘T’ at 600 mm centre to centre
to form a grid of 1200X600mm and
secondary cross ’T’ of length 600mm and
size 24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at middle
of the 1200X600mm panel to form grid of
size 600X600mm resting on periphery walls /
partitions on a perimeter wall angle pre-
coated steel of size (24X24X3000mm made
of 0.40mm thick (minimum)
sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry wall
screws @ 230mm interval and laying 15mm
thick Densified edges light weight calcium
silicate ceiling tiles of approved texture (Fine
Fissured/ Cosmos/Spintone) in the grid
including, cutting /making opening for
services like diffusers, grills, light fittings,
fixtures, smoke detectors etc., wherever
required, Main ‘T’ runners to be suspended
from ceiling using G.I. slotted cleats of size
25X35X1.6mm fixed to ceiling with 12.5mm
dia and 50mm long dash fasteners, 4mm G.I.
adjustable rods with galvanized steel level
clips of size 85X30X0.8mm, spaced at
1200mm centre to centre long main ‘T’
bottom exposed with 24mm of all T-sections
shall be pre-painted with polyester baked
paint, for all heights,
, as per specifications, drawings and as
directed by engineer-incharge.Note:- Only
calcium silicate false ceiling area will be
measured from wall to wall. No deduction
shall be made for exposed frames/ opening
(cut outs) having area less than 0.30 sqm.
The calcium silicate ceiling tiles shall have
NRC. Value of 0.50 (Minimum) for Fine
fissured/ Spintone/ Cosmos and 0.75 NRC
for Globe, light reflection 85%
noncombustible as per B.S. 476 part IV,
100% humidity resistance and also having
thermal conductivity. 0.043° w/m KC.for the
best thermal Insulation
Providing and fixing single layer water proof
gypusm board 12.5 mm thick of the make
New good Group Co.Ltd. or equivalent &
New good Group Co.Ltd. company sections
using water proof board of size 1220 mm x
1830 mm x 8.0 mm suspended by G.I
suspender of size 25 mm x 3 mm with
intermediate channel of size 18mm x40mm
x0.80mm at 1220 mm center to center ceiling
section of size 40mmx 35mmx 0.55mm at
457 mm center to center and perimetre
chanel A of size 20mm x 27mm x 30mm x
0.50mm at edges & drops including paper
taps and sofit cleat, anchor fastener, scoch
bolt connecting cleat joining compound top
coat on ceiling including making necessary
opening for light fitting, diffuser etc. complete
as per detail drawing as directed.
Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet fixed
67a 10 with hilti screw and rubber silicon sealer and 1427.62 Sq.mt.
alluminium strip of size 50 x 3 mm etc
complete as directed by Engineer in charge
Providing Making & Fixing Glow sign Board
of suitable size as per approved color-
Designed Back Light Material fixed on G.I.
b 10 sheet Box of suitable size with concealed 2499.55 Sq.mt.
Light Fittings, Necessary Scaffolding etc.
complete as per direction of Officer in
Manufacturing,testing ,supplying
loading,,transporting to work site,loading
unloading lowering in trenches,laying and
jointing RCC NP3 class pipes in C:M 1:1
including all jointing materials such as
cement,sand,hemp bitumen as directed
testing the pipe line to a head of 1.5 mt and
hydraulic test as directed etc comp.
a 60 300 mm Diameter 616.07 Rmt
b 10 450 mm Diameter 806.25 Rmt
Constructing Bombay Pattern Type Catch Pit
of size 0.60 x 0.60 depth up to 1 mt including
excavation, B.B.C.C. (1:5:10), 23 cms thick
brick maso. wall in the prop. of CM (1:6) with
69 6 40 mm thick IPS flooring in the prop M15 at 3125.00 No
bottom and 15 mm thick cement plaster
inside the catch pit in the proportion of CM
(1:3) with out jali etc. comp. as directed.
CatchPit Jali Fixing P/F FRC catch pit jali
with frame 600mm x 600mm clear opening
etc. comp.. As directed by engineer in
PERCOLATION WELL
Drilling of pilot bore hole in Alluvial Strata by
71 120 direct Rotary Rig of 250 mm. 694.64 Rmt
72 120 Reaming 400 mm 212.50 Rmt
73 1 Electro Logging charges with carting 16071.43 Job
Providing and Installing 200 mm dia
74 60 IS:12818 upvc Casing Pipe "CM" class plain 1193.75 Rmt
Providing and Installing 200 mm dia
75 1 IS:12818 upvc End Cap, with Air Vent cowl 669.64 Set
200 mm dia Regular with 1.5 mm sloted size
cage type trapezoidal shape wire wound little
carbon galvanized screen confirming to
77 15 Supply of Pea sized Gravel 2029.46 Cmt
78 1 Air Vent of 50 mm Bend 401.79 Unit
Lowering and Removing of Dropline up to
79 120 Depth 186 mtr. 147.32 Rmt
80 1 Air Compressor 60 CFM/150 PSI 22205.36 Ls
I. No. Qty Items Unit Rate Per Amount
Electrical Work Estimate
1 INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type
switch / bell push & accessories and earth
continuity of following type, erected on PVC
/ Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as
(f) with medium class Rigid PVC pipe and
140 accessories erected concealed in 505.05 Pt
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of
.ISI marked 1.1 KV Grade ZHFR/HRFR
PVC insulated multi strand copper wires up
to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and
hum free EME four or more step type
1.2 electronic fan regulator with separately
mounted and accessories with earth
continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
65 accessories erected concealed in 701.40 Pt
wall/ceiling complete
Point wiring for secondary light point with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires, in below type of pipe to be
erected complete with earth continuity and
necessary connection with primary light with
accessories erected on Metal / PVC /
wooden box covered covered with
appropriate front plate modules erected on /
in wall / ceiling for open / concealed wiring.
with necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe
erected with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess
will be considered as Mains for Secondary
(f) with medium class Rigid PVC pipe and
90 accessories erected concealed in 174.30 Pt
wall/ceiling complete
Point wiring for Individual Plug with & earth
wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe
erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5
1.4.1 70 sq.mm Cu. Wire from nearby 530.25 Pt
switchboard/mcb db board
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
[II] For 16A Plug and 16 amp switch with 2-
1.4.2 30 2.5 sq.mm Cu. Wire from mcb db board. 774.90 Pt
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
[III] For 16A Plug and 16 amp switch with 2-
1.4.3 4 4 sq.mm Cu. Wire with 2.5 sq.mm ( green) 906.15 Pt
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
Point wiring for on board Looped Plug with
6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box,
1.5 85 single mounting base frame covered with 255.00 Pt
textured / metallic/white front plate modules
erected on / in wall / ceiling with following
type accessories
Point wiring for Two Way Controlled Light
Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked
KV grade ZHFR/HRFR PVC insulated multi
strand copper wires erected in below type of
pipe with 6A Modular type switches and
1.6 following type of accessories erected on PVC
/ Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
7 accessories erected concealed in 627.90 Pt
wall/ceiling complete
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
1.7 frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge.
1.7.2 24 (2) One No 5 pin plug 150.00 E.a.
1.7.3 40 (7) Blank Plate Single 25.00 E.a.
1.7.4 12 (8) Computer RJ-45 socket 159.00 E.a.
1.7.5 10 (9) 16 Amp. SP one way switch 179.00 E.a.
1.7.6 10 (10) 6/16Amp. Universal socket 198.00 E.a.
(13) 6A/10A/16A/20A/25A/32A Single pole
1.7.7 4 Modular MCB Switch 307.00 E.a.
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double
1.7.8 4 Pole Modular MCB Switch 406.00 E.a.
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.8 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
Providing & erecting PVC Corrugated
Flexible Conduit with required nos. of
1.9 coupling, PVC bushes, Check-nuts etc.
complete of following sizes.
providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non
PVC Zero Halogen free fire retardant
insulated copper conductor, insulated wire
(HRFR) conforms to IS-694, erected in
existing pipe with 1.5sq. mm copper
conductor of same specifications for earth
continuity of following size.
In Existing medium class Rigid PVC pipe and
providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
1.11 type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour
for earth continuity of following size
(A) with medium class Rigid PVC pipe and
1.11.1 25 (h) 4 wire 6 sq. mm 258.00 Mtr
(i) 4 wire 10 sq. mm
1.11.2 20 (use earth wire of 4 sq.mm ) 421.00 Mtr
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS
1.12 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel,
relays, power switchgears, motor starters &
control wiring) with required size of copper
lugs, nuts and bolts if required.
1.12.1 10 (e) One wire 6.00 sq. mm 56.00 Mtr
1.12.2 10 (f) One wire 10.00 sq. mm 91.00 Mtr
1.12.3 20 (g) One wire 16.00 sq. mm 141.00 Mtr
1.12.4 10 (h) One wire 25.00 sq. mm 234.00 Mtr
1.12.5 40 (i) One wire 35.00 sq. mm 298.00 Mtr
1.12.6 20 (j) One wire 50.00 sq. mm 466.00 Mtr
Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv grade
1.13 ISI marked copper wires of following size to
be erected as directed.
1.13.1 110 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
1.13.2 80 h) 2.50 Sq.mm 3 core round PVC sheathed 77.00 Mtr
1.13.3 20 k) 4.00Sq.mm 4 core round PVC sheathed 175.00 Mtr
Supplying & erecting M.S. Box having
Gauge painted with red oxide or Heavy duty
1.14 PVC box erected flushed on wall or
concealed in wall with necessary plastering &
finishing as directed of following size.
Supplying and laying UPVC cable trunking
system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and
1.15 flame proof confirming BS with necessary
end caps Internal and external bend, flat
bends, coupler, tee etc..All necessary
accessories and measuring of following sizes
1.15.1 5 (2) 100 mm x 50 mm trunking 424.00 Mtr
(4)100 mm x 50 mm trunking with TWIN
1.15.2 5 compartment With clip in divider 1309.00 Mtr
Supply & installation of surface mounted U
PVC snap-on adaptable trunking raceways,
fabricated out of U-PVC to Off-White or
approved shade as per IS 733 of thickness
2.0mm for the base and sides with all
accessories like removable covers, joints
,height spacer,angles complete with
necessary bends, suitable sized junction
boxes and tees etc, Complete.
(a)Size: 50x80mm PVC Raceways for Power
5 & Data with 2 compartments above 1052.00 Mtr
specifications.
Supply & installation of modular type
accessories for U PVC snap-on adaptable
1.17 trunking/Pop up Box with required items
erected with necessary connection. As
desired by Engineer In charge
1.17.1 1 i) 6 A SP 1 Way Switch 204.00 No
1.17.2 1 ii) 16A SP 1 Way Switch 351.00 No
1.17.3 1 iv) 6A universal socket shuttered 347.00 No
1.17.4 1 iv) 6/16 A universal socket shuttered 458.00 No
1.17.5 1 vi) Cat-6 LAN Socket 561.00 No
Supplying & erecting approved make
Telephone Cable electrolytic copper
conductor PE insulation twisted in two pairs,
& wrapped with FRLS PVC tape &
1.18 sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring &
confirming to C-DOT erected in existing pipe.
of following size of conductors & nos.of pairs.
With necessary connections.
(b) Armoured [Jelly Filled]
30 1) Ten Pairs 124.00 Mtr
1.19 LAN NETWORK
SITC of CAT6 UTP 24AWG PATCH
1.19.1 13 CORD:1M,Plug 30U' Snag less (Including 155.00 No
Five year free maintenance with guarantee)
SITC of CAT6 UTP 24AWG PATCH
1.19.2 13 CORD:2M,Plug 30U' Snag less (Including 199.00 No
Five year free maintenance with guarantee)
1.20. LAN SWITCH
SITC of 24 x 10/100/1000BASE-T ports 4 x
Gigabit RJ45/SFP Combo ports Advanced
L2 switching and security features L2+ Static
Routing Optional “standard mode” or
“surveillance mode” management user
SITC of Patch Panel UTP Keystone-
Port- Unloaded (Cat 5e,Cat 6 & Cat 6 A )
(Including Five year free maintenance with
Providing & erecting main Distribution (MDF)
1.21 indoor type, back mounted frame as per DoT
standard approved with krone strips
1 (a) Suitable for 10 pair 985.00 E.a.
Providing & Erecting Netwrok rack with
following capacity with Necessary cooling
1.22 fan,Cable manager,6A PDU,equipment rack
with necessary mounting accessories.
Supplying & erecting approved make LAN
1.23 cable of following size in existing pipe as per
SUB - TOTAL OF INTERNAL WIRING
2 Switchgears , Panels , MCBDBs & MCBs
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V.
having normal current rating 125A. with
2.1 Fixed thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
2 ICS=100% of ICU only 8773.60 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V.
having Normal current rating 200A.with
2.2 variable Thermal & magnetic release suitable
to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing
1 ICS=100% of ICU only 17667.10 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above
at 415 V . having normal current rating
2.3 250A. with variable thermal & magnetic
release suitable to work on A.C.supply
c/s. with all internal connections, spreader
tinned copper & complete erected in existing
16 G.M.S. housing.
1 ICS=100% of ICU only 22812.90 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 50 KA and above
at 415 V having Normal current rating 400A.
2.4 with variable Thermal & magnetic release
suitable to work on A.C.supply 50 c/s. With
all internal connections, spreader tinned
copper & complete erected in existing
G.M.S. housing.
1 ICS=100% of ICU only 27476.90 No
2.5 FABRICATION AND BUSBARS CHAMBER
Fabricating the box type items made from
M.S. Sheet with A.I. supports, wings, doors,
handles other hardware materials as per
requirement design with finishing by three
tank powder coating processed inside and
outside painted, erected as directed
including minor civil work. to install above
Providing and erecting busbar chamber
confirming to IS-375 fabricated from
G.M.S. sheet, dust & vermin proof having
hinged door with rubber gasket and
necessary busbar supports with COPPER
busbar having current density not more than
2.5.2 1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour
insulation tape for phase sequence, three
phase & neutral each suitable for following
current capacity with necessary painting
mounted on wall or pedestal frame of
required size with necessary connections.
1.5 (C) Suitable for 300 Amp. capacity 8455.00 RnMtr
providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of
2.5.3 moulded case circuit breaker having CT ratio
& MCCB rating as following along with shunt
trip 220V AC. with all internal connections &
complete erected in existing M.S.housing..
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type, wall / Floor mounted LT panel
suitable for 415 V 3 phase, 4 wire 50 Hz AC
supply system fabricated in compartmentised
design from CRCA sheet steel of 2 mm thick
for frame work ,Doors and partitions IP
and covers,3 mm thick for gland plates i/c
cleaning and finishing complete 9 tank
process in house facility for powder coating
in approved shade, extendable type FP
aluminium alloy busbars of high condectivity,
DMC/SMC busbar supports, entire panel
shall have a common copper earthbar of size
25mm X 5 mm at the rear with 2 Nos. earth
studs, solid connection from main busbar to
switchgears with require size of aluminium
busbar & control wiring with 1.5 sqmm FRLS
insulated copper conductor cable, cable
alleys, cable gland plates i/c accessrories as
per specification and providing switchgears,
metering instruments etc. for following
panel.G.A.Drawing to be approved by EIC or
consultant. ( Outgoing connectors must be
nut-bolt type. Outgoing mains for 63Amp
MCBs must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be
always from the busbars.
( a ) Providing cable clamps / supports
within distribution boards cable alley.
( b ) All hinged door shall be earthed through
2.5 sq mm tinned b raided copper wire.
( c ) Pad locking of MCCB’s handles in “OFF”
( d ) All the C.T.s should be auto short link
( e ) All the MCCB's should be with rotary
( f ) All incoming and outgoing air circuit
breakers shall be placed on middle portion of
the vertical in single tier formation.
( g ) Any descripancy found in SLD & Boq , it
should be brought in the notice of the client /
consultant, and the decision will be taken
final by Client / consultant.
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V.
having normal current rating 125A. with
2.6.1 Fixed thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
1 ICS=100% of ICU only 7976.00 No
providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of
2.6.2 moulded case circuit breaker having CT ratio
& MCCB rating as following along with shunt
trip 220V AC. with all internal connections &
complete erected in existing M.S.housing..
providing and erecting Miniature circuit
breaker single pole 0.5A to 2A system and
2.6.3 4 having breaking capacity 10 KA to be 268.00 No
erected in existing box. confirming to IS
8828/1996 with ISI Mark
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
2.6.5 having 10 KA breaking capacity & confirms
to IS : 8828 in existing box having following
Providing & erecting 415 V MCB Four Pole
for Motor & Inductive Load (C Curve) having
2.6.6 10KA breaking capacity & confirms to IS
:8828 in existing box having following
Providing & erecting 415 V MCB three Pole
for Motor & Inductive Load (C Curve) having
2.6.7 10KA breaking capacity & confirms to IS
:8828 in existing box having following
Providing and erecting following additional
2.6.8 parts for panel mounting MCCBs
(A)Extended operating rotary handle with
2.6.9 4 pad lock with three position trip,off,on 865.00
suitable for 25A to 250 A panel mounting
Supplying and erecting approved make panel
mounting type Digital Voltmeter having
digits LED display, 0 to 750 AC Volts range
erected on existing panel board with all
connection, wiring etc .with manufacturers
calibration certificate.
Supplying and erecting approved make panel
mounting type Digital Ammeter having
digits LED display, external CT operated,
2.6.11 1 calibrated for 0 to 1000 Amps suitable to 1543.00 No
operate on 500 Volt AC , erected on existing
panel board with all connection, wiring etc
.with manufacturers calibration certificate.
Supplying and erecting Ammeter / Voltmeter
selector switch for 3 phase AC Supply 500 V
on existing panel board with necessary
Providing & erecting L.T. Current
Transformer with bar primary 50/5 to 1000/5
2.6.13 3 ratio 15 VA burden erected in existing CRCA 272.00 No
box duly secured with insulating materials
connected to the meter
Supplying & erecting approved make Power
Factor Meter 150mm dia flush/projection
type/ balanced & unbalanced load to work
2.6.14 1 with appropriately provided CT’s 100/5A to 5052.00 No
400/5A ratio & other accessories complete
erected in M.S. box & connected to the
circuit by means of PVC copper Core leads.
Supplying and erecting approved make
suitable panel indicator LED type lamp, lens
cover, complete erected with necessary
Providing and erecting metallic vitrified
danger notice board as per language
2.6.16 4 suggested by engineer incharge for MEDIUM 69.00 No
VOLTAGE installation to be erected as per
Providing and erecting required size
Aluminium strip for earthing of H.T. , OCB /
2.6.17 2 ACB / Transformer, LT panel board, Motors 223.00 KG
etc. using copper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc.
using copper clamp.
Providing , erecting , fabricating the M.S.
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as per
direction of engineer in charge with
necessary grouting, cementing, plastering &
finishing complete.
Supplying and erecting triple pole & neutral
440V / 500V panel mounting Copper
Busbars with four equal Nos. of electrolyte
bus having current density not more than
Amp. / sq.mm (Rated current / cross section
2.6.20 area) duly wrapped with colour insulating
tape for phase sequence of following current
carrying capacity, erected with necessary
bus bar supports /insulators, main cable
socket to each bar, erected in existing
cubical panel with necessary connections.
3 (B) Suitable for 200 Amp. capacity 3171.00 RnMtr
Providing & erecting weather proof, dust &
vermin proof, floor mounted front operated
indoor type cubical panel board necessary
IP-42 and above protection as per approval
from engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body & doors,
2.6.21 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories
supporting angles/ flats channel including
cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per
requirements & instruction of engineer-in-
charge with erection of
supplied switch gears, BUSBARS, suitable
size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets,
rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with
locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears,
bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding base
beams) The panel shall be supplied with
following approved manufacturers with
following size.
(B) The standard companies switch gear
shall be used and only manufacturers at
CPRI approved factory
2 (i) with 350mm depth 14755.00 Sqmtr
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
2.6.22 unarmoured copper cable 1.1 KV grade to be
erected as directed of following size.
2.6.22a 16 (N) 4 core 16 Sq. mm 721.00 Mtr
2.6.22b 12 (M) 4 core 10 Sq. mm 568.00 Mtr
2.6.22c 2 (L) 4 core 6 Sq. mm 361.00 Mtr
2.6.22d 50 (C) 2 core 6 Sq. mm 202.00 Mtr
2.622e 4 (B) 2 core 4 sq.mm 130.00 Mtr
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS
2.6.23 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel,
relays, power switchgears, motor starters &
control wiring) with required size of copper
lugs, nuts and bolts if required.
2.6.23a 40 (a) One wire 1.00 sq. mm 12.00 Mtr
2.6.23 (b) One wire 1.50 sq. mm
2.6.23 (c) One wire 2.50 sq. mm
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type,15KVAR, Voltage Rating 415V
2.6.24 1 A.C.,3-Phase , APFC Panel having 5-steps ( 57615.00 No
2-3-5--5 kvar heavy duty can type capacitors
) with suitable rating of Incomer MCB, CT. as
per approved by engineer incharge.
Supplying & erecting approved make IP
grade Company fabricated Timer Panel of
following capacity for switch On-Off street
lights on time scheduling basis made from
16G CRCA sheet duly epoxy power painted
inside and outside with hinged doors and
2.6.25 locking arrangement consisting of suitable
size of 4 Pole MCB and 4 pole contactor
(cat-III)with analog time switch, auto manual
switch of same make and suitable input and
output Bakelite terminals and with door
earthing approved by Engineer in charge.
MCBDBs and MCBs
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
2.8 having 10 KA breaking capacity & confirms
to IS : 8828 in existing box having following
Providing & erecting 415 V MCB Four Pole
for Motor & Inductive Load (C Curve) having
2.9 10KA breaking capacity & confirms to IS
:8828 in existing box having following
Sheets steel powder coated enclosure
2.10. 2 suitable for incorporating One/Two nos. 175.00 E.a.
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
be used) suitable for
(A) single phase incoming and horizontal
single phase outgoing
(b) sheet steel double door (IP-43)
2.11.1 4 (i)4 way ( concealed manner ) 747.60 E.a.
2.11.3 2 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.11.5 7 (iv)12 way ( concealed manner ) 1773.60 E.a.
2.11.7 5 (v) 16 way ( concealed manner ) 1996.80 E.a.
(B) three phase incoming and single phase
2.12 horizontal type outgoing Per phase isolation
(b) sheet steel double door
2.12.1 2 (i)4 way ( concealed manner ) 2779.20 E.a.
2.12.3 2 (ii)6 way ( concealed manner ) 3462.00 E.a.
2.12.5 1 (iii)8 way ( concealed manner ) 4054.80 E.a.
Supplying & erecting Sheet Steel powder
coated Cable end termination Box to be
mounted on Top or Bottom of the MCB
Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of
(G) Three Phase 8 Way ( concealed
2.13.2 2 (G) Three Phase 8 Way 683.00 E.a.
providing and erecting Approved make
ELCBs / RCCBs conforming to IS:
and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and
2.14 suitable for operation on single phase
V,50Hz. having characteristic of quick action
& tripping with all advance feature & do not
incorporate any electronic component. for
following Max. rating erected as directed
Providing and erecting metallic vitrified
danger notice board as per language
2.15 16 suggested by engineer incharge for MEDIUM 69.00 E.a.
VOLTAGE installation to be erected as per
Providing & erecting Medium Voltage Danger
Notice Board sticker as per language
2.16 12 suggested by engineer incharge of standard 26.00 E.a.
size as per IS-2551
SUB - TOTAL OF Switchgears , Panel and
Follow IS code :3043 is the guideline for
Providing and erecting required size HOT
deep Galvanised iron strip for earthing of
3.1 150 H.T. , OCB/ ACB/ Transformer LT panel 77.00 KG
board, Motors etc. using proper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc.
using copper clamp.
Providing and erecting Annealed bare
3.3 10 Copper wire 8 to 16 SWG. 787.00 KG
Providing and erecting HOT deep
3.4 45 Galvanised iron strip wire 8 to 16 SWG. 77.00 KG
Supplying & erecting earth pit of minimum
bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising,
connection terminal dia of 12mm with
constant ohmic value surrounded by highly
conductive compound with high charge
3.5 dissipation suitable for following type of
applications with chamber and heavy duty
cover.(approved make OEM has to submit
test certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 W/ meter
testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to
retain moisture for long time Necessary test
report must be submitted.
(a) For Electrical Installation up to 440V in
3.5.1 4 Length of pipe - 1 Mtr 4546.00 E.a.
Back filling compound - 1 Nos Bag of 15 Kg.
(c) For Electrical Installation covering
Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer
3.5.2 1 System(like Automation, SCADA) i.e 8551.00 E.a.
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Supply, installation,testing and
commissioning of Chemical Earthing with UL
Certified 17.2mm Dia. X 3000mm Long
Micron-Copper bonded M.S. Rod
3.6 3 manufactured as per IEC 62561-2 with 25Kg 12230.00 No
Bentonite powder plus " U " bolt rod clamp
complete with Lockable high performence
chamber suitable & tested for 5000T
capacity with SS Hardware.or equivalent
SUB - TOTAL OF Earthing
CABLES, Cable Termination and cable
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
4.1 conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
of following size of cables
(A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2
(B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2
Providing and erecting XLPE (IS:7098)(I)-88
ISI armoured cable multistrand / Solid
4.2 Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
4.2.1 55 (a) 4 core 4 Sq. mm 116.00 Mtr
4.2.2 250 (b) 4 core 6 Sq. mm 125.00 Mtr
4.2.3 80 (c) 4 core 10 Sq. mm 139.00 Mtr
Providing and erecting XLPE (IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
4.3 conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
of following size of cables
4.3.1 80 (d) 4 core 16 Sq. mm 152.00 Mtr
4.3.2 15 (e) 4 core 25 Sq. mm 189.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe at road crossing or floor of following
4.4.1 40 (C) 3 core 6 Sq. mm 392.00 Mtr
4.4.2 25 (D) 3 core 10 Sq. mm 495.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand / Solid
Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing
trench / pipe at road crossing or floor of
following size of cables.
4.5.2 50 (B) 4 core 4 Sq. mm 361.00 Mtr
4.5.3 50 (C) 4 core 6 Sq. mm 505.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe at road crossing or floor of following
size of cables.
45 (C) 4 core 10 Sq. mm 670.00 Mtr
Making trench in soft soil of suitable width of
90 cm deep for laying cable or locating the
4.7 250 fault all over the run and back filling the 55.00 Mtr
same and making the surface as normal
Covering of cable with second class bricks or
cement tiles laid cover the cable crosswise
4.8 205 & also on both sides with covering of 7. 5 139.00 Mtr
Cm. layer of sand above & below cable (16
bricks per meter)
( A )Making trench in Hard Murrum / Tar
Road of suitable width of 90 cm or required
depth for laying any size of cable or locating
the fault all over the run and back filling the
same and making the surface as normal
(B) If additional machinery like hammer driller
4.10. 5 or JCB use [Add] 354.00 Mtr
Drilling the road without breaking the road
surface (Asphalt) for laying of cable for
4.11 feeding power supply by making up to
following size of holes at both ends
4.11.1 5 (A) Up to 100 mm bore dia 488.00 Mtr
4.11.2 5 (B) Up to 150 mm bore dia 610.00 Mtr
Supplying following size of Light duty “A”
4.12 Class G.I . Pipe & erecting as directed by
Engineer-in-charge.
5 (A) 25 mm dia 171.00 Mtr
Providing & laying. R.C.C. Hume pipe for
cable to be laid 90 cm. below ground across
4.13 the road crossing or on floor with necessary
material in an approved manner and making
the ground as per original.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
4.14 necessary connecting accessories of same
material at required depth in existing trench
for laying of cable. below ground / road
surface for enclosing cable
4.14.1 50 (A)50 mm outer dia 62.00 Mtr
4.14.2 250 (B)63mm outer dia 73.00 Mtr
4.14.3 10 (C))90 mm outer dia 95.00 Mtr
4.14.4 50 (D)120 mm outer dia. 136.00 Mtr
Providing & laying approved make ISI
marked Rigid PVC pipe having 6Kg / cm2
(Class-3) to be erected at road crossing on
or floor as directed for laying of cable. The
pipes as following size of dia & weight per
4.15.1 5 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124.00 Mtr
4.15.2 5 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234.00 Mtr
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
4.16 insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
Providing and, fixing heavy duty flange type
brass double compression type cable gland
4.17 with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating
tape etc for following size of cables.
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of
following size evenly crimped with high
4.18 pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made from
sheet steel. The cable tray should be single
or double bended as per required and as per
IS 2062/1079 and shall be coated with hot
4.20. dip galvanizing as per IS 2629/4759. with
max 17.5% perforation with coupler plate /
Fish plate and GI hardware like nut - bolt and
washers etc. erection with necessary
support( included) as per Specification and
as per instruction of engineer in charge..
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5 Light Fixtures & Fans
Supply , Installation, testing and
commissioning of pre-wired, LED fitting/post
top luminaries etc of all types, complete with
all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq.
mm FRLS PVC insulated, flexible, copper
conductor, single core cable with flexible
conduits and coupler and earthing etc. as
required. Note:- The LED Light fixtures
should comply all international standards
third party ( LM 79 for complete fixture, LM
80 for individual LED ). The Manufacturer /
Channel Partner of the Manufacturer has to
submit 4- Years unconditional free
Replacement Guarantee for complete fixture.
Supplying and erecting LED indoor fittings
with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V,
5.1 Power Factor more than 0.95, THD <
15%,CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt , LED driver
efficiency > 85 %( fitting required LM-79 &
LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may
select any wattage capacity between the
( A ) Tube Light with integral / non integral
(iii) 18-20 Watts, Surge - 2KV,IP-20,
5.1.1a 2 conventional 4 feet 293.00 No
(v) 36-40 Watts, Surge-2 KV, IP-20,
5.1.1b 15 conventional 4 feet 530.00 No
(B) LED Panel Light with provision for Plane
5.1.2 front frame with translucent cover fixed to
housing complete.IP20
5.1.2a 4 (i)up to 8 Watts,4" x 4", Surge-2 KV 271.00 No
5.1.2b 120 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462.00 No
5.1.2c 60 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607.00 No
5.1.2d 15 (vi) 36 watts, 24" x 24", Surge- 2KV 1777.00 No
5.1.3 (G) Spot Light 425 Lumens, Surge-2KV
5.1.3a 10 (a) 3 to 7 Watts 805.00 No
(H) Mirror Light 9 Watts, wall mounted
5.1.4 1 minimum 1 feet long 309.00 No
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt
A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with
canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by
Engineer in charge))
Providing & erecting Approved make Ceiling
Fan with double ball bearing ISI mark with
condenser A.C.230V 50c/s. 1400 mm. sweep
5.3 3 complete, canopy erected on existing hook 1721.00 No
or clamp with earthing [ Make shall be
approved by Engineer in Charge]
Providing & erecting Approved make Ceiling
Fan with double ball bearing with Condenser
230 volt A.C.50 Hz. 900 mm sweep complete
having 3 Aluminium blades, canopy erected
complete. [ Make shall be approved by
Engineer in Charge]
Supplying and erecting approved make
oscillating type medium duty bracket fan with
Aluminium Blades A.C. 23OV. 50cy/s wall
mounted with height adjustment and rotary
5.5 1 tilting device complete with guard, mounting 2329.00 No
accessories kit, pull cord for speed and
oscillation flexible Core plug top complete
erected with lead wires as directed. 400MM.
Supplying & erecting approved make low
noise decorative exhaust fan having size
5.6 22 200mm with 1350 RPM with square frame 1687.00 No
ABS body with inbuilt lowers & square frame.
Supplying & erecting fan hook box of
mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and
5.7 60 pierced through a 16 Gauge M.S. box / 107.00 No
Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
Providing 2.5mm.thick laminated acrylic
5.8 60 sheet to cover the fan hook or Fan box. 18.00 No
Supplying and erecting 19 / 20 mm. nominal
bore Medium Class M.S. Pipe down rod
5.9 60 erected duly painted for fan complete with 107.00 Mtr
proper insulation without leakage and
Supplying & erecting single phase approved
make industrial exhaust fan suitable for
medium duty ring mounted low noise
operation suitable for medium duty having
following dia size and maximum speed in
1 [D] 450 mm dia 900 RPM 3306.00 No
Providing suitable M.S. louver shutter of the
5.12 1 Exhaust fan. 365.00 No
Supplying & erecting electro galvanised G.I.
wire micro mesh jali cover of grade
5.13 1 required size with suitable wooden frame 628.00 Sqmtr
duly fitted in wall outside of exhaust fan for
insect protection.
Providing and erecting PVC body surface or
pendent mounting LED Bulk type 9 watt
Lighting Fitting with electronic driver. And
lumen output from luminaire 720lm , input
voltage range 90-300VAC , 50Hz cool
white(3000 to 6500k), inbuilt driver, -20degC
to +60degC working temperature, AL frame
with Beam Angle 120deg
SUB - TOTAL OF Light Fixtures & Fans
6 External lighting
Supply , Installation, testing and
commissioning of pre-wired, LED fitting /post
top luminaries etc of all typesof external
lights, complete with all accessories and tube
etc. directly on pole / pole bracket , including
connection with 1.5 / 2.5 sq. mm FRLS PVC
insulated,3 core flexible, copper conductor,
with flexible conduits and coupler and
earthing etc. as required.
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description
have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may
select any wattage capacity between the
(A) Street Light (IP-65), Surge protection -
4KV /5000K integral and 10 kv non integral
6.1.1 ,Light must have 440VAC line supply
protection. It should withstand 48 hours for
440VAC line supply.
10 (f) Above 60 watts to 90 watts 5917.00 No
(B) Flood Light (IP-65), Surge -4KV/5000K
,Light must have 440VAC line supply
protection. It should withstand 48 hours for
440VAC line supply
6.1.2a 2 (c) Above 60 watts to 90 watts 6028.00 No
6.1.2b 1 (v) above 120 to 160 watts 8370.00 No
Supply of approved make frp/grp pole having
followiing specifications :
FRP/GRP pole made by centrifugal moulding
process using thermoset resin
polyester/epoxy resin system having
minimum glass content 45.0%.The pole
should be in one pieceand tapered round in
shape,having smooth outside surface finish
and should be totally fre from corrosion as
well as non conductive and shock proof. Pole
should be provided with FRP/GRP base
bracket dully fabricated from metal(M.S) and
dully claded with FRP/GRP material to avoid
any metal exposer and painted with PU
paint.Pole should mechanical properties i.e
1. Specfic gravity (ASTM D 792) 1.3‐1.8
Kg/m3, 2. Glass Content % by weight (ASTM
D 2584) 45.0 ‐55.0%, 3. Water absorption
(ASTM D 570) <0.5%, 4. Tensile
Strength(ASTM D 638) 200+/‐50Mpa,
Flexural strength (ASTM D 790) 250+/‐
50Mpa, 6. Compressive Strength (ASTM D
695) 200+/‐50MPa, 7. Yeild Strength(ASTM
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance and
pigmented. Pole should be painted with first
coat of epoxy primer and then two coat of
highly weather resistance polyurethen paint
to ensure proper addhesion of the
paint.Minimum thickness shall be 80 to
micron.Defelection of the pole shall not
exceed more than 10.0 % of the length of the
pole for the given load.Pole should be
generally made as per the dimensional
data,performance criteria and some
interchagebility features of poles as per the
standard ANSI C123.20 latest version of
ASTM D 923/01 including cable termination
box with necessory accessories.The size of
pole and type of installation with foundation
Anchor Base & Internal junction box and
mounting ring fot flood light luminaires
installation as per the manufacturer details
and site requirement .
(3) 'B' class (Heavy Duty) frp/grp pole
suitable for base plate mounting
[D] Overall Length of 6.0 meter, Average
thickness : 7mm, Top/Bottom Outside Dia.
76/176mm +/‐2.Weight of Pole 25.0 Kg
8 approx. (Without base) Metal Anchor Base 16815.00 E.a.
dully frp claded (Size : 340 Ø * 12mmthk
Mounting hole PCD 285mm * 6 nos. of 20 Ø
Providing FRP/GRP arm bracket of having
6.3 15˚ arm with 50 mm OD pipe *5 mm
thk,1000mm long from pole centre
6.3.1 15 (a) Single arm bracket 1882.00 No
6.3.2 1 (b) Double arm bracket 2390.00 No
Supplying & erecting sintex make SMC
press moulded composite FRP. loop-in,
loop-out approx. 2mm thick box complete
with bakelite connector strip 4way & hinged
doors having locking arrangements with
mounting clamp with nuts, bolts & washers
suitable for erection on wall ( c)150mm x
125mm x 100mm [deep].
Providing cement concrete.for foundation or
for concrete filling in 1:2:4 ratio with 20 to
6.5 4 mm stone metal duly plastered with 5077.00 CU Mtr
necessary curing for pole muffing or any
B' class galvanised iron pipe 32 mm outside
dia 45 cms long duly welded on 20 cms x
cms x 3 mm thick M.S. base plate, erected
on wall or corner for mounting street light
luminaire with necessary hardware materials
SUB - TOTAL OF External Lighting
Supplying & erecting approved make
Automatic liquid level controller 6A. with
sensor testing as per instruction of Engineer
7.1 1 in charge on site complete with wiring 2332.00 Job
connection with existing wires , with copper
conductor from pump to upper and lower
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv grade
7.2 ISI marked copper wires of following size to
be erected as directed.
90 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
7.3 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed .
Providing & erecting water cooler having
storage capacity 150 Ltr. & cooling capacity
150 Ltr.per hour @ an ambient temp of 45˚
C. The outlet temp. of the water should drop
by 15˚C within a hour, The water cooler
should be comprising of hermetically sealed
compressor, fan motor, condensing unit,
water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with
necessary inlet & outlet connection. The
body of water cooler will be made from
Stainless Steel.
Supplying and erecting water filter cum
purifier with ultra violate technology.
7.5 3 (Aquaguard / waterdoc model or equivalent 5371.00 No
symphony/ crystal/videocon model)
Providing & erecting open well horizontal
mono block pump set with cast iron body,
complete for three phase submersible motor
[B] For 2 HP 3 phase open well horizontal
mono block pump set suitable for 200 LPM
@ 25 mtr head suitable for 50 mm dia
[C] For 3 HP 3 phase open well horizontal
mono block pump set suitable for 85 LPM to
270 LPM @ 11 mtr to 33 mtr head suitable
for 50/65 mm dia delivery pipe
Supplying & erecting approved make motor
control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder
painted inside and outside with hinged doors
and locking, arrangement consisting of
suitable size of ON- OFF isolator (AC -
3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B
7.7 phases, overload relay, Automatic water
level controller, Ammeter, Voltmeter each
with two way selector switch incoming, wires
duly socket crimped, main contactor &
overload relay, start - stop push buttons, to
be erected on angle iron frame grouted on
wall as directed. The isolator, overload relay
& contactors will be of L & T, Siemens or
2 (a) DOL up to 5.0 H.P. 7646.00 No
Charges for doing liasioning work for
obtaining the necessary clearances from the
Electrical inspector / competent Authorities
for the total Electrical installation,co-
ordinating with various agencies. All
necessary drawings, calculations, test
certificates, etc. as required by these
7.8 1 authorities shall be prepared and furnished 20500.00 No
by the EPC Vendor. Any
modification/rectification as required by these
authorities shall be carried out by theEPC
Vendor at free of cost. The fees required to
be paid to these authorities for inspection
shall be borne by Owner on production of
documentary evidences.
7.9 online Un-interruptible Power Supply system
Supplying and erecting approved make
online Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT
base rectifier & Inverter & sealed
maintenance free SMF batteries. The
charger having operating capacity for input
160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor
with battery, over/under voltage output with
over load & short circuit protection
equipment. The system housed in CRC
sheet duly powder coated paint with following
power backup.with MS painted batteries
stand, 10% Overload capacity for momentary
7.9.1 1 (C) 3 KVA with 1Hr Backup 82120.00 No
7.9.2 1 [E] 6 KVA with 1Hr Backup 177211.00 No
Providing and erecting approved make split
air-conditioning unit consisting of copper
condensing unit with fan motor, hermetically
sealed rotary compressor with accessories
etc. duly connected separately erected
evaporating unit and blower motor with its
7.10. accessories by means of extra supplied
proper insulated copper tubing,drain PVC
pipes suitable for ( cost includes powder
coated Stand, Eco Friendly green gas
charging, 15A plug top & Remote Control)
with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to
7.10.1 1 [a] For 1 Ton Capacity 30409.00 No
7.10.2 1 (b) for 1.5 ton capacity 36455.00 No
7.10.3 3 (c) for 2 ton capacity 45830.00 No
Supplying and installing MS angle , powder
coated / Painted standard type of wall/floor
7.11 stand mount for outdoor unit of split AC of
following capacity, erected with necessary
hardware materials as directed.
(A) 25mm*25mm*3mm thick M.S angle
5 suitable for upto 2 TR. Capacity of ac 1305.00 No
Supplying and erecting insulated pair of soft
copper tubing including power and control
7.12 60 cable,necessary PVC drain pipes for Split 956.00 RMT
AC machine up to 4 TR capacity
Rigid UPVC drain pipe of 10 Kg/cm2. rating
7.13 with 9 mm thick.nitrile rubber insulation.
SUB - TOTAL OF MISC. Work
8 PASSENGERS ELEVATOR
Supply ,installing , commissioning and
testing of M.R.L. Passengers Elevator 8/10
passengers as per R & B S.O.R ( Category -
Premium ) having following specifications:-
G+3 Upper Floor
Supplying, Erecting, Testing &
Commissioning the passenger lift having
following main features:
[1] GEAR LESS LIFT DRIVE comprising of
High Starting torque Lift 3 phase 440 V
A. C. Permanent Magnet Synchronous motor
of proper rating with high efficiency shall be
[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car
and door operation which shall be full
collective selective operation hall call
demand response, UP/DOWN hall stops,
Main, Up/ Down Contactor with overload
and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire
for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be
S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of
anti skid PVC with choice of colour of
engineer in charge. Car doors shall be of
stainless steel grade 304, hairline finish with
centre opening / telescopic automatic doors.
Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door
safety device, facility of auto/ attended mode.
All car panel buttons and all floor switches
must be with brail language as per lift act.
[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/
telescopic opening made of hairline finish
steel grade of 304 with key holes and
infrared curtains with Unlocking facility from
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan
should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position indicator
shall be provided inside the car and at all
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity
with Manual Rescue Operation ( Manual
Cranking Facility).
[9] Audio visual indication in the lift car
showing over loading shall be provided such
that doors kept open till excess load is
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational
and safety parameters shall be provided in
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the
lift machine room and monkey ladder for lift
pit should be provided by the lift agency,
along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator
in circuit for lift machine room and lift well
with proper numbers of light points, with
fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power
Supply shall be made available by
department in lift machine room. Necessary
Earthing as per Lift Act/Rules shall be
arranged by Lift Agency.
[18] Any civil/ electrical works for additional
and alteration in lift shaft and machine room
related to erection of lift shall be made by lift
agency without any extra cost.
(granite/marble fixing around all landing door
openings are not in lift agency’s scope.)
[19] Agency has to provide all working
drawings and documents and liaison
services for obtaining all necessary
permission from lift inspector and other
[20] acrylic transparent licence/display A4
size holder in lift car
[20A] As per statutory requirement of Govt.
Of Gujarat lift & escalator act 2000, lift
agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
authority 5.agency has to provide third
party insurance upto completion of free
maintenance period and submit the
document for the same.
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto
Glow type clearly visible when view from
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade
of 304 should be provided at appropriate
height on the Rear & Side Wall Panels in Lift
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP
Elcb required for lift is in scope of work which
rating is sugested by CEICED Department
(electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION
OF LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS
Serial Communication mode including
Regenerative power efficient operation,on
site programming facility, Anti nuisance, Pte-
opening, BMS/RMS with necessary online
real time monitoring system having
necessary connectivity for remote monitoring
& other suitable supporting hardware &
software devices to fulfil the purpose.
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and
hall lantern & TFT Screen in the car with
MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive
SS Moonrock finish / Hair Line / Honeycomb
for car and all Doors, All landing doors must
have fire rating up to 2 hours and car door
must have multi-level crisscross beam door
4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and
Each elevator are equipped with remote
monitoring system.agency has to provide
mobile app and user id and password for
AMC LOGO design as per given by
department to be embossed inside the lift
car wall opp. To door.
8 / 10 Passengers, Ground plus 3 upper
floor with Rated Speed of 1.0 m/sec.,
(C) With General PLUS ADDITIONAL
1 SPECIAL FEATURES attached herewith. 1560017.00 E.a.
SUB TOTAL of Passengers Elevator
9 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of ELECTRICAL +
HVAC System and passenger Elevator
For 1-Year DLP + ONE Year.
Annual comprehensive Type Maintenance
9.1 1 Charges only During Guarentee / Defect FREE Year
Liability period.
Annual comprehensive Type Maintenance
9.2 1 Charges for 1st Year after Guarentee / 113112.35 Year
Defect Liability period.
SUB-TOTAL Of ANNUAL Comprehensive
Maintenance contract Of Electrical
/HVACand passenger Elevator
I. No. Qty Items Unit Rate Per Amount
Final specification and block diagram
shall be submitted by CCTV camera
SITC of 1/2.8" CMOS 3MP IP Fixed Lens IR
rugged DOME Camera having progressive
scanning system , Pixels 3MP (2304 x
1296),Lens 2.8 mm, Fixed, F1.4, Minimum
Illumination color / BW: Color: 0.002 Lux @
F1.6, BW 0 Lux IR ON,IR Distance
Mtrs,Wide Dynamic Range 130 Db,Privacy
Masking Off/On (5 Areas),Local Storage
Micro SD/SDHC/SDXC card slot (2TB),Gain
Control 0 ~ 100%,Angle of View (H x V)
H:87.2° V:49.1°,Ethernet 10 Base-T/100
Base-TX Ethernet (RJ-45),Protocols:IPv4,
1.1 15 IPv6, TCP/IP, HTTP, HTTPS, 13222.00 No
RTSP/RTP/RTCP, IGMP/Multicast, SMTP,
SNMP, DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour), UDP,
ICMP, ARP, TLS, SFTP,Body Material
Aluminium + Polycarbonate,Number of Video
Streams 4,Ingress Protection IP66, IP67,
Event Notifi cation HTTPS, HTTP, SMTP,
ONVIF, Bit Rate 100 K ~ 6 Mbps Certificates:
FCC PART 15, CE (EN 55032), ICES-
003,CE (EN 55035),UL listed to UL/CSA
1,RoHS, REACH, WEEE,BIS ER, STQC
SITC of 1/2.8" CMOS 3MP IP Fixed Lens IR
rugged Bullet Camera having progressive
scanning system , Pixels 3MP (2304 x
1296),Lens 3.6 mm, Fixed, F1.4, Minimum
Illumination color / BW: Color: 0.002 Lux @
F1.6, BW 0 Lux IR ON,IR Distance
Mtrs,Wide Dynamic Range 130 Db,Privacy
Masking Off/On (5 Areas),Local Storage
Micro SD/SDHC/SDXC card slot (2TB),Gain
Control 0 ~ 100%,Angle of View (H x V)
H:87.2° V:49.1°,Ethernet 10 Base-T/100
Base-TX Ethernet (RJ-45),Protocols:IPv4,
IPv6, TCP/IP, HTTP, HTTPS,
RTSP/RTP/RTCP, IGMP/Multicast, SMTP,
SNMP, DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour), UDP,
ICMP, ARP, TLS, SFTP,Body Material
Aluminium + Polycarbonate,Number of Video
Streams 4,Ingress Protection IP66, IP67,
Event Notifi cation HTTPS, HTTP, SMTP,
ONVIF, Bit Rate 100 K ~ 6 Mbps,
Certificates: FCC PART 15, CE (EN 55032),
ICES-003,CE (EN 55035),UL listed to
UL/CSA 62368-1, BIS IS 13252 (Part 1)/IEC
69050-1,RoHS, REACH, WEEE,BIS ER,
Supply , Installation , Testing and
commissioning of 32 Channel NVR (Network
Video Recorder) Embedded Linux based for
recording upto 32CH at 1080P, 960fps with
04 nos. SATA HDDs minimum 40TB storage
or more (recording requirement all cameras
recording at 2MP, 25fps for 30 days), H.265
HEVC/H.264/MJPEG codec decoding, Front
Panel with LEDs Indication for Power &
HDDs Status, 3 nos. USB, ONVIF S, Time
Sync with NTP, Encrypted Streaming &
Control, 2-Way Audio Line & Out, PTZ
Operation Pan, Tilt, Zoom, Support, Pre &
Post Alarm Recording Support,
Recording/Evidence Clip Export to USB,
Channel Synchronous Playback, Playback
1.3 1 control i.e Play, Pause, Stop, Fast Forward, 66202.00 No
Backward, Speed Control, Timeline & Zoom;
Snapshot, Web Client, Central Monitoring
Software, iPhone; iPad; Android based
Mobile clients, 02HDMI & 01VGA Output,
On Board HDDS each up to 10TB, Alarm
Input (16 nos.), Alarm Output (04 nos.),
RS232/485, eSATA, 256 Mbps throughput,
NDAA Section 889 Compliant, Operating
Temperature –10°C to 55°C, Certification :
Certifications: ONVIF compliant, UL/CSA
62368-1, CE (EN 50130-4), FCC Part 15, EN
55032, NDAA & RoHS (EN63000) compliant.
Including fixing accessories and cable
termination with required connectors/Jack,
complete in all respect as per instruction of
engineer in-charge.
Supply Installation Testing & Commissioning
1.4 2 of 8TB Surveillance Harddisk 25150.00 No
Supply, Installation, Testing and
Commissioning of 43 inch, Professional LED
Display Cum Commercial TV with Android
& Inbuilt play store, UHD resolution, 400 nits
1.5 1 brightness, It's 24*7 usage, 50,000 hours life, 53465.00 No.
3 years warranty, Android 11 with inbuilt play
store, Inbuilt wifi, Landscape / Portrait mode,
Inbuilt Bluetooth, 2 GB / 16 GB Memory,
Inbuilt SOC with HDMI cable
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.6 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
CAT 6 UTP Cable
Supplying & erecting approved make LAN
1.7 cable of following size in existing pipe as per
Supply, Installation, Testing &
1.8.1 1 Commissioning of 9U wall mount rack. 12053.57 No
1.8.2 2 3U wall mount Rack 5025.01 No
SITC of 24 x 10/100/1000BASE-T PoE ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
1.9 1 L2+ Static Routing Optional “standard mode” 31680.00 No
or “surveillance mode” management user
interface 193 W PoE budget (Including Five
year free maintenance with guarantee)
SITC of 8 x 10/100/1000BASE-T PoE ports
x Gigabit SFP ports Advanced L2 switching
and security features L2+ Static Routing
Optional “standard mode” or surveillance
mode” management user interface 65W PoE
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supply, Installation Testing & Commissioning
5 Mtr. HDMI Interface Cable as per the
1.11 1 detailed Specifications supports transmission 820.00 No
of 4K Signals as per the detailed
Supply, installation, fixing, testing and
commissioning of PVC Junction box for
1.12 21 CCTV Camera, IP65, outdoor application. 440.00 No
Junction Box size will be as per vendor's
requirement and site condition.
SITC of Patch Panel Cat 6 UTP Keystone
1.13 1 Type- 24 Port-Fully Loaded (Including Five 4357.00 No
year free maintenance with guarantee)
SITC of Jack Cat 6 Keystone UTP (Including
1.14 22 Five year free maintenance with guarantee) 160.00 No
SITC of CAT6 UTP 24AWG PATCH
1.15 22 CORD:1M,Plug 30U' Snag less (Including 155.00 No
Five year free maintenance with guarantee)
SUB -TOTAL OF CCTV SYSTEM
2 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of CCTV System
For 1-Year DLP + ONE Year
Annual comprehensive Type Maintenance
2.1 1 Charges only During Guarentee / Defect FREE Year
Liability period.
Annual comprehensive Type Maintenance
2.2 1 Charges for 1st Year after Guarentee / 15776.76 Year
Defect Liability period.
SUB -TOTAL OF CCTV Comprehensive
Maintenance work
I. No. Qty Items Unit Rate Per Amount
FIRE FIGHTING SYSTEM
Design,Drawing, Supply,installing,testing
and commissioning of FIRE HYDRANT
Internal / External Hydrant
Supplying, Installation, Testing and
Commissioning of electric driven main
Hydrant fire pump and Sprinkler pump
suitable for automatic operation and
consisting of following: complete in all
respect as required.
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body & bronze
impeller with stainless steel shaft,
mechanical seal to ensure a minimum
pressure of 3.5 kg/sq. cm. at highest and
farthest outlet at specified flow of 2280 lpm
at 65 Mtr. head conforming to IS 1520.with
suitable size of footvalve confirming to IS
4038, Pressure rating PN2 , preventing entry
of foreign body to pump through suction pipe,
perfectly flat seating surfaces for good
b) Suitable HP Squirrel cage induction motor,
TEFC, suitable for opertion on 415 volts,
phase 50 Hz. AC with IP 55 class protection
for enclosure, horizontal foot mounted type
with Class - 'F' insulation, conforming to IS-
c) M.S. fabricated Common base plate,
coupling, coupling guard, foundation bolts
etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not less
than 150% discharge at ahead not less than
65% of the rated head.
Supplying, Installation, Testing and
Commissioning of electric driven
1.1.2 1 pressurisation pump suitable for automatic 61717.00 Set
operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal at specified flow of 180 lpm
at 70 m. head conforming to IS: 1520.with
suitable size of footvalve confirming to IS
4038, Pressure rating PN2 , preventing entry
of foreign body to pump through suction pipe,
perfectly flat seating surfaces for good
b) Suitable HP Squirrel cage induction motor
TEFC type suitable for operation on
volts, 3 phase 50 Hz. AC with IP 55 Class of
protection for enclosure, horizontal foot
mounted type with Class F' insulation,
conforming to IS :
c) M.S. fabricated Common base plate,
flexible rubber coupling, coupling guard,
foundtion bolts etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
Supplying, Installation, Testing and
Commissioning of diesel engine driven main
1 fire pump suitable for automatic operation 506181.00 Set
and consisting of following: complete in all
respect as required
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal to ensure a minimum
pressure of 3.5 kg/sq. cm at highest and
farthest outlet at specified flow of 2280 lpm
at 65 m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM water
cooled with radiator, diesel engine
conforming to relevant BS & IS standard
complete with auto starting mechanism,
12/24 volts electric starting equipment,
AH lead acid battery with battery stand,
exhaust pipe extended upto 6 m. outside
pump house duly insulated with 50 mm thick
glass wool with 1.0 mm. thick aluminium
sheet cladding, residential silencer,
instruments and protection as per
specification, stop solenoid for auto stop in
the event of fault with audio indications,
painted with post office red colour etc. as
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates. Tank
shall be provided with inlet, outlet, overflow,
air vent, drain connections, filling connection
& level indicator. Tank shall be mounted on a
suitable steel structure (Painted with 2 coats
of red oxide paint). Tank shall be provided
with two or more coats of synthetic enamel
paint outside over two coats of red oxide
d) M.S. Fabricated Common base plate,
coupling, coupling guard, foundation bolts
etc. as required.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
FIRE CONTROL PANEL FOR Main Hydrant
1 pump and Jockey pump and Diesel Engine 259210.00 No
Fabrication, Supplying, Installation, Testing &
Commissioning of electrical control panel of
cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable
doors, dust and vermin proof, powder coated
of approved shade after 7 tank treatement
process, cable alley, inter-connection, having
switchgears and accessories mounting and
internal wiring, earth terminals, numbering
etc. complete in all respect, suitable for main
fire pump, pressurisation pump complete as
per CPWD specification with following in
coming and Outgoings, suitable for operation
on 415V, 3 phase, 50Hz Ac Supply with
enclosure protection class IP 42 as required
:suitable for operation on 415 V, 3 phase,
HZ, AC supply with enclosure protection
class IP 42 as required.
A. Incoming Feeder:-
(i) 1 No of 200 A,35KA, 415V,FP MCCB with
Thermalmagnetic Based Releases having
O/C, S/C ,E/F protection, Digital ELR
96x96mm with CBCT, FP Spreader
Terminals 1 set= 8 Pcs, Extended Rotory
Handle for MCCB, 240V AC Shunt Trip coil
(ii) LED type indicating Lamp with suitable
rating 2 Amp SP MCB:- 1 Set (each set
comprise of R,Y,B)
(iii) Digital type 3 phase Multi function Meter
with suitable rating of MCB & 3 Nos. of
single core epoxy resin cast type CTs of
200/5 Amps, 10 VA, CL 1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium Busbars
with Heat shrinkable color code insulation
OUTGOINGS:-( All outgoing feeders for
pumps should have digital Ammeter with
selector switches and LED type ON,OFF,Trip
indicating Lamps )
1 sets - 125 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for pump with overload protection,
current sensing type single phase preventor
complete with all acceessories and internal
wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 sets - 125 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for pump with overload protection,
current sensing type single phase preventor
complete with all acceessories and internal
wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 no.63A,16KA MCCB Ics=100%,Extended
Rotry handle with TM release having O/C &
S/C protection with fully automatic star/ delta
starter suitable for pressure pump , current
sensing type, Single Phase Preventer,
ON/OFF Push Button & LED type Indicating
lamps complete with all accessories and
internal wiring required for automatic
operation, selector switch, for local/remote,
auto/manual operation
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt
starting device, timers and relays as
required, push buttons, start/stop in manual
ii) LED type Indication lamp for High/Low
Lub. Oil pressure, High Water Temp and
Engine ON indication.
iii) Battery charger suitable for 12 V/24 V DC
with boost and trickle selector switch, 0-30 V
DC volt meter, 0-20 Amp DC Ammeter.
iv) All standard relays, accessories for
automatic operation of diesel engine, wiring
with 1.5 sq mm PVC insulated copper wire
between various sensors and system
controller / starter, suitable size cable for
battery charging etc. as required.
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to
control operation of Main Electric Fire Pump,
Diesel Pump, Pressurisation Pump, Terrace
Pump in sequence as per specification
consisting of relays, timers, sensors,
annunciation window for fault indication,
control wiring complete as specification.
3 NOS. 25A DP MCB " C " Curve
PRESSURE GAUGES , Air vessel AND
Providing, fixing, testing and commissioning
1.3.1 3 of Pressure Switch with Needle Valve. 1329.87 Set
Providing and fixing in position the
1.3.2 3 industrial type pressure gauges with gun 967.73 Set
metal / brass valves complete as required
Providing, laying, testing & commissioning of
'C' class heavy duty MS Pipe conforming to
IS 1239 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc., in ground
including excavation and providing cement
concrete blocks as support, anticorrosive
treatment with coaltar/asphalt tape as per IS
10221, refilling the trench etc. of following
sizes complete as required .( For HYDRANT
20 100MM Dia 2300.63 Mtr
Providing, laying, testing & commissioning of
'C' class heavy duty MS pipe conforming to
IS 3589/IS 1239 including Welding, fittings
like elbows, tees, flanges,tapers, nuts bolts,
1.5 gaskets etc. and fixing the pipe on the
wall/ceiling with suitable clamp/support frame
and painting with two or more coats of
synthetic enamel paint of required shade
complete as required :
1.5.9 5 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
Supplying and fixing Single headed internal /
External hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel
1.6 coupling and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with blank
Gunmetal/Stainless Steel cap and chain as
9 Single headed Stainless steel 5549.04 No
Providing, fixing, testing and commissioning
of Wall mounting swing type first aid Fire
Hose Reel with drum, hanging bracket, 30 M
1.7 8 x 25 mm dia high pressure hose reel tubing 10499.50 No
as per IS:884 with shut nozzle and ball valve
and all required accessories.
Supplying, Installation, Testing and
commissioning of weather proof Fire Hose
cabinet size 900x 600x300mm to house
fire hydrant & hose, including all other
related accessories fabricated from M.S.
sheet (16 Gauge) of fully welded construction
having front door with locking arrangement,
partially glazed with 4 mm thick glass.
Cabinet shall be powder coated & painted
with post office red colour
Providing ISI marked RRL (IS : 636, type‐A)
fire hose pipe 15 meter long and 63 mm dia
with ISI marked (IS : 903) Stainless steel
1.9 16 male and female coupling bound and rivetted 4020.55 No
to hose pipes with copper rivets and copper
wire complete as required.
Providing Stainless steel ISI marked 63 mm.
dia. male Instantaneous pattern short branch
pipes with 20 mm dia. Nozzle as per IS :
suitable for 10 Kg/sqcm operating pressure
and suitable for interconnections to hose
pipe coupling as required.
Supplying and fixing of fire brigade
connection of cast iron body with gun metal
1.11 male instantaneous inlet couplings complete
with cap and chain as reqd. for suitable dia
MS pipe connection conforming to IS
1 2 way - 100 mm dia M.S. Pipe 6094.09 No
Providing, fixing, testing and commissioning
of 25 mm dia Air Release Valve and Ball
1.12 1 Valve assembly on top of each riser for Air 1949.25 No
release system.
Providing, fixing, testing and commissioning
1.13 1 Pressure Relieaf Valve 25mm dia with Ball 4940.68 No
Supplying and fixing orifice plate made out of
6 mm thick stainless steel (Grade 304) with
orifice of required size to be fitted between
1.14 9 flange & landing valve of external and 1932.76 No
internal hydrants to reduce pressure at the
outlet to the level of 3.5 kg/cm2 complete as
Supplying, fixing, testing and commissioning
of butterfly valve of PN 1.6 rating with
bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as
Providing, installation, testing and
commissioning of non-return valve of
1.16 following sizes confirming to IS:5312
complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
Providing, installation, testing and
commissioning of stainless steel Y-strainer
1.17 fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia holes with
stainless steel flange.
Supply, Installation, Testing and
1.18 9 Commissioning of Brass. Ball Valves with all 737.27 No
fittings required. 25mm size
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv grade
1.19 ISI marked copper wires of following size to
be erected as directed.
60 f) 1.50 Sq.mm 4 core round PVC sheathed 67.00 Mtr
SITC of fire pump start stop push buttons in
SITC of 2 Zone standalone Fire Alarm
control Panel, 16X2 Character LCD
Display, provision for zone wise contact and
1.21 1 sounder. Panel does not have provision to 9300.00 No
connect Repeater Panel. Make: Ravel
Approval: CE Mark. (Including Five year
free maintenance with guarantee)
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.22 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
Supply, Installation, Testing and
Commissioning of Single action Manual Pull
Station.Shock and Vibration Resistant, pull
Down Lever Remains Down Until Reset.
1.23 2 Shall be Polarity Insensitive (with all 1201.75 No
mounting accessories , complete with
Junction Box for mooting on Surface, Cable
lugs at Ends, cable compression glands,
cable tags and ferruling.
Supply, Installation, Testing and
Commissioning of Conventional Sounder
cum strobe having tone settings with range
of 95dbA and field selectable 15/30/75/110
1.24 2 candelas.(with all mounting accessories , 1201.75 No
complete with Junction Box for mooting on
surface, cable lugs at ends, cable
compression glands, cable tags and
CABLES AND TERMINATIONS
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe at road crossing or floor of following
1.25.1 15 (B) 3 core 4 Sq. mm 285.00 Mtr
1.25.2 36 (G) 3 core 6 Sq. mm 392.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe at road crossing or floor of following
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench /
pipe at road crossing or floor of following
size of cables.
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
1.28 insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
1.28.3 4 (D) 2 to 4 core 16 Sq. mm 47.00 No
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made from
sheet steel. The cable tray should be single
or double bended as per required and as per
IS 2062/1079 and shall be coated with hot
1.30. dip galvanizing as per IS 2629/4759. with
max 17.5% perforation with coupler plate /
Fish plate and GI hardware like nut - bolt and
washers etc. erection with necessary
support( included) as per Specification and
as per instruction of engineer in charge..
Supply, installation,testing and
commissioning of Chemical Earthing with UL
Certified 17.2mm Dia. X 3000mm Long
Micron-Copper bonded M.S. Rod
1.31 1 manufactured as per IEC 62561-2 with 25Kg 12230.00 E.a.
Bentonite powder plus " U " bolt rod clamp
complete with Lockable high performence
chamber suitable & tested for 5000T
capacity with SS Hardware.or equivalent
Supplying, Installation, Testing and
commissioning Sewage water submersible
pumping sets of CI casing & impeller, SS
shaft, including with inbuilt water level
sensors for operating the pumps
automatically and all accessories suitable for
operation on 220 V-240 V, single phase,
Hz. AC supply etc. as reqd.
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
Charges of Preparing Design , Drawings
,Testing of Fire Fighting System with
1.33 1 necessary Approval from Local Fire 76271.19 job
authority.( Including Pre-NOC and NOC from
Fire authority. )
Providing, fixing, testing and commissioning
1.34 of below Auto Glow Signages.
1.34.2 4 Fire Equipment: 4" X 12" 514.97 No
In case of Fire, do not use lift, use staircase:
1.34.4 4 Fire Lift 4"X12" 514.97 No
1.34.5 4 Fire Extinguishers 8"x 4" 480.00 No
1.34.6 4 Floor Sign": 4" X 12" 514.97 No
1.34.7 4 Fire Hydrant 4” X 12” 514.97 No
1.34.8 4 Fire Hose Reel.4” X 12” 514.97 No
1.34.9 4 DCP Extinguisher 8"x 4" 480.00 No
1.34.10 4 CO2 Extinguisher 8"X 4" 480.00 No
Providing, fixing, testing & commissioning of
1.35 15mm dia quartzoid bulb type sprinklers of
rating with required accessories :
Pendent Sprinkler 57°C standard response
1.35.1 45 (K-80) UL Listed 362.25 No
Pendent Sprinkler 68°C standard response
1.35.2 5 (K-80) UL Listed 471.50 No
Supplying, installation, testing &
commissioning of sprinkler flexible pipe (UL
Listed) of stainless steel complete with
NPT on reducer thread with maximum
working pressure of 175 PSI test pressure of
1.36 875 PSI (Burst) with branch line (Inlet) 25mm
NPT male thread to sprinkler head (Outlet)
15mm NPT female thread with reducer,
nipple, 2 side brackets,center bracket,
stockbar of following sizes complete as
required etc of following sizes as required:
Providing fixing, testing and commissioning
of Drainning & Testing Assembly 25mm dia
1.37 1 with Sight Glass , Union joint , Ball Valve & 4939.25 No
SUB-TOTAL OF FIRE HYDRANT System
FIRE EXTINGUISHERS AND LIGHTNING
2.1 FIRE EXTINGUISHER
FIRE EXTINGUISHER Supplying,
Installation, Testing and commissioning of
Dry Chemical Powder (DCP) 6 Kg Fire
Extinguisher Mono Ammonium Phosphate
Powder 40, Stored Pressure Type, Pressure
2.1.1 4 Gauge, Controllable discharge mechanism 2724.25 No
Class A, Rating 3A & Class B rating 21B as
per IS 15683 ISI MARK (ABC Dry Chemical
Powder - MAP 40%)fitted with required
accessories including wall suspension
Supplying, fixing, testing and commissioning
of CO2 type Fire Extinguisher of capacity
4.5 kg filled with Co2 Gas as per IS
2.1.2 4 with controll discharge mechanismfitted with 6526.00 No
Hose & Horn applicable on Class B fire
rating 21B confirms to IS 15683, bearing ISI
mark. Co2 Cylinder as per IS
Providing & fixing of ISI marked water CO2
type Portable fire extingusher,9 LTR
capacity, Hydraulic test pressure 35Kgf/
cm2, Discharge range 2 Mtr,Average
discharge time: Min. 13Sec,Fire Rating
3A,Grade: IS:15683.
Providing & fixing of ISI marked, Squeeze
Grip Cartridge Type water CO2 type Portable
fire extingusher,9 LTR capacity, Hydraulic
2.1.4 1 test pressure 35Kgf/ cm2, Discharge range 2 4200.00 No
Mtr,Average discharge time: Min. 13Sec,Fire
Rating 3A,Grade: IS:15683.
Providing,fixing, testing and commissioning
of 10Kg Modular type fire extinguisher having
Nitrogen expellant ,ceiling mounted,Sprinkler
2.1.5 1 Nozzle is gas tight the release temperature is 2950.00 No
adjusted with sprinkler imported bulb set at
57 degree C or 68 degree C ,coverage area
SUB TOTAL of FIRE EXTINGUISERS
3 FIRE DETCTION & FIRE ALARM SYSTEM
SITC of Microprocessor based Net-workable
Analogue Addressable Fire Alarm Control
Panel. The Panel shall be compliant with
EN54-2, EN54-4 and approved by LPCB.
The Fire Alarm Control Panel shall have
inbuilt one loop. The Panel must have large
graphic display. The Panel must also have
the capability to take Addressable Intelligent
3.1 1 Wired and Wireless Devices on same loop. 118852.50 No
Each loop shall have a capacity of
analogue Addressable devices and 127 Base
sounders/Base Sounder Beacons. The Panel
shall have 240 V AC power supply along with
automatic Battery Charger. Non-Networkable
Approved by LPCB (Including Five year free
maintenance with guarantee)
SITC of Analogue Addressable Multi-
Sensor which is fully compatible with
Analogue Addressable Protocol,having
removable high performance chamber with
Twin fire LED's allow 360 degree viewing,
User selectable sensitivity modes 1% to
3.2 55 4.5% obs/m, Incorporate Optical and dual 3597.20 No
Heat elements, lock mechanism (sensor to
base), Electronically addressed, Pulsing/non-
pulsing controlled from panel. Approved by
LPCB & VdS. (Including Five year free
maintenance with guarantee)
SITC of Analogue Addressable Multi- Heat
Sensor which is fully compatible with
Analogue Addressable Protocol,having
removable high performance chamber with
Twin fire LED's allow 360 degree viewing,
User selectable sensitivity modes 0 to
3.3 4 degree Celsius, Incorporates Fixed 3498.30 No
Temperature and Rate Of Rise Heat
elements, lock mechanism (sensor to base),
Electronically addressed, Pulsing/non-
pulsing controlled from panel. Approved by
LPCB (EN54: Part 5) (Including Five year
free maintenance with guarantee)
SITC of sensor common mounting base,
includes stainless steel contacts, slim profile
- only 8mm, quick connection via square
3.4 59 cable clamps, facility for remote indicator, 354.20 No
Approved by LPCB (Including Five year free
maintenance with guarantee)
Supply,Instllation,Testing and
Commissioning of Fault isolator Module
capable of monitoring shorted loop circuit
3.5 6 and automatically restore communications 2477.10 No
when shorted conditions are corrected
(Including Five year free maintenance with
Supplying, installation, testing &
commissioning of response indicator on
3.6 8 surface/recessed MS Box having two LED, 193.20 No
metallic cover complete with all connections
etc as required.
SITC of Manual Call Point approved to
EN54-11:2001, Approved by LPCB Easy to
3.7 6 install, push-fit wiring terminals (Including 4191.75 No
Five year free maintenance with guarantee)
SITC of Analogue addressable loop powered
Base Sounder, variable sound output 50 ~
98 dB(A) (±2 dB(A)) output at 1 metre,
user-selectable tones (all tones EN54-3
compatible), Auto shutdown feature prevents
noise-pollution, Approved by LPCB & VdS
(Including Five year free maintenance with
Supplying & laying of 2x1.5 sqmm fire alarm
armoured cable, 600/1000V rated with
3.9 650 annealed copper conductor having XLPE 135.70 Mtr
insulation, steel wire armouring & FRLS
outer sheath complete as required.
SUB -TOTAL OF FIRE DETECTION&
Annual Comprehensive Type
Maintenance Contract of for Above Fire
Fighting System For 1-Year DLP + ONE
Every six months Testing certificates with
Photographs should be sent to competent
authority by concern contractor.
Annual comprehensive Type Maintenance
4.1 1 Charges only During 1st Year DLP / Defect 0.00 Year
Liability period.
Annual comprehensive Type Maintenance
4.2 1 Charges for 1st Year after Guarentee / 73964.43 Year
Defect Liability period.
SUB TOTAL of Annual Comprehensive
Maintenance of Fire Fighting Sytem
Furniture Work ( Curtains and Cupboard
Proviging and Fixing Storage Shutter made
out of 50mm X 25 mm Indian Teakwood
Frame and 18 mm Ply Board. With 1 mm
thick laminate finish in the front and 0.8 mm
thick Laminate on Back Side with 12 mm
thick Indian teakwood beading. The scope
also include providing and fixing s.s. finish
hardware as per the Requirement. The rate
include cost of all labour, material and with
all hardware like handle, magnate, tackels,
adhesive, screws, etc.for satisfactory
completion of this items.All Exposed Wood
Work shall have malamine polish etc.
Meeting Table Ovel M4 ( 1355 MM WIDE )
Providing and supplying meeting table ovel in
shape of size 1355 mm Wide as shown in
drawing.The top made out of 19 mm thk.ply
wood with laminate top as shown in
drawing.20 mm thick teak wood beading is
provided all around table top with 5 mm
groove in the center. The top is supported by
2 nos. of vertical square box made out of
mm thick ply board of size 300mm x 300mm
rest on the wooden base of size 400mm x
400mm x 40mm as shown in drawing.The
rate includes cost of all labour,material and
tools,tackles,adhesive,screws,etc.for
satisfactory completion of this item.
Providing & Fixing Sun Control Reflective
Type Film / Frosted Film as Selected by
3 150 Architect/ Engg. In Charge For Glass Doors / 646.37 Sq.mt.
Windows etc. as Directed.
Providing & Fixing in Position Vertical Roller
Blinds with Minimum 3 % and Maximum 5 %
Light Transperace Screen Fabric Incuding
Providing & Fixing of Powder coated G-
Channel at the Topof Window with necessary
Screw , Cleats etc. and PVC Roller ( Weight
Pipe) and PVC Chain For Up and Down
4 140 Movement of Blinds etc. of Approved Make 1372.03 Sq.mt.
and as per Drawings / Instruction of Engg. in
Charge For All Colors and Shades. Rates
Includes all Lead and Lift For All Floor Level,
All Height , All Material , Accessories, Fixing
Scaffolding , Labor etc. Complete in All
Respects. All Required Accessories &
Material must be From Same Manufacturer.
Cubical track for cubical curtain :- supply and
installation of heavy duty Aluminium cubical
track size 20mm wide x 30 mm high, made of
aluminium Extruded with white powder
coating complete with continous PVC liner,
nylon giders and hooks , plastic end cap,
connecting bridge, overlapping joint
connector, Wall bracket with matching
screws to make up cubicle approx. height to
2100 mm clearance from floor level at
approx. 1000 mm spacing with all
accessories of approved brand/make along
with alluminium Extruded hospital curtain's
track system with shite powder coating with
all accessories as per approved sample. All
required accessories and materials must be
from same manufacturer. This Item is
Excluding Curtain.
Cubicle Curtain :- Supply & Installation of
Water Repellant, Antimicrobial Cubicle
Curtain with High Strength18" Oval net at
Top as Approved by Consultant / Engg. In
6 50 Charge. Eyelets on Curtains & Hooks and All 400.00 Sq.mt.
other Required Accessories, Fixing
Scaffolding, Labor etc. Complete in All
Respects. All Required Accessories &
Material must be From Same Manufacturer.
Total of Furniture Work ( Curtains and
Cupboard Shutter) Total Rs.
Signature of Bidder
Special Condition For Tenderers
• Scope includes Complete Demolition of Super Structure & Sub Structure up to
Foundation Level of Existing Old Buildings in the Said Plot Under Development as
Instructed by Engg. In Charge & Then Disposal of Serviceable & Un Serviceable
Material including Cleaning & Levelling of Entire Plot. The Total Project Includes
Demolition of Existing Units and Site Clearance. The Total Responsibility and
Liability of This Demolition Works Including Site Clearance Shall Be of The
Contractor. This Demolition and Debris Removal Includes all Hidden Foundation
also at Locations Where New Foundation or New Work is To Be Done.
• Contractor Has to Visit Site with representative of A.M.C. Before Quoting Amount in
Tender. The Contractor Shall Not Be Paid For Any Dismantling, Demolition, Carting
The Debris And/ or Any Expenses Incurred For Site Clearance.
• Contractor shall have to Pay Premium Amount to A.M.C. For Disposal of Serviceable
Goods Like Old Reinforcement, Old Wooden Doors/Windows, Iron Work,
Copper/Alu. Wiring, Bricks etc. Which shall be Quoted in Part-A of Financial Bid.
• For Consideration of Lowest Eligible Bidders , Premium Amount as Mentioned
Above i.e. Part-A shall be Deducted From e-Tender Amount For Construction Work
i.e. Part-B , Quoted by the Contractors.
• The Lowest Eligible Bidder shall have to Deposit Premium Amount for the
Serviceable Goods at the Time of Submission of Security Deposit.
Signature of contractor Additional City Engineer (NORTH ZONE)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- NORTH ZONE
Name of Work : CONSTRUCTION OF U.H.C. BUILDING AT F.P. NO :- 5/P, T.P.S. NO: 12 IN INDIACOLONY
WARD, NORTH ZONE, AHMEDABAD.
FINANCIAL BID (Online Only)
Demolition of Existing Structure
Sr.No. Description Amount
Quoted Premium Amount For Serviceable Material (Which is Payable to
1 A.M.C. at The Time of Depositing Security Deposit by the Lowest Eligible
Amount in Words Rupees :
Sr.No. Description Amount
1 Amount For Civil Work Rs.2,79,76,279.99
Amount For Electrical Work with Annual Operation & Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For CCTV Work with Annual Operation & Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For Fire Fighting System Work with Annual Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
5 Amount For Furniture Work ( Curtains and Cupboard Shutter) Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs. 3,83,89,585.15 Estimated cost put to tender : Rs.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Net Tender Amount For Consideration of Lowest Eligible Bidders
Sr.No. Description Amount
1 Net Amount For Cost of Civil , Electrical, Fire Fighting, O&M, Landscaping
and Interior & Furniture Work i.e. Part-B Rs.
2 Quoted Premium Amount Payable to A.M.C. i.e. Part-A Rs.
3 Net Tender Amount i.e. (Part-B -
Net Tender Amount in Words Rupees :
Signature of contractor Additional City Engineer ( N.Z. )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NZ_UHC_Final Price Bid Vol.-II_Dt.25-03-2026.pdf
NZ_UHC_Notice Inviting Tender.PDF
NZ_UHC_Vol-1 part A Tender Document.PDF
NZ_UHC_Vol-1 Part B TS_Civil Work Dt. 26-03-2026.pdf
NZ_UHC_Vol-1 part-C Electrical Specification Dt.26-03-2026.pdf
NZ_UHC_Vol-1 part-D CCTV Work Specification Dt.26-03-2026.pdf
NZ_UHC_Vol-1 part-E Fire Fighting Specification Dt.25-03-2026.pdf
TENDER DRAWING INDIACOLONY UHC.pdf
Download all tender documents and submit your bid