Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹17.9 L+₹1.2 L (7.18%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹17.9 L+₹1.2 L (7.21%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹18.0 L+₹1.3 L (7.91%)Rejected-Finance | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹18.6 L+₹1.9 L (11.6%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
REPAIRS TO SUMMER APPLIANCES SUCH AS CEILING FANS,EXHAUST FANS, AIR CONDITIONER , WATER COOLER , REFRIGERATOR, SOLAR WATER HEATER, GEYSERS AND CONNECTED ITEMS UNDER GE(A) JAMNAGAR.
2022_MES_524136_3
8898
Open Tender
Civil Works
Item Wise
334 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹30,000
8 Aug 2022
2 Jun 2022
24 Jun 2022
3 Jun 2022
22 Jun 2022
16 Jun 2022
Amount
Taking down ceiling fan any type from hook and sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging ceiling fan in position after repair greasing etc. and connecting up including provision of cable from ceiling rose of connecter to fan flexible copper cable of size 23/00076 complete directed at site (Note: re-winding of fan and parts required shall be measured and paid separately under relevant item of sch 'A')
M & L for re-winding of ceiling fan 1200 mm sweep with super enamelled copper wire as per existing size/gauge
M & L for re-winding of ceiling fan 1400 mm sweep with super enamelled copper wire as per existing size/gauge
Taking down Exhaust/pedestal/wall mounted fan any type sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging exhaust fan in position after repair greasing etc. and connecting up including provision of cable from ceiling rose of connecter to fan flexible copper cable of size23/00076 canopy complete directed at site (rewinding of fan painting and parts required shall be measured and paid separately)
M & L for re-winding of Exhaust fan of 230/300/325mm sweep complete all as specified and directed by Engineer-in-Charge.
M & L for re-winding of exhaust fan 300mm to 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix condenser 2.5 Mfd including dismantling of unserviceable condenser, reconnection and testing complete all as specified and directed by Engineer-in-Charge. Make: Havells / Tibcon / Seimens
Supply and fix including removing of unserviceable condenser and replacement with new condenser 4 Mfd (+) or (-) 10% of approved make including connecting soldering complete all as specified and directed by Engineer-in-Charge. Make: Havells/ Seimens/TIBCON
Supply and fix including dismantling, removing of unserviceable ball bearing (in ceiling fan) and replacement with original size ball bearing of following sizes and approved make to suit the respective make including testing and commissioning complete all as specified and directed by Engineer-in-Charge. : Make: Tata / NBC / SICF
(a) Ball bearing No 6201
(b) Ball bearing No 6202
(c) Ball bearing No 6203
Supply and fix in replacement of old unserviceable gun metal bushes for ceiling fans of same type, size and shape as per existing bushes of approved make complete all as specified and directed by Engineer-in-Charge.
M&L for painting of complete ceiling fans, exhaust fans at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
(a) Ceiling fan of 1200mm sweep.
(b) Ceiling fan of 1400mm sweep.
(c) Exhaust fan of 230/300/325mm sweep.
(d) Exhaust fan of 380/400/450mm sweep.
Supply & fix in replacement of ceiling fan blades (set of three) suitable for any make and size as approved and complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of canopy suitable for ceiling fan of any make and size as approved and complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Ceiling fan Down rods 30/45cm long complete as per existing size complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper Flexible cable twisted 3core 1.00 Sqmm for fan connection complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of clamp Heavy duty for hanging celling fan as per existing size including 2 No of Nuts bolts with lock pin rubber seal complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Electronic fan regulator step type (5 Steps) 2module 100/120w ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc, complete all as specified and directed by Engineer-in-Charge.
WINDOW/ SPLIT TYPE AC
M & L for tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in window type AC capacity 1.5/2 TR complete all as specified and directed by Engineer-in-Charge.
M & L for tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in split type A/C 1.5 /2.0 Ton capacity complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of starting capacitor of 100/120 MFD, 230 Volt AC suitable for 1.5 TR/2.0TR capacity AC complete all as specified and directed by Engineer-in-Charge. Make : Usha/Keltron/ BHEL /KEL/Texla
M & L for removing existing unserviceable compressor cut/uncut from window type/split A/C and replacement of factory reconditioned clean compressor ( with 1 year replacement warranty), in exchange suitable for 1.5/2 ton capacity A/C including fixing in original position, with filling of gas R-22 and pressure testing including welding, brazing replacement of filter/Strainer made of copper capillary tube, complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of running capacitor 50/40 mfd 230 Volt AC suitable for 1.5 Ton capacity AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of capacitor, 6 MFD, 240 Volt AC suitable for condenser motor 1/6 HP 1350 RPM complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of overload protector AC suitable for 1.5 TR/2.0 TR capacity complete all as specified and directed by Engineer-in-Charge. Make : Usha /Shriram/ISI marked.
Supply & fix in replacement of starting relay box type R-22 suitable for 1.5TR/2.0TR capacity A/C complete all as specified and directed by Engineer-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from window/split type AC 1.5/2.0 ton capacity and replacement of condenser motor of capacity 1/6 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper condenser in split type air conditioner outdoor unit complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of electronic circuit complete including controlling unit ie (Remote) all as per existing sample and suitable for 1.5 / 2.0 Ton capacity split type AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Copper pipe 1/4 with u Foam for 1.5/2 ton capacity split AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Copper pipe 5/8 with u Foam for 1/5/2 ton capacity split AC complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper AC suction valve of size 5/16 complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of copper AC suction valve of size 5/8 complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of rubber pipe for waste water of 15mm complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of window/Split type A/C unit 1.5/2.0 ton capacity removing from existing position (Indoor & Outdoor unit both in case of split AC) and washable servicing the same by complete cleaning & washing the dust by suitable blower machine method including supply and replacement of air filter, damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor, by oiling, greasing, supply and replacement of bushes of condenser motor, damaged knobs, setting of grills alignment complete including refixing in original position including provision of thermocoal for air tightness, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
REFRIGERATORS
M & L for tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capillary tube, nut bolts of compressor of refrigerators of different capacities etc, complete all as specified and directed by Engineer-in-Charge.
M & L for removing existing unserviceable compressor cut/uncut from Refrigerator capacity 286/310 ltrs and replacement of factory reconditioned compressor ( with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat defrost type for refrigerator.
S&F in replacement condenser in outer side of refrigerator
S&F in replacement of lamp screw/Pin type for refrigerator complete all as specified and directed by Engineer-in-Charge. Make : Phillips/Bajaj
S&F in replacement of cooling coil with PVC freezer door complete with screw/nut bolt suitable for 286/310 litres capacity refrigerator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of over load relay suitable for 280/310 Lars capacity refrigerator as per existing complete all as specified and directed by Engineer-in-Charge.
WATER COOLER
M & L for tracing out the leakage from suction/discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-22, replacement of strainer, capillary tube, nut bolts of compressor of water cooler 40/80 litres capacity complete all as specified and directed by Engineer-in-Charge.
M&L for removing of existing unserviceable compressor cut/uncut from water cooler 120/150 litres capacity and replacement of factory reconditioned clean compressor ( with 1 year replacement warranty) suitable for existing water cooler 120/150 litres capacity including fixing in original position with filling R-22 gas charging and pressure testing ,brazing replacement of strainer, capillary tube cleaning of condenser coil etc complete all as specified and directed by Engineer-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from water cooler 120 to 320 litre capacity and replacement of condenser motor of capacity 1/30 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting relay box type for 120/150 litres capacity Water Cooler including overload protector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat including knob, plate and screw suitable for 120/150 litres capacity storage type water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of push cock, lifting cock 15mm size as per existing pattern for water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC drain pipe approx. 1.5 mtrs long of 25mm dia for water cooler complete with clamp screws etc complete for drain out water from water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Float valve, chromium plated with polythene PVC ball for 15mm (1/2") bore size suitable for 40/80 litres capacity water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of chromium plated drain pot suitable for collecting drain water from 120/150 litres water cooler, as per existing pattern complete all as specified and directed by Engineer-in-Charge.
S&F in replacement condenser suitable for 120/150 Ltrs capacity water cooler as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 10 MFD, 440 Volt AC. complete all as specified and directed by Engineer-in-Charge.
DEEP FREEZER
M & L for tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capillary tube, nut bolts of compressor of deepfreezer of different capacities etc, complete all as specified and directed by Engr-in-Charge.
M & L for removing existing unserviceable compressor cut/uncut from Deep freezer of capacity 320 ltrs and replacement of factory reconditioned compressor (with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete all as specified and directed by Engr-in-Charge.
M & L for removing of existing unserviceable burnt condenser motor from deep freezer of 320 ltr capacity and replacement of condenser motor of capacity 1/30 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermostat suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement condenser suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of over load relay suitable for 320 Ltrs capacity deep freezer as per existing complete all as specified and directed by Engr-in-Charge.
M & L for servicing of solar water heater upto 300 ltrs capacity including checking serviceability of individual components and replacement of worn out fasteners, gaskets, washers accessories, inspection of the entire system, cleaning of sacrificial anode, rectification of any leaks, tightening of electric loose connections etc. and making system operational complete all as specified and directed by Engineer-in-Charge. Note: (i) Spares will be measured and paid separately under relevant item of sch 'A'
Supply and fix in replacement of solar water tube 58x1500mm for the solar water heaters complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of solar water tube 58x1800mm for the solar water heaters complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of silicon washers for hot water tank suitable for EGTS complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LLDPE cap washer at top of the EGTS complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LLDPE washer at bottom of the EGTS complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of hot water storage tank having internal MS tank of 2.5mm thickness, duly epoxy coated, with 50mm PUF of 40Kg density and outer covering of PPGI sheet of 0.5mm TCT and side covers of powder coated aluminium. Inlet and outlet connection nipples of SS 304 capacity 100 Ltr complete all as specified and directed by Engineer-in-Charge.
All as per item No.69 above but capacity 200 Ltr
All as per item No.69 above but capacity 300 Ltr
Supply and fix in replacement of MS stand suitable for 100 LPD solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MS stand suitable for 200 LPD solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MS stand suitable for 300 LPD solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of flat plate collector- 2 m x 1m ISI marked as per MNRE standard complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of hose pipe to connect hot water tank of flat collector complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of heating element ISI marked of size 3 KW, 230 volts required for solar water heater complete all as specified and directed by Engineer-in-Charge.
M & L for disconnecting electrically, mechanically and taking down defective electric water heater of any make and any capacity (15/25/50 Ltr) vertical or horizontal from site/store yard, cleaning of tank after opening of its upper & down assembly, cleaning of assembly pipe to avoid choke up, replacement of defective parts catered under the items s&f in repair here under including servicing of water heater and refixing complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of heating elements ISI marked of size 1.5/2 KW 230 Volts required for Geysers of 15/25/50 Ltrs capacity any make complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of thermostat ISI marked of 20 to 89 degree Celsius suitable for electric geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of combined assembly of heating element and thermostat required for 15/25/50 Ltrs Bajaj new shakti Geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of indicator lamp for Geyser of capacity 25 / 50 ltrs. complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of non return valve ISI marked of size 15mm. complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of existing unserviceable rubber gasket of inner assembly of Geysers of capacity 25 ltrs of any make complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of PVC connection pipe 60cm long with brass nuts, washers heavy duty, treaded, suitable for inlet / outlet side of Geysers complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Sheet metal enclosures with socket plug top with 20 Amps MCB SP enclosure with a two pin and earth plug and socket complete with one single pole MCB of 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of worn out/ leaking inner water tank for 15 litre capacity geyser complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of worn out/ leaking inner water tank for 25 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and fix in replacement of worn out/ leaking inner water tank for 50 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply and fix in replacement of base plate in two parts of existing size all as specified & directed by Engineer-in-charge.
Supply and fix in replacement of old/ rusted and worn out geyser outer cover for 25 litre capacity geyser all as specified & directed by Engineer-in-charge.
Supply & fix in replacement of old/ rusted and worn out geyser outer cover for 50 litre capacity geyser all as specified & directed by Engineer-in-charge.
M&L for painting of complete Geyser 25 / 50 ltrs capacity at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of 2.5 Sq.mm 3 core copper conductor flexible cable heavy duty PVC insulated sheathed cable complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of Anchor bolt 6" length with nut and washers, suitable for fixing of water heater Geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of medium grade 15mm dia GI X nipple suitable for connection of water heater Geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of plug top 3 pin, 15/16 Amps complete all as specified and directed by Engineer-in-Charge. Make: Anchor
Supply & fix in replacement of switch flush type 15/16 Amps, single pole one way including taking down existing defective switch complete all as specified and directed by Engineer-in-Charge. Make: Anchor
Supply & fix in replacement of socket outlet flush type 2 in 1 , 3 pin , 5 and 15 Amps flush type including taking down existing defective socket complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of switch socket outlet combination 5 Amps and 15 Amps multipurpose( 2 in 1, 3 pin, 5 and 15 Amp flush type universal) complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring with two runs of 2.5 Sqmm single core PVC unsheathed and insulated 1100 Volt grade/Multi stranded FRLS copper conductor drawn through PVC conduit/casing capping fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 2.5 Sqmm single core as earth continuity wire including taking down old unserviceable sub main wiring complete all as specified and directed by Engineer-in-Charge. Note :- Two runs of single core PVC insulated unsheathed cables and one run of earth continuity conductor incl conduit will be measured and paid as one unit length only.
Rameshwar Enterprise
M/S Badri Electicals
VINUBHAI P. CHANDRA
SURAJ ENTERPRISE
fakhrie apostrical
jitendra c joisar
M/s.Bhavin Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .