Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹212.8 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹244.8 Cr+₹31.9 Cr (15.0%)Admitted-Finance RG METRO ARCADE SECTOR 11 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L2 | Admitted-Finance | |
| 3 | L3₹247.5 Cr+₹34.6 Cr (16.3%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹257.4 Cr+₹44.6 Cr (20.9%)Admitted-Finance 1 PARSWADA POST SHAHAGANJ VILLAGE | INDORE | INDORE | MADHYA PRADESH | L4 | Admitted-Finance | |
| 5 | L5₹281.0 Cr+₹68.2 Cr (32.0%)Admitted-Finance HEAD OFFICE 8TH FLOOR EXPRESS CORPORATE PARK SECTOR 16A FILM CITY NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VA TECH WABAG LTD L4 | Dineshchandra R Agrawal Infracon Pvt. Ltd. L7 | Triveni Engineering and Industries Ltd. L5 | AYYAPPA INFRA PROJECTS PVT.LTD L1 | HNB ENGINEERS PVT. LTD. L3 | Inderdeep Infra India Limited L6 | ENVIRO INFRA ENGINEERS LIMITED L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00A) Design and Build Contract of various units for following: | ||||||||||
| 1.01 | A-1) Capital cost for Mitraon
a. Wastewater Pumping Stations – 38.25 MGD for Mitraon and 2.5 MGD for Jharoda
b. 17.0 MGD Capacity Wastewater treatment Plant | 1 | Nos | 91,44,75,408 ₹91,44,75,408 Lowest | 1,45,36,33,053.95 ₹1,45,36,33,053.95 | 97,76,00,000 ₹97,76,00,000 | 1,04,21,03,500 ₹1,04,21,03,500 | 98,91,00,000 ₹98,91,00,000 | 1,17,51,12,781 ₹1,17,51,12,781 | 1,54,60,36,000 ₹1,54,60,36,000 |
| 1.02 | A-2) Capital cost for Mitraon
Disposal Main up to Disposal point
c. K7 DI Pipe- (Open Cut) Length- 2200 Meter
d. K7 DI Pipe (Above Ground) Length- 100 Meter
e. MS Pipe (By Trenchless) Length- 200 Meter
f. K7DIPipe-(Open Cut)Length-400Meter | 1 | Nos | 13,56,22,871 ₹13,56,22,871 | 12,95,05,490.26 ₹12,95,05,490.26 | 10,08,00,000 ₹10,08,00,000 | 3,77,96,500 ₹3,77,96,500 Lowest | 7,20,00,000 ₹7,20,00,000 | 16,01,65,199 ₹16,01,65,199 | 19,58,80,000 ₹19,58,80,000 |
| 2.00B) Operation and maintenance Cost | ||||||||||
| 2.01 | B -1) O&M costfor15yearsofMitraon(Wastewater Pumping Stations
–38.25 MGD and Wastewater Treatment Plant–17.0 MGD) | 1 | Nos | 57,05,28,000 ₹57,05,28,000 | 1,00,43,28,291.82 ₹1,00,43,28,291.82 | 70,75,00,000 ₹70,75,00,000 | 66,61,00,000 ₹66,61,00,000 | 28,70,08,979 ₹28,70,08,979 Lowest | 70,13,15,852 ₹70,13,15,852 | 56,20,00,000 ₹56,20,00,000 |
| 2.02 | B-2) O&Mcostfor15yearsfor11.35MLDforJharodaSPS | 1 | Nos | 14,26,32,000 ₹14,26,32,000 | 5,55,02,352.97 ₹5,55,02,352.97 | 1,14,50,000 ₹1,14,50,000 Lowest | 5,40,00,000 ₹5,40,00,000 | 3,18,91,021 ₹3,18,91,021 | 19,82,44,714 ₹19,82,44,714 | 3,20,00,000 ₹3,20,00,000 |
| 3.00C) Electricity Cost | ||||||||||
| 3.01 | Annual Electricity Consumption for 15 Year | 1 | Nos | 81,08,52,013 ₹81,08,52,013 | 1,20,31,96,402.5 ₹1,20,31,96,402.5 | 1,01,27,10,750 ₹1,01,27,10,750 | 32,85,00,000 ₹32,85,00,000 | 1,09,50,00,000 ₹1,09,50,00,000 | 1,23,19,56,072 ₹1,23,19,56,072 | 11,19,09,000 ₹11,19,09,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.2 Cr
Closing Date
22 Oct 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (P) SR II, Room No. 307,
Executive Engineer (P) SR II, Room No. 307, Varunalaya Phase-I, Jhandewalan, Karol Bagh, Delhi-110 005
NIT No.4 /EE (P) SR.II/ (2025-26)
2025_DJB_276899_1
NIT No.4 /EE (P) SR.II/ (2025-26)
Open Tender
Composite Works
Works
5475 days
Executive Engineer (P) SR II, Room No. 307
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,500
DJB EMD A/c No. 50448339804 at Indian Bank,
₹2.2 Cr
Office of Chief Engineer (DR)-PROJECTS-I,
11 Feb 2026
14 Aug 2025
22 Oct 2025
14 Aug 2025
22 Oct 2025
25 Aug 2025
22 Aug 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1A) Design and Build Contract of various units for following: | |||||
| 1.01 | A-1) Capital cost for Mitraon
a. Wastewater Pumping Stations – 38.25 MGD for Mitraon and 2.5 MGD for Jharoda
b. 17.0 MGD Capacity Wastewater treatment Plant | - | Nos | - | - |
| 1.02 | A-2) Capital cost for Mitraon
Disposal Main up to Disposal point
c. K7 DI Pipe- (Open Cut) Length- 2200 Meter
d. K7 DI Pipe (Above Ground) Length- 100 Meter
e. MS Pipe (By Trenchless) Length- 200 Meter
f. K7DIPipe-(Open Cut)Length-400Meter | - | Nos | - | - |
| 2B) Operation and maintenance Cost | |||||
| 2.01 | B -1) O&M costfor15yearsofMitraon(Wastewater Pumping Stations
–38.25 MGD and Wastewater Treatment Plant–17.0 MGD) | - | Nos | - | - |
| 2.02 | B-2) O&Mcostfor15yearsfor11.35MLDforJharodaSPS | - | Nos | - | - |
| 3C) Electricity Cost | |||||
| 3.01 | Annual Electricity Consumption for 15 Year | - | Nos | - | - |
stage.html
html • 0.05 MB
techsummary_365257.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Volume_V.pdf
Tender Documents • 0.98 MB
BOQ_365257.xls
BOQ • 0.34 MB
Volume_VII.pdf
Tender Documents • 0.73 MB
Volume_VIII_Drawing_Soil_Investigation_Report_1208.pdf
Tender Documents • 36.12 MB
Volume_I.pdf
Tender Documents • 2.04 MB
Volume_II.pdf
Tender Documents • 1.06 MB
Volume_III.pdf
Tender Documents • 1.16 MB
Volume_IV.pdf
Tender Documents • 2.43 MB
Volume_VI.pdf
Tender Documents • 0.83 MB
Corri4.pdf
PDF • 2.21 MB
Corri3.pdf
PDF • 0.95 MB
Corri2-NIT4.pdf
PDF • 0.46 MB
Corri1_NIT4.pdf
PDF • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .