Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.9 L+₹7,938 (0.20%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.9 L+₹1.1 L (2.86%)Rejected-Finance FLAT NO 18 3RD FLOOR QUEENS CASTLE 100 FEET ROAD LAKSHMI NAGAR NANGANALLUR CHENNAI 600 061 | CHENNAI | TAMIL NADU | 600061 | L3 | Rejected-Finance L3 | |
| 4 | L4₹40.1 L+₹1.3 L (3.40%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L4 | Rejected-Finance L4 | |
| 5 | L5₹45.6 L+₹6.8 L (17.4%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance L5 |
Tender Value
₹44.6 L
EMD Value
₹89,212
Closing Date
26 Jan 2022, 6:00 pmClosed
Asst. General Manager (Engg-Electrical)
Airports Authority of India, Rajahmundry Airport, Madhurapudi Post, Rajahmundry-533102
Expansion of Turnpad and Fillets for link taxi track for B777-300ER type of Aircraft at Rajahmundry Airport, Sub-Head GLF Works
2022_AAI_100733_1
AAI/RJY/ENGG(E)/NIT-05/2021-22
Open Tender
Electrical Works
Item Rate
180 days
Airports Authority of India, Rajahmundry Airport.
Please refer Tender Document
14 documents required · 14 mandatory
₹1,180
₹89,212
11 Feb 2022
7 Jan 2022
28 Jan 2022
7 Jan 2022
26 Jan 2022
7 Jan 2022
7 Jan 2022 - 25 Jan 2022
Amount
Supply of Elevated Ominidirectional , Medium Intensity Taxiway/Apron Edge Light Fittings use with LED type Lamp complete with lens support mechanism, lens clamping mechanism, central column assembly, breakable coupling, Gaskets, Two Pin Secondary leads, Base plate with 6 Nos M-10 stainless steel bolts, spring washers and other accessories with Omni directional blue lens, not more than 10watts, 6.6 amps LED lamp, Electronic Drive assembly etc., complete as required and confirming to ICAO requirements and as per the technical specifications.
Supply of 2 x 105W, inset type Bi-directional, High Intensity Runway Edge light fittings, complete with prism assembly, optical assembly (lens/filter, reflector etc.), "O" ring seal, pressure relief test plug, 6.6A halogen lamp, filters (Left - White /Right - Yellow), shallow base, di-cast aluminum inner body & outer cover and other accessories complete etc., as required meeting the requirement of latest ICAO Annex -14,FAA compliant and as specifications of aerodrome design manual part - IV(Visual Aids) latest edition.
Supply of 2 x 105W, inset type Bi-directional, High Intensity Runway Edge light fittings, complete with prism assembly, optical assembly (lens/filter, reflectors etc) , "O" ring seal, pressure relief test plug, 6.6A halogen lamp, filters (Left-clear / Right - clear), shallow base, di-cast aluminum inner body & outer cover and other accessories complete etc., as required meeting the requirement of latest ICAO Annex -14,FAA compliant and as specifications of aerodrome design manual part - IV(Visual Aids) latest edition.
Supply of Inset type Omni-directional, medium intensity LED taxiway Edge light fitting suitable for Taxiway, Apron Edge Lights for operation at 6.6 Amps, series circuit supply, complete with blue lens support mechannism, lens clamping mechanism, gaskets,two pin secondary leads, including shallow base and other accessories etc. complete as required meeting the requirement of latest ICAO Annex -14,FAA compliant and as specifications of aerodrome design manual part - IV(Visual Aids) latest edition.
Supply of follwing size 5 KV grade stranded copper conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and anti-rodent treated, airport lighting cable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in technical specifications of the following sizes etc. complete as required. 1 C x 16.0 Sq.mm
Supply of follwing size 5 KV grade stranded copper conductor single core PVC insulated, PVC sheathed, unshielded, anti-termite and anti-rodent treated, airport lighting cable generally confirming to IS 1554- Part-II 1981 with up to date amendments and as specified in technical specifications of the following sizes etc. complete as required. 1 C x 6.0 Sq.mm
Supply of 2C X4 sq.mm secondary lead made out of multi stranded copper conductor, EPR insulalted PCP sheathed, treated 600V grade cable as specified in technical specifications etc.complete as required.
Supply of following rating of 5 KV 50 Hz, FAA certified PCP encapsulated isolating transformer suitable for individual series lamps airport lighting circuits and shall be designed for waterproof and suitable for direct burial in the earth or installation in a CI housing box etc. complete as required and as per the technical specifications. 200W, 20A/6.6 A Isolating Transformers
Supply of following rating of 5 KV 50 Hz, FAA certified PCP encapsulated isolating transformer suitable for individual series lamps airport lighting circuits and shall be designed for waterproof and suitable for direct burial in the earth or installation in a CI housing box etc. complete as required and as per the technical specifications. 15W, 20A/6.6 A Isolating Transformers
Supply of following rating of 5 KV 50 Hz, FAA certified PCP encapsulated isolating transformer suitable for individual series lamps airport lighting circuits and shall be designed for waterproof and suitable for direct burial in the earth or installation in a CI housing box etc. complete as required and as per the technical specifications. 15W, 6.6A/6.6 A Isolating Transformers
Supply of 5 KV grade, following size plug and receptacle of type I class B connector, suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable of following size etc. complete as required and confirming to the relevant IS specifications as required for following sizes. 16 Sqmm
Supply of 5 KV grade, following size plug and receptacle of type I class B connector, suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable of following size etc. complete as required and confirming to the relevant IS specifications as required for following sizes. 6 sqmm
Supply of 2C x 4 sqmm, 600 V grade plug and receptacle of type II, class 'B' connector and suitable field attachment with EPR insulated, PCP sheathed, two core copper conductor secondary cable etc. complete as required.
Supply of C.I top cover of 310 mm dia x 15 mm thick with suitable rubber gasket and 6 Nos. M10 tapped hole and SS bolts etc. suitable for cover the Cylindrical type transformer housing box etc. complete as required.
Supply of DOBEFIL 60 of Dr. Beck & Co. or equivalent sealant material suitable for fixing shallow base of inset type runway edge light fittings etc. complete as required
Supply of hardner 750 for DOBEFIL 60 sealant etc. complete as required
Supply of internally illuminated LED based Mandatory / Information Guidance signboards of various sizes made out of 4mm thick glare free poly carbonate sheet at front facia and 2mm thick anodised aluminium structure on other five sides with sufficient no. of 50mm dia 5.5mm thick aluminium legs with frangible couplings. Front facia shall be covered with 4mm thick non-specular glare free polycarbonate sheet having the required details (letters & symbols) screen printed on self adhesive film of 3M make and pasted on the inside of the polycarbonate sheet. The depth of the signboard shall not be less than 150mm. Signboard shall be uniformly internally illuminated with adequate no. of LEDs assembled on aluminium PCB of minimum 2mm thickness and suitable length and width and LEDs shall be 0.5W and shall have not less than 50,000 burning hours installed vertically with a spacing of LED strips (PCB) not more than 160mm with suitable rated power converter to achieve required illumination level stipulated in particular specification and suitable for operation on airfield series circuit input source of 2.8A-6.6A and shall have constant brightness for all current variation without flickering with all other accessories etc. complete as required confirming to ICAO requirements and as per the technical specifications.
Supply of omni directional Red lense (dome type) suitable for AMA make elevated type Halogen MIRL fittings.
Supply of following sizes of CI Collar boxes of round shape of outside dia 330 mm, 10mm thick all round except on top surface which is 15 mm thick having a clear opening of 220 mm and 6 nos M10 tapped holes at the hole center of 260 mm to receive light fittings base plate and bolts on both sides (top and bottom) with all accessories like rubber gasket, SS bolts, nuts etc. complete as required. 50 mm high CI collar box
Supply of following sizes of CI Collar boxes of round shape of outside dia 330 mm, 10mm thick all round except on top surface which is 15 mm thick having a clear opening of 220 mm and 6 nos M10 tapped holes at the hole center of 260 mm to receive light fittings base plate and bolts on both sides (top and bottom) with all accessories like rubber gasket, SS bolts, nuts etc. complete as required. 75 mm high CI collar box
Supply of following sizes of CI Collar boxes of round shape of outside dia 330 mm, 10mm thick all round except on top surface which is 15 mm thick having a clear opening of 220 mm and 6 nos M10 tapped holes at the hole center of 260 mm to receive light fittings base plate and bolts on both sides (top and bottom) with all accessories like rubber gasket, SS bolts, nuts etc. complete as required. 125 mm high CI collar box ( with Two Nos. 32 mm dia Holes)
Supplying of 50mm dia(outer)/38 mm Dia(inner) , DWC HDPE pipe, ISI marked conforming to IS 16205 part-24 with upto date amendments etc.complete as required.
Installation, Testing & Commissioning of Elevated type Runway/Taxiway edge light fittings and Isolating Transformer on the existing CI transformer housing box with connections etc. complete as required.
Installation, testing and commissioning of Inset type HIRL fittings complete with all accessories in the bitumen/ concrete surface using departmentally supplied sealing material DOBEFIL-60/Hardner 750 mixture with core drilling, aligning & setting including crimping / joining of plug & receptacles and moulding / crimping the leads, connection of secondary leads alongwith other accessories required for commissioning etc. complete as required.
Laying of the following size of 5KV grade, PVC insulated and PVC sheathed/XLPE Airfield lighting cable of following size in the existing RCC/HUME/METAL pipe/DWC HDPE Pipe/CI Housing box etc. complete as required. 1C x 6/16 Sq.mm
Cutting of cable groove with kerf cutting machine for laying one number of 2C x 4 Sqmm secondary leads meant for inset type RWY/TWY Edge light fitting on the concrete surface including kerfing,chieselling, cleaning and filling the groove with sealant compound after putting sealant primer after laying secondary lead which has been covered with jute for its protection etc. complete as required.
Laying of one number 2 x 4 sqmm EPR insulated & PCP sheathed stranded copper conductor airfield lighting secondary cable upto grade 1.1 KV in the existing GI pipe/groove cutting/CI Transformer housing box/Shallow base etc. complete as required.
Making field connections by crimping the following size plug and receptacle with the existing single core PVC copper conductor cable including filling the gap with water sealant material, applying HT & LT PVC insulation tape etc. complete as required. 16 Sqmm
Making field connections by crimping the following size plug and receptacle with the existing single core PVC copper conductor cable including filling the gap with water sealant material, applying HT & LT PVC insulation tape etc. complete as required. 6 sqmm
Making field connections by crimping the following size plug and receptacle with the existing Two core PVC copper conductor cable including filling the gap with water sealant material, applying HT & LT PVC insulation tape etc. complete as required. 2Cx 4Sqmm
Installation, Testing and commissioning of Airport operational Mandatory/Information guidance sign boards having 2 legs of various sizes including providing suitable strength Cement Concrete foundation as approved by Engineer In -Charge and anti-corrosive foundation bolts & nuts etc. complete as required.
Installation, Testing and commissioning of Airport operational Mandatory/Information guidance sign boards having 3 legs of various sizes including providing suitable strength Cement Concrete foundation as approved by Engineer In -Charge and anti-corrosive foundation bolts & nuts etc. complete as required.
Installation, Testing and commissioning of Airport operational Mandatory/Information guidance sign boards having 4 legs of various sizes including providing suitable strength Cement Concrete foundation as approved by Engineer In -Charge and anti-corrosive foundation bolts & nuts etc. complete as required.
Laying of 50 mm dia DWC HDPE pipe Complete with all accessiories like bends, couplers,tees etc in the soil (0.8 m below ground level) for Air-field cable laying including excavation and refilling the trench with the excavated soil after laying of Pipe etc., complete as required.
Numbering of Taxiway/Runway light fittings with ISI approved enamel paint with double coat yellow paint as background and numbering with black paint of suitable size serially etc., complete as required.
Retreiving of 5 KV grade, 1C x 6/16A copper conductor, PVC insulated, PVC sheathed GLF cables from ground/DWC pipe/G.I pipe including shifting the retreiving cable to AAI stores etc. complete as required.
Earthing with G.I. earth pipe of 4 metre long, 40 mm dia including accessories, and providing 300x300x450(H) mm RCC earth pit chamber suitable to receive 6mm thick MS chequered plate with handle duly painted with anti-corrsive, strengthening & compaction of soil below the earth pit chamber including providing suitable ratio PCC, providing & laying Cement Concrete of ratio (1:2:4) of depth 100mm surrounding the earth pit chamber covering surface area of 01 Sq.mtr including providing and fixing of reducer, water funnel with wire mesh arrangement for watering etc. with charcoal/coke and salt etc. complete as required.
Providing and laying earth connection from earth electrode to Runway/Taxiway edge light fitting with 6 SWG dia G.l. wire in 15 mm dia G.l. pipe below ground at 40 cm depth including connection with G.l. thimble, excavation and re-filling etc. complete as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with the cable etc. complete as required.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Excavation of existing Bituminous/ Concrete road to facilitate laying of metal pipe including disposal of material within 50 Meters lead and providing & laying in position 1:2:4 (1 Cement; 2 Coarse sand; 4 Graded stone aggregate of 20 mm nominal size) all works up to plinth level to fill up the excavated trenches after laying of the metal pipe complete above etc. complete as required.
Installation of Departmenatally provided C.I top cover of 310 mm dia x 15 mm thick with suitable rubber gasket and 6 Nos. M10 tapped hole and SS bolts etc. On existing Cylindrical type transformer housing box etc. complete as required.
DEEPAKELECTRICALS
Balaji Engineering
Techno Electricals
Manish Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .