| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.3 L+₹1.5 L (10.2%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹16.6 L+₹1.8 L (12.4%)Rejected-Finance 18 GOBINDPURA STREET NO 10 PO RAYON SILK MILLS PURANI CHUNGI CHHEHTRA AMRITSAR 143001 PB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹17.5 L+₹2.7 L (18.3%)Rejected-Finance H NO 786 ANAND VIHAR COLONY PILIBHIT BYPASS BAREILLY UP PIN 243005 | BAREILLY | UTTAR PRADESH | 243005 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹17.8 L+₹3.0 L (20.2%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹20.2 L
EMD Value
₹40,400
Closing Date
19 Jan 2025, 6:00 pmClosed
GE(AF) BAREILLY
GE(AF) BAREILLY-243002 (UP)
PROVN OF DE-HUMIDIFIERS, WORKS SERVICES FOR REINSTALLATION OF 125 KVA SERVO STABILIZER AND PROVN OF FOUR AIR CONDITIONER AT AF STN BAREILLY UNDER GE (AF) BAREILLY
2024_MES_689684_1
GE(AF)/BLY/T-57/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) BAREILLY
₹40,400
Yes
21 Feb 2025
20 Dec 2024
21 Jan 2025
20 Dec 2024
19 Jan 2025
6 Jan 2025
Amount
Supply, install, testing & commissioning of split type air conditioner of capacity 1.5 TR, wall mounted type, working on single phase, 240 volts, 50 Hz AC, R-32 CFC free refrigerant with cordless remote control unit, inverter type (variable speed), BEE 5 Star rating complete with 100% copper condenser coil including fixing of indoor and outdoor unit with necessary copper pipe connections including cutting, bending, brazing, insulation on pipe, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated multi-stranded copper cable complete all as directed by Engineer-in-Charge. [Make: Blue Star /Voltas/ Carrier] Note: (a) Power cable between indoor and outdoor unit, copper piping (3.0 mtr) with heat/ cold resistant nitrile rubber/ foam type insulation, iron stand powder coated for outdoor unit and drain pipe up to the ground level shall be deemed to be included in quoted rate of this item. (b) It is the responsibility of contractor to fill the blanks/ holes made for copper piping and drain system to install the ACs to match with the existing surface.
S&F for wall mounted voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage satbilized at 230 volt with accuracy +/- 2.5% and speed of correction 8 volts per second of capacity 4 KVA complete all as specified and directed. Make:Microtek/Bluebird/V Guard.
S&F for Single Pole and Neutral enclosures with two pin and earth plug & socket 240 volt complete with one number Single Pole MCB 20 Amp complete all as specified and directed.
S&F for MCB Single Pole & Neutral, 240 Volts, 63 Amps 50Hz, 25 KA all as specified.
S&F for MCB Single Pole 240 volts, 5 to 32 Amps, 50HZ, 10 KA, ‘C’ series all as specified.
S&F for sheet metal enclosures MCB distribution board, Single pole and Neutral 220 Volts, 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting chases in wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 4 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed stranded copper conductor FRLS cable of size 4 Sqmm 100 Volts grade as earth continuity conductor drawn through in and including rigid non metallec PVC casing caping on roof/ wall/ ceiling including making good the disturbed surfaces of wall etc complete all as directed. (Note :- Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
Supply , laying & testing XLPE insulated , armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 2 core complete all as specified and directed.
M&L for dry sand cushioning to underground cables with 8 cm thick before laying of cable and 15 cm thick after laying and stretching of cable complete all as specified. (Note : Only punned thickness i.e. 18 cm shall be measured and paid).
M&L for sub class 'B' brick for covering to under ground cable laid dry flat transversally width equal to the length of the cable all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in any type of soil for laying of cables, foundation of poles, stay assembly or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan complete all as specified and directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick all as specified and directed .
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge .
Supply, installation, commissioning and testing of dehumidifier unit, main body made of metallic sheet duly powder coated, comprising built -in compressor of suitable capacity, special purpose fan motor high saving efficient system of minimum capacity of 140 liters per day, dehumidifying capacity of minimum 5.85 Kg per hour, minimum air flow of 1500 Cum per hour, minimum humidity setting of RH-30% to 95% in working temperature of 5 degree centigrade to 45 degree centigrade, electric operated 220-240 volts 50 Hz having minimum power consumption of 2000 watt rotary compressor based type with maximum controlling of noise level of 52 dB using CFC free refrigerant R-407 C or R-410A, drain pipe arrangement towards outside internally fixture to remove the water outside the dehumidifying room, multiple functional wheels, automatic defuser system, delay timer for compressor complete in all respect as required at site and as directed by Engr-in-Charge. MAKE : Model No AMDH1400 of advance international or having same or superior specification in ADVANCE INTERNATIONAL/GMP DUEX INDUSTRIAL SYSTEM/HARRISONS PHARMA MACHINERY PVT LTD/ALISHAPNUEMATICS PVT LTD approved by GE.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 4 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed stranded copper conductor FRLS cable of size 2.5 Sqmm 100 Volts grade as earth continuity conductor drawn through in and including rigid non metallec PVC casing caping on roof/ wall/ ceiling including making good the disturbed surfaces of wall etc complete all as directed. (Note :- Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
M&L for horizontal boring under Road, pavement, hard standing etc complete for inserting GI pipe light grade of size 50/80/100mm bore all as specified. (Note :- GI pipe shall be measured and paid seperately)
M&L for 50 mm bore galvanished iron tube, light grade with all fitting and laid in trenches or inserting in horizontal boring complete all as specified.
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm buried directly in ground (earth pit not less than 2.25 deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to copper earth lead by means of copper earth strip of 25X3 mm , by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre-cast RCC 1:2:4 type B-1 cover slab reinforced with 8mm dia deformed bar 15 cm C/C and suitable handle of 10mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/ loose soil and disposal of soil to a distance n.exec 50 m and necessary testing complete and connected to earth test point including testing complete all as specified and directed. Note: (a) Cost of earthing lead/strip and protection pipe upto 7.5 mtr shall be included in cost of above item. (b) Rate of earth work for earthing shall be deemed to be included in the rate quoted.
M&L for shifting of 125 KVA isolation transformer from exising location to proposed location including taking down of necessary cable connection complete all as specified and directed by Engineer-in-Charge.
Taking out of existing LT under ground cable of size 185 Sqmm to 240 Sqmm 3.5 Core including taking out protection bricks complete all as specified. (Note : Excavation shall be measured and paid seperately under respective item).
Relaying of old serviceable LT XLPE UG cable 1100V grade of size 185 sqmm to 240 sqmm 3.5 core as per site requirement after fault rectification including taking out cables, protection bricks complete all as specified.
Supply, laying and testing LT cable (heavy duty) XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable of size 240 Sqmm 3.5 core in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked complete including commissioning and testing all as specified.
All as per Item No. 22 above but cable of size 185 sqmm 3.5 core.
S&F for cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/4 core, alumminium conductor cable of size 185 Sqmm to 240 Sqmm complete all as specified.
M&L for 100 mm bore galvanished iron tube, light grade with all fitting and laid in trenches or inserting in horizontal boring/floor etc complete all as specified.
Surface excavation in soft/loose soil not exc 30cm deep and averaging 15 cm deep and getting out all as sepcified.
M&L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified.
M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified.
M&L for 100mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base, floor, hard standing etc.
M&L for 150mm thick cement concrete 1:2:4, type B-1 (using 20 mm grade stone aggregate) as in floor finishing top surface even and smooth with using extra cement all as specified.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 all as specified.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces and finished surface even and fair without using extra cement all as specified.
M&L for preparation of newly or untreated surface of wall and applying two coats of white wash all as specified.
Excavating in post holes (or similar holes) each not exc 0.5 cum and getting out in soft/loose soil, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering and removing surplus soil to a distance not exc 50mtr and making good surface all as specified.
M&L for cement concrete type B-2, 1:2:4 (40 mm graded stone aggregate) as in foundations, filling and mass-concrete all as specified.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240 all as specified.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 410-W (Gde E- 250) quality A all as specified.
S&F for pre-painted galvalume aluminum zink coating galvanished iron based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self coaching screw all as specified
M&L for preparation of newly steel surfaces of any description over 10cm in width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified.
M&L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slope of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintel upto1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lasing courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones, bed plates, water troughs and like including weathering, slightly rounded or chamfered angles and throating as directed
M&L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410-W (Gde E- 250) quality-A complete all as specified.
M&L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 290 (Gde E- 165) complete all as specified.
Vishal Traders (BID ID -3218059)
SUN CHEMICALS (BID ID -3208503)
ZAIGHAM ENTERPRISES (BID ID -3212425)
M/s Agarwal Builders (BID ID -3215926)
VINYAK TRADERS (BID ID -3217871)
M/S BABA ENTERPRISES (BID ID -3218621)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .