EXECUTIVE ENGINEER(E), EDI, BENGALURU
Electrical Division-I, IV Floor, CTO Building, Rajbhavan Road, Bengaluru 560001
Providing wiring shifting and Installation of 5 Nos 3TR Spacemaker in the CDOT Exchange 1st floor TE Building Raichur
2022_BSNL_102995_1
29/EEE/ED-I/BGL/2021-22
Open Tender
Electrical Works
Item Rate
30 days
TE building Raichur
as per NIT
3 documents required · 3 mandatory
₹590
Accounts Officer (Cash), HQ, BSNL, BGTD
Exempted
7 Feb 2022
25 Jan 2022
5 Feb 2022
25 Jan 2022
4 Feb 2022
25 Jan 2022
25 Jan 2022 - 4 Feb 2022
Amount
ITC of 3TR Spacemaker AC unit at TE Raichur CDOT
Shifting and transportation of 5nos 3TR Spacemaker AC units consisting both indoor and outdoor units from TE Chikkaballapur to TE building Raichur, (approximately 410 KMs - one way)including loading and unloading, arranging necessary tools and plants , etc, complete as reqd.
Installation of 3.TR Spacemaker AC units to suit existing opening with all accessories like copper refrigerant line hot gas and liquid lines, valves flare nuts, indoor and outdoor units draining piping, insulation , pressure testing, vaccumissing, toping up gas, etc, as reqd.
S/L of extra coppper refrigerant pipe both hot gas line and liquid refreigerant lines of (1/2)" and (3/8)" or (1/4) "dia respectively i/c providing foam insulation, brazing etc as reqd.
S/F of 38mm x 5mm thick angle iron frame work for condensor unit i/c cutting welding, painting, grouting.etc ar reqd
S/F of 45mm x 5mm thick angle iron frame work for condensor unit i/c cutting welding, painting, grouting.etc ar reqd
S/F of following ways surface/recess mounting, vertical type, 415V, TPNMCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mouting MCBs [but without CBs and incommer] etc as reqd. [Havells/Hager Make] 4 Way [4 + 12] double door
S/D following sizes of FR PVC insulated copper cond. Single core cable in existing surface/recessed steel/PVC conduit. As reqd. [ISI Mark] a) 4core x 16 Sqmm
b) 3core x 4 Sqmm multistrand
c) 6core x 1.5Sqmm Multistrand
d) 3core x 2.5Sqmm multistrand (I/d to O/d Unit)
S/F of following sizes of medium class PVC conduit. Along with accessories in surface/recess/including cutting the wall and making making the good the same in case of recessed etc as reqd. a) 25mm
c) 25mm dia CPVC for drain
S/F of 5A to 32/63A rating MCBs in existing MCBDB complete with connection, testing and commissioning etc as reqd.[M/s. Hager or S/S] a) 63A TPN MCB
b) 32A DPMCB
S/F of following flexible rigid PVC pipe for protection of refrigerant lines i/c clamping on the wall making good the damages etc. as reqd. a) 3" FR PVC Pipe
Supply and topping of R-22Gas in existing AC units, i/c leak testing, arresting of leak if any etc as reqd.
S/F of DPDB 1No. With 20A SPMCB i/c interconnections, earthing etc as reqd. {M/s. Hager/Indoasian or S/S make]
Sujan Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .