Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹37.6 L+₹5.3 L (16.3%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC R | |
| 3 | L3₹37.8 L+₹5.4 L (16.8%)Rejected-AOC 1 259 CHUKKUWALA DEHRADUN UK | DEHRADUN | DEHRADUN | UTTARAKHAND | L3 | Rejected-AOC R | |
| 4 | L4₹38.3 L+₹6.0 L (18.5%)Rejected-AOC INDEX NO E 1504 HQ CWE DEHRADUN 63 RAJA ROAD DEHRADUN | L4 | Rejected-AOC R | |
| 5 | L5₹38.8 L+₹6.4 L (19.8%)Rejected-AOC 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 UDYAM CG 01 0003803 | BASTAR | CHHATTISGARH | 494001 | L5 | Rejected-AOC R |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
REPAIR TO MANCHANDA SQUASH COURT AND ALLIED SERVICES UNDER AGE BR I AT IMA DEHRADUN
2022_MES_572442_1
GE/IMA/T-86 2022-23 9278/E8
Open Tender
Support/Maintenance Service
Item Rate
90 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹1 L
Yes
6 Mar 2023
31 Dec 2022
30 Jan 2023
1 Jan 2023
28 Jan 2023
14 Jan 2023
Amount
Providing & fixing false ceiling at any heights with GRG (Glass Fiber Reinforced Gypsum) false ciling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 00.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm , cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of szie 15x32mm of length 600mm to form grid module of size 600 x600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per manufacturer's specifications and authoried dealer of manufacturer, drawing and as per directions of the Engineer-In-Charge. with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles including taking down existing unseviceable false ceiling.
S&F in repairs solid PVC wall lining 5 mm thick coloured PVC sheet inclusive of PVC beads and angles at corners /edges and fixing at site with nails all as specified and directed. The work shall be carried out as per manufactur's specifications and by authorised dealer of manufacturers and drawings.
M&L for Double charge/ultra charge Vitrified ceramic tiles premium quality any shade 9 mm thick (square/rectangular) polished , area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 Sqm , laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 3-4 mm thick layer of good quality tile adhesive over kota stone flooring complete all as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling, mass concrete and sub base of floor, hard standing etc complete including demolition of existing old concrete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in hard standing etc with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, finishing exposed edges fair or rounding or chamfering of exposed edges also filling in uneven surfaces to make good incl demolition of existing old concrete etc complete all as specified & directed.
Forming construction joint 30 mm deep x10 mm wide filled with sealing compound Grade 'A ' etc complete all as directed.
M&L for Rubberised pre-polished precast coloured concrete Interlocking paver block of any shape,size & with grey cement and pigment colour confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with and including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed. Make: Tulip/Mehtab/NITCO
Taking down existing brick pattern tiles of size 200 x 58mm x15mm as in wall cladding and filling the surface with ready mix external sand faced cement plaster of required thickness to match the existing brick pattern tiles with necessary groove cutting including applying two coat of exterior emulsion paint over a coat of cement primer upto a height of 10.0 metre complete all as specified and directed by GE Note : - 1. The rates are deemed to be included all necessary scaffolding etc.
Preparation of old plastered/unplastered surfaces of wall and applying one coat of weather exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) complete all as directed. Note : The work shall be carried out upto 10m height. The rates are inclusive of scaffolding etc.
Preparation of old plastered surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper by mechanical means/Roller on walls complete all as specified and directed.
Preparation of old plastered surfaces of ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper by mechanical means/Roller on ceiling complete all as specified and directed
Preparation of old or previously treated concrete/plastered surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any colour over a coat of primer complete all as directed.
Preparation of old painted steel surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed
Preparation of new untreated steel or iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified.
All as per item no.14 above but n. exc 10 Cm in width or girth when unconnected with other painting or painted in different tint.
M&L for Granite stone ( Lakha red) (table rubbed & polished) for wall lining (veneering to wall) 12-15mm thick with and including 15 mm thick rendering in CM (1:3) and jointed with grey cement slurry, and pointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite stone including dismantling of existing stone slabs & cement mortar bedding and rubbish off the premises complete all as directed. Note : Any additional fittings such as clamps, screws required to hold the granite on vertical position deemed to be included in the rate.
M&L for heavy duty pre-polished chequered cement concrete coloured tiles 30 cm X 30 cm X 25 mm thick, set, jointed & pointed in neat cement slurry in floor with grey cement & pigment to match the surface of tiles over & including 15 mm thick screed bed in cement mortar 1:6 complete including dismantling of existing tiles with screed bed of any description and in any position complete all as specified and directed. Make: Tulip/Mehtab/NITCO
M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc including demolition of existing cement concrete complete all as directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required and dismantling of existing damaged kerb stone complete all as directed. Make:- Tulip / Mahtab / NITCO
Providing & fixing frame less fully glazed 12mm thick toughened glass door shutter (in one/two shutter) with floor mounted pivoted door spring heavy duty to shutter using enox/ozone make patch fittings, including, stainless steel handle 300mm long, lock and cutting holes as per partition including all items to complete the work as per direction & specification..
Providing & fixing 12mm thick full height toughened glass partition (upto soffit of slab/beam) using enox/ozone make patch fittings,The joints between the glass to be filled with necessary water proof silicon including all items to complete the work as per direction & specification.
M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) including demolition of brick work/stone masonry built in cement mortar complete all as specified and directed.
M & L for 12mm thick plaster on faces of brick work or concrete surface with using READIPLAST (Readymixed) cement plaster water powder ratio 17-19% by weight, finished even and smooth without using extra cement and mixed with water proofing compound as per manufacturer's instructions, complete all as specified and directed. Make:- UitraTach/ACC/Birala
S&F Mild steel framed such as grills, gratings etc with end of bars shouldered and/or riveted, ladders, framed balusters, walk ways railing and similar work conforming to Fe 290 Gde E-165 fixed on purin top of raised roof as support of polycarbonate sheet complete all as specified & directed. Note. Scaffolding required to fix the item deemed to be included in quoted rate.
S&F Sand witched Polycabonate coloured roof sheet of 10mm thick including aluminium strips size 100x3mm and rubber packing over sheet joint including sealing of joints properly with epoxy sealing compound etc, and fixing with self driven screws , rubber & steel washers in metal frames in circular domes of center raised roof including dismantling of existing sheet etc complete all as directed. Note:- 1. Wastage of sheets in circular domes deemed to be included in the quoted rate. 2. Scaffolding required to fix the sheet deemed to be included in quoted rates
Cutting chases,pinning in, making good to facings where required and pointing in cement mortar 1:3 for inserting the ends or edges of roof sheet in brick wall complete all as directed.
M&L for Cement concrete 1:2:4 type B-1 (20mm graded crushed stone agg) in surface channels and drains incl demolition of existing concrete complete all as specified and directed.
S&F Solar road stud having 3 LED's of colours red/yellow/blue/green tough pressure dia casted aluminium alloy of size 125x125mm f height 20mm with fixing with epcxy, LED's solar cells battery & light sensor well protected in side under tough unbreakable poly carbonate transparent sheet roof system workable for 3-4 (nights) after full charge in 8-10hours including removal of old unserviceable stud. Make:- Dark Eye,3M, Tata BP Solar, Shakti Enterprises.
S&F cat eye's dual directional reflective of tough poly carbonate of retro reflective glass beads of colour white/red/yellow side provided with including removal of old unserviceable stud. Make:- Dark Eye,3M, Tata BP Solar, Shakti Enterprises.
S&F high intensity grade shedding retro reflective delinator post 75 mm outer dia, heavy duty steel pipe 1.2 m long head cap by hydraulic machine design and hold fast welded on delineator post bottom with one one coat of red oxide paint and two coats of stove enameled paint by heat process and three Nos reflective bands of white, red & yellow colour and covered by 14 gauge net grill and welded complete all as specified embedded in ground in 30x30x40cm deep pit (including excavation and removal of soil) filled with PCC 1:2:4 type B-1(using 20 mm graded crushed stone aggregate) and up to 30 cm high above ground level including necessary form work, removal of old unserviceable delinator complete all as spd and directed. Make:- Dark Eye,3M, Tata BP Solar, Shakti Enterprises.
Preparation of old or previously treated concrete/plastered surfaces of kerb stone of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any colour as decided by Engineer-in-charge complete all as directed.
Preparation of road surfaces and applying thermoplastic reflective paint in marking of minimum 2.5 mm thick single coat as in center line and edge line road marking of 150/100 mm width using 'HOT MARK'thermoplastic paint (Hot application) white/yellow by indigenous modern propelled road marking machine as directed including all ingredients such as blinder, glass beads, Titanium dioxide, calcium carbonate inter fillers, thermoplasstic requirement for glass beads shall be as per the table NO.800.4 of MOST specification including spraying of glass beads etc. complete all as per manufacture instructions and all as specified and directed.
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, holders and making good the disturbed surfaces in cement mortar 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed.
Material and labour for modular point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in and including concealed non metallic rigid PVC conduit not less than 20 mm dia with all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including inner and outer frame plate matching with surrounding with modular sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets,regulator etc complete for the following: Make of wire: Finolex,Havells,Bonton, Polycab,Make of conduit: Finolex, Ess Ess Kay, ICL,AKG Note: (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Six light point controlled by one, one way 6 Amp modular switch.
One light point controlled by one, one way 6 Amp modular switch.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board
One 5 pin 5/6 Amps socket outlet point on independent board
Description all as per item No. 34 here-in-before but point wiring with 2.5 Sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sq mm PVC insulated multistranded copper conductor cable as continous earth wire.
S & F Modular switch single pole one way 6 Amp fixed complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F for Modular switch single pole one way 16 Amp complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F Modular socket outlet 2/3 pin combined 6 Amp 240 volts fixed complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F fan regulator modular step type 120W 240 volts 2 module type complete all as directed. Make: Anchor, Bajaj, Crompton, Havells
S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor, Crab tree, Ess Ess Kay
S & F sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking Down old unsv submain wiring of following sizes complete all as specified and directed. Make: Finolex, Polycab, GEMSCAB, BONTON Note:Two/Four run of single core PVC cable with one run of earth conductor & conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral.
2 x 10 Sqmm + 1 x 10 sqmm
4 x 10 Sqmm+ 1 x 10 sqmm
S & F in repairs Distribution boards epoxy powder coated TP & N 4 Way VTPN DB (FP MCCB +12 MCB,C). fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt flush to wall and suitable for fixing FP MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings of 4 Way VTPN DB (FP MCCB +12 MCB,C) capacity including taking down old unsv MCCB DB,s complete all as directed.Make :legrand Cat No. 507745 equvilent in L&T, ABB, Schneider Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule)
S & F in repairs MCB DB 12way SPN DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door .The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed. All the above mentioned specs the technical documents from OEM shall be provided at the time of bidding of following capaity . Make: Legrand, L&T, ABB, Schneider
S & F in repairs MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 18 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity complete all as directed. Make: Legrand, L&T, ABB, Schneider
S & F in repairs MCB SP/TPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 100A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 100 A including connection with suitable size copper lugs complete all as directed. All the above-mentioned specs technical documents from OEM shall be provided at the time of bidding of following capaity. Make: Legrand, L&T, ABB, Schneider
MCB SP6 to 32 Amp.240 volts
MCB SPN 40 to 63 Amps 240 volts
MCB TPN 100 Amps, 415 volts
S&F Exhaust fan 300 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : Havells /Crompton /Bajaj
S&F Exhaust fan 450 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : Havells /Crompton /Bajaj
Material and labour for Earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.
S & F in repairs wall mounted Fan 400mm sweep ,2100 RPM high speed and 105CMM Air Delivery,strudy base and thermal overload protection ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, etc including taking down old unsv wall mounted fan complete all as specified and directed. Make : BAJAJ/HAVELLS /CROMPTON
Supply and Fixing in repair LED Batten light fittings on walls including brackets all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Syatem watt/Lumens: - Max-22 watts/total system lumen not less than 2200 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700( COOL DAY LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 20000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2.5KV (xv) Heat Shink: - As per OEM's design (xvi) Bidder has to compulsorily submit the data sheets conforming of technical spscifications. Make: - PHILIPS / BAJAJ / HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site.
Supply and Fixing LED Batten light fittings 2 Feet on walls including acessories all as conforming to the following parameters including taking down old unsv Light fitting: - (i) System watt/Lumens: - Max-12 watts/total system lumen not less than 1200 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700(COOL DAY LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 20000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2KV (xv) Heat Shink: - As per OEM's design (xvi) Bidder has to compulsorily submit the data sheets report conforming of technical spscifications . Make: - PHILIPS / BAJAJ / HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site.
Supply and Fixing Building security light fittings on poles/Wall including mounting brackets (32 mm MS pipe bend at 120 degree angle and 1.2 m long along with MS clamps to be fixed on wall all as conforming to the following parameters including taking down old unsv Light fitting : - (i) Syatem watt/Lumens: - Max-25 watts/total system lumen not less than 3000 lm (ii) Housing: - Single Piece High pressure die cast aluminium. (iii) IP Rating & IK Rating: - IP 66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - Suitable for pole mounting with bracket arm 40-50mm dia, Mounting height- 5.50m to 6.50 m from GL. (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 5700 (x) Color Rendering Index (CRI): - Not less than 70 (xi) Life: - Not less than 50000 Hrs of operation @ Ta 35*C (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattarn- Asymmetrical driveway. (xiii) Control gear: - inbuilt electronic driver with 325V Auto Cut off Restart feature & 440V Phase to Phase protection till 8 hour, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV. (xv) Heat Shink: - As per OEM's design Make: - PHILIPS /BAJAJ HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site.
Supply and Fixing LED 2x2 Recessed Mounted fittings on armstrong/Gypsum/POP Ceiling including all accessories and frame required for fixing the fitting including taking down old unsv recess mounted fitting all as conforming to the following parameters: - (i) Syatem watt/Lumens: - Max 30 watts/total system lumen not less than 3600lm (ii) Housing: - Single Piece CRCA body (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - On Armstrong/Grid Ceiling (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation @ Ta 35*C (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattarn- Asymmetrical driveway. (xiii) Control gear: - inbuilt electronic driver with 325V Auto Cut off Restart feature, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV. (xv) Heat Shink: - As per OEM's design (xvi) feature : ( COOL DAY WHITE ) or (WARM WHITE ) as required. Make: - PHILIPS/BAJAJ / HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site.
Supply and Fixing LED Round Surface Mounted Downlighter fittings on Ceiling including taking down old unsv LED down lighter all as conforming to the following parameters: - (i) Syatem watt/Lumens: - Max 18 watts/total system lumen not less than 2000 lm (ii) Housing: - Single Piece die cast aluminium body (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - On ceiling (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 110 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 30000 Hrs of operation. (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 20% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 2KV. (xv) Heat Shink: - As per OEM's design (xvi) ( COOL DAY WHITE ) or WARM WHITE as per requirement Make: - PHILIPS/ BAJAJ / HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site.
Supply and Fixing LED Flood Light fittings with complete fixing arrangemnets including taking down old unsv led flood light all as conforming to the following parameters: - (i) Syatem watt/Lumens: - Max 50 watts/total system lumen not less than 5000 lm (ii) Housing: - Single Piece Aluminium die cast body (iii) IP Rating & IK Rating: - IP66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - With complete fixing arangement, (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI) & SDCM: - Not less than 70, <5 (xi) Life: - Not less than 50000 Hrs of operation at Ta 45*C (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV. (xv) Heat Shink: - As per OEM's design Make: - PHILIPS / BAJAJ / HAVELLS / CROMPTON NOTE : (i) The Contractor has to make good of surface / ceiling damaged during fixing of the lights/fittngs as per existing surface/ceiling whatever it may be hence it is advised to visit the site before quoting rate. (ii) The contractor has to provide related T&P items required at site. (iii) The contractor has to make fixing arrangement of light in such a manner that light should focus on the playing surface.
Taking down ceiling fan and refixing the same after repairing in all respectcomplete all as directed.
M/S PUNDIR BUILDERS
Sharda Enterprises
Amit Traders
Sanjay Enterprises
M/S S P BUILDERS
M/s RAM RATAN AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .