Executive Engineer, R and B Division, Himatnagar
Construction of Government Girls Hostel (CAP-100) at Khedbrahma.Dist Sabarkantha
300089
12 of 2025-26
Open
Civil Works - Buildings
Works
Sabarkantha
15 documents required · 15 mandatory
₹12,000
Executive Engineer, R and B Division, Himatnagar
₹7.7 L
30 Apr 2026
30 Apr 2026
30 Apr 2026
1 Jun 2026
30 Apr 2026
Name of work :-
Construction of Government Girls Hostel (CAP-100) at
Khedbrahma.Dist Sabarkantha
DISTRICT :- Sabarkantha
Taluka Name of Work Amount Put to Tender
Construction of Government Girls Hostel
1 Khedbrahma (CAP-100) at Khedbrahma.Dist Sabarkantha
GOVERNMENT OF GUJARAT
ROADS AND BUILDING DEPARTMENT
SACHIVALAY, GANDHINAGAR
Name of work :-
Construction of Government Girls Hostel
(CAP-100) at Khedbrahma.Dist Sabarkantha
Bill of Quantities
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
1 Excavation for foundation upto 1.5 m depth including 1147.60 Cum 277.10
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(D) Soft rock not
requiring Blasting
2 Filling available excavated earth (excluding rock) in 1157.00 Cum 136.92
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
3 Filling in plinth with sand under floors including watering 98.00 Cum 481.81
ramming, consolidating and dressing complete
4 Filling in foundation and plinth with murrum or selected soil 492.00 Cum 294.39
in layers of 20cm. thickness including watering, ramming
and consolidating etc. complete.
5 Providing and laying controlled cement concrete M.150 for 275.00 Cum 4237.96
curing complete including cost of formwork but excluding
the cost of reinforcement for reinforced concrete work in (A)
Foundations, footings,Base of columns and Mass concrete
6 Providing and laying controlled cement concrete M.250 and 355.20 Cum 4500.36
curing complete including cost of formwork but excluding
the cost of reinforcement for reinforced concrete work in (A)
Foundations, footings, Base of columns and Mass concrete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
7 Providing and laying controlled cement concrete M250 and 15.00 Cum 7008.39
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, pillars posts and struts Column Up to
8 Providing and laying cement concrete 1:4:8 (1- Cement : 4- 34.00 Cum 3374.11
coarse sand : 8- Machine Crushed stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
9 Providing and laying controlled cement concrete M.250 and 111.00 Cum 6002.43
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work for Ground and Plinth Beams
10 Providing and laying controlled cement concrete M.200 and 110.00 Cum 7862.46
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Columns, Pillars posts and struts, For All Floors.
11 Providing and laying controlled cement concrete M.200 and 24.00 Cum 8001.67
curing complete including the cost of formwork (Vertical
fins and vertical sun breakers.) and reinforcement for
reinforced concrete work in (B) Walls, for all floor level
12 Providing and laying controlled cement concrete M.200 and 250.00 Cum 6136.46
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Beams For All Floors.
13 Providing and laying controlled cement concrete M.200 and 390.60 Cum 6441.40
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Slab for All Floors.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
14 Providing and laying controlled cement concrete M.200 and 36.00 Cum 6454.21
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Lintels For All Floors.
15 Providing and laying controlled cement concrete M.200 and 11.00 Cum 6989.40
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Chajja For All Floors.
16 Providing and laying controlled cement concrete M.200 and 22.00 Cum 6905.88
curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in (E) Staircases
17 Providing TMT Bar FE 500D reinforcement for R.C.C. 225348.00 Kg. 77.29
work including bending, binding and placing in position
complete for All Floor
18 Providing throating or plaster drip and moulding to R.C.C. 218.00 Rmt 43.08
Chhajja by making 5mm to 15mm wide grove as per design
19 Brick work using Common Burnt Clay building bricks 487.00 Cum 4546.91
having crushing strength not less than 35 kg./Sq.Cm. in
Super structure Above plinth level up to All Floor levels in
Cement Mortar 1:6 (1- Cement : 6 -fine sand)
20 Half brick masonry in common burnt clay building bricks 612.00 Sqmt 691.76
having crushing strength not less than 35 Kg/Sq.Cm. in
Superstructure above plinth level upto All Floor level in
Cement mortar 1:4 (1- Cement : 4 -coarse sand )
(Conventional).
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
21 Providing & Fixing Chicken mesh for joint between brick 380.00 Sqmt 173.72
work & RCC work fixing with nail & GI washer as per
director in charge
22 Providing 15mm thick cement mala plaster in single coat on 4288.00 Sqmt 270.83
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth fininshing with a
floating coat of neat cement slurry in (i) Cement mortar 1:3
(1-cement:3-sand), 10x10 mm groves etc. Complete for All
23 Providing 10mm thick cement mala plaster in single coat on 3793.00 Sqmt 241.46
brick/concrete walls for interior plastering and finished even
and smooth fininshing with a floating coat of neat cement
slurry in (i)Cement mortar 1:3 (1-cement:3-sand). Complete
for All Floors.
24 20mm thick sand faced cement plaster with Gutka Finish on 2127.00 Sqmt 321.10
walls upto height 15 metres above ground level consisting of
12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand)
and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) with 5mm grooves, etc. complete.
25 Providing Water Proofing Treatment on Sunk Slab including 183.00 Sqmt 370.67
cement concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-
graded stone aggregate 20mm nominal size) laid in one layer
and finished with a floating coat of neat cement average
50mm thick to prepare slope including water proofing
chemical etc. Complete for Sunk Slab for All Floor.
26 Applying two coats of putty & two coats of primer of 8018.00 Sqmt 40.59
approved brand and manufacture on new wall surface to give
an even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand
papered smooth.
27 Wall painting (three coats) with plastic emulsion paint of 4260.00 Sqmt 125.52
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
28 Ceiling painting (three coats) with plastic emulsion paint of 3805.00 Sqmt 131.02
approved brand and manufacture on ceiling and soffits of
slab surface to give an even shade including throughly
brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
29 Finishing wall with weather proof exterior emulsion paint 2692.00 Sqmt 93.93
(two coats) with Damp Proof Coating (one coat) on wall
surface to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, and
remains of loose powdered materials.etc complete
30 Providing and laying polished Kota stone slab flooring over 1587.00 Sqmt 1019.00
20mm (Average) thick base of cement mortar 1:6 (1-cement
: 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse
sand) laid over and jointed with grey cement slurry mixed
with pigment to match the shade of slab including rubbing
and polishing etc. complete. (A) 25mm thick
31 Providing and laying polished kota stone slab 25mm thick in 105.00 Sqmt 1166.93
risers of steps,skirting Dedo and pillars laid on 10mm thick
cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed
with gray cement slury mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete.
32 Providing and fixing pre-cast Rubber Dye / steel Dye inter 823.00 Sqmt 706.93
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 :
including 35 mm Sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC :
SP 63-2018 etc. Complete.
33 Providing and fixing Machine cut & Polished kota stone in 50.00 Sqmt 1355.42
7.5 cm width Strip flooring for Ramp even grade over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete. (A) 25mm thick
34 P & L 24" x 24" Ceramic 10 mm thick tile flooring over 20 246.00 Sqmt 1266.54
mm (average) base of cement mortar 1:6 ( 1 cement:
coarse sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including
finised with flush pointing & cleaning the surface etc.
complete for antiskit
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
35 Providing and laying coloured glazed tiles of the size 300 1196.00 Sqmt 1487.88
mm x 450 mm x 8 mm in skirting, risers of steps and dedo
on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse
sand) & jointed with white cement slurry.
36 Providing and laying Ceramic tiles 6mm thick in skrting 14.00 Sqmt 1090.32
risers of steps and dedo on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand) and jointed with white cement slurry
37 Providing and fixing Machine cut, Free edges, Mirror 93.00 Sqmt 2464.40
Polished Granite stone slab flooring 18mm thick laid on
20mm (Average) thick base of cement mortar 1:6 (1-cement
: 6-coarse sand) for Trade & Riser including Half Round
moulding front edge of trade jointed with grey cement slurry
mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete.
38 Providing and fixing Machine cut, Free edges, Polished 438.00 Sqmt 2510.86
Green Granite stone slab flooring 18mm thick for vertical
wall/Doors/Windows Sill, Jams for cladding as per design
including full moulded round inside edge and laid on10mm
thick base of cement mortar 1:3 (1-cement : 3-coarse sand)
jointed with grey cement slurry mixed with pigment to
match the shade of slab including rubbing and polishing etc.
39 Providing and laying water prooofing treatment with china 728.00 Sqmt 1132.21
mosaic tiles flooring over avg 50 mm C.C. 1:2:4 bedding
maintaining slope for plain and curve surface & 12 mm to
20 mm broken pieces not more than 2.5 cm of ceramic/ of
glazed tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar creme out upto
surface using white cement including rounding off junctions
and extending them upto 15 cm along the wall,clearing with
water and oxalic acid etc. as directed.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
40 Constructing Sandwich Platform of 18mm thick polished 50.00 Sqmt 2760.33
black or selected granite at top and 25 mm thick kota stone
with 75cm height with necessary support using 20mm thick
cement mortar 1:3 for sandwich and fitting at bottom &
edges with waterproof rigid adhesive including making
necessary grooves in walls with vertical support of double
kota stonr sandwich every 60cm centre to centre including
all labour material of approved quality including full
moulded round front edge fixed in wall for partition.
41 Providing and fixing flush door with Single shutters, solid 155.00 Sqmt 4129.89
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery
including 30cm long Stainless Steel Pipe handle on both
side SS ASIS 304 grade, SS Stopper 20cm, SS Aldrop 30cm
both side, anodised alluminium butt hinges with necessary
screws. (B) Non-decorative type and block board core
anodised alluminium butt hinges in flush door shutters (2)
42 Providing and fixing flush door with Double shutters, solid 12.00 Sqmt 5279.27
core construction with frame of first class hardwood with
cross board and finished with 1 mm thick laminate on both
side of shutter, machine glued PVC beading on periphery,
including 30cm long Stainless Steel Pipe handle on both
side SS ASIS 304 grade, heavy duty Floor Spring each side,
SS Stopper 20cm, SS Aldrop 30cm both side, anodised
alluminium butt hinges with necessary screws. (B) Non-
decorative type and block board core anodised alluminium
butt hinges in flush door shutters (2) 35 mm thick.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
43 Providing and fixing window having extruded aluminum 144.00 Sqmt 1738.21
Colour anodized section frame main outer size 95mm x
24mm x 1.17mm @ wt.of 0.738 Kg/mt , horizontal Three
track member size 92mm x 31.75mm x 1.30mm,@ Wt.1.07
Kg/mt , vertical member of size 92mm x 31.75mm x
1.50mm @ Wt. 1.06 Kg/mt with sliding shutters of
horizontal member size 40 mmx18mm x1.29mm @ wt.of
0.456 Kg/mt, vertical member of size 40mm x 18mm x
mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent
bronze colour tinted float glass with rubber gasket and
airlock strip anodiazed aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details
etc. With Mosquito net shutter in outer track.
44 Providing and fixing standared extruded of alluminium 16.00 Sqmt 2131.10
section of size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094Kg /
Rmt with colour anodized alluminium frame with 5 mm
thick transparent bronze colour tinted float glass as details
etc complete for Fix window with Mosquito net.
45 Providing and fixing Louvers in G.I Channel 40x32x5mm 101.00 Sqmt 2215.94
size And 114mm Wide G.I Sheet Having Thickness of
0.55mm & Weight Not Less Than 490 Gm/Mtr. Roll
Formed to create 84mm wide Louver snap fixed on special
shaped G.I Channel,Channel shall be Finished with Powder
Coating of 55 micron For Fix Louvers As Directed By
Engineer In Charge.
46 SIGNAGES ON DOOR :Providing and fixing 304 grade 42.00 Nos. 1262.50
stainless steel 1.5mm thick brushed steel finish plate fixed
on a door using S.S studs and with punched (laser cut)
lettering carried out on S.S plate of required size and text as
directed by engineer etc. complete. Size 30 cm x 15 cm
47 Providing erecting and fixing double coated ISI water tank 20000.00 Litre 3.95
of required capacity each with all necessary fittings and
connection etc. complete on terrace
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
48 Providing, laying and jointing in true line and level 110 822.00 Rmt 876.11
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
of PVC clamp of the size 110 mm diametre x 149 mm
length x 145 mm heigh at every 2000 mm center to center or
shall be concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of pipes
and joints and jointed with adhesive solvent cement
including cost of all materials.
49 Providing, laying and jointing in true line and level 160 408.00 Rmt 834.38
diameter U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber ring,
& fittings conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
of PVC clamp of the size 160 mm diametre x 210 mm
length x 196 mm heigh at every 2000 mm center to center or
shall be concealed in walls as directed including necessary
fittings such as bends, shoes etc. including testing of pipes
and joints and jointed with adhesive solvent cement
including cost of all materials.
50 Providing laying and jointing in true line and level 50mm 86.00 Rmt 195.67
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
materials. laying and jointing in true line and level 25mm
51 Providing 655.00 Rmt 91.84
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
materials. laying and jointing in true line and level 15mm
52 Providing 350.00 Rmt 72.65
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
53 Providing and fixing concealed center point to wall ceiling 105.00 Rmt 253.82
& floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete. 25 mm.
54 Providing and fixing concealed center point to wall ceiling 150.00 Rmt 170.36
& floor CPVC (SDR 13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete. 15 mm.
55 Providing and fixing Gun metal check or non-return fullway 17.00 Nos. 420.63
wheel valve.(C) 25mm dia.
56 Providing and fixing ball cock of approved. quality as 2.00 Nos. 189.84
directed.(A) Copper Metal (ii) 50mm dia.
57 Providing and fixing C.P. brass shower rose with 15mm or 40.00 Nos. 282.16
20mm inlet.(A) 100mm dia. Each
58 Providing and fixing wash down water closet (Wall Hung 23.00 Nos. 5172.51
type, W.C. Pan) with integral P or S trap, Health Fauset
Heavy Duty with hook and PVC dual flush tank with
complete fittings including jointing the trap with soil pipe in
Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover
to be measured and paid for separately)(A) vitreous China
Pattern :(i) in white colour
59 Providing and fixing washbasin (ii) Flat Back washbasin 15.00 Nos. 2180.72
550 mm x v 400mm size. (i) In white colour including with
approved sanitary grade material with CP waste coupling,
waste pipe, 15mm dia Pillar & Stop Cock of approved brand
with connection 15mm dia flexiable pvc pipe etc. complete
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
60 Providing and fixing Kitchen sink with C.I. or M.S. 2.00 Nos. 2987.87
brackets, painted white including cutting holes in walls (C)
Vitreous China Sink.(i) 600mm x 450mm x 150mm size
including approved sanitary grade material with CP waste
coupling, waste pipe, 15mm dia Pillar & Stop Cock of
approved brand with connection 15mm dia flexiable pvc
pipe etc. complete
61 Providing and fixing screw down bib taps of following 85.00 Nos. 186.83
size.(A) Brass screw down bib tap polished bright. (i) 15mm
62 Providing and fixing PVC SWR Nahni trap IS 14735 for 51.00 Nos. 586.60
drain - 100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making good
63 Providing and fixing S.W. gully trap with C.I. grating brick 40.00 Nos. 1246.92
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps.(B) 150mm x 100mm size P or R type
64 Providing and fixing C.P. brass towel rail comlete with C.P. 29.00 Nos. 616.42
brass brackets fixed to wooden plugs with C.P. brass
scews.(B) 600mm x 20mm size.
65 Providing and fixing 600mm x 450mm bevelled edge mirror 12.00 Nos. 859.41
of superior glass mounted on 6mm thick A.C. sheet or
plywood sheet and fixing to wooden pluge with C.P. brass
screws and washers.
66 Providing and fixing in position PVC cowel went to pipes 12.00 Nos. 75.75
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
67 Constructing brick masonry chamber for underground C.I. 25.00 Nos. 3660.76
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions
total weight of cover with frame to be not less than 38Kg.
(Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top
slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation concrete 1:5:10
inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed
concrete etc. complete.(ii) Inside dimensions 500mm x
mm and 450mm deep for pipe line with one or two inlets.
68 Providing and laying (to level or slopes) and jointing with 20.00 Rmt 531.18
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete and Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm
nominal size) bedding for stoneware pipes of following
internal diameters with necessary formwork and curing
complete.(B) 150mm dia.
69 Providing and laying (to level or slopes) and jointing with 20.00 Rmt 352.73
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete and Providing and laying Cement concrete 1:5:10
(1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm
nominal size) bedding for stoneware pipes of following
internal diameters with necessary formwork and curing
complete.(A) 100mm dia.
70 Applying general insecticide pest control treatment to floors, 819.00 Sqmt 80.62
cupboards etc including labour materials etc. complete.
Using Imidacloprid 30.5 SCas Per IS 6313 part -II( (0.075%
concentration by mass) is recommended 10.5ml chemical
diluted with 5 liters of water application 0.5 litre chemical
/Sqm of surface is recommended as per I.S.
71 Providing and fixing Safety Grills of required pattern for 4765.00 Kg 110.60
windows/door using MS polished bars, Rectangular CRS
Pipes of size 50mm x 30mm x 2mm or Required at required
spacing as per design and hold fast with coach bolts
including one coat of and two coats of matt finished oil
painting etc. complete
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
72 Providing and fixing a set of wall mounted 38mm dia. U 1.00 Nos. 2323.00
shaped horizontal stainless steel collapsible grab bar, 38mm
vertical stainless steel fixed grab rail of grade SS 304 from
round pipe supported and 75mm dia 8mm thick SS 304 base
flange on wall including anchor fastners, nuts, accessories as
per detailed drawing etc. complete as directed by architect or
engineer in charge.
73 Providing and fixing of conspectus tape 50mm width on of 160.00 Rmt 1923.04
treads in staircase including cutting pasting etc. As per
harmonised guidelines complete in all respect to the entire
satisfaction of engineer in charge.
74 Providing and fixing 90 cm high Stainless Steel railing made 91.00 Rmt 3760.33
from anticorrosive 304 grade S.S. pipe of 50 mm dia. (16
gauge) as hand rail with S.S.304 grade baluster of 32 mm
dia (16 gauge) as a vertical support fixed in RCC Slab/ steps
of stair at 1.2 mt. c/c including three horizontal S.S. pipes of
16 mm dia (16 gauge) at equal distance fixed by 16 mm dia
(16 gauge) S.S. pipe with baluster including accessories as
per detailed drawing as directwed etc. complete
75 Providing and Fixing 8mm thick poly- Carbonate fiber sheet 14.00 Sqmt 2940.82
using sealant water proofing rubberished adhesive oil
painted 50x50mm hollow channel for framing of shade as
require and fixing frame with surrounding wall etc.
completed as directed.
76 Steel work, welded in built up sections framed work 125.00 Quintal 9108.48
including cutting, hoisting, fixing in position and applying a
priming coat of red lead paint. (A)In beams and joists,
channels angles Tees, flats, with connecting plates or angle
cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
77 Painting two coats (excluding priming coat) on external 125.00 Sqmt 22.75
surface of new rain water, soil, waste and vent pipes and
fittings with ready mixed bituminous brushing, black,
anticorrosive to give an even shade including cleaning of
all dirt, dust and other foreign matter. (B) 75mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
78 Brick work using common burnt clay building bricks having 92.60 Cum 4214.33
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)
79 Brick work using Common Burnt Clay building bricks 145.00 Cum 4495.99
having crushing strength not less than 35 kg./Sq.Cm. in
Super structure Above plinth level up to floor two level in
Cement Mortar 1:6 (1- Cement : 6 -fine sand)
(Conventional) upto Floor two level
80 Providing and laying controlled cement concrete M.150 and 16.00 Cum 7426.53
curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work for Coping
81 Providing & laying weep hole in Aburtments, and returns by 863.00 Each 86.73
using A.C. pipe of 100mm including laying in proper grede
and jointing the completed as per detailed specification.
82 Providing 15mm thick cement mala plaster in single coat on 721.00 Sqmt 241.38
Rough (Similar)side of single or half brick walls for interior
plastering and finished even and smooth fininshing with a
floating coat of neat cement slurry in (i) Cement mortar 1:3
(1-cement:3-sand), 10x10 mm groves etc. Complete for upto
Floor two level.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
83 Providing and fixing concertina coil fencing with punched 265.00 Rmt. 565.60
tape concertina coil 600 mm dia 10 mt openable length
having 50 no rounds per 6 mt length, upto 3mt height of wall
with existing angle iron (50mm x50mm x5mm )requird
shaped As per Directed Engeenier in charge. placed 2.4mt or
3.00mt apart and with 4 horizontal R.B.T. reinforced barbed
wire(3 mm) , stud tied with G.I. staples and G.I. clips to
retain horizontal, including necessary bolts or G.I.barbed
wire tied to angle iron, all complete as per direction of
Engineer-in-charge, with reinforced barbed tape
(R.B.T.)/Spring core (2.5 mm thick) and weight
gm/meter at compound wall for ESR M4/intakewell.
84 Drilling of pilot bore hole of size 250/300 mm diameter at 350.00 Rmt 1544.29
above site by mud finish direct rotary rig etc. complete
85 Reaming of 250/300 mm diameter pilot bore hole to size 250.00 Rmt 742.35
450 mm diameter including assembling, lowering housing,
casing strainer pipes with gravel packing and clay ball
packing etc. complete.
86 Providing 600 CFM / 150 PSI capacity air compressor upto 1.00 Job 25118.70
available of sand free discharge ( Minimum 6.0 Hours)
87 Supply of reducer made frim 6 mm thick plate (M.S.) for 1.00 Nos. 2009.90
ERW pipe of size (ii) 200 mm dia. x 250 mm dia. X
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
88 Supply of 200 mm diameter V-wire screen pipe of slot size 105.00 Rmt 1401.88
1.0 mm nominal hole etc. complete.
89 Supply of M.S. Bore clamps with 3 holes on either side with 1.00 Pair 1753.36
nuts and bolts of standard make and suitable size (g)
mm x 75 mm x 16 mm flat to 200 mm dia. Pipe.
90 Supply of Bore Plug having 100 mm height made from M.S. 1.00 Nos. 834.26
plate with 3 holes at equal distance on circumference for
nuts-bolts type, locking arrangement with nut-bolts & lock
nuts of standard make complete. (b) from 5 mm thick M.S.
plate (for top also) (ii) suitable for 200 mm dia. pipe.
91 Supply of M.S. Bail Plug having length of 0.45 mtr from 1.00 Nos. 907.99
medium class pipe as per I.S.S. suitable for (b) 200 mm
diameter pipe etc. complete.
92 Supply of Steel Bent plates suitable to ERW pipe for (b) 200 8.00 Nos. 71.71
mm diameter and 150 x 150 x 6 mm size etc. complete.
93 Supply of Gravel of size selected size up to 4mm to 6 mm, 12.00 Cmt 2295.73
including stacking and filing etc. complete.
94 Charges for uptron make Electrologger (with carting ) of 1.00 Job 12120.00
pilot bore hole etc. complete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
95 Charges for Geo Hydrological ground water investigation 5.00 Job 16160.00
including water sample chemical analysis etc. complete.
96 S.I.T.C. submersible pump set suitable for bore of 150 mm 1.00 Each 49148.62
dia or more having 3 phase motor capacity not less than
HP with following capacity. Lifting and Lowering taken
extra. [C] 25 stage 160 to 100 LPM discharge at 185 to
mtr head for 50 mm dia delivery pipe
97 Providing and erecting PVC corrugated Flexible conduit 225.00 Rmt 26.26
with required numbers of coupling, PVC bushes, Check-nuts
etc. complete of following sizes. (3) 32 mm diameter
98 Lowering of submersible motor pump set complete with 1.00 Job 2568.43
required. Nos. and size of casing pipes erected by means of
proper chain pulley block & pipe wrenches after checking of
threads of each pipe with coupling to take the load of the
pump set and pipe assembly filled up with water. (B) Above
60 mtr and up to 120 mtr
99 Supplying and erecting approved make motor control 1.00 Each 8710.24
cubical panel (Direct - on - line) made from 16 G. CRCA
sheet duly epoxy powder painted inside and outside with
hinged doors and locking, arrangement consisting of suitable
size of ON-OFF isolator (AC - 3/23 duty) main fuses, single
phasing preventer, indicating lamps for R-Y-B phases,
overload relay, automatic water level controller, Ammeter,
Voltmeter each with two way selector switch incoming,
wires duly socket crimped, main contactor & overload relay,
start-stop push buttons, to be erected on angle iron frame
grouted on wall as directed. The isolator, overload relay &
contactors will be of L&T, Seimens or BCH make only (a)
DOL upto 7.50 H.P.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
100 Supplying and erecting XLPE (IS:7098) (I)-88 ISI 250.00 Rmt 136.35
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size. (E) 3 core 2.5 Sq. mm
101 Providing laying and jointing in true line and level 50mm 150.00 Rmt 195.67
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
102 Providing and fixing butterfly valve of IS approved brand 2.00 Nos. 1595.80
103 Excavation for foundation for depth from 1.5 m to 3.0 m 23.00 Cum 300.80
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead. (D)
Soft rock not requiring Blasting
104 Providing 10mm thick cement mala plaster in single coat on 19.00 Sqmt 215.30
brick/concrete walls for interior plastering and finished even
and smooth fininshing with a floating coat of neat cement
slurry in (i)Cement mortar 1:3 (1-cement:3-sand). Complete
upto floor two level.
105 Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. 7.00 Nos 958.17
size having weight not less than 35Kg.
106 Clearing and grubbing road land including uprooting rank 1.10 Hectare 28455.10
vegetation grass bushes, shrubs, sapling and trees girth up to
300 mm removal of stumps of trees cut earlier and disposal
of unserviceable materials (C) By mechanical means in area
of light jungle
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
107 Earthwork in cuting in all sorts of soil and soft murrum 1097.00 Cum 134.20
including conveying and spreading the stuff, embankment as
and where directed within 200meters from the end of the
cutting with all required lead and lift.
108 Earthwork in cutting including preparing the slope and 2194.00 Cum 260.57
camber and stacking or utilising the cutting stuff in bank as
directed upto 200 Meters from the end of cutting with all
lead and lift.(i) Hard murrum.
109 Earthwork in cutting including preparing the slope and 8773.00 Cum 316.60
camber andstacking or utilising the cutting stuff in bank as
directed upto 200 Meters from the end of cutting with all
lead and lift.(ii) Soft rock not requiring blasting.
110 Earthwork in cutting including preparing the slope and 9870.00 Cum 670.97
camber andstacking or utilising the cutting stuff in bank as
directed upto 200 Meters from the end of cutting with all
lead and lift.(iii) Hard rock.
111 Conveying and utilising the stuff in bank from end of cutting 6909.00 Cum 129.28
with all required lead and lift.(C) Above 400 Meters upto
112 Earthwork for embankment including breaking clods, 1262.00 Cum 131.93
dressing with all lead and lift (including watering and
consolidation)(A) From Borrow pits within land width
113 Rolling and consolidation of soling including filling in 4255.00 Sqmt. 22.75
depression which occur during the process, with power roler
8 tonne to 12 tonne..
114 Providing uncoursed rubble stone masonry in Cement 55.00 Cum 2294.12
Mortar 1:5 for flooring including curring pointing in Cement
Mortar 1:3 on exposed faces complete.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
115 Box cutting the road surface to proper slope and camber for 397.00 Cum 109.05
making a base for road work including removing the
excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
116 Construction of B.I.T.C. granular sub base by providing 159.00 Cum 1620.86
granular material of Grading II, spreading in uniform layers
with motor grader on prepared surface , mixing by mix in
place method with front end loader at OMC , and
compacting with vibratory roller to achieve the desired
density ,complete as per Clause
117 Providing, laying, spreading and compacting stone 116.00 Cum 2122.90
aggregates of specific sizes to water bound macadam (Grade-
II) (B.T. Metal of size 45 to 63 mm) specification including
spreading in uniform thickness, hand packing, rolling with
wheeled steel/ vibratory roller in stages to proper grade and
camber, applying and brooming requisite type of screening/
binding Materials to fill up the interstices of coarse
aggregate, watering and compacting to the required density.
118 Compaction and finishing of cement concrete road by trimix 684.00 Sqmt. 72.72
process providing extra labour charges for the trimix vaccum
dewatering service process on cement concrete road surface
by using vaccum dewatering pump floater surface vibrator
including making rough finish to surface as per in including
levelling the complete.
119 Supplying and fixing reinforced concrete heavy duty non- 30.00 Rmt. 660.00
pressure pipes with collars for culverts carrying heavy traffic
as per IS 458-1991 specifications including setting the pipes
in C.M. 1:2 watering and laying (to level or slopes) of class
NP3 of following internal daimeters.(i) 300mm dia.
120 Construction of Cattle trap made from ISMC 100 border and 6.00 Sqmt. 6146.86
G.I. pipe 50 mm dia. Heavy duty at 12cm spacing by
welding and for supports 2 nos. I.S.M.C. 100x75x6 section
fixing in prepared chamber as per drawing.
121 Constructing Brick masonry road gully chamber 500mm x 12.00 Nos. 2017.20
450mm x 600mm including 500mm x 450mm C.I.
horizontal grating wih frame complete.
122 Supplying of yellow or Goradu soil with all lead and lift 864.00 Cum 505.00
including spreading watering dressing and rolling with hand
roller etc complete selected soil
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
123 Supplying of well rotted FYM manure with all lead and lift 44.00 Cum 378.75
including spreading mixing dressing and rolling with hand
roller etc. complete
124 Scarifying the surface of soil including spreading of DAP 438.00 Sqmt. 26.26
fertilizer mixing with soil properly leveling ground dressing
125 Supplying and planting Dibbling semi carpet lawn at 438.00 Sqmt. 90.90
distance of about 15 cm x 15 cm after proper anti termite
treatment and rolling the same by hand roller and watering
126 Bowling and developing flowering plants grown in nursery 50.00 Nos. 505.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Bottom Palm
127 Bowling and developing flowering plants grown in nursery 50.00 Nos. 656.50
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Triangle Palm
128 Bowling and developing flowering plants grown in nursery 35.00 Nos. 80.80
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Jasud
129 Bowling and developing flowering plants grown in nursery 50.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Croton
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
130 Bowling and developing flowering plants grown in nursery 50.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton
131 Bowling and developing flowering plants grown in nursery 50.00 Nos. 70.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra
132 Bowling and developing flowering plants grown in nursery 45.00 Nos. 40.40
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Croton Petra Live Plant
133 Bowling and developing flowering plants grown in nursery 40.00 Nos. 101.00
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Golden Durenta Varigated
134 Bowling and developing flowering plants grown in nursery 45.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Crotons Variety
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
135 Bowling and developing flowering plants grown in nursery 500.00 Nos. 35.35
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahindi
136 Bowling and developing flowering plants grown in nursery 30.00 Nos. 85.85
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Varigated Ficus
137 Bowling and developing flowering plants grown in nursery 29.00 Nos. 70.70
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted New Black Ficus
138 Bowling and developing flowering plants grown in nursery 500.00 Nos. 45.45
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted White Ribbon Plants
139 Bowling and developing flowering plants grown in nursery 500.00 Nos. 60.60
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Green Mahendi border
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
140 Bowling and developing flowering plants grown in nursery 50.00 Nos. 95.95
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Pendulla Asopalav
141 Bowling and developing flowering plants grown in nursery 100.00 Nos. 121.20
having approximate height 4 to 5 t or Height as per
Landscape Plan with natural growth and natural colour
planted in a lump of soil packed in polyethylene bag or
earthen pot including organic & chemical fertilizer
pesticides, fungicides, hormones & maintaining the plants
up to three months as Deserted Potted Plants
142 Labour charges for planting various plantsafler proper anti- 2124.00 Nos. 70.70
termite treatment in pits including placing properly and
filling the pits with required prepared mix soil and watering
and dispporting etc. complete
143 Maintance of the garden for 60 days after Complition of 3 1.00 Job 25250.00
month stipulated period is completed for plantation of lawn
and plants including applying second round of proper anti-
termite treatment
144 Providing laying and jointing in true line and level 40mm 60.00 Rmt 148.12
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
145 Providing and fixing brass screw down stop tap.(A) 15mm 10.00 Nos. 205.83
146 Rubber Hose Pipe 15 mm dia of approved brand and make 100.00 Rmt 90.90
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
147 Providing and fixing G.I. Nipple as directed 20.00 Nos. 50.50
148 Excavation for foundation upto 1.5 m depth including 25.00 Cum 157.08
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(B) Dense or
149 Providing & Laying Rain Water Junction Chamber of Clear 15.00 Nos. 6526.62
Internal Size 0.60 x 0.60 x 0.75m with excavation of size
1.36 x 1.36m & 0.15m thick M200 Bed Concrete Including
brick masonary 0.23 thick wall in C.M. 1:6 of 0.75m height
with 15mm thick Cement Plaster inside & outside (1:4),
1.06 x 1.06 RCC M200 top slab of thickness 0.15m with
TMT steel and 455mm x 610mm cast iron manhole cover
with frame weight not less than 35 kg as per directed by
Engineer-in-charge.
150 Providing & Laying Filter chamber of brickwork 0.23 thick 15.00 Nos. 23208.79
in C.M. 1:6 of clear internal size 2.04m x 1.20m x 1.20m
and excavation dimension of 2.80m x 1.96m x 1.35m
including C.C. M200 Bed Concrete 0.15m thick and RCC
M200 Top slab of thickness 0.15m with TMT steel,
Including 15mm (1:4) thick cement plaster inside & outside
with Cement slurry & top cover with frame of minimum
weight of 35kg, including filling filter material of 200mm
thick each layer of 25-40mm, 10-20mm of BT metal and
sand as per directed by engineer-in-charge
151 Providing & Laying Water Harvesting Pit of clear size 2.00 1.00 Nos. 35169.21
mt x 2.00 mt x 4.00 mt. For water logging with excavation
in any strata upto four meter depth, Brick work 0.23 thick in
C.M. 1:6 of clear internal size 2.00m x 2.00m x 1.20m with
15mm thick C.M. 1:4 plaster, filling the pit with B.T. metal
40mm in 0.60 mt. depth with 25-40mm kaptchi, 0.30 mt.
depth and 2mt. depth with coarse sand in layers including
makng P.V.C. line for water inlet etc. as directed with
250mm dia bore 15mt. depth amd 150mm dia PVC pipe of
10 Kg.f/cm2 casing wih gravel packing or as directed.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
152 A Pump Room. Supply & fixing Diesel engine driven min. 1.00 Nos. 555500.00
pump of S5 mt. head and 137 M3/ Hr. capacity with
RPM diesel engine with battery charger. Base plate, AVM
pad etc. complete as directed including necessary concrete
platform as directed. (Make:-L)
153 Fire Pumps & Accessories, Yard Hydrant, Internal Hydrant, 1.00 Nos. 153924.00
Hose Reel & Sprinkler System Supply, Installation, Testing
& Commisioning of Main Fire Pump Of Capacity 20 H.P.
with 55 mtr. Head, Pump
154 Supply, Installation, Testing & Commisioning of control 1.00 Nos. 90900.00
Panel suitable for automatic operation of fire fighting pumps
consisting (a) Necessary cabling, wiring, earthing from panel
to individual equipment shall be included in the quoted
price. (b) Facility for more selection i.e. auto or manual. (c)
Protection failure and control cabling. (d) Interlocking of
pressure switch with pumps.
155 Supply, Installation, Testing & Commisioning of 150mm 1.00 Nos. 3535.00
dia. Pressure Gauge of range 0 - 15 kg/cm3 confirming to as
per specification complete as required.
156 Supply, Installation, Testing & Commisioning of Pressure 1.00 Nos. 4545.00
Switches for automation of fire pumps, Pressure switches
shall be double pole, single throw type suitable for 3 phase
supply with diaphragm. Alluminium Enclosure with IP
protection as required.
157 Supply, Installation, Testing & Commisioning of the 40.00 meter 2390.67
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.a) 150 mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
158 Supply, Installation, Testing & Commisioning of the 45.00 meter 1711.95
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. b) 100 mm dia.
159 Supply, Installation, Testing & Commisioning of the 10.00 meter 1277.65
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.c) 80 mm dia.
160 Supply, Installation, Testing & Commisioning of the 50.00 meter 1100.90
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required. d) 65 mm dia.
161 Supply, Installation, Testing & Commisioning of the 45.00 meter 989.80
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.e) 50 mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
162 Supply, Installation, Testing & Commisioning of the 40.00 meter 858.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.f) 32 mm dia.
163 Supply, Installation, Testing & Commisioning of the 150.00 meter 555.50
following sizes of flanges jointed / screwed / welded, M.S.
Pipes of Class C ISI marked including accessories such as
MS bracket, U clamps with Anchor Fasteners, tees / elbows
/ reducers / couplings / unions / bends / flanges etc. and
laying on the surface including painting with two coats of
anticorrosive primer and two coats of approved red enamel
paint after laying and testing after installation etc. as per
specifications complete as required.g) 25 mm dia.
164 Supply, Installation, Testing & Commisioning of C.I. 1.00 Nos. 9738.42
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required.a) 150 mm dia.
165 Supply, Installation, Testing & Commisioning of C.I. 2.00 Nos. 8932.44
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required.b) 100 mm dia.
166 Supply, Installation, Testing & Commisioning of C.I. 2.00 Nos. 5555.00
Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets
complete as required.d) 50 mm dia.
167 Supply, Installation, Testing & Commisioning of Cast iron 1.00 Nos. 9090.00
Dual plate Check valve (PN 1.6)a) 150 mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
168 Supply, Installation, Testing & Commisioning of Cast iron 2.00 Nos. 7564.90
Dual plate Check valve (PN 1.6)b) 100 mm dia.
169 Supply, Installation, Testing & Commisioning S.S. Single 3.00 Nos. 5656.00
Headed Fire Hydrant Valve with 80mm N.B. Flanged inlet,
63 mm dia. Female instantaneous outlet type S.S. coupling,
blank cap, chain, twist release type lug & all accessories
Confirming to IS:5290. Including fixing with supports,
flanged tapping from wet riser, orifice plate.
170 Supply, Installation, Testing & Commisioning of Weather 2.00 Nos. 4595.50
proof standard M.S. Fire Hose Cabinet wall mounting type
(450mm x 450mm x 250mm deep) having single or double
opening with necessary locking arrangement by allan key
suitable for housing 1 nos. hose pipe, 1 nos. Branch pipe &
nozzle spanner.
171 Supply, Installation, Testing & Commisioning non 2.00 Nos. 5641.86
percolating rubber reinforced lined Fire Hose pipe (as per
IS:636) of 63mm dia and 15 mtr. Long. The hose shall be
rated for burst pressure pf 35.7kg/sqcm. Hose shall be
complete with ISI marked SS male & female coupling
(IS:903) bound & riveted to hose pipe with copper rivets &
1.5mm copper wire.
172 Supply, Installation, Testing & Commisioning of 63mm dia. 2.00 Nos. 5641.86
Instantaneous pattern SS 304, short branch pipe, 20mm dia
nozzle confirming to IS
173 Supply, Installation, Testing & Commisioning of First Aid 2.00 Nos. 6565.00
Hose Reel equipment conforming to 15:884 comprising of
hose reel drum, 8 mm shut off noz:z.le, Ru bber hose of
mm dia x 30 mtr. long, painting, swinging type fixing
bracket, anchor fastener, bolts & nuts etc.
174 Supply, Installation, Testing & Commisioning of SS Ball 2.00 Nos. 858.50
Valve. A) 25mm dia.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
175 Supply, Installation, Testing & Commisioning of Cast Iron 2 1.00 Nos. 8585.00
Way Fire Brigade Inlet as per 1S: 904 having 63 mm dia
in/et with blank cap and chain with necessary fit ti ngs,
flanges, nut bolts etc. complete as required. (For Hydrant
176 Supply, Installation, Testing & Commisioning of Gun Metal 1.00 Nos. 959.50
Air Release Valve with necessary fittings. Size: 25mm (For
177 Supply, Installation, Testing & Commisioning of Quartzoid 30.00 Nos. 454.50
Bulb type Sprinkler Heads. A) Pendent Sprinkler 57°C
178 Fire Alarm System Alarm panel Microprocessor based 8 1.00 Nos. 16665.00
179 Manual Call Point 3.00 Nos. 454.50
180 2 core x 1.5 sqmm wire with pvc conduct and required 250.00 Rmt. 166.65
181 Smoke Detector 30.00 Nos. 1565.50
182 II) Fire Extinguisher and Exit Signages Supply, installlation, 10.00 Nos. 6447.84
testing and commissioning of Carbon Dioxide (CO2) type
Fire Extinguisher of 4.5 kg confirm to IS:15683, with ISI
marked / TAC approved fitted with required accessories
including wall suspension brakets.
183 Supply, Installation, Testing & Commisioning of ABC type 10.00 Nos. 2222.00
6kg confirm IS:15683, with ISI marked / TAC approved
fitted with required accessories including wall suspension
184 Signage Boards 25.00 Nos. 252.50
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
185 Providing and laying controlled cement concrete M.200 and 1.00 Cum 6087.11
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in Beams upto floor two level.
186 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 5.00 Sqmt 1311.18
mm (average) base of cement mortar 1:6 ( 1 cement:
coarse sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including
finised with flush pointing & cleaning the surface etc.
complete for light shade
187 Providing and fixing window having extruded aluminum 4.00 Sqmt 1713.70
Colour anodized section frame main outer size 63.50 x
38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two
track member size 61.85 mm x 31.75 mm x 1.20mm @
wt.of 0.695 Kg/mt, vertical member of size 61.85 mm x
31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x
1.29mm @ wt.of 0.456Kg/mt, vertical member of size
0.457 Kg/mt with 5 mm thick transparent bronze colour
tinted float glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass fixing to frame
as per details etc complete for window.
188 Excavation for foundation upto 1.5 m depth including 60.00 Cum 532.91
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(D)
Soft rock not requiring Blasting
189 Excavation for foundation for depth from 1.5 m to 3.0 m 20.00 Cum 555.49
including sorting out and stacking of useful materials
and disposing off the excavated stuff upto 50 Meter
lead. (D) Soft rock not requiring Blasting
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
190 Providing and laying cement concrete 1:5:10 (1- Cement : 5- 4.00 Cum 2566.77
fine sand : 10- graded brick bat aggregates 40mm nominal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
191 Half brick masonry in common brunt clay building bricks 22.00 Sqmt. 618.79
having crushing strength not less than 35 Kg/Sq.Cm. in
Cement mortar 1:5 (1- Cement : 5 -coarse sand ) in
foundation and plinth (B) Conventional
192 Providing and laying cement concrete flooring 1:2:4 (1- 30.00 Sqmt. 352.01
cement : 2-coarse sand : 4-graded stone aggregate 20mm
nominal size) laid in one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
193 Providing and Laying ordinary cement concrete 1:2:4 (1- 5.00 Cum 6888.15
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) and finishing smooth with curing etc.
complete including the cost of formwork but excluding the
cost of reinforsement for R.C.C work in (iii) Slabs having
more than 10 cm and upto 13 cm. thickness
194 Providing and laying (to level or slopes) and jointing with 15.00 Rmt 317.48
stiff mixture of Cement Mortar in proportion 1:1 Salt glazed
stoneware pipes including testing of pipes and joints
complete.(B) 150mm dia.
195 Providing and Constructing sock pit of 2.46 mt. dia outside 3.00 Nos 40244.46
and 4 mt depth with honey combed masonary 6.50 mt. from
bottom and 0.60 mt. brick masonary in C.M. 1:6 top with
RCC slab cover of M200 vent pipe 1.8mt. Long 75mm dia
& C.I. cover and cowel vent etc. comp
196 Demarkation of road alingment including marking out road 0.10 Km 2706.50
line by providing and fixing wooden pegs or steel rod of
required size at every 25 M to 50 M. including excavating
trenches ion both sodes of 0.30 m. x 0.30M. including
supplying of labours and all materials for every work etc.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
197 Providing flood gauge marks on substructure as per design 4.41 Rmt. 165.69
including painting complete.
198 Providing and laying - Fitter Media 600mm thick directed at 393.00 Sq.m. 1238.93
the back of abutments,returns and wing walls as per detailed
specifications.
199 Providing and laying boulders apron on river bed for 166.40 Cum. 1083.81
protection against scour with stone boulders weighing not
less than 40 kg each complete as per drawing and Technical
200 Providing and laying Pitching on slopes laid over prepared 444.90 Cu.m. 1051.41
filter media including boulder apron laid dry in front of toe
of embankment complete as per drawing and Technical
201 Providing & laying filter material underneath pitching in 46.50 cum 877.69
slope complete as per drawing and technical specification
202 Excavation for foundation in sand, gravel, clay soft soils and 453.00 cum 511.45
murrum etc. including shoring, strutting dewatering as
necessary and disposing of the excavated stuff as
directed.(A) Depth upto 3.0 M. and lead upto 100m for
203 Excavation in large boulders and soft rock by welding 647.70 Cu.m. 717.23
including shoring, strutting and dewatering as necessary and
disposing of the excavated stuff as directed.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
204 Providing and filling in foundation with ordinary Cement 37.70 Cu.m. 3615.61
concrete M-150 mix and providing necessary vertical pin
headers including formwork, vibrating, ramming and curing
205 Providing and Casting in situ controlled Cement Concrete M- 35.60 Cu.m. 4659.10
250 for R.C.C. Raft and cutt-off walls including necessary
shuttering laying, vibrating, ramming and curing complete.
206 Providing and Casting in situ controlled Cement Concrete M- 150.40 Cu.m. 4659.10
30 for R.C.C. Raft and cutt-off walls including necessary
shuttering laying, vibrating, ramming and curing complete.
207 Gabian Structure for Retaining Earth (Providing and 190.00 Cu.m. 1560.45
construction of a gabain structure for retaining earth with
segments of wire crates of size 7 m x 3 m x 0.6 m each
divided into 1.5 m compartments by cross netting, made
from 4 mm galvanised steel wire @ 32 kg per 10 sqm
having minimum tensile strength of 300 Mpa conforming to
IS:280 and galvanizing coating conforming to IS:4826,
woven into mesh with double twist, mesh size not
exceeding 100 x 100 mm, filled with boulders with least
dimension of 200 mm, all loose ends to be tied with 4 mm
galvanised steel wire)
208 Laying of a geotextile filter between pitching and 120.00 Sq.m 753.46
embankment slopes on which pitching is laid to prevent
escape of the embankment material through the voids of the
stone pitching/cement concrete blocks as well as to allow
free movement of water without creating any uplift head on
209 Providing and casting in situ controlled cement concrete M- 214.70 Cu.m. 5266.33
250 for R.C.C. return as per drawings including centering
shuttering, scaffolding where necessary, laying vibrating,
curing and finishing complete.(A) Height from 0.0 to 5.0 M.
(1) Piers (2) Abutment (3) RCC return
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
210 Providing and casting in situ controlled cement concrete M- 12.00 Cu.m. 5433.93
250 for R.C.C. return as per drawings including centering
shuttering, scaffolding where necessary, laying vibrating,
curing and finishing complete.(A) Height from 5.0 to
M. (1) Piers (2) Abutment (3) RCC return
211 Providing sand filling behind abutment and between return 683.40 Cum 479.44
wall in layers as directed
212 Providing and casting in situ controlled cement concrete M- 34.30 Cum. 5397.06
250 for R.C.C. solid slab including centering, scaffolding,
curing and finishing complete.
213 Drainage spouts complete as per drawing and technical 10.00 No. 536.03
specifications Clause
214 Providing and fixing 'W' type safety barrier using M.S. iron 80.00 Rmt 3388.00
channel 150mm x 75m x 5mm size erected at 2.0 Mt. center
to center and providing 'W' shaped galvanised steel sheet
guard rail 3mm thick for crash barrier in single row as per
detailed drawing with fabrication and installation charges
including providing foundation block of size 0.60 x 0.60 x
0.75 Mt. in C.C. 1:2:4 and oil painting two coats with one
coat of red oxide etc complete.
215 Earthwork for embankment including breaking clods, 127.20 Cum 211.82
dressing with all lead and lift (excluding watering and
consolidation)(E) From Borrow area within 3.0 Km. lead
(more than 10 ton)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
216 Point wiring for Light / Bell with 2-1.5 sq.mm & earth 399.00 Pts 485.81
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.(f) with
medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete.Cat-III (Make:-
Honeywell, L&T, Havells, Indoasian, Legrand)
217 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 157.00 Pts 674.68
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type
switch and hum free EME step type electronic fan regulator
mounted and accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box, single
mounting base frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose / H.D.Connector as
directed..(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete.Cat-
III (Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
219 Point wiring for Individual Plug with & earth wire of 1.5 88.00 Pts 510.05
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories. [I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board (f) with medium class Rigid PVC
pipe and accessories erected concealed in wall/ceiling
completeCat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
220 Point wiring for on board Looped Plug with 6A Modular 158.00 Pts 257.55
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories.Cat-III
(Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
221 Providing following type of Modular Type Accessories 3.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (3) Two Pin/RJ-11
Telephone Socket[A] For One Gang Cat.III (Make:-
Honeywell, L&T, Havells, Indoasian, Legrand)
222 Providing following type of Modular Type Accessories 3.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (4) TV Co-axial
Socket outlet Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
223 Providing following type of Modular Type Accessories 158.00 Nos. 25.25
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (7) Blank Plate
Single Cat.III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
224 Providing following type of Modular Type Accessories 33.00 Nos. 160.59
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (8) Computer RJ-
45 socket Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
225 Providing following type of Modular Type Accessories 61.00 Nos. 180.79
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (9) 16 Amp. SP one
way switch Cat-III (Make:- Honeywell, L&T, Havells,
Indoasian, Legrand)
226 Providing following type of Modular Type Accessories 61.00 Nos. 199.98
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (10) 6/16Amp.
Universal socket Cat-III (Make:- Honeywell, L&T,
Havells, Indoasian, Legrand)
227 Providing following type of Modular Type Accessories 16.00 Nos. 604.99
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate
, modules erected with necessary connections as per site
situation directed by Engineer In charge. (21) Foot Light as
per colour requirement with concealed box, modular
accessories, acrylic glass cover with suitable LED watt with
all accessories as per following module (c) Six modules
Cat-III (Make:- Honeywell, L&T, Havells, Indoasian,
228 Providing and erecting ISI mark Medium class RIGID PVC 0.00 0.00 0.00
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed
229 Providing and erecting ISI mark Medium class RIGID PVC 1260.00 Mtrs. 33.33
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b) 25 mm
230 Providing and erecting ISI mark Medium class RIGID PVC 160.00 Mtrs. 54.54
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (c) 32 mm
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
231 Providing & erecting PVC Corrugated Flexible Conduit with 240.00 Mtrs. 21.21
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes.(2) 25 mm
232 Providing & erecting PVC Corrugated Flexible Conduit with 120.00 Mtrs. 27.27
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. (3) 32 mm
233 Supplying and laying UPVC cable trunking system 25.00 Mtrs. 428.24
comprising unplasticised polyvinyl, chloride rigid material
with ignition free and flame proof confirming BS with
necessary end caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories and measuring of
following sizes (2) 100 mm x 50 mm trunking
234 Providing and erecting Mains with 1.1 KV grade FRLS PVC 5166.00 Mtrs. 82.82
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected concealed in /flushed
on wall/ceiling, with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth
continuity of following size (A) with medium class Rigid
PVC pipe and accessories (b) 2 wire 2.5 sq. mm (Make: -RR
Kabel, Havells, Avocab, KEI,Johnson)
235 Providing and erecting Mains with 1.1 KV grade FRLS PVC 2256.00 Mtrs. 112.11
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (a) 2 wire 4 sq. mm (Make: -RR Kabel, Havells,
Avocab, KEI,Johnson)
236 Providing and erecting Mains with 1.1 KV grade FRLS PVC 630.00 Mtrs. 425.21
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm ) (Make: -RR Kabel, Havells,
Avocab, KEI,Johnson)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
238 providing and erecting Mains with ISI marked, 1.5KV grade 150.00 Mtrs. 91.91
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required. (f) One wire 10.00 sq. mm
239 providing and erecting Mains with ISI marked, 1.5KV grade 30.00 Mtrs. 300.98
electrolyte multi stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required. (i) One wire 35.00 sq. mm
240 Supplying and erecting Flexible PVC insulated multi strand 278.00 Mtrs. 22.22
multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed. (c) 1.00 Sq.mm
core round/ flat PVC sheathed
241 Supplying and erecting Flexible PVC insulated multi strand 180.00 Mtrs. 46.46
multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed.e) 1.50 Sq.mm
core round PVC sheathed
242 Providing & Erecting approved make following size of TV 135.00 Mtrs. 62.62
Co-axial flexible cable comprising inner conductor of solid
bare copper insulated with Foam PE & Secondary conductor
made of poly - Aluminium film bonded Al. Braids @
suitable coverage overall sheathed with black PVC
insulation. e).RG-11
243 Supplying & erecting approved make Telephone Cable 75.00 Mtrs. 20.20
electrolytic copper conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in existing pipe. of
following size of conductors & nos.of pairs. With necessary
connections. [A] Conductor Size 0.5 mm (a) Unarmoured
244 Supplying & erecting approved make LAN cable of 1056.00 Mtrs. 47.47
following size in existing pipe as per direction [C] CAT -
245 Providing & erecting main Distribution (MDF) indoor type, 4.00 Nos. 994.85
back mounted frame as per DoT standard approved with
krone strips (a) Suitable for 10 pair
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
246 Supplying & erecting M.S. Box having 16 Gauge painted 14.00 Nos. 88.88
with red oxide or Heavy duty PVC box erected flushed on
wall or concealed in wall with necessary plastering &
finishing as directed of following size. (c) 200 mm x
247 Providing & erecting Switch board for Computer or electric 33.00 Nos. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with
single mounting base frame covered with textured/metallic
/white front plate,modules erected with necessary
connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories.Cat-
III (Make:- Honeywell, L&T, Havells, Indoasian, Legrand)
248 Decorative call bell Ting-tong box type 250 volts complete 1.00 Nos. 71.71
249 Supplying and erecting LED indoor fittings with LEDs of 313.00 Nos. 373.70
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)(A) Tube Light with
integral/ non-integral driver . (iv) 22-24 Watts, Surge -
2KV,IP-20, conventional 4 feet Cat III (Make:- Wipro,
LT,Philiphs,Havells,Jaquar)
250 Supplying and erecting led lamps with following wattage 45.00 Nos. 112.11
capacity of 220 to 240 voltage, minimum 15000 burning
hours life, 500 V in built-surge protection,Polycarbonate
diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5 (A) LED Lamps integral type, with PC
diffuser suitable LAMP holder (i) 5 to 8 watts Cat-III
(Make:- Wipro, LT,Philiphs,Havells,Jaquar)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
251 Supplying and erecting LED street light / Flood light fittings 20.00 Nos. 4997.48
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection.(ii) above 48 to 60 Watts Cat-III (Make:- Wipro,
LT,Philiphs,Havells,Jaquar)
252 Supplying and erecting LED street light / Flood light fittings 10.00 Nos. 8453.70
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection.(v) above 120 to 160 watts Cat-III (Make:-
Wipro, LT,Philiphs,Havells,Jaquar)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
253 Supplying and erecting LED street light / Flood light fittings 2.00 Nos. 4819.72
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting
driver and accessories wired upto terminal block.IP 65 (ii)32-
40W Cat-III (Make:- Wipro, LT,Philiphs,Havells,Jaquar)
254 Providing and erecting Approved make Four pole moulded 25.00 Nos. 6173.12
case circuit breaker having breaking capacity ICU of 25 KA.
at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
255 Providing and erecting Approved make Four pole moulded 5.00 Nos. 8055.76
case circuit breaker having breaking capacity ICU of 35 KA.
at 415 V. having normal current rating 125A. with Fixed
thermal & magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader tinned copper
& complete erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III (Make:- Indoasian,
L&T (LK), ABB, Schneider)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
256 Providing and erecting Approved make Four pole moulded 2.00 Nos. 20946.39
case circuit breaker having breaking capacity ICU of 35 KA.
and above at 415 V . having normal current rating 250A.
with variable thermal & magnetic release suitable to work
on A.C.supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
257 Providing and erecting Approved make Four pole moulded 1.00 Nos. 25228.79
case circuit breaker having breaking capacity ICU of 50 KA
and above at 415 V having Normal current rating 400A.
with variable Thermal & magnetic release suitable to work
on A.C.supply 50 c/s. With all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
258 Supplying & erecting approved make Four Pole 415V 1.00 Nos. 22255.35
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
(F)400A (Make:- Indoasian, L&T (LK), ABB, Schneider)
259 Providing and erecting Approved make Earth fault Relay 1.00 Nos. 5415.62
suitable to mount with inter connection suitable to
following size of moulded case circuit breaker having CT
ratio & MCCB rating as following along with shunt trip
220V AC. with all internal connections & complete erected
in existing M.S.housing. (3) 250 A -400 A , CT Ratio 1/400
260 Supplying and erecting triple pole & neutral 440V / 500V 12.00 Rn.Mtrs 1961.42
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
261 Supplying and erecting triple pole & neutral 440V / 500V 9.00 Rn.Mtrs 3202.71
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (B) Suitable for 200 Amp. capacity
262 Supplying and erecting triple pole & neutral 440V / 500V 2.00 Rn.Mtrs 7319.47
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary
connections. (D) Suitable for 400 Amp. capacity
263 providing and erecting Miniature circuit breaker single pole 32.00 Nos. 270.68
0.5A to 2A system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat.III (Make:- Indoasian, L&T (LK), ABB,
264 Providing and erecting Miniature circuit breaker single pole 168.00 Nos. 112.11
6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat-III
(Make:- Indoasian, L&T (LK), ABB, Schneider)
265 Providing & erecting 240 V MCB double pole switch for 6.00 Nos. 295.93
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following
capacity (B) 40 Amp. Cat-III (Make:- Indoasian, L&T
(LK), ABB, Schneider)
266 Providing & erecting 415 V MCB Four Pole for Motor & 16.00 Nos. 737.30
Inductive Load (C Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box having following
capacity (B.) for 63 Amp. Cat-III (Make:- Indoasian,
L&T (LK), ABB, Schneider)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
267 Providing and erecting Sheet Steel powder coated MCB 14.00 Nos. 2913.85
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (B) three phase
incoming and single phase horizontal type outgoing Per
phase isolation type (PPI) (b) sheet steel double door (ii)6
way (Make:- Indoasian, L&T (LK), ABB, Schneider)
268 Providing and erecting Approved make RCCBs conforming 42.00 Nos. 2235.13
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having characteristic
of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max.
rating erected as directed (iI) 40 Amps.DP Cat. III (Make:-
Indoasian, L&T (LK), ABB, Schneider)
269 Providing and erecting metallic vitrified danger notice board 5.00 Nos. 69.69
as per language suggested by engineer incharge for
MEDIUM VOLTAGE installation to be erected as per IS-
270 Providing and erecting Annealed bare Copper wire 8 to 16 30.00 Kgs. 794.87
271 Providing and erecting Pipe type earthing having 150 20.00 Nos. 368.65
cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
272 For using salt and charcoal / coke as required for pipe type 20.00 Nos. 171.70
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
273 Supplying & erecting earth pit of minimum bore dia.150mm 5.00 Nos. 4591.46
size approved make Earthing Electrode consisting Pipe-in-
Pipe Technology as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising, connection terminal dia
of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable
for following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation
duly stamped and signed by agency and officer Incharge has
to ensure the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must be
submitted by Agency. (a) For Electrical Installation up to
440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
274 Providing & erecting weather proof, dust & vermin proof, 9.00 Sq.Mtrs. 14902.55
floor mounted front operated indoor type cubical panel
board necessary IP-42 and above protection as per approval
from engineer incharge made from 14 SWG thick CRC M.S.
sheet for outer body & doors, 16 SWG thick CRC M.S.sheet
for internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with
erection of supplied switch gears, BUSBARS, suitable size
of inter connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber gasket,heavy
duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating. (The rates excludes the
cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension
shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with
following size. (B) The standard companies switch gear
shall be used and only manufacturers at CPRI approved
factory (i) with 350mm depth
275 Providing , erecting , fabricating the M.S. structure as per 140.00 Kgs. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete
with cutting, welding, grinding & finishing duly painted
with one coat of red oxide with erection on site as per
direction of engineer in charge with necessary grouting,
cementing, plastering & finishing complete.
276 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 190.00 Mtrs. 220.18
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (B) 3 1/2 core 35 Sq. mm (
16 Sq. mm 1/2 core) (Make: -RR Kabel, Havells, Avocab,
277 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 120.00 Mtrs. 490.86
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (E) 3 1/2 core 95 Sq. mm (
50 Sq. mm 1/2 core) (Make: -RR Kabel, Havells, Avocab,
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
278 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 360.00 Mtrs. 904.96
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (H) 3 1/2 core 185 Sq. mm
( 95 Sq. mm 1/2 core) (Make: -RR Kabel, Havells,
Avocab, KEI,Johnson)
279 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 230.00 Mtrs. 117.16
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (A) 4 core 4 Sq.
mm (Make: -RR Kabel, Havells, Avocab, KEI,Johnson)
280 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 550.00 Mtrs. 140.39
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (C) 4 core 10 Sq.
mm (Make: -RR Kabel, Havells, Avocab, KEI,Johnson)
281 Making trench in soft soil of suitable width of 90 cm deep 455.00 Mtrs. 55.55
for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal
282 Making trench in Hard Murrum / Tar Road of suitable width 227.50 Mtrs. 74.74
of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
283 Making trench in Hard Murrum / Tar Road of suitable width 91.00 Mtrs. 357.54
of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground. (B) If additional
machinery like hammer driller or JCB use [Add]
284 Providing & laying. R.C.C. Hume pipe for cable to be laid 60.00 Mtrs. 263.61
90 cm. below ground across the road crossing or on floor
with necessary material in an approved manner and making
the ground as per original. (E)150 mm dia
285 Providing & laying approved make Double walled 824.50 Mtrs. 62.62
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable (A)
50 mm Outer Dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
286 Providing & laying approved make Double walled 306.00 Mtrs. 137.36
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable (D)
120 mm Outer Dia
287 Providing & laying approved make ISI marked Rigid PVC 50.00 Mtrs. 236.34
pipe having 6Kg / cm2 (Class-3) to be erected at road
crossing on or floor as directed for laying of cable. The pipes
as following size of dia & weight per 6 mtr. (F) 110 mm
inner Dia. (11.63 Kg/6 RMT)
288 Providing and, fixing heavy duty flange type brass cable 20.00 Nos. 33.33
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (A) 2 to 4 core 2.5 / 4 Sq. mm
289 Providing and, fixing heavy duty flange type brass cable 44.00 Nos. 38.38
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (C) 2 to 4 core 10 Sq. mm
290 Providing and, fixing heavy duty flange type brass double 8.00 Nos. 75.75
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (B) 3 & 1/2
core 35/50 Sq. mm
291 Providing and, fixing heavy duty flange type brass double 8.00 Nos. 131.30
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (D) 3 & 1/2
292 Providing and, fixing heavy duty flange type brass double 2.00 Nos. 238.36
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.(G) 3 & 1/2
core 185 Sq. mm
293 Solder less crimping type Aluminium lugs conforming to IS 80.00 Nos. 6.06
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (A)
294 Solder less crimping type Aluminium lugs conforming to IS 176.00 Nos. 13.13
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (B)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
295 Solder less crimping type Aluminium lugs conforming to IS 32.00 Nos. 20.20
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (D)
296 Solder less crimping type Aluminium lugs conforming to IS 32.00 Nos. 40.40
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (F)
297 Solder less crimping type Aluminium lugs conforming to IS 8.00 Nos. 80.80
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. ( I )
298 Providing and erecting Approved make Ceiling fan with 157.00 Nos. 1596.81
double ball bearing ISI mark with condenser A.C. 23OV.50
c/s.1200 mm. sweep complete, canopy erected on existing
hook or clamp with earthing. [Make shall be approved by
Engineer in charge] (Make:- Crompton, Havells, Orient)
299 Supplying and erecting 19 / 20 mm. nominal bore Medium 157.00 Mtrs. 108.07
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leckage and
300 Supplying & erecting fan hook box of 10 mm M.S. round 157.00 Nos. 108.07
bar bounded to the RCC bars up to 50mm length each side
and pierced through a 16 Gauge M.S. box / Heavy Duty
PVC box complete erected concealed in Ceiling with
necessary finishing.
301 Supplying & erecting single phase approved make industrial 40.00 Nos. 2054.34
exhaust fan suitable for medium duty ring mounted low
noise operation suitable for medium duty having following
dia size and maximum speed in RPM [A] 305 mm dia
RPM Cat.II (Make:- Crompton, Havells, Orient)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
302 Supplying and erecting approved make Octagonal pole made 20.00 Nos. 8192.11
from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation
(Included) as per details given by manufacturer considering
site requirement.(D) 6 Mtr. Long 70 mm Top X 135 mm
bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long with necessary
G.I. J Bolts .Approx Pole weight 59 kg
303 Supplying & erecting approved make SMC press moulded 12.00 Nos. 515.10
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box. (b)
250mm x 200mm x 100mm [deep]
304 Providing street light pole bracket comprising main B Class 20.00 Nos. 561.56
MS pipe of 4.2 cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of approx. 45cms.length
and suitable for 76.5 mm / 80mm. / require size pole top
having sufficient fastners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site
condition & suitable welded stiffener reducer and nipple
with check nut complete painted with one coat of Red oxide
/ PU base primer and two coats of Aluminium / PU paint.
paint with following nos of arms. [A] Single Arm bracket
305 Supplying & erecting approved make Digital time switch 2.00 Nos. 3168.37
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as required with
necessary connection erected as directed.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
306 Supplying & erecting power contactor ,AC3 duty for time 2.00 Nos. 2782.55
switch complete erected as per direction Cat III (Make:-
Indoasian, L&T (LK), ABB, Schneider) [D] 4 pole 440V
307 Providing & Erecting full SS Body (SS 304) Split type water 5.00 Nos. 61115.10
cooler having storage capacity 160 to 175 Ltr.(Tank SS 304)
& Cooling capacity 150 ltr. Per hour @ an ambient temp of
350 C.The outlet temp. of the water should drop by 150C
within a hour,The water cooler should be comprising of
hermetically sealed Reciprocating compressor with R134A,
fan motor, Copper Condensing unit with company fabricated
Outdoor Unit water tank surrounded by evaporating coil,
thermostats, relay etc.complete with necessary copper tube
& Insulation, M.S Chanel Stand with Painting for water tank
& M.S. Powder Coated Stand for Outdoor unit with
Installation. With DPELCB and 4 Way DB Box with
accessory Three core Cord for connection.(Make:- Blue
Star,Usha,Voltas)
308 Supplying and erecting water filter cum purifier with ultra 5.00 Nos. 5424.71
violate technology. (Aquaguard / waterdoc model or
equivalent symphony/ crystal/videocon model)
309 Supplying & erecting 5 stage single reverse osmosis water 5.00 Nos. 29187.99
purification system with M.S. powder coated frame, prefilter
housing with 'O' ring presediment filter GAC filter, carbon
filter suitable buster DC pump capacity 80 psi, mention with
40 psi inline type post carbon filter auto low & high pressure
switches with following size of storage tank & LPH capacity
& erected as directed[C] 50 Ltr / Hr with 150 psi 2 nos
310 Supplying and erecting horizontal / vertical mounting type 20.00 Nos. 11455.42
storage water heater with copper container housed in
M.S./S.S./ABS body insulated with glass wool/puff
complete with heating elements,adjustable thermostats 300C
to 850C, indicating lamp, safety valve, fusible plug,
etc.complete erected with coach bolts, nuts. washers &
cementation (C)25 Ltr. with 2 KW. heating element
Premium Category
311 Supplying and erecting chromium plated heavy duty brass 20.00 Nos. 181.80
valve for inlet pipe of water heater 15 mm dia.)
312 Supplying and erecting 15mm brass non-return valve for 20.00 Nos. 232.30
inlet pipe of storage water heater.
313 Supplying and erecting dead pressure releasing valve for 20.00 Nos. 385.82
storage type water heater with necessary materials.
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
314 Providing & erecting fibre reinforced PVC flexible pipe with 80.00 Rmts. 181.80
brass locking nuts & washers & clips at both ends complete
erected without leakage
315 Supplying, installing, testing & commissioning of SOLAR 5.00 Nos. 189956.76
WATER heating system as per prevailing IS code
comprising of Solar flat locket collector, stainless steel hot
water storage isolated tank with S.S. heat exchanger,
absorber made of copper sheet & copper tube of following
capacity in liter / day (LPD) with "B" size aluminium box
collector with appropriate capacity electrical backup
arrangement (Excluding inlet & outlet pipe lines) (E)
Capacity of 1000 LPD
316 Supplying & erecting resin bonded flap rock wool / glass 192.00 Mtrs. 767.60
wool with conductivity valve 1.67 sq.mm per watt & to with
stand the temp. to 100 degree centigrade C thickness 50mm
with G I pipe of following size dia "B" class as per IS:1239.
The plastic sheet to be used as covering of glass wool. Al.
cladding besides other materials like chicken mesh, 26 G Al.
Sheet shall be used for cladding the insulation pipe.(E) for
317 Supplying and erecting approved make panel mounting type 5.00 Nos. 1275.63
Digital Voltmeter having 3 digits LED display, 0 to 750 AC
Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration
318 Supplying and erecting approved make panel mounting type 5.00 Nos. 1558.43
Digital Ammeter having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps suitable to operate
on 500 Volt AC , erected on existing panel board with all
connection, wiring etc .with manufacturers calibration
319 Providing & erecting L.T. Current Transformer with bar 15.00 Nos. 274.72
primary 50/5 to 1000/5 ratio 15 VA burden erected in
existing CRCA box duly secured with insulating materials
connected to the meter
320 Supplying and erecting approved make suitable panel 15.00 Nos. 43.43
indicator LED type lamp, lens cover, complete erected with
necessary connections.
321 Providing & erecting open well horizontal mono block 2.00 Nos. 15707.52
pump set with cast iron body, complete for three phase
submersible motor having[C] For 3 HP 3 phase open well
horizontal mono block pump set suitable for 85 LPM to
LPM @ 11 mtr to 33 mtr head suitable for 50/65 mm dia
delivery pipe Cat.II (Make:- Crompton, Lubi )
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
322 Supplying & erecting approved make motor control 2.00 Nos. 7722.46
cubical panel (Direct - on - line) made from 16 G. CRCA
sheet duly epoxy powder painted inside and outside with
hinged doors and locking, arrangement consisting of suitable
size of ON- OFF isolator (AC - 3/23duty) main fuses, single
phasing preventer, indicating lamps for R- Y - B phases,
overload relay, Automatic water level controller, Ammeter,
Voltmeter each with two way selector switch incoming,
wires duly socket crimped, main contactor & overload relay,
start - stop push buttons, to be erected on angle iron frame
grouted on wall as directed. The isolator, overload relay &
contactors will be of L & T, Siemens or BCH make only.(A)
DOL up to 5.0 H.P.
323 Providing and erecting ISI marked PVC insulated PVC 90.00 Mtrs. 146.45
Sheathed Flat flexible Submersible copper cable approved
make of following Size. (C) 3 Core x 4 Sq. mm
324 Providing Water proof straight Joint in PVC insulated flat 2.00 Nos. 189.88
flexible copper cable by using insulating material, water
proofing material, & making the joint complete. (A) Up to
325 Supplying of following size of HEAVY UPVC column pipe 30.00 Rmts. 359.56
with coupler and wire lock [B] 50 mm dia
326 Supplying, & erecting C.I. swing, check type non-return 2.00 Nos. 1020.10
(Reflux) Valve -ISI marked suitable for following size (A)
327 Supply of following size of TOP & BOTTOM accessories 2.00 Per Set 1489.75
i.e. Adaptor set (CI) long, pump guard set, starter pipe
Rubber ring for submersible pump & UPVC column pipe as
directed by Engineer - in - charge with necessary plumbing
as desired.[D] 50 mm dia
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
328 Supplying, Erecting, Testing & Commissioning the 1.00 Nos 1575617.17
passenger / stretcher lift having following main features:[1]
GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with high efficiency
shall be used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback closed loop
system shall be used for lift car and door operation which
shall be full collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and safety
controls. [3] Car with M S platform with bracings of
adequate size and to sustain the impact load cabin +
passenger with safety factor of fire for steel and side panels
of Stainless steel of sheet of grade 304 duty. Car ceiling will
be S.S. finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be of s/s 304 chaker plate design
sugeested of engineer in charge. of engineer in charge. Car
doors shall be of stainless steel grade 304, hairline finish
with centre opening / telescopic automatic doors. Car panel
will also be S.S. 304 finished with emergency stop device,
mechanical door safety device, facility of auto/ attended
mode. All car panel buttons and all floor switches must be
with brail language as per lift act. [4] All landing doors must
be fire rated for 2 hour shall be fully automatic centre
opening/ telescopic opening made of hairline finish steel
grade of 304 with key holes and infrared curtains with
Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also, Emergency
Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
with centre opening / telescopic automatic doors. Car panel
will also be S.S. 304 finished with emergency stop device, Estimated
mechanical door safety device, facility of auto/ attended Rates Total Amount
mechanical door safety device, facility of auto/ attended Rates Total Amount
mode. All car panel buttons and
Item of all floor switches must be Quantity
No. In figure to estimated
with brail language as per lift act. [4] All landing doors must quantities
be fire rated for 2 hour shall be fully automatic centre Rs. Ps.
1 opening/ telescopic opening 2made of hairline finish steel 3 4 5
grade of 304 with key holes and infrared curtains with
Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also, Emergency
Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed. [10] Spring buffers/PU Buffers
shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge. [17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply shall
be made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged
by Lift Agency.
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift shall
be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
timer shall be provided.
[12] Voice annunciator with suitable music shall be Estimated
provided in lift car. Rates Total Amount
provided in lift car. Rates Total Amount
Item [13] Self diagnostics system for operational and safety according
Item of work Quantity Unit to estimated
No. parameters shall be provided in control panel. In figure
[14] Mechanical over speed governor with governor Rs. Ps.
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge. [17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply shall
be made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged
by Lift Agency.
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift shall
be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities.
[20] acrylic transparent licence/display A4 size holder in lift
car [20A] As per statutory requirement of
Govt. Of Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third
party insurance upto completion of free maintenance period
and submit the document for the same. [21] Car Panel
Operating Buttons with floor position indicator/buttons must
be of Auto Glow type clearly visible when view from inside
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller, drive and
all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for
lift is in scope of work which rating is sugested by CEICED
Department (electrical Inspector) (B) SPECIAL
be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.) Total Amount
not in lift agency’s scope.) Total Amount
Item [19] Agency has to provide all working drawings and according
Item of work Quantity Unit
No. documents and liaison services for obtaining all necessary In figure to estimated
permission from lift inspector and other authorities. quantities
[20] acrylic transparent licence/display A4 size holder in lift
1 car [20A] As2 per statutory requirement of 3 4 5
Govt. Of Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third
party insurance upto completion of free maintenance period
and submit the document for the same. [21] Car Panel
Operating Buttons with floor position indicator/buttons must
be of Auto Glow type clearly visible when view from inside
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller, drive and
all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for
lift is in scope of work which rating is sugested by CEICED
Department (electrical Inspector) (B) SPECIAL
FEATURES DESCRIPTION OF LIFTS for PREMIUM
category 1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS Serial
Communication mode including Regenerative power
efficient operation,on site programming facility, Anti
nuisance, Pte-opening, BMS/RMS with necessary online
real time monitoring system having necessary connectivity
for remote monitoring & other suitable supporting hardware
& software devices to fulfil the purpose. 2. Floor Indication
LCD Display with call registration & brail mark with arrival
gong and hall lantern & TFT Screen in the car with MP3
Voice Announcer. 3. CAR Panel should be Scratch
resistive SS Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have fire rating up
to 2 hours and car door must have multi-level crisscross
beam door protection. 4. To & fro communication system
& wiring (i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring system.agency
has to provide mobile app and user id and password for
monitoring 8 / 10 Passengers, Ground plus 3 upper floor
with Rated Speed of 1.0 m/sec., (C) With General PLUS
ADDITIONAL SPECIAL FEATURES attached herewith.
Total Cost of Construction Cost
(Rupees Seven Crore Seventy Three lakh Eighty One Thousand Sixty One and Seventy Five Paise Only)
Rates Total Amount
Rates Total Amount
Item of work Quantity Unit to estimated
I/We am/are willing to carry out the work at ………………………………………………..% above/below (percent
should be written in figures and words) of the estimated rates mentioned above. Amount of my/our tender works out
*Estimated amount *Estimated amount
Put to tender Rs…77381061.75 Put to tender Rs.77381061.75
Deduct ……. % below Rs……………………..…. Add ……. % Avove Rs…………..….
Net Rs. …………………….… Total Rs. ………….…
The Contractor shall exhibit a board with detailed specification and details of work as directed by
the Engineer-In-Charge for which no extra payment shall be made.
The labour cess will be deducted as per prevailing rules i.e. 1% of the work done
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt.G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there
4 is a change as per actual mix design the cost of difference of cement consumption have been deducted from the
rate of original item at the rate of input rate mentioned in all the tender.
Dismentalling of Credit materials amounting of Rs. -662286.87 must be recovered from Contractor's respective
Deputy Executive Engineer Executive Engineer
R&B Sub Division R&B Division
Khedbrahma Himatnagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.GR to be attached with DTP_SBD.pdf
GRs - SBD with Index_compressed.pdf
GR - 1.pdf
GR - 2.pdf
GR - 3.pdf
GR - 4.pdf
GR - 5.pdf
BUILDING WORK BOOKLET.pdf
General Specification - State.pdf
BOQ GIRL HOSTEL AT KHEDBRAHMA_.pdf
Details Specification - GIRL HOSTEL.pdf
ELECTRIC WORK.pdf
SBD Book_2023_GIRLS HOSTEL AT KHEDBRAHMA.pdf
Specification Index - GIRL HOSTEL.pdf
Pre-Q - SCSP - XXX Pkg-XX8_2026_04_30.pdf
Schedule-D.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].