Loading…
Loading…
Tender Value
₹6.2 L
EMD Value
₹6,170
Closing Date
29 Sept 2026, 1:00 pm2d left
Published by the portal on this tender, for queries and grievance redressal.
Dismantling of 11 KV line and LT Line with its dump at suitable place on site up to completion of work and its safe loading/unloading/weithing carriage from dump site to je's store (including broken STP/PCC Pole).
PCC pole 8.5 Mtr long
PCC pole 11 Mtr long
ACSR Weasel Conductor
ABC( 3x/95 + 1x70 + 1x16) Sqmm.
ABC( 3x50 + 1x35 + 1x16) Sqmm.
11 kv Composite Polymer Pin Insulator.
11 kv Comp. Poly. Disc Insulator 45 KN.
11 KV V-Type Steel Cross Arm 65x65x6 mm
Earth Rod 2540x20 mm
LT Distribution Box
Stay Set 16x1800
Stay Wire 06 SWG
Other Line Material.
Dragging of PCC pole to pit site
digging of pit erection and grouting (As per RESPO norms) of single pole 8.5 m long PCC Pole along with fixing of necessary hardware of single pole such as V-type X-arm
F-bracket
11KV Pin/Disc insulator
guarding angle & LT Clamp etc. (1.8 mm65x65x6) with nut & boltsas per RESPO specification and direction of E/I.
digging of pit erection and grouting (As per RESPO norms) of single pole 11 m long PCC Pole along with fixing of necessary hardware of single pole such as V-type X-arm
F- bracket
Fixing and errection of double poles on 11 mtr. Long PCC pole along with fixing of necessary hardware (Top channel
dropper
pins
disc etc) of doble pole alongwith necessery pin insulators and grouting as per RESPO specification and direction of E/I.
Ordinary earthing by MS earth Rod 2500mm long as per RESPO Schedule. Only GI wire& Earth rod shall be supplied by the department.
Grouting and Nuzzling of stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (Sand: brick ballast: cement). Only Stay wire shall be supplied by the Department.
Laying and stringing of 3 phase 3 wire 11 KV line on ACSR weasel/rabbit/Raccoon/Dog conductor as per RESPO specification and direction of E/I.
Laying of ABC (3X95+1X70+1X16) Sqmm.
Laying of ABC (3X50+1X35+1X16) Sqmm.
Making section of 11 KV line by fixing of All necessary accessories such as T-Off channel disc insulator with fitting pin insulator with pin along with sagging jumpering and binding etc only insulator shall be provided by the dept.
Erection and installation of barbed wire/danger board/Number plate/G.I. pipe 6 dia/
Holding Clamp for PCC Pole 8.5 Mtr.
LT Clamp with Eye Hook.
Stone Pad
Stay Clamp
11 KV F clamp for PCC Pole
P.G Clamp Panther to Panther Conductor.
Nuts & Bolts
Barbed wire
Distribution box Clamp
9913264
GEM/2026/B/8054375
Two Packet Bid
Title1,Title3,Title4,Title5,Title6,Title7,Title8,Title9,Title10,Title11,Title12,Title13,Title14,Tit
Kheri, Uttar Pradesh
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
₹3.0 L
60%
SUPERINTENDING ENGINEER, SE EDC 33/11 KV Sub Station Nai Basti District Hospital Road Lakhimpur, (Rajeev Kumar Yadav)
₹6,170
18 Sept 2026
18 Sept 2026
30 Sept 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Title1 | Dismantling of 11 KV line and LT Line with its dump at suitable place on site up to completion of work and its safe loading/unloading/weithing carriage from dump site to jes store (including broken STP/PCC Pole). | 1 | Job | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 3 | Title3 | PCC pole 8.5 Mtr long | 68 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 4 | Title4 | PCC pole 11 Mtr long | 60 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 5 | Title5 | ACSR Weasel Conductor | 9,637 | Mtr | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 6 | Title6 | ABC( 3x/95 + 1x70 + 1x16) Sqmm. | 1,500 | Mtr | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 7 | Title7 | ABC( 3x50 + 1x35 + 1x16) Sqmm. | 1,800 | Mtr | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 8 | Title8 | 11 kv Composite Polymer Pin Insulator. | 170 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 9 | Title9 | 11 kv Comp. Poly. Disc Insulator 45 KN. | 45 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 10 | Title10 | 11 KV V-Type Steel Cross Arm 65x65x6 mm | 43 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
| 11 | Title11 | Earth Rod 2540x20 mm | 94 | Nos | Shailendra Kumar 262701,Officeofthe Superintending Engineer, Electricity Distribution Circle Near Punjabi Colony Gate Rajghar, Lakhimpur Kheri 262701 | 45 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9913264.pdf
GEM_BID • 0.24 MB
boq-2_2026-09-18-15-18-38_a915917fd2f5920009b55e3be2dafb38.pdf
BOQ • 0.66 MB
boq_item_sample_file_2026-09-18-15-18-38_fa88a281f146e0a288c4fd45aca53349.csv
BOQ • 0.00 MB
1789725212.xlsx
GEM_OTHER • 0.01 MB
ATC_56c8eb99-842d-48c4-9f841789725405895_buyer3.mvvnl.up.pdf
GEM_OTHER • 2.11 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .