Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹57.8 L+₹3.3 L (6.10%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹60.7 L+₹6.2 L (11.5%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹66.6 L+₹12.1 L (22.2%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
24 Aug 2021, 6:00 pmClosed
CWE AF AMBALA
CWE AF AMBALA AMBALA CANTT 133001
SPECIAL REPAIR TO CERTAIN BUILDGS AT AMBALA UNDER GE (AF) AMBALA
2021_MES_457369_1
CWE/AF AMB/AMB-21/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Ambala cantt
For enlisted in MES Class C and above category a i and for unenlisted refer NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE AF AMBALA
₹1.4 L
Yes
6 Oct 2021
6 Jul 2021
26 Aug 2021
6 Jul 2021
24 Aug 2021
10 Aug 2021
6 Jul 2021 - 16 Jul 2021
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, fixed in any position with screws including cover fillets & electrical wiring, fitting, fitments if any and making good including dismantling/taking down of GI frame work/snap grid above false ceiling complete all as specified and directed. Note:- Electrical wiring, fitting, fitments etc (if any) shall be made good by contractor without any extra cost to department.
Supply and fixing powder coated GI frame work for seamless ceiling making the grid of size 605mm x 605mm, comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screw at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 mtr length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 6 mm dia GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mm x 3mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including 9mm to 10mm thick ceiling tiles/boards for insulation and accoustic purpose of size 600mm x 600mm decorative type with silver foil coating on back side fixed with staples with on snap grid and 4mm dia GI wire complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layers on roof and rubbish off the premises including stacking of servicable brick tiles complete all as specified and directed.
Demolition of mud phuska on roofs, any thickness including mud plastering & leeping (whether full thickness removed or only a part thereof) and rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and directed
Material and labour Atactic Polypropylene (APP) polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster (Weight not less than 150 gms per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.30 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP complete all as specified and directed . Notes:- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. 5% amount of the total amount of water proofing treatment (BOQ item No 3.00 to 9.00) shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Material and labour 40 mm thick brick tiles laid on roofs, jointed and grouted flush in cement mortar 1:3 mixed with linseed/crude oil @ 5% by weight of cement over and including 15 mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
Description all as per item No 7.00 here-in-above but except brick tiles. Note: Old serviceable brick tiles retrieved from item No. 3.00 here-in-before shall be used after cleaning and washing.
Material and labour Plain Cement Concrete 1:2:4, type B-0 (using 12.5 mm graded mechanically crushed stone aggregates) over roof slab as in padding in slope to make good the depressions/undulations complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness(below or above ground level) rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and directed.
Material and labour 100mm thick PCC 1:3:6, type C2, using 40mm graded mechanically crushed stone aggregate as in floor & paving complete all as specified and directed.
Material and labour 100mm thick PCC 1:2:4, type B1, using 20mm graded mechanically crushed stone aggregate as in floor & pavings including finishing even and smooth without using extra cement complete all as specified and directed.
M&L 75mm thick PCC 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length,12 mm wide. (ii) 50 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
S&F plain AC board 6mm thick strips upto 100mm depth, inserted in postion complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness as in floors, aprons etc, laid, bedded & pointed in any mortar and rubbish off the premises complete all as specified and directed.
Material and labour 100mm thick PCC 1:4:8, type D2, using 40mm graded mechanically crushed stone aggregate as in sub bases of floor complete all as specified and directed.
Material and labour 80mm thick prepolished, rubber moulded, double glossy, coloured designer interlocking tiles made of M-40 PCC design mix concrete of approved design & shape with crushing strength not less than 400 Kg per Sqcm complete all as specified and as directed.
M&L sand filling under floors/pavements or in foundations including watering and consolidation complete all as specified and directed. Note: Consolidated thickness shall only be measured.
Material and labour PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
Material and labour machine cut Kota stone slab 18mm to 20mm thick (slab size 550mm x 550mm) as in flooring, laid over and including 15 mm thick screed bed in cement mortar 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Material and labour machine cut Kota stone slab 18mm to 20mm thick as in skirting / dado, steps, laid over and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Material and labour machine cut Granite stone slab/tiles, 18mm to 20 mm thick, table rubbed and polished, as on shelves/ cooking platform/steps/pillars etc, like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20 mm thick screed bed or bedding layers in cement mortar 1:4, set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and any position not otherwise specifically provided including rubbish off the premises to a distance not exceeding 500 mtr complete all as specified and as directed.
Material and labour Precast cement concrete, 1:2:4, type B-1 using 20 mm graded mechanically crushed stone aggregates set in cement mortar 1:6 as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed. Note : The quoted rates include for use of formwork (straight or curved).
M&L mild steel TMT bars, 10 mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L demolition of damaged portion of RCC thin section such as chajja, drops, roof projection etc.and repairing with cement mortar 1:3 to the entire satisfaction of Engineer-in-chage complete all as specified and directed.
M&L PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. Note : The quoted rates include for use of formwork (straight or curved).
Material and labour PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregates as in beds of surface channels & drains including smooth finish complete all as specified and directed.
Material and labour extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed.
M & L for cutting/Chipping the spalling concrete surfaces of columns beams, slabs etc and trimming & cleaning the surface to recieve gunting applying epoxy treatment for bonding new or old concrete surfaces prior to gunting, applying chemical as per manufacture instruction and providing pressure gunnting average 25mm thick in cement mortar 1:3 for slab/cloumns complete all as specified and dirceted including providing scaffolding as required and removal the same on completion of the work including scaffolding and welding the reinforcement to existing reinforcement and finishned the surface fair and even. Note: Reinforcement shall be measured seperately.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed.
S&f Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&f 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Supply and fixing prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Note:- The net area of sheeting as fixed shall be measured on the flat (not girthed to corrugations) without any extra allowance for lapse.
Supply and fixing prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, gulley, gutter, ridges etc. fixed with self tapping screws complete all as specified and as directed.
M&L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
M&L 6mm thick asbestos cement, two piece adjustable serrated ridges, corrugated or semi corrugated sheets in roofs, walls etc. fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
Supply and fixing sheet glass 4.0 mm thick ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, rubbish off the premises complete all as specified and as directed.
Material and labour 25mm thick PCC 1:2:4, type B1, using 20 graded mechanically crushed stone aggregate as in subbase complete all as specified and directed.
Material and labour coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:4, complete all as specified and directed.
Material and labour glazed desinger ceramic coloured tiles of size 300mm X450mm, 7-8 mm thick on vertical surface as in skirting/dado, set and jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Material and labour coloured, non-skid, jointfree, ceramic tiles, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18Sqm but not exceeding 0.38 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layers in cement mortar 1:4, complete all as specified and directed.
S&F in replacement sink with drainage board made of stainless steel 1.00 mm thick steel sheet, kitchen or laboratory with plug & chain, waste coupling, washers and 32 mm bore PVC waste pipe including bedding in cement mortar to dwarf wall or including fixing cantiliver MS brackets and connecting union to pipe, over all size 1145mm x 510mm & bowl size 560mm x 410mm x 200mm complete all as specified and directed.
S&F in repair vitreous china wash hand basin, coloured & oval type, size 550x490mm including 32mm bore PVC waste pipe and CP waste fitting and a pair of mild steel angle iron/ PVC brackets of suitable size fixed as in counter slab complete all as specified and as directed.
Taking down steel tubing and connections for refixing or removal from site for 15 mm bore pipe complete all as specified and directed.
Taking down steel tubing and connections for refixing or removal from site for 20 mm bore pipe complete all as specified and directed.
S&F GI tubes 15 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
S&F GI tubes 20 mm bore, medium grade, galvanised with all fittings and fixed complete to wall and ceiling with and including cutting chasing whereever required or laid in floor complete all as specified and directed.
M&L in repair cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), outlet dia 75 mm complete all as specified and directed.
Supply and fixing in repair 15 mm bore stop valves, concealed type, cast copper alloy, fancy type, chromium plated with long shank and cup, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe including cutting chases required for concealing complete all as specified and directed.
Supply and fixing in replacement vitreous china wash down water closet (Pedestal pattern), white, including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom, aluminium hinging devices and EWC jet (health faucet) , chromium plated, fancy type, 15 mm bore with 1 mtr long PVC connection pipe including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.
Supply and fixing in replacement PVC low level flushing cistern, white, valveless syphonic action type 10 litre capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified and directed.
S&F in repair 15 mm bore pillar tap, cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair bib taps, 15 mm bore, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair chromium plated, brass, tubular towel rail, fancy type, with fancy type brass CP brackets on both sides, 20mm dia, D type 600mm long between flanges , fixed with screws complete all as specified and as directed.
S&F in repair 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe including cutting chases required for concealing complete all as specified and directed.
S&F in repair PVC connection 600mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified and directed
S&F rotational moulded polythene(PVC) water storage tank, HDPE, off white colour, triple layered , cylinderical type fixed and hoisted in position on roof, at any height, of capacity 500 ltr and making connections with 20 mm GI pipe inlets & outlets complete including locking arrangements and 20 mm bore ball brass valve high pressure with polyethylene float including dismantling of water tanks from any position/location, and removing to store, capacity exceeding 500 Ltr & not exceeding 1000 Ltr complete all as specified and as directed.
S&F in repair curtain rails of stainless steel with fixing brackets, stops, rollers etc. complete all as specified and directed.
Dismantling/taking down of PVC (SWR) pipe of any dia and from any position including joints etc complete all as specified and directed.
Supply and fixing PVC (SWR) pipe 110 mm bore, single socketed in any length with rubber ring joints, fixed to wall/floor complete all as specified and directed.
Supply and fixing PVC (SWR) pipe 75 mm bore, single socketed in any length with rubber ring joints, fixed to wall/floor complete all as specified and directed.
Supply and fixing PVC pipe 40 mm bore for spouts including necessary bends/sockets complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl fixed with adhesive complete all as specified and directed.
S&F in repair 75 mm dia outlet PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius provided without access door complete all as specified and as directed.
S&F 75mm bore PVC (SWR) bends any radius provided without access door complete all as specified and as directed.
Taking down chowkhats or frames exceeding 1.50sqm but not exceeding 4.0sqm each with shutters (without taking off shutter from frames) removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and directed
Taking down chowkhats or frames not exceeding 1.5 sqm each with shutters (without taking off shutter from frames) removing from site including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and directed
M&L second class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed
Dismantling of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles complete all as specified and as directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Description all as per item No 76.00 here-in-above but except brick. Note: Old serviceable brick tiles retrieved from item No. 75.00 here-in-before shall be used after cleaning and washing.
Taking down cement plaster on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance not exceeding 500 mtr complete all as specified and directed.
Material and labour rendering 15 mm thick in cement mortar 1:6, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces complete all as specified and directed.
Material and labour rendering 10 mm thick in cement mortar 1:4, finished even and smooth without using extra cement on fair faces of brick or concrete surfaces complete all as specified and directed.
Material and labour rendering 5 mm thick in cement mortar 1:3, finished even and smooth without using extra cement on fair faces of concrete surfaces as in ceiling complete all as specified and directed.
M&L for rough cast plaster including 15mm thick rendering in cement mortar 1:3 on brick wall or concrete concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required ) mixed with course sand and cement in the ratio of 1 : 1 : 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered.
Material and labour for preparing newly plastered surface of walls and applying two coats of exterior acrylic emulsion paint over a coat of primer in camoflaging pattern of any shade and pattern complete all as spcified and directed
Material and labour preparation of newly plastered surfaces of wall, applying one coat of wall care putty(3mm thick) to make the surface even & smooth and applying two coats of distemper oil emulsion of approved shade/tint, complete all as specified and as directed.
Complete removal of existing treatment and applying two coats of distemper oil emulsion of approved shade/tint over & including one coat white wall care putty(3mm thick) as specified to achieve smooth finish surfaces of walls complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
Material and labour for complete removal of existing treatment of wall and applying three coat of white wash complete all as specified and directed.
Material and labour preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
Material and labour for complete removal of existing treatment on ceiling and applying three coat of white wash complete all as specified and directed.
M&L preparation of new wood and wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over & including one coat of pink primer complete all as specified and directed.
M&L preparation of old painted wood and wood based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparaion of old or previously untreated surfaces of RCC/stone/concrete/bricks/asbestos cement sheets or plastered surfaces and applying one coat of exterior acrylic emulsion paint (water based) in camouflaging pattern of any shape and to any pattern etc complete all as specified and directed.
M&L preparation of old painted steel and iron based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified and directed.
S&F in repair 18/19 mm thick block board, grade two quality, interior grade, commercial type, fixed with screws to frame work complete all as specified and directed.
S&F 40mm dia cup board knobs fixed with nut and washers of mild steel bright finish complete all as specified and directed. .
Supply and fixing contineous (piano) hinges mild steel bright finish or electrogalvainsed with width of flap 40mm complete all as specified and directed.
S&F decorative laminates 0.9 mm thick, type 1 of any tint/design/pattern as approved & fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supply and fixing rolled mild steel work in tubular trusses including vertical member, rafter and purlin including special shaped washer etc using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St- 240 including cutting to dead length, notching, drilling riveting and/or welding & connecting with nuts & bolts complete all as specified and directed.
Supply and fixing mild steel framed work as in door or gate of angle or other sections with gusset plates, rails, braces etc, using ornamental design as approved complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides and hanging, fastening and fixing complete conforming to Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
Taking down of existing mild steel shutters including frame, area exceeding 5.50sqm and not exceeding 6.00sqm and refixing the same after repairing, welding of new hold fast, pintle hing, re-allignment of defective/bended angle iron or other section including cutting to required size, removal of old wall clading and supply and fixing 1.0mm thick plain black mild sheeting, painting with two coats of synthetic enamel paint over & including one coat of redoxide primer after preparation of new steel surfaces and one coat of synthetic enamel paint after preparation of old steel surface, providing PCC 1:2:4 type B1 as in holdfast and making good to match the existing surface complete all as specified and directed. Note: Painting on steel surface as described above and PCC for holdfast are deemed to be included in quoted rates.
Supply and fixing factory made, second class, hard wood, plain framed, panelled shutter (two panel), 35 mm thick with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Supply and fixing second class, hard wood, glazed and skeleton shutter, 35mm thick, factory made, open rebated and prepared to receive glass/guage etc, without sash bars, mitred and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/guage etc, sizes of stiles, rails etc as specified in Section 8, clause 8.24(a) of SSR part-I(2009) complete all as specified and directed.
S&F Solid PVC Door Frame of size 100mm x 60mm made out of 5mm wood grain printed PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with printed sheet, reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet & 5mm thick x 15mm wide PVC sheed beading used insied Stiles and Rails and decorative PVC beading of 10mm x 10mm (90*) used instead of exposed portion of PVC sheet beading and the paneeling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F 100 mm size, MS butt hinges, medium weight, cold rolled, fixed complete all as specified and directed
S&F 150 mm long, aluminium, anodized, barrel tower bolt of extruded section complete all as specified & directed
S&F 150 mm size, aluminium alloy, handle, fabricated type, anodized fixed complete all as specified and directed
S&F 300 mm long, aluminium alloy, anodized, sliding door bolt with hasp , staple (bolt type) fixing clips of sheet cast or extruded section & fixing bolts , sliding bolts of extruded section complete all as specified & directed
S&F factory made Box type steel window, double shutter, glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including provision and welding of guard bars complete all as specified and directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 with one amendment dated 22 Jun 07 in Sh 1/3 and dt 15 Jun 07 in sh 2/3 & 3/3 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. (ii) Glazing & Wire cloth shall be measured and paid separately . (iii) MS guard bars shall be measured and paid separately. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
S&F in replacement powder coated aluminium anodised window/ventilators shutters with chowkhat made out hollow aluminium section suitable for aluminium shutter and aluminium guard bars each shutter having two numbers aluminium hinges 100mm long , aluminium handle of 100mm size , 150mm long two Nos aluminium tower bolts and glazing with 5.00mm thick glass fixed with glazing clips, rubber beading and aluminium beading etc complete all as specified and as directed. CHOWKHATS SIZE : 100 X 44 X 1.60 MM THICK SHUTTERS MEMBER SIZE : 100 X 44 X 1.60 MM THICK
S&F in replacement anodised aluminium door made out hollow aluminium section as mentioned below. Each door having 02 Nos disc or D type handle of 200 mm long , two Nos aluminium tower bolts of 200mm size, one No mortice lock of six levers with key in duplicate regulated by double action hudrolic floor door spring shutters to be partly glazed with 5mm thick tinted glass and partly panelled with 12mm thick prelaminated particle board fixed with glazing clips, rubber beading/gasket anodised aluminium beading screws etc complete all as specified and as directed. CHOWKHATS SIZE : 100 X 44 X 1.60 MM THICK SHUTTERS VERTICLE STYLE : 100 X 44 X 1.60MM SHUTTERS LOCK RAIL : 150 X 44 X 1.60MM SHUTTERS BOTTOM RAIL : 200 X 44 X 1.60MM
S&F in replacement anodised aluminium partition wall or fixed type window/ventilator made out of aluminium anodised standard hollow section 100 x 44 x 1.60mm thick snap fit beading standard rubber gasket 5.5mm thick glass or 12mm thick prelaminated particle board interior grade prelaminated one side with decorative choice laminates and other side balancing light grey lamination etc complete all as specified and as directed.
S&F in replacement anodised aluminium grill of approved design/pattern fixed to aluminium frame work complete all as specified and as directed.
S&F double actiopn floor spring hydraulically regulated made up of min 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc complete all as specified and directed. .
S&F any size mortice lock six levers with double keys for aluminium door complete all as specified and directed.
Taking down carefully copper/aluminium point wiring(concealed or surface) of light/fan/bell/socket or power complete fittings such as switches, sockets, ceiling rose, pandent holders, light fittings etc including taking down carefully by unscrewing from board/outlets/DBs/fittings etc such as switches,lamp holdes,brakets,ceiling fittings, bulkhead fittings,sketch fittings, tube light fittings, fan regulators,electric meters, meter bos any type etc and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ceilings complete all as specified and directed .
Material and labour for concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point & call bell point controlled by one way switch 5/6 amp complete all as specified and directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the independent board complete all as specified and directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the same board complete all as specified and directed.
Material and labour for concealed point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with stranded copper conductor, 1100 volt, in and including non metallic rigid PVC concealed conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one switch on the independent board complete all as specified and directed. Note for srl No 121.00 to 124.00 :- (i) Switch, socket outlet, switch socket combination, bell push and fan regulator shall be measured and paid for separately. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match with the existing surfaces.
Material and labour for surface point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including stove enameled steel conduit not less than 19/20mm bore, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3 mm thick including Flame retardant low smoke(FRLS), PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point & call bell point controlled by one way switch 5/6 amp complete all as specified and directed.
Material and labour for surface point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including stove enameled steel conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the independent board complete all as specified and directed.
Material and labour for surface point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, 1100 volt, in and including stove enameled steel conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 5/6 amp controlled by one switch on the same board complete all as specified and directed.
Material and labour for surface point wiring with (FRLS) Flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with stranded copper conductor, 1100 volt, in and including stove enameled steel conduit not less than 19/20mm dia, medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylem) including (FRLS) Flame retardant low smoke PVC insulated multistranded copper earth conductor 1.50 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one switch on the independent board complete all as specified and directed. Note for srl No 125.00 to 128.00 :- (i) Switch, socket outlet, switch socket combination, bell push and fan regulator shall be measured and paid for separately.
S&F switch piano, flush type, 6 amp, single pole, one way, 240 volt complete all as specified and directed.
S&F switch piano, flush type, 15 amp, single pole, one way, 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 5/6 amp, 240 volt, complete all as specified and directed.
S&F socket outlet, flush type, 5 pin, 15 amp, 240 volt, complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite, 65X50 mm three terminals ,230 volts,ISI mark complete all as specified and directed.
Supply & fixing lamp holder PVC/Polycarbonate insulated body with back plate suitable for angle/batten fitting complete all as specified and directed.
S&F stepped type electronic fan regulator flush type, single pole 240 volts, 50 Hz, 100 watts, on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
Supply and fixing in replacement LED tube light fitting 1x18 watt fitting four feet length, 230 volts in commmercial channel with powder coated CRCA sheet housing with opal acrylic diffuser for LED with & including LED tubelight with high efficient LED 18/20 watts in aluminium housing with clear & milky diffuser including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have PF 0.9,CRI>70,L70.
Supply and fixing in replacement indoor decorative LED batten with opal diffuser with inbuilt LED tube 10 watts and driver designed with high transmitting optics for even light distribution IP20 degree protection having length 620mm including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed. Note:- LED fitting should have PF 0.9,CRI>70,L70.
Supply and fixing in replacement Bulk head LED fitting 10 watts fixed to wall/ceiling with FI clamps, nuts, bolts, washers etc with and including LED lamp 10 watts and connecting with twin core twisted flexible copper conductor cable of suitable size not more than One mtr and making necessary connection to make it functional complete all as specified and directed.
Supply and fixing in replacement recessed/surface mounting LED flat panel 2 feet x 2 feet with high efficient LED with and including glare free full window opal diffusal 36 watts with and including LED lamp including connecting with twin core twisted flexible copper conductor cable of suitable size and making necessary connection to make it functional complete all as specified and as directed.
Supply and fixing 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, with and including GI bracket made out of 40 mm bore pipe light grade of length not less than 1.5 mtr with one bend, including taking down existing light fittings complete all as directed and specified.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 4 sqmm cable alongwith one run of 2.5 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 6 sqmm cable alongwith one run of 4 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through with and including stove enameled steel conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 4 sqmm cable alongwith one run of 2.5 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through with and including stove enameled steel conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 6 sqmm cable alongwith one run of 4 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 10 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through with and including stove enameled steel conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 10 sqmm cable alongwith one run of 6 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
Supply and fixing in replacement sheet metal enclosure for MCB DBs, 415 volt, triple pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs, 230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs ,230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link, 8 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for MCB DBs ,230 volt, single pole and neutral, distrubution board, IP 43 protection, with 200 Amps rated copper bus bar and neutral link,12 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing in replacement MCB, SPN, 5 to 40 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
Supply and fixing in replacement MCB, SP, 5 to 32 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
Supply and fixing in replacement MCB, TPN, 63 Amp, B curve, 10 kA capacity, 240 volts complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosures powder coated deep drawn DB with clad socket & plug top duly installed netral link adjustable din rail and connecting link with and including one triple pole neutral MCB 63 Amp, 'B' curve 240 volts, 10 kA complete all as specified and directed.
Supply and fixing ceiling fan, copper winded complete with accessories, 1200 sweep, minimum 5 star rated and including hanging, connecting with existing point complete all as specified & directed.
Material and labour in replacement earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth wire 4.0 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 15 mm bore, light grade including protection pipe GI light grade 20mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion on site complete all as specified and as directed. Notes:- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the earth resistance (less than 3 ohm) is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Supply Installation Testing and Commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x25x3mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriters underwriters laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter - an international standard for Earth Enhancement Compound by NABL accredit Lab complete all as specified and as directed. Note : (i) The rate for interconnection of tripod earth with Copper strip of size 20x3 mm and poly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. (ii) The Earth result should be less than 1 ohm for 3 year will be the responsibility of the contractor and no extra cost paymnet will be paid for this and the result will be checked in presence MES Rep. (iii) The earthing shall comply to IS 3043, UL 467, BS/EN 50164-7. (iv)To obtain less than one ohm if a combination two or more earthings are to be interconnected or the length of the electrode is to be increased it shall be measured and paid as one earthing only. (v) Testing of the earth shall be carried out in presence of departmental rep and a report shall be submitted the cost of the same is deemed to be included in the quoted rates.
Supply and fixing wall mounted fan, AC, single phase 230/240 volts of size 450 mm Sweep including suitable size of fashtner complete all as specified and directed
Supply & fixing heavy duty exhaust fan, single phase, 230/240 volt, 300mm sweep, steel body, turbo force, 1400 RPM, totally enclosed heavy duty motor with copper winding including mounting brackets for fixing with & including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan , making good the disturbed portion in cement mortar 1:3 to match with the existing surface and making connetions with twisted copper flexible wire 23/0.0076mm to make it functional complete all as specified and directed.
Supply and fixing in replacement GI strip 32 x 6 mm on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosures powder coated deep drawn DB with clad socket & plug top duly installed netral link adjustable din rail and connecting link with and including one single pole MCB 20 Amp, 'B' curve 240 volts, 10 kA complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed with and including 3 nos, 8mm dia, 25mm long hexagonal head screw complete all as specified and directed.
Supply & fixed copper strip of size 20x3 mm complete with saddles and base insulators (made out of porcelene/PVC) and fixing screws on roof and down side conductors complete all as specified and directed.
M&L in replacement sub main wiring with two single core FRLS, PVC insulated cable,1100 volts grade, 1.5 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated 1 sqmm stranded copper conductor earth continuity cable drawn through with and including stove enameled steel conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match of wall/ceiling by plastering & applying two coats of distempering complete all as specified and directed. Note :- Two runs of 1.5 sqmm cable alongwith one run of 1 sqmm cable as earth wire alongwith conduit shall be measured as one unit.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 Sqm on plan or for laying pipes/cables etc and getting out, in any type soil complete all as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in any type soil complete all as specified and as directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.
Supply and laying old size, sub class 'B' bricks, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 25 sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement LT XLPE electric cable, 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 16 sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches or along the wall/pole through pipe etc, complete all as specified and directed. Note for Srl item No 169.00 to 170.00:- Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately.
Supply and fixing in replacement 1100 volts grade heavy duty cable insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed as in service connection suspended by insulated hangers not more than 1 mtr apart including 4 mm suspension wire one twin core 10 sqmm stranded conductor complete all as specified and directed
M & L in replacement house bracket ( hook type) complete with 3.0 m long GI pipe 40 mm dia med grade , two No 90 degree MS hook and stay or guy complete all as specified and directed
“ Supply and fixing in replacement LED light fittings 90watts, input 110 volts to 240 volts volts, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 66 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 with and including GI bracket 40 mm dia light grade of length 1.2 meter bend to shape and suitable size of clamps nuts bolts , washer , fashner duly painted complete all as specified and directed
Taking down of existing mild steel shutters including frame, area exceeding 5.50sqm and not exceeding 6.00sqm and refixing the same after repairing, welding of new hold fast, pintle hing, re-allignment of defective/bended angle iron or other section including cutting to required size, refixing of old existing wall clading sheet whereever required and painting with one coat of synthetic enamel paint after preparation of old steel surface, providing PCC 1:2:4 type B1 as in holdfast and making good to match the existing surface complete all as specified and directed. Note: Painting on steel surface as described above and PCC for holdfast are deemed to be included in quoted rates.
For Credit schedule refer tender documents.
ANIL CONSTRUCTION CO.
Gupta Enterprises
M/s B.S.Jain
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .