Loading…
Loading…
Tender Value
₹5.9 L
EMD Value
₹5,910
Closing Date
9 Apr 2026, 4:00 pmClosed
Deputy Executive Engineer, Electrical (R&B) Sub Division, Valsad
Repir to 16 Mtr.Highmast Poles at Madhuben Dam,Dist. Valsad.
291715
22 of 2025-2026
Open
Electrical - All
Works
Valsad
5 documents required · 5 mandatory
₹900
Executive Engineer, Electrical (R&B) Division, Surat
₹5,910
30 Mar 2026
30 Mar 2026
30 Mar 2026
9 Apr 2026
30 Mar 2026
Name Of Repir to 16 Mtr.Highmast Poles at Madhuben Dam,Dist. Valsad.
Item SOR Rate with
Qty. Unit words Amount
No. Rate 1% L.S.
30 Mtr 1 Replacing old & u/s by Supplying and erecting 77.00 77.77 #NAME?
Flexible PVC insulated multi strand multi core
1.1 kv grade ISI marked copper wires of
following size to be erected as directed. (h)
Sq.mm 3 core round PVC sheathed
30 Nos 2 Replacing old & u/s by Supplying and erecting 10711.00 10818.11 #NAME?
LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.) (B) Flood Light (IP-
65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage
protection. (vii) 250 watts Cat-lll
1 Nos 3 providing and erecting Approved make Four pole 6112.00 6173.12 #NAME?
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S. housing.ICS=100% of ICU
30 Nos 4 providing and erecting Miniature circuit breaker 268.00 270.68 #NAME?
single pole 0.5A to 2A system and having
breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark
8 Kg 5 Providing and erecting HOT deep Galvanised 77.00 77.77 #NAME?
iron strip wire 8 to 16 SWG.
3 Nos 6 Providing and erecting Pipe type earthing with 40 815.00 823.15 #NAME?
mm dia 2.5 mtr long 'B' grade G.I. pipe with
necessary coupling buch buried in specially
prepared earth pit & G.I. earth wire of 8 SWG
erected & connected as directed (For panel)
Item SOR Rate with
Qty. Unit words Amount
No. Rate 1% L.S.
3 Nos 7 For using salt and charcoal / coke as required for 170.00 171.70 #NAME?
pipe type earthing.
3 Nos 8 Supplying & erecting earth pit of minimum bore 4546.00 4591.46 #NAME?
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia
of 12mm with constant ohmic value surrounded by
highly conductive compound with high charge
dissipation suitable for following type of applications
with chamber and heavy duty cover.(approved make
OEM has to submit test certificate) & having back
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 / meter testing as per
IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable
to retain moisture for long time Necessary test report
must be submitted. (a) For Electrical Installation up to
440V in normal soil Length of pipe - 1 Mtr Back
filling compound - 1 Nos Bag of 15 Kg.
815 Mtr 9 Replacing old & u/s by Providing and erecting 152.00 153.52 #NAME?
XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
(A) 4 core 16 Sq. mm
775 Mtr 10 Making trench in Hard Murrum / Tar Road of 74.00 74.74 #NAME?
suitable width of 90 cm or required depth for
laying any size of cable or locating the fault all
over the run and back filling the same and
making the surface as normal ground.
Item SOR Rate with
Qty. Unit words Amount
No. Rate 1% L.S.
775 Mtr 11 Providing & laying approved make Double 62.00 62.62 #NAME?
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (A)50 mm outer dia
6 Nos 12 Providing and, fixing heavy duty flange type 47.00 47.47 #NAME?
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going
tails, insulating tape etc for following size of
cables. (D) 2 to 4 core 16 Sq. mm
24 Nos 13 Solder less crimping type Aluminium lugs 15.00 15.15 #NAME?
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (C) 16/25 Sq.mm.
I/We am /are willing to carry out the work at…………% above/below percent (should be written in figures and
words) at the estimated rates mentioned above amount of my/your tender works out as under.
*Estimated Amount *Estimated Amount
put to Tender Rs. 590772.23 put to Tender Rs.
Deduction …………….. % below………………… Add ………… % above Rs. …………….
Less Dismental 0.00 Less Dismental
The rates are inclusive ofall taxes, transport charges,storage Charges except GST and applicable
GST Will be paid.(Add GST Extra)
The materials covered under contractor should be got approved from the Deputy Executive
Engineer. In chargeof the work
The materials and work shall have to be used and carried out as specification in technical
All Works Shall be Carried Out as per Public Works Department hand book and Other
Specification Of The division or as directed
Rate are Inclusive Of 1% Labourcess in Tender amount so 1% of total amount of bill will be
Rate are Inclusive Of 1% Labourcess in Tender amount so 1% of total amount of bill will be
deducted from the bill
Note-6TheMaterial to be used in this work should be approved strictly from engineer-in –charge /Deputy
Ex. Engineer as applicable.
Note-7The Agency will have to agree to carry out the work as per brand demand of concern deptt.
Note-8An amount of Rs.0.00 (Rs.Nill only ) towards estimated credit value of dismantled materials shall
be recovered from the 1st R.A. Bill of this work.
Signature of Bidder Deputy Executive Engineer
Electrical (R&B) Sub-Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ madhuban highmast.pdf
FINAL _ SBD (Electrical Work) _ 2024 Tender Booklet.pdf
1 Page 5-8.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .