Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.4 L+₹490 (0.35%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.4 L+₹698 (0.50%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹2,800
Closing Date
14 Feb 2025, 2:00 pmClosed
AE/BESD-I/PWD, PURTA BHAWAN, ROOM NO-14, SALT LAKE
AE/BESD-I/PWD, PURTA BHAWAN, ROOM NO-14, SALT LAKE
Supply, Installation, testing and commissioning of split type AC at server room of Maulana Abul Kalam Azad Bhawan, DD 45, Sector I, Salt Lake City, Kolkata 64
2025_WBPWD_807037_1
WBPWD/AE/BESD-I/eNIQ08/24-25 2nd call
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Maulana Abul Kalam Azad Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,800
AE/BESD-I/PWD, PURTA BHAWAN, ROOM NO-14, SALT LAKE
28 Feb 2025
27 Jan 2025
17 Feb 2025
4 Feb 2025
14 Feb 2025
7 Feb 2025
5 Feb 2025
Amount
Supply, Installtion, Testing and Commissioning of Split typc A C machines having Cooling Capacily range (5.2kw - 5.6kw) with fixed speed rotary compressor, refrigerant gas R31 / R410 BEE star rating - 3 (EER range 3 .5 to 3.99), Air flow range CFM ( 550 - 765), both condcnser and cooling coils made of copper tube connecting chord with plug top conforming to IS 1391 (Part - I & Part - II) with all amendments ( Make Mitsubishi Electric /Mitsubishi Heavy/ O-General).
SITC including vaccumiazation and Nitrogen testing of following nominal size of soft /hard drawn copper refrigerant piping for package/ VRV/VRF/RAC system, complete with fittings, with adjustable ring type hanger supports, jointing /brazing including accessories, insulated with XLPE class O tubular insulation /with Class-O closed cell elastomeric nitrile rubber tubular sleeves of specified thickess as given below for suction and liquid lines, all accessories as per specification etc. as required. (i) S&F of 5/8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19mm thick insulation.
(ii) S&F of 1/4" ( 6.44 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19mm thick insulation.
Supplying and laying PVC drain water pipe, 25 mm dia with 6mm thick Nitrill rubber insulation. (Make : Suprime/Oriplast).
Supplying, fabrication & fixing of M.S "U"channel of 6 mm thick of size (75 mm X 40mm X 40 mm) for making base frame/ platform for installation of outdoor unit of above mentioned AC, machines incl. drilling 2 nos holes in each channel , cutting holes into the wall & grouting the same with cement concrete (1:1½:3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm and supporting angle of 50mm x 50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 2 nos (50 mm xSOmm x6 mm) angle inserted into the existing wall incl. fiber sheet shade as per Dijrction of EIC. The entire struture must be safe to carry out maintenance of ODU as per bircmon of E.I.C..
S & F 1.1KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable for Indoor to outdoor connection as per direction of EIC.
(Note :- Rate should be quoted inclusive of all taxes and duties including G.S.T.)
DAS REFRIGERATION CO. (BID ID -6115155)
BARSHA ENTERPRISE (BID ID -6115134)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .