Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹67.4 L Quoted ₹69.0 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹73.5 LRejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹73.5 L | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹83.6 LRejected-Finance | ₹83.6 L | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | B5BUILDING SOLUTIONS L3 | Shree Ayyappa Engineering L1 | Roy and Sons Infrastructures L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing entire LT panel alongwith switchgears ACB's, MCCB's, meters CT's, busbar including disconnection of LT UG cable and taking out panel from station and it will be considered as Schedule of Credit complete all as specified and directed. | 1 | EACH JOB | 60,000 ₹60,000 | 15,000 ₹15,000 | 30,000 ₹30,000 |
| 2.00 | Supply, installing, testing & commissioning, factory made and tested, LT panel board, indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 4800 Amps (3 Ph x 4800 Amps + 01 No x 4800 Amps) rating duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non-hygroscopic, non-combustible, track resistant high strength FRP insulators for phases and neutral set of 4 for RYB&N. The panel shall be dust and vermin proof, IP 56 class protection and made of 2mm CRCA sheet duly treated through 8 tank pre-treatment process and painted with epoxy powder coated matt finish of SIEMENS GREY | 1 | EACH JOB | 78,65,000 ₹78.7 L | 66,50,000 ₹66.5 L | 70,50,000 ₹70.5 L |
| 2.01structural RAL 7032 shade colour, built in industrial type locking arrangements on front and back and PVC sleeved aluminium strip for connecting ACBs/MCCBs, fixing of LT panel at the same location i.e. old panel location, panel builder shall have the CPRI sample test certificate and 50 x 50 x 6mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, with aprons for cable entry and fixing 02 Nos danger notice plate of size 20cm x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc., with voltage and | ||||||
| 2.02danger indicated in Hindi & English with double door shutter and locking arrangement internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 4 Sqmm. The platform shall be as per site requirement including connections of all outgoing / incoming existing cables of size 25 to 400 sqmm by drawing / digging out cable from loops in trenches / ducts outside the building inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size aluminium lugs for terminal connections of cables, necessary PCC foundation / | ||||||
| 2.03brick with plastering to the cable duct / wall damaging area, all outgoing feeders various feeders shall be indicated by 50mm size letters in synthetic enamel white paint and bus coupler connected as per 4800 Amps bus bar same size with interlinking connection including supply, laying end joint kit / jointing, testing & commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 size of cable 300 sqmm 31/2 core as per site required quantity for new connection ACB to ACB inter connection with complete all as specified and as directed by Engineer-in-Charge. | ||||||
| 2.04The scope of work includes the following items: Note: LT panel board should be as per IS/ICE 61439 - Part I & II type test certificates for minimum 4800 Amps with breaking capacity not less then 65 KA. Panel builder should submit all certificates before executing the job. 1. Incoming: - (i) Air Circuit Breaker 3200 Amps, 4 pole, 4 pole, 100% Icu, the Air Circuit Breaker shall 4 pole, 415 volt, 3 phase, 50 Hz AC front operated with microprocessor-based LCD protection release for adjustable over current, short circuit and earth fault protection with ZSI. The breaker shall be with fully rated neutral & have minimum breaking capacity of 50KA (RMS) symmetrical. | ||||||
| 2.05Designed operational voltage should be 690 V. The ACB should have Ics = Icu = Icw for 1 sec. for short circuit breaking capacity and pre-overload, overload & over-temperature protection feature with 4 NO/4 NC auxiliary contacts. | ||||||
| 2.06ACB shall also confirm to IEC 60947 / IS-13947 / Part-II / 19939 latest version). Protection release should have display with inbuilt battery back-up. Breaker should have last 20 tripping detail memory complete - 02 Nos. (ii) Ammeter Digital type, CT operated 0-3200A range - 02 sets (with selector switch and CT). (iii) Volt Meter Digital type 0-500 V range - 02 Nos (with selector switch). (iv) Indicating lamp LED type 240 V 50 HZ AC supply set of three colour (RYB) - 02 sets. | ||||||
| 2.07(v) Indication lamp LED type 240 V 50 HZ AC supply one set of two colour (Red and Green for ON/OFF indication of ACB) - 02 sets. 2. Outgoing: - (i) Air Circuit Breaker 1600 Amps, 4 pole, 100% Icu, the Air Circuit Breaker shall 4 pole, 415 volt, 3 phase, 50 Hz AC front operated with microprocessor-based LCD protection release for adjustable over current, short circuit and earth fault protection with ZSI. The breaker shall be with fully rated neutral & have minimum breaking capacity of 50KA (RMS) symmetrical. Designed operational voltage should be 690 V. | ||||||
| 2.08The ACB should have Ics = Icu = Icw for 1 sec. for short circuit breaking capacity and pre overload, overload & over-temperature protection feature with 4 NO / 4 NC auxiliary contacts. ACB shall also confirm to IEC 60947/IS-13947 / Part-II / 19939 latest version). Protection release should have display with inbuilt battery back-up. Breaker should have last 20 tripping detail memory complete - 04 Nos. | ||||||
Updated dates
Tender Value
₹67 L
EMD Value
₹1.3 L
Closing Date
4 Mar 2026, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
ADDITION ALTERATION AND SPECIAL REPAIRS TO MAIN AIR CIRCUIT BREAKERS ACB PANEL OF SUBSTATION No. 1 AT NPOL, KOCHI
2026_MES_747540_1
86146
Open Tender
Electrical and Maintenance Works
120 days
KOCHI
Class C
category b(i)
7 documents required · 7 mandatory
₹1,000
ASST GARRISON ENGINEER I RND KOCHI
₹1.3 L
Yes
30 Mar 2026
7 Jan 2026
6 Mar 2026
7 Jan 2026
4 Mar 2026
18 Feb 2026
EACH JOB
EACH JOB
RUNNING METRE
SQUARE METRE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_837122.xls
BOQ • 0.48 MB
86146Tender.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid