Loading…
Loading…
Tender Value
₹44.0 Cr
EMD Value
₹11 L
Closing Date
29 May 2026, 4:00 pmClosed
Additional Chief Engineer (P&C)
Supply, Erection, Testing, and commissioning of 220kV and 66kV equipments and materials on Turnkey basis including civil works for 220kV Sarvala AIS Substation
300110
ACE(P&C)/Contract/E-453/SS/220KV Sarvala
Open
Electrical Works
Turn-key
Vadodara
32 documents required · 27 mandatory · 5 optional
₹11,800
Gujarat Energy Transmission Corporation Limited
₹11 L
7 May 2026
7 May 2026
7 May 2026
29 May 2026
7 May 2026
Particulars of Item Unit
Supply, Erection, Testing and Commissioning of Protection equipments and
materials as per respective technical specifications and relevant special
conditions and suitable for One Main Bus and One Main cum Transfer Bus
system on 220 kV side
Control & Protection panels (having IEC 61850 Edition 2 as well as Cyber
1 security complient IEDs) for 220 KV Bays (Control Voltage - 220V DC) as per
tech specifications with following break up
1) Control & Protection panel for Line with Distance protection relays as Main-I &
2) Control & Protection panel for Transformer with Differential Set 2
3) Control & Protection panel for TBC Set 0
4) Control & Protection panel for BC cum TBC Set 1
5) Busbar Protection - (Central Unit - 24 bays, Peripheral Units - 07 Bays)
[CU shall be mounted in one of the bay control & protection panel while PUs shall
be mounted in respective bay control and protection panels as shown in panel GA
2 GPS based Time Synchronising Unit (IEC 61850 compatible) Set 1
Supply, Erection, Testing and Commissioning of Protection equipments and
B materials as per respective technical specifications and relevant special
conditions and suitable for Two main Bus system on 66 kV side
Control & Protection Panel (having IEC 61850 Edition 2 as well as Cyber
security complient IEDs) for 66 kV bays (Control Voltage - 220V DC) as per tech
specifications & with following break up
1) Control & Protection Panel for two Lines Set 2
2) Control & Protection Panel for Interconnecting Line & Line Set 0
3) Control & Protection Panel for Line & Buscoupler Bay Set 1
4) Control & Protection Panel for Transformer W/O Differential Relay (220/66KV
5) Control & Protection Panel for Tranformer with Differential Relay (66/11KV
6) Control & Protection Panel for Capacitor bank Set 0
7) Under Frequency Panel Set 0** 0**
Supply, Erection, Testing and Commissioning of Protection equipments and
C1 materials as per respective technical specifications and relevant special
conditions and suitable for Single Bus system on 11kV side
SCADA comaptible Control & Protection panels for 11kV Bays with Bay Control &
2 Protection Relay (Control Voltage - 220V DC) as per tech specifications & suitable
for conventional switchgear modules with following break up
1) Control & Protection Panel for 66/11kV TRF LV Set 1
Supply, Erection, Testing and Commissioning of General purpose
equipments and materials as per respective technical specifications and
D relevant special conditions and suitable for One Main and One Main cum
Transfer Bus system on 220kV, One main Bus system on 132kV and Two
Main Bus system on 66kV.
Battery set - 220 V, 250Ah at ECV -1.14, C5 Duly cycle {1.2 V, 174 cells}
Ni-CAD Battery Set with Two Step Two Tier FRP stand of adequate size.
Battery set - 220 V, 250Ah at ECV 1.85V {2 V, 110 cells} Plante' type Lead Acid
Battery Set with Two Step Two Tier FRP stand of adequate size
Sr. Erection Supply
Particulars of Item Unit
Battery Charger - 220 V (Float - 30A / Boost - 60A) - (SCADA compatible)
Suitable to Ni-Cd Battery set and shall be able to charge Battery set as per
requirement during float / boost mode as well as it shall supply to load as per rated
voltage of load components.
3 DCDB-220 V with 35 Feeder(For 66kV System) No. 2
4 DCDB-220 V with 20 Feeder(For 220kV System) No. 2
4a DCDB-220 V with 20 Feeder (For 220kV PLCC Panels) No. 2
SCADA compatible 400A, LTPB suitable for AIS switchgear module and related
5 accessories as per specifications but not less than the requirement of No. 2
Supply, Installation, Testing and Commissioning of materials/item for Power
Cable and Control Cable wiring including preparation of wiring schedule.
Supply and Laying of 1.1 kV PVC armoured copper/Aluminium control/LT power
cable in trench including binding/clamping of cable with PVC lockable wire tie as
1 per requirement including supply and fixing of identification tags at both ends and
at distance of every 100mtr.
(Note :- Aluminium cables of size 185 mm2 & above shall be XLPE type)
1) 2c x 2.5 mm2, armoured copper control cable Mtr. 2000# 2000#
2) 2c x 4 mm2 , armoured copper control cable Mtr. 1800# 1800#
3) 4cx2.5 mm2, armoured copper control cable Mtr. 7300# 7300#
4) 4c x 4 mm2 , armoured copper control cable Mtr. 7600# 7600#
5) 7c x 2.5 mm2, armoured copper control cable Mtr. 2200# 2200#
6) 12c x 2.5 mm2, armoured copper control cable Mtr. 5800# 5800#
7) 12c x 4 mm2, armoured copper control cable Mtr. 4300# 4300#
8) 19c x 2.5 mm2 , armoured copper control cable Mtr. 9800# 9800#
9) 27c x 2.5 mm2 , armoured copper control cable Mtr. 4300# 4300#
10A) 1 x 50 mm2 , armoured copper cable Mtr. 2000# 2000#
10B) 4C x 10 mm2 , armoured copper control cable Mtr. 400# 400#
11) 4 x 10 mm2 , Al. armoured LT cable Mtr. 400# 400#
12) 3.5 x 25 mm2 , Al. armoured LT cable Mtr. 1000# 1000#
13) 3.5 x 50 mm2 , Al. armoured LT cable Mtr. 300# 300#
14) 3.5 x 120 mm2 , Al. armoured LT cable Mtr. 0
15) 1C x 150 mm2 , Al. armoured LT cable Mtr. 1100# 1100#
16) 1C x 240 mm2 , Al. armoured LT cable Mtr. 0
17) 1C x 300 mm2 , Al. armoured LT cable Mtr. 0
18) 3.5 x 300 mm2 , Al. armoured LT cable Mtr. 0
Termination of the Control and Power cable at panel / MK box/equipment including
PVC binding, dressing, shaping, drilling of holes in panels for glands nuts
includings supply of all required materials, providing of glands for following size.
The work also includes looping in Panel and MK box by using crimping type lugs of
suitable size with ferruling (machine printed) with proper size of copper cable wire.
The loops should be bunched by using button tape and proper shaping etc.
1) cables from 2 core to 7 core of 2.5 & 4.0 Sq.mm size No. 1150#
2) cables above 7 core No. 1300#
Sr. Erection Supply
Particulars of Item Unit
Laying of 1.1kV PVC/XLPE armored Al. LT power cable in ground by digging
trench of suitable width and 450 mm depth with providing and fixing of brick and
sand layer covering the cable in any type of soil and Laying of 1.1kv PVC armored
copper control cable in heavy duty PVC pipe of suitable size buried in ground by
3 digging trench of suitable width and 450 mm depth in any type of soil including
supply and fixing of Pipe and identification tags at distance of every 100 Mtrs for
1) Control Cables upto 7 core Mtr. 2050#
2) Control Cables above 7 core and all LT cables Mtr. 2500#
Supply, Erection, Testing and Commissioning of Modular Variable-diameter Cable
sealing system as per respective technical specification and relevant special
3a conditions wherever the electrical / instrumentation / communication / LT Power Job LS LS
cable underground and over-ground enter or leave bay kiosks / control room of
substations / cable trench / basement. *
Providing and fixing of suitable BOX type GI perforated tray with necessary clamps
and couplings for control cable of CT/PT/CVT etc. equipments including fixing
with structures up to plinth level as per instruction of Engineer-in-charge.
1) 220 KV Switch Yard Mtr. 150
2) 132 KV Switch Yard Mtr. 0
3) 66 KV switch Yard Mtr. 135
Providing and fixing of suitable BOX type GI perforated tray with necessary clamps
and couplings for control cable of CB, Isolator, Earth Switch etc. equipments
including fixing with structures up to plinth level as per instruction of Engineer-in-
1) 220 KV Switch Yard Mtr. 150
2) 132 KV Switch Yard Mtr. 0
3) 66 KV switch Yard Mtr. 125
5 Providing and fixing bay MK as per tech spec No. 7
Providing and fixing Yard LT ACDB as per tech spec -with 20 OG feeders
7 Providing and fixing Yard LT ACDB as per tech spec -with 12 OG feeders No. 0
8 Providing and fixing of CT-PT/CVT JB as per Technical specification
2) CT JB (66kV Yard - 10 Nos., 11kV Yard - 1 No.) No. 11
3) CVT JB No. 0
1.# The quantities of control and power cables shown in the BOQ are based on typical cable philosophy.
Hence, the contractor shall work out actual requirement of quantity for execution by calculating cable lengths.
2. All the cables shall be laid through minimum possible route and accordingly the quantity of cables shall be
calculated and considered as per actual measurement. Any adjustment found during execution is to be
absorbed and final amendment of quantity shall be based on approved 'As Built' quantity.
3.**Under Frequency (UFR) protection Panel is not considered as per O.N. No: GETCO/OTHER/e-
file/447/2024/5456/Technical Dated:26.03.2024
4.* The cable sealing system Module quantity & Frames are standardized as per O.N. No: GETCO/
CE(Engg)/V/C /O-006881 Dated:17.06.2021
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
160. EMD BG Format.pdf
3.Ammendment -1 of Part-1 E-453.pdf
4.PP-220kV Sarvala AIS.pdf
5.BOQ SWITCHYARD 220kv Sarvala SS.pdf
6.BOQ PROTECTION 220kV Sarvala SS.pdf
7.BOQ SCADA 220kV Sarvala SS.pdf
8.BOQ FOTE 220kv Sarvala SS.pdf
9.BOQ Telecom 220kV Sarvala SS.pdf
10.BOQ Switchyard item Breakup 220kV Sarvala ss.pdf
11.BOQ Annexure ABCD.pdf
12.BOQ Annexure-4 of 220kV Sarvala ss.pdf
13.BOQ Annexure 5 of 220kV Sarvala ss.pdf
14.BOQ Civil 220KV Sarvala SS.pdf
15.BOQ Civil Itemwise 220KV Sarvala SS.pdf
16.220Kv Sarvala SS CIVIL Technical Specification.pdf
17.Approved_220kV SARVALA SS_ALL DRG BINDER 01 to 25.pdf
18.Approved_220kV SARVALA SS_ALL DRG BINDER 26 to 50.pdf
19.SBC Sarvala ss (Geo-Technical investigation report).pdf
20.TS SS STR R12 11.03.2024.pdf
21.Amendment- Structure weight.pdf
22.1CX50 sq mm Amendment 1 Publish LT Control and Power Cable GTP.pdf
23.11kV_XLPE CABLE R2 Feb.23.pdf
24.66KV 630SQ MM 1C POLY AL POLY UG Cable R4 July 22.pdf
25.ACSR cond MOOSE ZEBRA PANTHER DOG -R5-July 22.pdf
26.AL59 ZEBRA and MOOSE GETCO- R4 July 22.pdf
27.EARTH WIRE - R5.pdf
28.EARTH WIRE ACCESSORIES 7-3.15-R2.PDF
29.FIRED WEDGE CONNECTOR_R2 Mach- 23.pdf
30.G.I. EARTHING STRIPS.PDF
31.HW and ACCS AL59 CONDUCTOR - R2 JULY 2022.pdf
32.LT CONTROL and POWER CABLE - R4 SEPT 2025.pdf
33.MQP GI Steel Str-compressed.pdf
34.MS PLAIN and TOR BAR.PDF
35.R1 - STEEL DRUM.pdf
36.R5 - ACSR cond MOOSE ZEBRA PANTHER DOG.pdf
37.R5 May 24- Silicon Rubber.pdf
38.SS HW 220 and 400KV SS R2.PDF
39.Standard MQP GI Tower material for issuence to SUPPLIER COPY.PDF
40.TS LAYING CABLE 66KV R2 July 2018.pdf
41.11 22 33 KV LA R2 July-23.pdf
42.33 22 11 KV ISO R4 June-22.pdf
43.66 kV and 33KV TRF Specification R14 Jun 22.pdf
44.66 kV CT and PT R8 plus metering Jun-22.pdf
45.66 kV Isolator R6 June- 22.pdf
46.66 KV LA R6 June 22.pdf
47.220 132 66 KV LA Model (1).pdf
48.220 132 KV and 66kV CB (R5) with FDN plan.pdf
49.220 kV CT and PT R10 Jun -22.pdf
50.400 220 132 66 KV BPI R4 June-22.pdf
51.400 220 132 kV LA R6 June 22.pdf
52.400 220 132 kV DB Tandem Isolator R6 June 22.pdf
53.Addendum terminal connector 10.06.2025.pdf
54.Amendment Dist TRF - 1.pdf
55.Amendment 66KV TRF Nov 24.pdf
56.Amendment for TTR validity 26.02.2026.pdf
57.Amendment to 66 KV Isolators (R6) 22.06.2023.pdf
58.Amendment to 220 kV CT (R10) Clause - 2.3.1 -13.pdf
59.Dist_Trans_63KVA to 500KVA_R5 Aug 22.pdf
60.Terminal Connectors R2 June 22.pdf
61.Typical 66kV (HV) TRF Bay view (AIS).pdf
62.Typical 66kV (LV) TRF Bay view (AIS).pdf
63.Typical 66kV BUS COUPLER and PT BAY AIS.pdf
64.Typical 66kV LINE AIS.pdf
65.Typical 66kV Single Line Diagram (AIS) SLD.pdf
66.Typical 220kV BUS COUPLER CUM TBC and PT BAY (AIS).pdf
67.Typical 220kV Line (AIS).pdf
68.Typical 220kV Single Line Diagram (AIS) SLD.pdf
69.Typical 220kV TRF (HV) Bay view (AIS).pdf
70.Typical Battery Charger Control View.pdf
71.Typical BUSBAR Monitoring View.pdf
72.Typical Kiosk Monitoring View.pdf
73.Typical Pop-Up Window for 220kV TRF (HV)Bay view (AIS).PDF
74.Typical Station AUX. Monitoring View -1.PDF
75.Typical Station AUX.Monitoring View -2.pdf
76.(AC) POWER CABLE BLOCK DIAGRAM -Model.pdf
77.(DC) POWER CABLE BLOCK DIAGRAM -Model.pdf
78.66KV PT-AC-DC DISTRIBUTION.pdf
79.220kV PSLD-Model.pdf
80.220KV PT-DISTRIBUTION.pdf
81.220KV SS LT PANEL SYSTEM-Model.pdf
82.CONTROL ROOM EQUIPMENT ARRANGEMENT.pdf
83.final Board Formation and Panel Arrangement in Yard Kiosk-Model.pdf
84.SCADA FO NETWORK R0-Model.pdf
85.STN. AUX. and PLCC BCU CONTROL CABLE BLOCK DIAGRAM -Model.pdf
86.TYP.CABLE BLOCK DIAGRAM (66KV)-Model.pdf
87.TYP.CABLE BLOCK DIAGRAM (220 KV )-Model.pdf
88.AUTOMATION PHILOSOPHY.pdf
89.PROTECTION PHILOSOPHY.pdf
90.Addendum - I - Bay Control and Protection Relays specification.pdf
91.Addendum - I - SAS and SAS Equipments R10 March 2026.pdf
92.Addendum - I to C and P Panel spec R7.pdf
93.Ammendment for TTR validity 26.02.2026.pdf
94.Final TS - SAS and SAS Equipments - R10 March 2026.pdf
95.General Technical Requirement of SCADA Furniture R0.pdf
96.TS - GPS based Time Synchronization Equipment R2 July 22.pdf
97.TS - 110-220V DCDB.pdf
98.TS - AC System for Kiosk - R1 June 22.pdf
99.TS - Bay Control and Protection Relays (IEDs) R2.pdf
100.TS - Bay MK - R2 June 22.pdf
101.TS - Cable Sealing System Specification.pdf
102.TS - CT-PT-CVT JB - R1 June 22.pdf
103.TS - FOC - R2 June 22.pdf
104.TS - General Technical Requirement of YARD KIOSK - R2 June 22.pdf
105.TS - Yard LT ACDB - R2 June 22.pdf
106.TS For 765 400 220 132 66 33 and 11 kV C and P panel.pdf
107.TS for Ni-Cad Battery Set-R3 Feb 25.pdf
108.TS for Plante Type Lead Acid Battery sets R2 Feb 25.pdf
109.TS_220V Battery Chargers - R4 Feb 25.pdf
110.TS_LT Panel board 400A_R5_April 2025.pdf
111.TS_Protection Relays for 11_22kV System R1_060822.pdf
112.R0 LAYOUT PLAN OF 220KV SARVALA SS.pdf
113.R0 LAYOUT SECTION OF 220KV SARVALA SS.pdf
114.R0 SLD OF 220KV Sarvala SS.pdf
115.EARTHING NOTES-Model.pdf
116. EARTHING NOTES-Model.pdf
117A.EARTHING NOTES-Model.pdf
118B.EARTHING NOTES-Model.pdf
119.Typical Arrangement of Riser for Earthing System-Model.pdf
120. Typical Arrangement of Welding Joint(NEW)-Model.pdf
121A Typical Arrangement of Welding Joint(NEW)-Model.pdf
122. R2 Lightning Arrestor DT 22.12.2025-Model.pdf
123. R2 EARTHING ARRANGEMENT FOR CVT-PT DT 22.12.2025-Model.pdf
124. TYPICAL EARTHING ARRANGEMENT FOR CT-Model.pdf
125. TYPICAL EARTHING ARRANGEMENT FOR ISO.-Model.pdf
126. Typical Earthing Arrangement for Circuit Breaker-Model.pdf
127. TYPICAL EARTHING ARRANGEMENT FOR BPI-Model.pdf
128. R2 Typical Earthing Arrangement for Power Transformer.pdf
129A. Typical Earthing Arrangement for LT Transformer-Model.pdf
130. TYPICAL EARTHING ARRANGEMENT FOR TOWER WITH PEAK-Model.pdf
131. TYPICAL EARTHING ARRANGEMENT FOR TOWER WITHOUT PEAK-Model.pdf
132. TYPICAL EARTHING ARRANGEMENT FOR LM-Model.pdf
133.EARTHING ARRANGEMENT FOR EQUIPMENT OF CAPACITOR BANK.pdf
134. TYPICAL EARTHING ARRANGEMENT FOR BMK-Model.pdf
135. DETAILS OF PANEL EARTHING-Model.pdf
136. TYPICAL EARTHING ARRANGEMENT OF CABLE TRENCH-Model.pdf
137. DETAILS OF EARTHING FOR D.P.STRUCTURE-Model.pdf
138. Typical Earthing Arrangement for Switch Yard Gate-Model.pdf
139.SLIDING GATE-Model.pdf
140.Connection of Four Electrode Method Soil Resistivity.pdf
141. MEASUREMENT OF EARTH RESISTIVITY-Model.pdf
142.MAINTENANCE FREE EARTHPITS (ROCKY SOIL) R4 22.12.25-Model.pdf
143.Standard Guideline for Earthing of EHV SS R4 Dtd.30.12.25.pdf
144.TYPICAL ARRANGEMENT OF EARTH TEST PIT(CHEAK PIT)-Model.pdf
145.Ann-E Adaquacy of earthing 140415.pdf
146.DG-Incomer arrangement.pdf
147.Technical Specification of Solar System.pdf
148.TS- AIO -Desktop and printer-30.04.2025.pdf
149.TS- AIO -Desktop and printer-Updated.pdf
150.TS FPE R1 Feb13.pdf
151.TS General Erection R1.pdf
152.TS Illumination System R9 Dtd.30.12.25.pdf
153.TS VMS R1 Dtd.30.12.25.pdf
154.TS-Insulating Mat 270312.pdf
155.TS-Maintenance Free Earthpit 040615.pdf
156.220 KV CVT with HPI- R5 Jun 22.pdf
157.DAS Communication Cable and RS 485 to RS 232 Converter.pdf
158.Static Meter-specification-R3 July 2022.pdf
159.TS VMS R1 Dtd.30.12.25.pdf
160. EMD BG Format.pdf
161. SD cum PBG Format.pdf
162.Form for Networth Annual turnover LA.pdf
2.Part 1 Tender Specifications E-453 220KV Sarvala SS.pdf
1.Tender Notice E-453 220KV Sarvala SS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .