Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L1 | Accepted-AOC LOA issued | |
| 2 | L2₹7.1 L+₹8,818 (1.26%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.6 L+₹63,203 (9.01%)Rejected-Finance 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not eligible |
| Sl No | Description | Qty | Unit | Prime Computers L1 | AVNET Solutions L3 | SMART POWER L2 |
|---|---|---|---|---|---|---|
| 1.00 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] | 470 | Metre | 48 ₹22,560 Lowest | 58 ₹27,260 | 52 ₹24,440 |
| 2.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 1,350 | Metre | 27 ₹36,450 Lowest | 34 ₹45,900 | 35 ₹47,250 |
| 3.00 | Supply, Installation , Testing and commissioning of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Bosch FPA 1000 Series ,Cerberus by Siemens, Edwards EST3,Honeywell Morley Zxe Series) | 1 | Each | 1,68,200 ₹1,68,200 Lowest | 1,72,120 ₹1,72,120 | 2,70,000 ₹2,70,000 |
| 4.00 | Supply, Installation , Testing and commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) (Makes: Bosch/Siemens/Honeywell. | 50 | Each | 2,690 ₹1,34,500 Lowest | 2,900 ₹1,45,000 | 3,310 ₹1,65,500 |
| 5.00 | Supply, Installation , Testing and commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)(Makes: Bosch/Siemens/Honeywell. | 1 | Each | 3,150 ₹3,150 | 2,990 ₹2,990 Lowest | 3,410 ₹3,410 |
| 6.00 | Supply, Installation , Testing and commissioning of Linear Beam Smoke detector with addressable module having monitoring length 5 to 100m, IP42 protection category and three sensitivity levels, Tranmitter /Receiver built into same unit/separate independent units, Single -ended, reflective design, Six user selectable sensitivity levels, 16` to 328` (Use BEAMLRK beyond 230`) protection range ceiling or wall mount capability with increase angular adjustment. The device should be EN/54UL/VDS certified.(Makes: Bosch/Siemens/Honeywell. | 3 | Each | 84,000 ₹2,52,000 | 92,555 ₹2,77,665 | 25,500 ₹76,500 Lowest |
| 7.00 | Supply, Installation , Testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch/Siemens/Honeywell. | 3 | Each | 3,450 ₹10,350 Lowest | 3,890 ₹11,670 | 7,500 ₹22,500 |
| 8.00 | Supply, Installation , Testing and commissioning of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.(Makes: Bosch/Siemens/Honeywell. | 3 | Each | 7,444 ₹22,332 | 7,250 ₹21,750 Lowest | 8,200 ₹24,600 |
| 9.00 | Supply, Installation , Testing and commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX | 6 | Each | 1,980 ₹11,880 Lowest | 2,055 ₹12,330 | 2,300 ₹13,800 |
| 10.00 | Supply Installation Testing and Commissioning of 2 KVA UPS Com Inverter With 1 hour Backup MAKE LIBERT EINOVA /APC/LUMINOUS | 1 | Each | 40,260 ₹40,260 Lowest | 48,200 ₹48,200 | 62,500 ₹62,500 |
Tender Value
₹7.1 L
EMD Value
₹14,240
Closing Date
9 Jul 2025, 4:00 pmClosed
VISHWNATH KHICHI
ED - Karnal
Pdg. special repair to EI and Stage Lighting, Fire Alarm system, AC system, Sound System in Auditorium at Sports University of Haryana Rai Distt Sonipat. (Pdg. Fire Alarm system only).
2025_HRY_455806_1
2025AD21F76F A62D 4A30 A8E4 95EBF1E9CFDA665BAR
Open Tender
Electrical Works
Works
30 days
Kundli(MC)
2 documents required · 2 mandatory
₹1,000
₹14,240
Yes
14 Aug 2025
2 Jul 2025
10 Jul 2025
3 Jul 2025
9 Jul 2025
3 Jul 2025
Amount
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
Supply, Installation , Testing and commissioning of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Bosch FPA 1000 Series ,Cerberus by Siemens, Edwards EST3,Honeywell Morley Zxe Series)
Supply, Installation , Testing and commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) (Makes: Bosch/Siemens/Honeywell.
Supply, Installation , Testing and commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector)(Makes: Bosch/Siemens/Honeywell.
Supply, Installation , Testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. (Makes: Bosch/Siemens/Honeywell.
Supply, Installation , Testing and commissioning of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.(Makes: Bosch/Siemens/Honeywell.
Supply, Installation , Testing and commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX
Supply Installation Testing and Commissioning of 2 KVA UPS Com Inverter With 1 hour Backup MAKE LIBERT EINOVA /APC/LUMINOUS
SMART POWER (BID ID -1292889)
AVNET Solutions (BID ID -1293202)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .