Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
SPECIAL REPAIR/ REPLACEMENT OF DEFECTIVE INVERTER, DCDB, ACDB, CABLES AND CONNECTED ITEMS OF SOLAR PLANTS AT CERTAIN LOCATIONS AT INS GARUDA, NAVAL BASE KOCHI
2026_MES_787910_1
8720/E8
Open Tender
Civil Works
Item Rate
180 days
KOCHI
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹51,680
Yes
4 Sept 2026
4 Sept 2026
28 Sept 2026
4 Sept 2026
25 Sept 2026
19 Sept 2026
4 Sept 2026 - 5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,errection, installation,commissioning and testing of Solar Inverter of capacity 50 KW, IP 65 rating,BIS and IEC certified with LCD display for generation data, higher efficiency upto 98.9%, WiFi / GPRS Data Logger, RS485, 1.5 times DC Over loading per MPPT, Inbuilt type II - SPD for DC and AC side, Online software upgrade, 10 years of warrenty, including taking down old one complete all as specified and as directed
Location: - SFNA-2 Nos and AED P-198-1 Nos
Note: Contrcator shall submit warranty certificate for 10 years at the time of final bill. | 3 | Each | - | - |
| 2 | Supply,errection, installation,commissioning and testing of Solar Inverter of capacity 30 KW, IP 65 rating,BIS and IEC certified with LCD display for generation data, higher efficiency upto 98.9%, WiFi / GPRS Data Logger, RS485, 1.5 times DC Over loading per MPPT, Inbuilt type II - SPD for DC and AC side, Online software upgrade, 10 years of warrenty, including taking down old one complete all as specified and as directed
Location: - SNOM- 1 Nos and ATC P4 - 2 Nos
Note: Contrcator shall submit warranty certificate for 10 years at the time of final bill. | 3 | Each | - | - |
| 3 | Supply,errection, installation,commissioning and testing of Solar Inverter of capacity 20 KW, IP 65 rating,BIS and IEC certified with LCD display for generation data, higher efficiency upto 98.9%, WiFi / GPRS Data Logger, RS485, 1.5 times DC Over loading per MPPT, Inbuilt type II - SPD for DC and AC side, Online software upgrade, 10 years of warrenty, including taking down old one complete all as specified and as directed
Location: - AED P-198 - 1 Nos and ATD P-33 - 1 Nos
Note: Contrcator shall submit warranty certificate for 10 years at the time of final bill. | 2 | Each | - | - |
| 4 | Supply and fix in repair of DCDB suitable for capacity 50 KWp, IP 67 complete all as specified and as directed | 2 | Each | - | - |
| 5 | Supply and fix in repair of DCDB suitable for capacity 30 KWp, IP 67 complete all as specified and as directed | 2 | Each | - | - |
| 6 | Supply and fix in repair of DCDB suitable for capacity 20 KWp, IP 67 complete all as specified and as directed | 1 | Each | - | - |
| 7 | Supply and fix in repair of ACDB suitable for capacity 50 KWp, IP 67 complete all as specified and as directed | 2 | Each | - | - |
| 8 | Supply and fix in repair of ACDB suitable for capacity 30 KWp, IP 67 complete all as specified and as directed | 2 | Each | - | - |
| 9 | Supply and fix in repair of ACDB suitable for capacity 20 KWp, IP 67 complete all as specified and as directed | 1 | Each | - | - |
| 10 | Supply and laying in replacement of DC Cable 2 x 6 sq.mm multi stranded copper conductor 1100 volts with suitable cable lugs, MC4 connectors etc. complete all as specified and as directed | 1,500 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
COMMONPAGES_8720.pdf
Tender Documents • 0.53 MB
PS_8720.pdf
Tender Documents • 0.57 MB
BOQ_883081.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .