Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC NOT SPECIFIED | ₹2.0 Cr | L1 | Accepted-AOC L.-01 |
| 2 | L2₹2.0 CrRejected-Finance VILL BUDHIPAT PO PS BHARNO DIST GUMLA | GUMLA | JHARKHAND | ₹2.0 Cr | L2 | Rejected-Finance L.-01 |
| 3 | Rejected-Technical 81 GURUDWARA ROAD NEAR GURUDWARA KAROL BAGH NEW DELHI DELHI | NEW DELHI | DELHI | 110001 | - | - | Rejected-Technical attached. |
| 4 | Rejected-Technical JHARKHAND | LOHARDAGA | JHARKHAND | 835302 | - | - | Rejected-Technical attached. |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
27 Dec 2025, 5:00 pmClosed
E.E. M.I.DIV. GUMLA.
E.E. M.I.DIV. GUMLA.
Civil work For Comprehensive Renovation work in ST Residential Girls Middle School,Chaurapath,Block-Bushunpur,Dist.-Gumla.
2025_WRD_108074_1
MID/GUMLA/F2-28/25-26
Open Tender
Civil Works
335 days
GUMLA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹3.9 L
10 Apr 2026
22 Dec 2025
29 Dec 2025
22 Dec 2025
27 Dec 2025
22 Dec 2025
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. (BCD-5.1.1)
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) (BCD-5.1.2)
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) (BCD-5.1.7)
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) (BCD-5.1.10)
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (BCD-5.2.6)
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.2.14)
Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. (BCD-5.2.23)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (BCD-5.3.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) (BCD-5.3.1.4)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (BCD-5.3.1.6)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (BCD-5.3.8)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (BCD-5.3.9.1)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (BCD-5.3.10)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (BCD-5.3.11)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (BCD-5.3.17.1)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (BCD-5.3.17.3)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (BCD-5.3.17.5)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts (BCD-5.3.17.6)
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases (BCD-5.3.17.7)
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. (BCD-5.4.32)
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. (BCD-5.4.38)
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) (BCD-5.5.4)
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} (BCD-5.5.5a)
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (BCD-5.5.5b)
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(c) 16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (BCD-5.5.5c)
providing Tor steel reinforcement of 20mm,25mm, 28mm & 32mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 20/25mm TMT bar Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (BCD-5.5.6)
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (BCD-5.5.12)
Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (BCD-5.5.13)
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. (BCD-5.5.14)
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. (BCD-5.5.14)
Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (BCD-5.5.29)
Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (BCD-5.5.30)
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.6.10)
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.6.20)
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With "A" grade white 15X15cm Tiles. (BCD-5.6.23.1)
For Stair Providing and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300 mmx15 mm (BCD-5.6.26)
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . (BCD-5.6.28)
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.7.1)
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.7.3)
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD-5.7.6)
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. (BCD-5.7.11)
Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I. (BCD-5.7.21)
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. (BCD-5.8.18)
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. (BCD-5.8.21)
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) (BCD-5.8.41)
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (BCD-5.8.45)
Providing single layer Naria- tiles in roof including cost of all labour and materials, taxes, all coplete as per building specification and direction of E/I. (BCD-5.9.6)
"Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand -
1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After
three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°C Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)
(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured." (e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years. (BCD-5.12.1)
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering, and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.- There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+ (BCD-5.12.2)
Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm (DSR-8.2.2.1)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (DSR-10.14)Fixing with adjustable lugs with split end tail to each jamb (DSR-10.14.1.1)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: (DSR-10.14) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR-10.14.3.2)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required)and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc.,of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) (DSR-10.28)
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc.,complete. (DSR-11.4)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.41.1)75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.41.2)110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.42.1.1) 75 mm Coupler
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.42.1.2)110 mm Coupler
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.42.3.2)110x110x110 mm Single tee with door
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.42.5.2)110 mm bend Bend 87.5°
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR-12.42.6.2) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (DSR-12.43.2)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (DSR-13.26)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (DSR-13.45.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR-13.8)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes (DSR-18.7.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes (DSR-18.7.4)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes (DSR-18.7.5)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes (DSR18.8.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes (DSR-18.8.2)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes (DSR-18.8.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes (DSR-18.8.4)
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia. (DSR-18.58.1.1)
Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia with 25 mm waste hole (DSR-18.58.1.2)
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg (DSR-19.18.2)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey combshaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as perstandard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR-21.1.1.1)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivotsand making provision for fixing of fittings wherever required including the cost of EPDMrubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR-21.1.2.1)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR-21.3.1)
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia (DSR-23.3.3)
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineerin-charge.100 mm nominal size dia (DSR-23.4.1)
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. (DSR-23.5)
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR-23.6)
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR-23.12)
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia. (DSR-23.13.3)
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp. (DSR-23.14.3)
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I (A) Cement
(B) Sand
(C ) Chips
(D) Brick
Earthwork in excavation(As per I.S. 3114/1965 for laying of different types and sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. (DWSD-3.1.1.1)
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification for soil item-A& B (DWSD-3.1.1.2)
Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I. (DWSD-3.1.5.1)
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. 15 mm dia. (DWSD-3.1.6)
Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. 32 mm and weight not less than 700 gms. (DWSD-3.1.12d)
Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. 40 mm and weight not less than 1.0 kg. (DWSD-3.1.12e)
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.600mm x 450mm size (DWSD-3.1.21)
Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. with 10. lit. low level PVC cistern. (DWSD-3.2.1)
Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. 10 lt. low level PVC Cistern (DWSD-3.2.2)
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. (DWSD-3.2.5)
Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.(i)125mm thick wall (DWSD-3.2.11(i))
Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.(ii)250mm thick wall (DWSD-3.2.11(ii))
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. (DWSD-3.3.1 (i))
Labour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.(a) 150 mm dia pipe (DWSD-3.3.6.2)
Supplying labours, tools and tackles for testing of laid, R.C.C. spun pipes upto specified lead water all complete as per specification and direction of E/I. (water to be supplied free of cost departmentally). 225mm dia (DWSD-3.3.7 (iii))
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I. (DWSD-3.3.8)
Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required. Group B (DWSD-1.3.2)
Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required. Group C (DWSD-1.3.3)
Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried. (ENERGY-1.4)
Circuit /sub main wiring in PVC conduit :- Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. 2x1.5 sq mm + 1x1.5 sq mm earth wire (ENERGY-1.7.1)
Circuit /sub main wiring in PVC conduit :- Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (ENERGY-1.7.2)
Circuit /sub main wiring in PVC conduit :- Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. 2x4.0 sq.mm + 1x4.5 sq.mm earth wire (ENERGY-1.7.3)
Circuit /sub main wiring in PVC conduit :- Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. 2x10 sq.mm + 1x10 sq.mm earth wire (ENERGY-1.7.5)
S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. 75 mm x 75 mm x 50 mm deep / (4" x 4" ) (ENERGY-1.22.1)
S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. 72 mm x 146 mm x 48 mm deep / (4" x 7" ) (ENERGY-1.22.2)
S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. 210 mm x 206 mm x 48 mm deep / (10" x 12" ) (ENERGY-1.22.9)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps one way switch (ENERGY-1.24.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp 3 pin socket outlet (ENERGY-1.24.4)
S/F Modular type Electronic Fan Regulator- Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. (ENERGY-1.25)
S/F Modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried. (ENERGY-1.26)
S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried. (ENERGY-1.32)
S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. S/F celling rose :- (ENERGY-1.33)
S/F Batten holder :- Supplying and fixing battrn / angle holder including connection etc as requried. (ENERGY-1.34)
ITC fluorescent fitting directly on surface :- Intallation testing and commissioning of pre wired fluorescent TUBE fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried. (ENERGY-1.41)
ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried. (ENERGY-1.44)
ITC. Exhaust fan upto 450 mm sweep. Installation of exhaust fan upto 450 mm sweep in the existing opening , including making the hole to suit size of the size of the above fan , making good the damage , connection , testing , commissioning etc. as required. (ENERGY-1.48)
S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. 16 amps, double pole (ENERGY-2.1.1)
S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. 32 amps, double pole (ENERGY-2.1.2)
S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. 63 amps, double pole (ENERGY-2.1.3)
S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. 32 amps, TP&N (ENERGY-2.1.4)
S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. 200 amps, TP&N, HRC (ENERGY-2.2.3)
S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. 400 amps, TP&N, HRC (ENERGY-2.2.5)
S/F Busbar chamber :- Providing and fixing following capacity busbar chamber with 4 strips of sutiable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as requried. 400 amps (ENERGY-2.5.4)
S/F Panel montude change over:- Providing and fixing following capacity 4 pole panel mounted change over switches in existing cubcile panel board, making connection earthing the body etc as requried. 400 amps, 4 pole (ENERGY-2.7.9)
S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 4way,Single door (ENERGY-2.8.2)
S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 6way,single door (ENERGY-2.8.3)
S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 8 way , single door (ENERGY-2.8.4)
S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 4way, Double door (ENERGY-2.8.7)
S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 16way,Double door (ENERGY-2.8.10)
S/F S.P. MCB DB :- Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphatize and powder painted inculiding earthing etc.as required.(But without MCB/RCCB/Isolator)4way (4+12), Single door,Horizontal type (ENERGY-2.9.4)
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 6/32 amps, Single pole (ENERGY-2.12.1)
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 40 amps, DP (ENERGY-2.12.6)
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 4 pole MCB 40 A,16 kA with fixed thermal magnetic (ENERGY-2.12.9)
S/F SP MCB blanking plate :- Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required .(ENERGY-2.13)
Copper earth plate electrode:- Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt). (ENERGY-3.6)
S/L 8 SWG copper wire in ground:- Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried. (ENERGY-3.9)
S/L 25mm x6mm G.I. earth strip in ground :- Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried. (ENERGY-3.12)
P/F G.I lighting conductor finial :- Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried. (ENERGY-4.2)
Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried. (ENERGY-4.4)
P/F G.I lighting conductor tape in vertical run :- Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ). (ENERGY-4.8)
P/F Testing joint for G.I lighting conductor :- Providing and fixing testing joint, 20 mm x 3 mm thick copper strip 125 mm long , with 4 nos. of G.I bolts, nuts, check nuts and spring washers etc. complete as requried. (ENERGY-4.12)
P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried. (ENERGY-4.14)
MV Cable Laying up to 25 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm. direct in ground including excavation, sand cushioning, protective covering by 2nd class bricks and refilling the trench etc as required. (ENERGY-5.1)
MV Cable Laying upto 95 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. (ENERGY-5.2)
Maximum 12W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP40, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 1320 lm with Minimum 110 lm/W system efficacy. Cutout Dia-ø110mm. Similar to Wipro Make LD06-151-XXX-40-XX or Equivalent Philips make. (ENERGY-9.3.2)
18W, High efficient surface mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 1800 lm with Minimum 100 lm/W system efficacy. Cutout Dia-ø145mm. Similar to Wipro Make LD06-221XXX-40SMG1 or Equivalent Philips make. (ENERGY-9.3.4)
9W, High efficient recess mounted COB LED downlighter with extruded aluminium housing. High efficiency 38 Deg beam reflector optics for effictive thernmal management using aluminium casting. CRI>80, CCT - 4000K,50,000 hrs @ L70 life. IP20, Ambient temp- 0 to 45 DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Cutout Dia-ø90mm. Luminaire lumen ≥ 900 lm. (100 lm/W). Similar to Wipro Make LD98-131-038-40-XXor Equivalent Philips make. (ENERGY-9.3.14)
32W, High efficient track mounted COB round LED downlighter with extruded aluminium housing. High efficiency 36 Deg Beam reflector optics for effictive thernmal management using aluminium casting. CRI>80, CCT - 5700K, 50,000 hrs @ L70 life. IP20, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 3070 lm. (95 lm/W). Similar to Wipro Make LD57-381-036-40-XX or Equivalent Philips make. (ENERGY-9.3.17)
Supply of Ceiling BLDC Fan: Supplying, installation, testing and commissioning of 1200 mm (48")Sweep BLDC 5 star, 32W AC ceiling fan confirming to IS: 374: 2019 , including connection with 1.5 sq mm copper wire, down rod of standared length(upto 30cm) withall accessories as required. Make :- Polar/Bajaj/Crompton / Havells / GEC. 1200MM (48")Ceiling Fan (ENERGY-9.4.1)
Supplying, installation, testing and commissioning of floowing rating surface mountaed LED tube light fitting suitable foe 230v 50Hz single Phase supply etc. complete required.10/12 . Watt LED Tube LIGHT (ENERGY-9.5.1)
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, (SINTEX / SINTER) ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. (DWSD-M-079,PG-31)
Supplying laying fitting and fixing NP2 R.C.C spun pipes all complete as per direction of E/I. (BCD-M-300/P-86)
70 sq. mm, 3.5 core (ENERGY-M-329/P-45)
35 sq. mm, 3.5 core (ENERGY-M-327/P-45)
9" (230mm) metal exaust fan (ENERGY-M-774/P-52)
Supply of Metal Exhaust Fan 12"(300mm): Supply of 12"(300mm), 230V AC metal exhaust fan in the existing opening. (ENERGY-M-775/P-52)
4c x 10 sq mm (ENERGY-M-739/P-75)
15/16 Watt LED BULB (ENERGY-M-856/P-170)
S/F/ special type Bulk Head fitting with 100W bulb etc. as required (COMMON PART-A,M-869/P-131)
Bulk head fitting with 9/10 Watt CFL/LED (ENERGY-M-869/P-57)
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe all complete job as per direction of E/I. (ENERGY-M-930/P-32(K))
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (ii) piller Cock (Long Neck)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (iv) Bib cock (Long Thread)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (vi) Angular Stop Cock (Long Thread)
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (xvii) 4 way diverter for concealed fittings
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (xxi) Towel Rail 24"
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (xxiv) Tumbler holder
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (M-961/P-40) (xxvi) Glass shelf 22'
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (DWSD-M-1035/P-57 TO 58) (a) From 0.00 M to 50.00 M below G.L.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING (DWSD-M-1035/P-57 TO 58) (b) From 51.0 M to150.00 M
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP (DWSD-M-1055/P-66 TO 67)
Stainless steel kitchen sink with drain board 510x1040mm bowl depth 200mm (COMMON PART A M-1255/P-70)
After adding GST @18% on total estimated value the total estimated amount is
Labour Cess @1% on above total estimated amount
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_145966.pdf
BOQ Comparative Chart
xlsx
finsummary_145966.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
DOC2.pdf
Tender Documents • 1.16 MB
BOQ_145966.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid