Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance | L1 | Accepted-Finance Financial Bid | |
| 2 | L2₹1.4 L+₹19,550 (16.5%)Accepted-Finance | L2 | Accepted-Finance Financial Bid | |
| 3 | L3₹2.1 L+₹95,100 (80.3%)Accepted-Finance GMD ROAD MORADABAD MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | L3 | Accepted-Finance Financial Bid | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
28 May 2021, 12:00 pmClosed
E.E., E.T.D.-II, Bareilly
Hydle Colony, Rampur Garden, Bareilly
Repairing, Maintenance overhauling of Split Air Conditioners alongwith other associated works at various 220KV 132KV S.A.S. Sub Stations under ETD-II, Bareilly
2021_UPTCL_586786_1
Short Term E-Tender No / 02 /ETD-II/ (B) /2021-22
Open Tender
Electrical Works
Item Wise
30 days
Bareilly / Pilibhit
Please Refer In Tender Documents
2 documents required · 2 mandatory
₹590
Ac No 0043002100061489 IFSC PUNB0004300
₹2,000
1 Jun 2021
15 May 2021
28 May 2021
15 May 2021
28 May 2021
15 May 2021
Amount
Repairing, Maintenance & Overhauling / Servicing of Split Air Conditioners alongwith other associated Works at 220KV &132KV S.A.S. Sub Station under ETD-II, Bareilly, with all cost of Men, Materials, Misc. Consumables, T&Ps etc, Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per details below:-
Repairing, Maintenance & Overhauling / Servicing of Window/ Split Air Conditioner (Hitachi/Voltas/Daikin/equivalent make) alongwith other associated Works at 220 KV S.A.S. Sub Station Pilibhit under ETD-II, Bareilly as per Details Below :
Replacement of PCB Control Card of Fan in Indoor Unit (1 No. for each A.C.)
Replacement of Fan Blade in outdoor unit.
Refilling & Topping up of R-22 Gas in Split Air Conditioner (1 Job. per A.C.)
Replacement of Running / Starting Condenser.
Repairing of 4KVA Voltage Stabilizer.
Replacement of Blower Fan Motor (model 2KN, 0.75HP, 1400RPM).
Servicing of Spilt Air Conditioner two times (In June, 2021 & Sep, 2021).
Repairing, Maintenance & Overhauling / Servicing of Split Air Conditioner (Hitachi/Voltas/Daikin/equivalent make) alongwith other associated Works 132 KV S.A.S. Sub Station Bisalpur under ETD-II, Bareilly as per Details below:
Replacement of PCB Control Card of Fan in Indoor Unit (1 No. for each A.C.)
Replacement of Fan Blade in outdoor unit.
Refilling & Topping up of R-22 Gas in Split Air Conditioner (1 Job. per A.C.)
Replacement of Running / Starting Condenser.
Repairing of 4KVA Voltage Stabilizer.
Replacement of Blower Fan Motor (model 2KN, 0.75HP, 1400RPM).
Servicing of Spilt Air Conditioner two times. (In June, 2021 & Sep, 2021).
Repairing, Maintenance & Overhauling / Servicing of Split Air Conditioner (Hitachi/Voltas/Daikin/equivalent make) alongwith other associated Works 132KV S.A.S. Sub Station Nawabganj under ETD-II, Bareilly as per Details below:
Replacement of PCB Control Card of Fan in Indoor Unit (1 No. for each A.C.)
Replacement of Fan Blade in outdoor unit.
Refilling & Topping up of R-22 Gas in Split Air Conditioner (1 Job. per A.C.)
Replacement of Running / Starting Condenser.
Repairing of 4KVA Voltage Stabilizer.
Replacement of Blower Fan Motor (model 2KN, 0.75HP, 1400RPM).
Servicing of Spilt Air Conditioner two times. (In June, 2021 & Sep, 2021).
M/s S.S. Refregeration
M/S SATKAR TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .