Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC Accept | |
| 2 | L2₹17.9 L+₹37,721.27 (2.16%)Rejected-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Reject | |
| 3 | L3₹18.0 L+₹49,192.57 (2.81%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L3 | Rejected-AOC Reject | |
| 4 | L4₹18.6 L+₹1.1 L (6.52%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L4 | Rejected-AOC Reject |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Nov 2022, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIRS TO LT CABLE PANELS AND CONNECTED ITEMS AT ZONE B AHMEDABAD
2022_MES_562373_1
8292/E8
Open Tender
Civil Works
Works
180 days
GE (Army) Ahmedabad
As per NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹40,000
Yes
24 Mar 2023
10 Nov 2022
2 Dec 2022
10 Nov 2022
30 Nov 2022
16 Nov 2022
10 Nov 2022 - 16 Nov 2022
Amount
Supply, errect, test and commissioning in replacement Bus bar feeder pillar box of CPRI approved factory fabricated, dust & vermin proof including removable cable entry gland plate, powder coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3mm thick CRCA sheet with incommer and outgoing through Bus bar & hinged door, locking arrangement with aluminium bus bar 400 Amps capacity, LED indicating lamp for RYB grouted, PCC 1:3:6 type C1 for foundation with angle iron legs of size 50 x 50 x 6mm and duly powder coated painted with two coats of synthetic enamel paint over one coat of primer comprising Incoming:- One number MCCB 250 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz complete. NOTE:-(Drg / design of Panel shall to be approved before given order to concern factory )
M&L in repairs pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
Supply only Capacitor 415 V, AC 3Ø, 5 KVAR complete
Supply only Capacitor 415 V, AC 3Ø, 10 KVAR complete
Supply only Capacitor 415 V, AC 3Ø, 25 KVAR complete
Supply only MCB four pole 40 to 63 amps, 10 KA, 'C' series ISI marked complete
Supply only High break HBC fuse link 315 Amps 80kA,50Hz complete
Supply only CT Coil class 1.0 of any CT ratio not exceeding 150/5 complete.
M&L for servicing, repairing and welding to out door LT Panel / LT Feeder Piller box by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged copper/aluminium lugs (iv) Replacement of deteriorated copper wiring with existing sizes of cable (v) Cleaning and tightening of MCCB terminals (vi) Replacement and fixing of sheared rubber beadings (vii) Rectifying of loose connections of incoming and outgoing cables, replacement of busbar sleeve & cables (viii) Painting two coat of smoke gray colour over one coat of primer and black paint on base channel after rubing with emery paper and making smooth finishes (ix) Providing of door locking arrangement with of sliding bolts on panel door (x) Proper welding of Panel door/roof as required (xi) Repacement of nuts, bolts & washers as requirement (xii) Connecting / cleaning of earth wire /earth strip (xii) Two coat of white distemper on foundation.
S&F in replacement Digital AC voltmeter, 4 digit, 7 segment LED display, square type, input voltage 50 -480VAC and connecting the cable on existing panel complete
S&F in replacement Digital AC Ammeter 4 digit, 7 segment LED display, square type input voltage 50 -480VAC and connecting the cable on existing panel complete
S&F in replacement LED indication lamps R/Y/B with base on existing panel and connecting up the cables complete.
M&L for taking out of unserviceable LT cable XLPE, aluminium armoured type up to 25 Sqmm 4 core from existing complete
M&L for taking out from site of unserviceable LT cable XLPE, aluminium armoured type 35 Sqmm 3.5 core to 185 Sqmm 3.5 Core core from existing complete.
Supply, laying and testing of 10 sqmm 2 core LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete. Note: Excavation Earth work, Returning filling, removal, sand cushining, cable protection cover, GI protection pipe etc. shall be measured and paid for seperately under respective item of Sch 'A'.
All as per Item No 16 above but for 10 sqmm 4 core
All as per Item No 16 above but for 35 sqmm 3.5 core.
All as per Item No 16 above but for 50 sqmm 3.5 core.
All as per Item No 16 above but for 70 sqmm 3.5 core.
All as per Item No 16 above but for 95 sqmm 3.5 core.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available, laid along alignment of cable as protection to cable in trenches complete
M&L for Steel tubes ISI marked 40 mm bore light grade galvanised with all fittings fixed to walls / poles complete.
M&L for Steel tubes ISI marked 80 mm bore light grade galvanised with all fittings fixed to walls / poles complete.
S&F in replacement PVC insulated & sheathed, multistranded copper conductor industrial cable 1.5 sqmm 3 core 1100 volt grade from Junction box to street light fitting complete.
Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying upto 80mm dia GI pipe complete
Dismanteling old straight through LT Cable joint and S&F new straight through cable joint kit out door type with jointing materials (Epoxy joint based) and suitable for 6 to 16 Sqmm 4 Core, 1100 volts sizes of aluminium conductor complete.
Dismanteling old straight through LT Cable joint and S&F new straight through cable joint kit out door type with jointing materials (Epoxy joint based) suitable for 25 to 50 Sqmm 4 Core, 1100 volts sizes of aluminium conductor complete.
Dismanteling old straight through LT Cable joint and S&F new straight through cable joint kit out door type with jointing materials (Epoxy joint based) suitable for 70 to 120 Sqmm 4 Core, 1100 volts sizes of aluminium conductor complete.
M&L for straight through cable joint kit out door type with jointing materials (Epoxy joint based) suitable for 6 to 16 Sqmm 4 Core, 1100 volts sizes of aluminium conductor including necessary excavation & earth work & detection and locating of cable fault in underground damaged LT cables complete.
M&L for straight through cable joint kit out door type with jointing materials (Epoxy joint based) suitable for 25 to 50 Sqmm 4 Core, 1100 volts sizes of aluminium conductor including necessary excavation & earth work & detection and locating of cable fault in underground damaged LT cables complete.
M&L for straight through cable joint kit out door type with jointing materials (Epoxy joint based) suitable for 70 to 120 Sqmm 4 Core, 1100 volts sizes of aluminium conductor including necessary excavation & earth work & detection and locating of cable fault in underground damaged LT cables complete.
Surface excavation not exceeding 30 cm deep & leveling the area for making clean to sub station open areas, removing grass, shrub, roots, brickbats etc complete.
M&L for spreading 40 mm graded stone aggregate deposited, spread and levelled in layers not exceeding 15 cm thick through out the sub station / out door panel foundation in open areas complete.
Dismantling / disconnecting the existing LT feeder pillar box / Indoor Panel with all outgoing / incoming supplies, making alternative arrangement for supply including minor diversion of cables as required.
S&F in replacement MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete
S&F in replacement MCCB 4 Pole, 415 V, fixed type, 160 Amps with breaking capacity 36 KA complete
S&F in replacement MCCB 4 Pole, 415 V, fixed type, 250 Amps with breaking capacity 36 KA complete
S&F in replacement MCCB 4 Pole, 415 V, fixed type, 350 Amps with breaking capacity 36 KA complete
S&F in replacement MCCB 4 Pole, 415 V, fixed type, 400 Amps with breaking capacity 36 KA complete
S&F in replacement 1100 volts grade Service Cable of size 6 Sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular Complete
S&F in replacement 1100 volts grade Service Cable of size 10 Sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular Complete
S&F in replacement 1100 volts grade Service Cable of size 16 Sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular Complete
Supplying, installation, connecting electrically, commissioning and testing in replacement Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz, 3 phase 100 KVAR (Multiple of 10 KVAR) including the following complete:
(a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 100 KVAr at 440 Volts with ratio Outgoing steps (10 kvar + 15 Kvar + 25 Kvar + 50 Kvar) confirming to IS -13340, 13341, & IEC - 60831 - 1 +2.
(b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947.
(c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors.
(i) Capable of 4 - Quadrant operation, and any phase offset requirement.
(ii) Swithching programms : LIFO, Combi - filter, manual mode.
(iii) Build in under and over voltage release with auto reset.
(iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz.
(v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A.
(vi) Commissioning without additional settings and programming.
(vii) Three decimal power factor reading.
(e) MCB "D", 3 Pole, 415 Volts Curve type with rupturing cap 10 kA of appropriate rating for protection of individual capacitor bank conf to IS 8828, IEC 898.
(f) Incoming TPN MCCB, 250 Amps, Ics = 100% Icu , 25 KA, 4 Pole.
(g) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending the temperature of the panel.
(h) Emergency stop push button to disconnect the unit in case of emergency.
(j) Indicator LED type for phase indication and capacitor banks ON and OFF indication.
(k) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI Approved) made out of 3.15 mm thick MS sheet factory made duly powder coated front and rear door openable with locking arrangement with foundation as recommended by manufacturer.
Shree Karni Construction
Electricals India
BK CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .