Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹7.8 L Quoted ₹8.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹8.5 L+₹59,220 (7.45%)Rejected-AOC | ₹8.5 L+₹59,220 (7.45%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹8.9 L+₹93,260 (11.7%)Rejected-AOC 63 TALLA GAON POST UNCHAKOT DISTT NAINITAL 263134 UK | NAINITAL | NAINITAL | UTTARAKHAND | 263134 | ₹8.9 L+₹93,260 (11.7%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹9.6 L+₹1.6 L (20.7%)Rejected-AOC | ₹9.6 L+₹1.6 L (20.7%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹10.1 L+₹2.2 L (27.5%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | ₹10.1 L+₹2.2 L (27.5%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹10.5 L
EMD Value
₹21,040
Closing Date
29 Jul 2022, 6:00 pmClosed
GE 871 EWS
GE 871 EWS c/o 56 APO
REPAIR REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING TUBE LIGHT FITTINGS INCLUDING OTHER EM ALLIED WORKS AGAINST MAINT PROGRAMME OF ZONE III (JOSHIMAT AULI TAPOWAN AND MANA UNDER GE 871 EWS
2022_MES_535013_1
8692/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath Auli Tapovan Mana
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹21,040
Yes
29 Aug 2022
1 Jul 2022
5 Aug 2022
1 Jul 2022
29 Jul 2022
15 Jul 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
M&L for point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for one light/bell point controlled by one ,one way switch .
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on the same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 6 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S & F socket out let 5 pin 5/6 Amps all as specified and directed.
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
S&F 5 watt LED bulb. cool day light, 230/240V AC all as specified and directed.
S&F 9 watt LED bulb cool day light, 230/240V, AC all as specified and directed.
S&F LED tube light fitting bright 18 watt slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F of bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed.
S&F call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed
Taking down and refixing of LED tube light fitting bright 18 Watt slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed
Supply and fix in replacement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed
All as per item No 28 here in before but MCB DP 63 amps.
All as per item No 28 here in before but MCB DP 100 amps.
All as per item No 28 here in before but MCB TPN 63 amps.
All as per item No 28 here in before but MCB TPN 100 amps.
M&L earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
S&F in replacement of plug top 15 Amp white or ivory, ISI marked all as specified and directed.
S&F in replacement of plug top 5 Amp white or ivory, ISI marked. all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S & F in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F in replacement of 5 watt LED bulb. cool day light, 230/240V AC all as specified and directed.
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC all as specified and directed.
S&F in replacement of LED light fitting,10 watt bulk head luminaries, Landscape lighting fixture with all accessories and including connecting up with twin core twisted flexible copper conductor from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of LED Tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of LED tube light fitting bright 18 watt, slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply & fix in replacement of on load change over switch 4 pole, 63 Amps suitable for 3 phase & neutral, 415 Volts in sheet metal enclosures all as specified & directed.
Supply & fix in replacement of on load change over switch 4 pole, 100 Amps suitable for 3 phase & neutral, 415 Volts in sheet metal enclosures all as specified & directed.
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed Note:- Spare items shall be measured and paid separately.
S&F in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F in replacement PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
S&F in replacement inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made stainless steel duly prewired.
S&F in replacement indication lamp (Green/Red) as per required at site all as specified & directed.
S&F in replacement thermal Auto cut of range 0-90 degree centigrade (ISI marked) all as specified and directed.
S&F in replacement geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F in replacement circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F in replacement bottom plate as per existing size (ISI Marked) all as specified and directed
S&F in replacement Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F in replacement Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed.
Taking down carefully unserviceable exhaust fans of any size from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condenser, rubber shackle will be measured and paid separately
S&F in replacement of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed.
S&F in replacement of condenser suitable for exhaust fan capacity of 4/3.15/2 MFD all as specified and directed.
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for taking out burnt winding and rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 600 mm sweep all as specified and directed.
S&F in replacement blade suitable for exhaust fan 300/450/600mm, size as that of existing defective one all as specified and directed. (ISI Marked)
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multi stranded copper conductor with 01x6 sqmm PVC insulated multi stranded copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with casing caping will be measured as one length.
M&L in replacement of sub main wiring in PVC concealed conduit of required size 2x6 sqmm PVC insulated multi stranded copper conductor with 01x6 Sqmm PVC insulated multi stranded copper conductor as earth continuity wire all as specified and directed. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with conduit will be measured as one length.
Supply and fix in replacement of cable PVC insulated solid aluminium conductor of size 10 sqmm 2 core flat 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting for surface ceiling light 10 watt, colour white/warm white Ceiling Cut out 108 X 108 mm, thickness 15 mm and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fix in replacement of LED slim square panel light fitting, 36 Watt, 2x2 feet edge-lit luminaire suitable for arm strong/grid ceiling for low ceiling and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply and fix in replacement of PVC flexible pipe of size 20 mm dia all as specified and directed.
S & F in replacement of switch socket outlet 15 Amp including PVC gang box and fixing screw ISI marked.
S&F in replacement of switch socket outlet 5 Amp including PVC gang box and fixing screw ISI marked.
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
Supply & fix in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694, 1100 Volts grade ISI Marked all as specified and directed.
Supply & fix in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694, 1100 Volts grade ISI Marked all as specified and directed.
S&F in replacement Heat pillar rod 750 watt complete tube and element ISI marked all as specified and directed.
S & F in replacement of PVC Conduit 20 mm dia suitable for 1100 volts, 230/240 v AC all as specified and as directed.
S & F in replacement of PVC Casing Caping 25 mm size suitable for 1100 volts ,230/240 V AC Supply all as specified and as directed.
RAZA BUILDERS
JAGAT POWER ELCTRICAL
Amit Engineering
M/S Swarn Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .